| 1 | Earth work in excavation by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressingof sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m complete all as specified and directed. |
| 2 | Returning filling in, including spreading, levelling, watering and well ramming in layers each not exceeding 25 cm depth in soft/loose soil complete all as specified and directed. |
| 3 | Excavating tranches pipes , cables etc exceeding 80 mm but not exceeding 300 mm dia including excavation for sockets, depth upto 1.5 m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc and disposal of unserviceable material as directed within a lead of 50 m complete all as specified and directed. |
| 4 | Demolition and breaking up drain pipes of internal dia of 150 mm of (salt glazed ware, AC or reinforced concrete) pipe set in cement motar including cement concrete bedding and haunching complete all as specified and as directed. |
| 5 | M&L for Salt glazed stoneware (SGSW) drain pipes, grade `A` of 150 mm internal dia laid in trenches and jointed in cement mortar 1:1 all as specified and as directed. |
| 6 | M&L for Reinforced concrete pipes, class NP-2, 150 mm bore grade Á with collar laid in trenches and jointed with cement mortar 1:1 complete all as specified and as directed. |
| 7 | M&L for cement concrete 1:3:6 type C-2 (using 40 mm graged stone aggregate) as in concrete bed to drain pipes of 150mm bore including packing under, and haunching against the sides of pipes after they are laid and tested, complete all as specified and as directed. |
| 8 | Demolition of brickwork or stone boulder masonry built in cement mortar including all quoins, arches, pillars ,precast louvers and jallies etc. complete all as specified and as directed. |
| 9 | M & L for brick work with sub-class 'B' bricks, straight or curved on plan exc 6.0 metre mean radius as wall built in cement & sand mortar 1:6, complete all as specified and as directed. |
| 10 | Taking down cement or cement lime plaster of any description from brick or stone walls including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and as directed. |
| 11 | M&L rendering 15 mm thick plaster of brick work in CM 1:4 and surface finished fair and even , complete all as specified and directed. |
| 12 | M&L for PCC, 1:4:8 type D-2 using 40mm graded stone aggregate in foundation, filling and mass concrete complete all as specified. |
| 13 | M&L for PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) as in coping, benchings inside the main hole etc. complete all as directed and as specified |
| 14 | dismantling of manhole cover of any description or thickness and removing from site complete all as specified and as directed. |
| 15 | S&F heavy duty factory made precast steel fibre reinforced concrete (SFRC) any colour 75-100 mm thick manhole cover with coller/frames (ISI Marked) of overall covered area not exceeding 2 sqm with clear opening 600mm x 900 mm provided with suitable mild steel rims to prevent from chipping of edges and enable clear opening with provision of easy lifting hooks with and duly protected against corrosion laid over and including 10 mm thick rendering in CM 1:4 complete all as directed and as specified. |
| 16 | S&F heavy duty factory made precast steel fibre reinforced concrete (SFRC) any colour 75-100 mm thick manhole cover with coller/frames (ISI Marked) of overall covered area not exceeding 02 sqm with clear opening 600mm x 600 mm provided with suitable mild steel rims to prevent from chipping of edges and enable clear opening with provision of easy lifting hooks with and duly protected against corrosion laid over and including 10 mm thick rendering in CM 1:4 complete all as directed and as specified. |
| 17 | S&F heavy duty factory made precast steel fibre reinforced concrete (SFRC) any colour 75-100 mm thick manhole cover with coller/frames (ISI Marked) of overall covered area not exceeding 02 sqm with clear opening 450 mm x 450 mm provided with suitable mild steel rims to prevent from chipping of edges and enable clear opening with provision of easy lifting hooks with and duly protected against corrosion laid over and including 10 mm thick rendering in CM 1:4 complete all as directed and as specified. |
| 18 | S&F heavy duty factory made precast steel fibre reinforced concrete (SFRC) any colour 75-100 mm thick manhole cover circular type with coller/frames (ISI Marked) with clear opening 550 to 600mm in round shape provided with suitable mild steel rims to prevent from chipping of edges and enable clear opening with provision of easy lifting hooks with and duly protected against corrosion laid over and including 10 mm thick rendering in CM 1:4 complete all as directed and as specified. |
| 19 | M&L for providing precast cement concrete 1:2:4 type B0 (using 12.5 mm graded stone aggregate) louvers and jallies 30 mm thick including all mouldings set in CM 1:4 complete all as directed and as specified. |
| 20 | M & L providing precast concrete Posts 100x100mm size & 75-100 cm height 1:3:6 type C0 using 12.50 mm graded stone aggregate as in RCC jali post setting in mortar 1:6 complete all as directed and as specified. |
| 21 | Roughning surface of existing RCC roof slab complete all as directed |
| 22 | M&L for RCC type B1 (1 : 2 : 4) nominal mix using 20 mm graded stone aggregate in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies and in shelves and the like including demolition of existing RCC complete all as directed |
| 23 | M&L for mild steel TMT bars 8-10 mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia. |
| 24 | M&L for form work to soffits of flat, rough finished surfaces of concrete of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick(Horizontal or sloping) |
| 25 | Excavation in post hole (or similar hole) each n exc 0.5 cum each in all kind of soil including getting out the excavated soil, then returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering etc, disposing of surplus excavated soil as directed within a lead of 50 m andlift upto 1.5m complete all as specified and as directed. |
| 26 | M&L for cement concrete type C2 1:3:6 (using 40 mm graded stone aggregates) as in foundation, filling and mass concrete complete all as specified and as directed. |
| 27 | S&F Mild steel work as in hand rails , half round or other section, balusters running bars, nosing to steps, wind ties, posts and struts in fencing incl cutting tops to shape as required, drilling holes , noching for wire , flat iron fillets for securing wiremesh etc. incl all necessary welding work, drilling, bolting or riveting etc & similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 28 | S&F mild steel round bars 10mm dia cut to length, bent to shape required bent to shape hoking end required and fixed in fencing confirming to Fe 410-W (Gde E-250) or Fe 290 (Gde E-165) complete all as specified and as directed. |
| 29 | S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm but n exc 10cm long complete all as specified and as directed. |
| 30 | Supply only chain link having MS galvanised wire and mesh of any size as directed complete all as specified and as directed. |
| 31 | Fixing only chain link fencing including line wire any mesh, size and tied to any type of standards, rails, straining bolts etc complete all as specified and as directed. |
| 32 | M&L for preparation of new steel and iron surface of any description and applying 2 coats of syntheltic enamel paint over a coat of red oxide primer, complete all as specified and as directed. |
| 33 | S&F in repair 110mm PVC pipes of working pressure not less than 6 Kg/sqcm single socketed, excluding fittings in any length with rubber ring joints, laid in trenches or in floors complete all as directed and as specified. |
| 34 | S&F in repair 110 mm bore PVC pipes of working pressure not less than 6 Kg/sqcm single socketed in any length with rubber ring joints fixed to wall incl necessary clamp etc. including demolition of old pipes complete all as directed and as specified. |
| 35 | S&F in repair 75mm PVC pipes of working pressure not less than 6 Kg/sqcm single socketed, excluding fittings in any length with rubber ring joints, laid in trenches or in floors complete all as directed and as specified. |
| 36 | S&F in repair 75 mm bore PVC pipes of working pressure not less than 6 Kg/sqcm single socketed in any length with rubber ring joints fixed to wall incl necessary clamp etc. including demolition of pipes complete all as directed and as specified. |
| 37 | S&F in repair 110 mm dia PVC bends any radius with oval access door complete all as directed and as specified. |
| 38 | S&F in repair 75 mm dia PVC bends any radius complete all as directed and as specified. |
| 39 | S&F in repair 110mm PVC junction single, (Single T) equal or unequal with acess door complete all as directed and as specified.. |
| 40 | S&F Stack clamps made out of 50mm x 5mm flat iron & 16mm round iron stays including bolts & nuts and securing ends of stays for 100mm bore pipe complete all as directed and as specified. |
| 41 | S&F in repair 75mm PVC floor trap plain with grating including jointing with solvent cement complete all as directed and as specified. |
| 42 | M&L for cleaning of blocked sewage line consisting of SGSW pipes, RCC pipes, CI pipes, PVC pipes up to 200 mm bore and manholes of any size depth n.exc 3.00 m, Floor/Nahani trap 'T' Junction soil waste and vent pipe, bends and Gully traps etc including Bamboo strips , Iron rods, sewage rodding machine, hony sheking machine/sewage dewatering pumb etc manholes, septic tanks and desluding Manholes, septic tank and removal of sludge in covered vehicles outside the MD land by deployment of (2.0) No.s safaiwala for Md accn area in OD Complex at Mathura cantt all as directed by Engineer-in Charge. |
| 43 | M&L for cleaning of blocked sewage line consisting of SGSW pipes, RCC pipes, CI pipes, PVC pipes up to 200 mm bore and manholes of any size depth n.exc 3.00 m, Floor/Nahani trap 'T' Junction soil waste and vent pipe, bends and Gully traps etc including Bamboo strips , Iron rods, sewage rodding machine, hony sheking machine/sewage dewatering pumb etc manholes, septic tanks and desluding Manholes, septic tank and removal of sludge in covered vehicles outside the MD land by deployment of (2.0) No.s safaiwala for OTM accn area in OD Complex at Mathura cantt all as directed by Engineer-in Charge. Please Enable Macros to View BoQ information |
| 44 | M&L for cleaning of blocked sewage line consisting of SGSW pipes, RCC pipes, CI pipes, PVC pipes up to 200 mm bore and manholes of any size depth n.exc 3.00 m, Floor/Nahani trap 'T' Junction soil waste and vent pipe, bends and Gully traps etc including Bamboo strips , Iron rods, sewage rodding machine, hony sheking machine/sewage dewatering pumb etc manholes, septic tanks and desluding Manholes, septic tank and removal of sludge in covered vehicles outside the MD land by deployment of (2.0) No.s safaiwala for OTM accn area in OD Complex at Mathura cantt all as directed by Engineer-in Charge. Please Enable Macros to View BoQ information |