| 1 | Excavation in trenches in hard/dense soil not exc 1.50 mtr wide and not exc 1.50 mtr depth for foundation etc n. exc 10 sqm on plan and getting out complete all as specified & directed. (Note : Excavation works are to be executed manually only. The use of mechanical equipment is strictly prohibited, as the site conditions do not permit mechanized operations) |
| 2 | Excavation in trenches in Disintegrated rock not exc. 1.50 mtr wide and not exc 1.50 mtr depth for foundation etc n. exc 10 sqm on plan and getting out complete all as specified & directed. (Note : Excavation works are to be executed manually only. The use of mechanical equipment is strictly prohibited, as the site conditions do not permit mechanized operations) |
| 3 | Returning, filling in trenches including spreading, leveling, watering and well ramming in layers n,exec 25 cm each layer complete all as specified and directed |
| 4 | Removing excavated material to a distance n.exc 50m and deposited where directed at a level n. exc 1.5 m above the starting point complete all as specified and directed |
| 5 | M & L for Cement concrete in foundations, filling and mass concrete type C2, 1:3:6 (40 mm graded aggregate) complete all as specified and directed |
| 6 | M & L for Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in, 1:6 cement mortar complete all as specified and directed |
| 7 | S & F Mild steel cross arms, bracing, supports, clamps and back plates, fabricated from structural steel sections incuding nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated with a coat of red oxide primer, one under coat and one finshing coat of aluminium paint complete all as specified & directed by Engr-in Charge. |
| 8 | S & F Reinforced concrete pipes, 300 mm dia, class NP2, laid and jointed complete with collars all as specified and directed. |
| 9 | S & F Reinforced concrete pipes, 150 mm dia, class NP2, laid and jointed complete with collars all as specified and directed. |
| 10 | M & L for taking out existing upto 150 mm dia DI Pipeline from trench of any depth and length and relaying / shifting the same out of trench area carefully including reqd washers, jointing kit etc complete all as specified and directed. Note for Item No 8 to 10 : Excavation will be measured and paid seperately. |
| 11 | M & L for Cable jointing kit for XLPE cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 50sqmm to 95sqmm., complete all as specified and as directed by Engr-in-Charge. |
| 12 | M & L for Cable jointing kit for XLPE cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 120sqmm to 185sqmm., complete all as specified and as directed by Engr-in-Charge. |
| 13 | M & L for Cable jointing kit for XLPE cable for straight through heat shrink type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 50sqmm to 95sqmm., complete all as specified and as directed by Engr-in-Charge. |
| 14 | M & L for Cable jointing kit for XLPE cable for straight through heat shrink type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 120sqmm to 185sqmm., complete all as specified and as directed by Engr-in-Charge. |
| 15 | M & L for excavation of cable trench of any depth and length, for finding out cable fault, taking out carefully bricks, sand and electric UG cable any type of size, from trenches / pipe etc for repair the same and relaying the same after reapir to original location and using removed sand and bricks etc and refilling the cable trench all as specified and directed. Note : Cable end termination & straighthrough joints will be measured and paid seperately under respective items. |
| 16 | S & F, HDPE, DWC, 150 mm dia pipe for cable protection etc complete all as specified and directed |
| 17 | S & F, FRP Composite chamber Cover of size not less than 900 cm x 1200 cm made of standard designs conforming to IS:1726-1991, having load bearing of 12.5 TON , min thickness 35mm without frame complete all as specified and directed complete all as specified and directed |
| 18 | M&L for rendering 15mm thick cement plaster in 1:4 on fair faces of brick work or concrete surfaces, finished even and fair without using extra cement complete all as specified & directed. |
| 19 | M & L for taking out existing UG cables of any size and make from trench of any depth and length and relaying / shifting the same out of the trench area/ relaying the cable in trench carefully including fixing of cable on iron angle including disconnenction to remove the cable and reconnection after laying of cable complete all as specified and directed. Note : If Excavation is reqd will be measured and paid seperately. Please Enable Macros to View BoQ information |