| 1 | Schedule-A |
| 2 | Dismantling of unserviceable concerete/steel tubular pole any size upto 9 mtr long including breaking up PCC and making good disturbed surface and removing materials from site of work complete all as specified and directed. |
| 3 | M & L for PCC 1:4:8, type D-2, (using 40mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed. |
| 4 | M & L for PCC 1:3:6, type C-2, (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed. |
| 5 | M & L for PCC 1:2:4, type B-1, (using 20mm graded stone aggregate) as in coping including necessary use & waste of form work complete all as specified and directed. |
| 6 | Supply and fixing of steel tubular swaged poles swan neck type with two coat of aluminium paint ovar a coat of red oxide zinc chrome prime in externally exposed to view portion and black bituminous painting to intenal surface and portion embeded in concrete incl making five alternative strips 30 cm wide in different colour above ground level or plinth level incl marking of MES pole No in black paint complete with cast iron base plate, final tapper plug, bolts, nuts and screws as specified type 410 SP-31 (9.00 mtr long) and all as specified. |
| 7 | M &L for demolition of cement concrete in ground floors and pavings n.exc 15 cm thickness (below or above ground level) |
| 8 | M&L for PCC 1:3:6 type C-1 using 20mm graded stone aggregates for filling in road cuts/hard standing etc all as specified and as directed. |
| 9 | Supply and laying 100 mm bore galvanised iron tubing, light grade with all fittings for passing of cables under ground complete all as specified and as directed. |
| 10 | Supply and laying 80 mm bore galvanised iron tubing, light grade with all fittings for passing of cables under ground complete all as specified and as directed. |
| 11 | Supply and laying 50 mm bore galvanised iron tubing, light grade with all fittings for passing of cables under ground complete all as specified and as directed. |
| 12 | Supply and laying 40 mm bore galvanised iron tubing, light grade with all fittings for passing of cables under ground complete all as specified and as directed. |
| 13 | M & L for Cross arm bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of two coats of aluminium paint over a coat of zinc chrome primer complete all as specified. |
| 14 | Supply and fix in repair PVC insulated single core stranded cable with alluminium conductor 1100 volts grade of size 35 Sqmm in existing LT overhead line for jumfering , LT Panel to transformer Boards including disconnecting and taking down at different locations |
| 15 | Supply and fix in repair PVC insulated single core stranded cable with alluminium conductor 1100 volts grade of size 95 Sqmm in existing LT overhead line for jumfering , LT Panel to transformer Boards including disconnecting and taking down at different locations |
| 16 | Supply and fix in repair PVC insulated single core stranded cable with alluminium conductor 1100 volts grade of size 630 Sqmm in existing LT overhead line for jumfering , LT Panel to transformer Boards including disconnecting and taking down at different locations |
| 17 | Disconnecting electric connection from transformer and excavation incomming and outgoing cables and shifting a site . Dismantling damaged PCC platform and make good distrubed area as per existing area including m&L for making new platform of transformer and refixing and reshifting the transformer at same location after necessary repair, including connection of incoming and outgoing cables , removing PCC platform material from site and depositing at places all as directed by Engr-in-Charge |
| 18 | M&L for scraping, cleaning and preparation of old white wash and damage PCC plaster surfaces of transformer plinth complete and M&L for plastering 15 mm thick in CM 1:6 on top and around transformer plinth including two coats of colour wash over one coat of white wash complete all as directed by Engr-in-Charge |
| 19 | Demolition of brick work or stone/boulder masonary built in cement mortar including all quoins arches pillars etc, but excluding ashlar facing, dressed stone work and precast concrete articles complete all as specified & directed. |
| 20 | Material & labour for brick work with sub class ‘B’ bricks straight or curved on plan exc. 6 mtr mean radius built in cement mortar (1:6) complete all as specified & directed. |
| 21 | Material & labour for brick work with sub class ‘B’ bricks straight or curved on plan to any radius in half brick thick wall built in cement mortar 1:4 complete all as specified & directed. |
| 22 | Cutting of worn out alluminium cable terminal lugs from the transformer and panel cable, crimping of new aluminium cables core , with suitable size of lugs and fixing with transformer and panel terminal stud including cutting/dressing of cable, excavation surface after providing redressing of excavated surface after providing sand cushioning and brick protection as specified and directed by Engr-in-Charge. |
| 23 | M&L for transformer fencing around the brickplateform with GI chain ling fencing of size 100mmx100mm, 4mm dia including line wires, any mesh, size and type of standard, rails, straining bolts etc. Mild Steel work such as angle iron fencing post struts and flat iron fillets etc. Angle iron size 65x65x6 mm thick and post embeded in PCC 1:2:4 type B2 block 300 mmx300mmx400mm, (spacing of angle iron shall not be more than 2.5 M), including drilling holes, punching, splitting ends to secure chain link fencing and all necessary cutting, welding drilling, bolting or riveting etc and including bands strap (Flat iron 50x5mm thick) support for chain link, steel screw as required, 10 mm dia MS bar as in the bars placed horrizontally at bottom, middle and top along length of fencing, height to fencing 1.5 Mtr clear from GL and approx 12 m length with necessary gate made out of angle iron 50mmx50mmx5mm with locking arrangement c, with 65 mm Godrej pad llock, handle, hinges, etc complete (Approx size 1200mmx1800mm) including one coat of redoxide zinc chrome primer and two coats of synthetic enamel paint on prepared steel surfaces (except GI chain link fencing) all as specified and directed. |
| 24 | Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr in depth and getting out soft/loose soil complete all as specified and as directed for foundation of stay, laying of cable etc. |
| 25 | Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr in depth and getting out hard/Dense soil complete all as specified and as directed for foundation of stay, laying of cable etc. |
| 26 | Returning filling in soil including spreading, levelling, watering and well ramming in layers not exc 25 cm |
| 27 | Removing excavated material soil n.exc 50 m and depositing where directed at a level n.exc 1.5 mtr above the starting point all as directed. |
| 28 | Material and labour for fly ash/burnt Bricks, sub class 'B' dry, well brunt bricks laid in trenches for cable protection all as specified. |
| 29 | M&L for sand filling in trenches for cushioning of cable complete all as specified and directed. |
| 30 | Relaying of serviceable GI Pipe of any size, type and capacity |
| 31 | Taking up old serviceable/unserviceable UG cable from trench for replacement , repair and re-laying or re-routing of size and make good the disturbed surface to the existing :-Earth work shall be measured and paid separately under appropriate items of Sch-'A') |
| 32 | 10 Sqmm 2 Core to 35 Sqmm 3.5 Core |
| 33 | 50 Sqmm 3.5 Core to 150 Sqmm 3.5 Core |
| 34 | 185 Sqmm 3.5 Core to 400 Sqmm 3.5 Core |
| 35 | Supply, laying, testing and commissioning LT UG armoured, XLPE insulated, inner and outer sheathed,PVC insulated with multi stranded aluminium conductor cable of 1100 volts grade, ISI marked with IS-7098, laid in trenches/floor/duct/wall including aluminium lugs of suitable sizes complete all as specified and as directed of the following size :- |
| 36 | 10 Sqmm 2 Core |
| 37 | 16 Sqmm 2 Core |
| 38 | 16 Sqmm 4 Core |
| 39 | 25 Sqmm 3.5/4 Core |
| 40 | 35 Sqmm 3.5 Core |
| 41 | 50 Sqmm 3.5 Core |
| 42 | 70 Sqmm 3.5 Core |
| 43 | 95 Sqmm 3.5 Core |
| 44 | 120 Sqmm 3.5 Core |
| 45 | 150 Sqmm 3.5 Core |
| 46 | 185 Sqmm 3.5 Core |
| 47 | 240 Sqmm 3.5 Core |
| 48 | 300 Sqmm 3.5 Core |
| 49 | 400 Sqmm 3.5 Core |
| 50 | Re-laying serviceable bricks as obtained from here-in-before. |
| 51 | Boring of holes under road, pavement, hard standing, drain etc by conventional method not exceeding 5 mtr in length for laying of cable for protection of pipe etc complete. |
| 52 | M&L for cutting the existing bitumen us road/payment/footpath upto 0.75 mtr in depth, 0.45 mtr in width and getting out excavated material and making good the damaged portion after laying the pipe, returning filling in mass concrete PCC 1:2:4 type B2 upto top of the road all as directed by Engr-in-Charge. Note :-(i) M&L for laying of pipe shall be measured and paid separately. |
| 53 | Cutting chases, pining in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc ; and cutting chases for concealed conduit wiring, etc and making good, cutting exceeding 10 cm but not exceeding 20 cm girth and 5 cm width. |
| 54 | Supply and fixing in repair LT UG cable aluminium lugs of following size including disconnection of U/S lugs from panel and making electrical connection complete all as specified and directed by Engr-in-Charge. |
| 55 | 120 Sqmm |
| 56 | 95 Sqmm |
| 57 | 70 Sqmm |
| 58 | 50 Sqmm |
| 59 | 35 Sqmm |
| 60 | 25 Sqmm |
| 61 | 150 Sqmm |
| 62 | 185 Sqmm |
| 63 | 240 Sqmm |
| 64 | 400 Sqmm |
| 65 | M& L for straight through joint/end terminal joints heat shrink type complete suitable for LT PVC & XLPE insulated, sheathed UG cable for aluminium conductor cable and testing after joining of 4 core 35 to 50 Sqmm complete |
| 66 | All as per item No 37 here-in-before but 4 core 70 to 150 Sqmm size |
| 67 | All as per item No 37 here-in-before but 4 core 150 to 240 Sqmm size |
| 68 | All as per item No 37 here-in-before but 4 core 300 to 400 Sqmm size |
| 69 | Machine pressed precast concrete interlocking paver block in repair of any shape and size confirming to IS 15658- 2006 of 80 mm thickness, M-40 grade, with grey cement and no pigment. |
| 70 | Finding out, locating and pin point the cable fault of any size and any capacity of cable from LT 1100 volt grade to 11000V with the help of cable fault loacator and with nessary disconnection of cable from two ends and connection after repairs and having the following items with electrician at site up to lenth of 1 KM cable complete all as specified and directed by Engr-in-Charge :- (a) Surge Generator with accessories-01 Nos, (b) Head Phone-01 Nos , (c) Pin Point Set T-505 with accessories-01 Nos, (d) Earthing cable with clamp-01 set, (e) Cable fault Locator T-905 with accessories-01 Nos, (f) TC-808 with accessories-01 Nos, (, g) Soldering Iron-01 Nos, (h) Soldering wire-01 Nos, (j) Plier-01 Nos, (k) Soldering paste-01 Nos, (l) Capacitor Unit-01 Nos, (m) Capacitor connecting cables-01 Nos, (n) Power cable-01 Nos, (o) Nose Plier-01 Nos, (p) Card for SSG-1100-01 NosNote :- Transportation charges for shifting of cable fault locator will deem to be include in above said job and nothing extra on this account will be admissible. |
| 71 | Earthing complete with GI steel earth plate electrode 60cm x 60cmx6.3mm thick barried directly in ground vertically to a depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less than 1.5 mtrs below level ground, connected to GI iron or steel earth wire 4mm dia (8 SWG) by means of nuts, volts checks nuts and washers made of GI iron or steel earth wire protected by GI iron pipe 15mm bore, medium grade and connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1, pre-cast RCC over slab 30cmx30cmx10cm with one lifting handle made of 8mm dia MS bar funnel wire mesh, 20mm bore GI or steel pipe medium grade for watering, charcoal or coke and salt in alternate larges, necessary excavation and earth work in any type of soil complete all as shown in electrical plate No 5 of MES schedule Part-I and testing after completion. |
| 72 | Earthing complete with galvanised steel earth plate electrode size 60 cm x 60 cm, 6.3 mm thick burried directly in ground vertically to a depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level, connected to galvanised iron or steel, earth strip 32 x 6 mm size by means of nuts, bolts check nuts and washers made of galvanised iron or steel, earth wire protected by galvanised iron pipe 15mm bore, medium grade and connected to main switch board or main control board as directed and including concrete pit in PCC 1:3:6 type C-1(using 20 mm graded stone aggregate), pre-cast RCC cover slab 30 cm x 30 cm x 10 cm with one lifting handle made of 8 mm dia MS bar funnel wire mesh, 20 mm bore galvanised iron or steel pipe medium grade for watering charcoal or coke and salt in alternate layers, necessary excavation and earth work in any type of soil complete all as shown in electrical Plate No 5 of MES Schedule Part- I and testing on completion . (Concrete pit shall be 20 cm to 30 cm away from main pit). |
| 73 | Taking down existing old LT panel board/ LT feeder pillar box comprising of MCCB & switch fuse unit of any capacity and size including bus bar, ammeters, voltmeters etc after disconnecting all cable connection and removing from site complete all as directed. Please Enable Macros to View BoQ information |
| 74 | Taking down existing old LT panel board/ LT feeder pillar box comprising of MCCB & switch fuse unit of any capacity and size including bus bar, ammeters, voltmeters etc after disconnecting all cable connection and removing from site complete all as directed. Please Enable Macros to View BoQ information |