|
| 1 | Preventive, Non Comprehensive & Periodical maintenance/ Breakdown maintenance of Water cooled screw type compressor chiller plant of Capacity 3x100TR, checking serviceability of the parts of Microprocessor Based Control Panel such as microcontroller cards, sensors, relays, contactor, switches etc., compressor oil checking, checking of leakage of refrigerant piping etc.and descaling of condensor with suitable descaling chemical complete all as specified & directed. Make of installed AC plant: Voltas, Model No: GSWCDXR100-1 |
| 2 | Preventive, Non Comprehensive & Periodical maintenance/ Breakdown maintenance of Water cooled screw type compressor chiller plant of Capacity 3x60TR, checking serviceability of the parts of Microprocessor Based Control Panel such as microcontroller cards, sensors, relays, contactor, switches etc., compressor oil checking, checking of leakage of refrigerant piping etc. and descaling of condensor with suitable descaling chemical complete all as specified & directed. Make of installed AC plant: Blue Star, Model No: LCWR1-60A |
| 3 | Preventive, Non Comprehensive & Periodical maintenance/ Breakdown maintenance of Water cooled scroll type chiller plant of Capacity 3x25TR, checking serviceability of the parts of Microprocessor Based Control Panel such as microcontroller cards, sensors, relays, contactor, switches etc., compressor oil checking, checking of leakage of refrigerant piping etc. and descaling of condensor with suitable descaling chemical complete all as specified & directed. Make of installed AC plant: Blue Star, Model No: XWC2S-026AR2 |
| 4 | Preventive, Non Comprehensive & Periodical maintenance / break down maintenance of 3x150TR Central Air Conditioning Plant semi-hermetic/open type compressor along with motor and its condenser, flooded chiller, microprocessor based control panel, sensors, relays, contactors, switches complete as per manufacturer's manual of preventive and comprehensive maintenance with periodicity (monthly) mentioned therein and as per particular specifications detailed here-in-after complete all as specified & directed. Make of installed AC plant: Blue Star, Model No: LCWX1-0525D. Please Enable Macros to View BoQ information |
| 5 | Preventive, Non Comprehensive & Periodical maintenance / break down maintenance of 3x150TR Central Air Conditioning Plant semi-hermetic/open type compressor along with motor and its condenser, flooded chiller, microprocessor based control panel, sensors, relays, contactors, switches complete as per manufacturer's manual of preventive and comprehensive maintenance with periodicity (monthly) mentioned therein and as per particular specifications detailed here-in-after complete all as specified & directed. Make of installed AC plant: Blue Star, Model No: LCWX1-0525D. Please Enable Macros to View BoQ information |