Indian Tenders

Tender Notice

TDR 55765197
Tendering Authority Uttar Pradesh Jal Nigam
Tender No NIT No 1037 / SBM(U) 2.0 GBN DADRI NPP ID WORKS/15 Date 27.05.2026
Tender ID 2026_UPJNM_1156197_1
Tender Brief Corrigendum : Tender For Investigation, Survey (On G.I.S. Basis) & Construction Of Stp Cum Co-Treatment Facilities (10.60 Mld Stp & 11.50 Kld Co-Treatment), I&D Of Drains And Structure, Rising Main, Treated Effluent Line With Scada Etc., In Dadri Nagar Palika Pari
City Dadri
State Uttar Pradesh
Document Fees INR 23600 /-
EMD INR 3846000.0 /-
Tender Value INR 38.45 Crore /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Investigation, Survey (On G.I.S. Basis) & Construction Of Stp Cum Co-Treatment Facilities (10.60 Mld Stp & 11.50 Kld Co-Treatment), I&D Of Drains And Structure, Rising Main, Treated Effluent Line With Scada Etc., In Dadri Nagar Palika Parishad, Distt- Gautam Buddha Nagar.This Work Includes Successful Testing, Commissioning & 03 Month Trial & Run Of Following Components:- A) Design & Construction Of 10.60 Mld Stp & 11.50 Kld Co-Treatment On Sbr Technology Including Mps With All Civil, Electrical, Mechanical Instrumentation And Scada Enabled Operation System With All Related Works.B) Design & Construction Of Interception & Diversion Of Drains (250 Mm Dia. To 1100 Mm Dia.Rcc Np3 Pipe). C) Design & Construction Of I&D Structure Work. D) Design & Construction Of Rising Main (450 Mm Dia. D.I.K-9 Pipe). E) Design & Construction Of Treated Effluent Line (Ac Pressure Pipe 600Mm Dia.) The Scope Of Work Also Includes Trial & Run Of 03 Months And Defect Liability Period Of 12 Months For Civil Works And 24 Months For E/M Works Which Shall Start After Completion Of Successful Trial & Run. All Completed And Commissioned Work Under Interception And Diversion (I&D) And Stp (10.60 Mld) With Co-Treatment Facility (11.50 Kld) Works Scheme In Dadri Nagar Palika Parishad Distt.Gautambuddha Nagar Shall Be Handed Over To Dadri Nagar Palika Parishad After 03 Months Successful Trial & Run Period. All Completed And Commissioned Works Under Interception And Diversion (I&D) And Stp (10.60 Mld) With Co-Treatment Facility(11.50 Kld) Works Scheme In Dadri Nagar Palika Parishad . As Per Specifications In Tender Document.

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 10-06-2026 Corrigendum Other 15-06-2026

Key Dates

Publish Date 10-06-2026
Last Date of Bid Submission 15-06-2026

Contact Information

Company Name Uttar Pradesh Jal Nigam
Contact Person Superintending Engineer
Address SE Construction Circle UPJN Urban Ghaziabad

BOQ Items

Name of Work:- Investigation, Survey (On G.I.S. Basis) & Construction of STP cum Co-Treatment facilities (10.60 MLD STP & 11.50 KLD co-treatment), I&D of drains and structure, rising main, treated effluent line with SCADA etc., in Dadri Nagar Palika Parishad, Distt- Gautam Buddha Nagar.This work includes successful testing, commissioning & 03 month trial & run of following components:- a) Design & construction of 10.60 MLD STP & 11.50 KLD co-treatment on SBR technology including MPS with all civil, electrical, mechanical instrumentation and SCADA enabled operation system with all related works.b) Design & construction of interception & diversion of drains (250 mm dia. to 1100 mm dia.RCC NP3 pipe). c) Design & construction of I&D structure work. d) Design & construction of rising main (450 mm dia. D.I.k-9 pipe). e) Design & construction of treated effluent line (AC pressure pipe 600mm dia.) The scope of work also includes trial & run of 03 months and defect liability period of 12 months for civil works and 24 months for E/M works which shall start after completion of successful trial & run. All completed and commissioned work under Interception and Diversion (I&D) and STP (10.60 MLD) with Co-treatment facility (11.50 KLD) Works Scheme in Dadri Nagar Palika Parishad Distt.Gautambuddha Nagar shall be handed over to Dadri Nagar Palika Parishad after 03 months successful trial & run period. All completed and commissioned works under Interception and Diversion (I&D) and STP (10.60 MLD) with Co-treatment facility(11.50 KLD) Works Scheme in Dadri Nagar Palika Parishad . as per specifications in tender document.
Sl. No. Item Description
1PART (A) - CIVIL WORKS
2Schedule G (i)Interception and diversion (I&D) Sewers (250-1100mm Dia RCC NP3, MS Pipe for trenchless section)
3Excavation below G.L. upto depth as specified for laying sewer and manhole ordinary soil (earth, sand, loam and clay) including cutting of joints pits ramming dressing) leveling, refilling of trenches in 20 cm layer watering and ramming the same including
4(a) 0.00 to 1.50 m
5(b) 01.50 to 03.00 m
6(c) 03.00 to 04.50 m
7(d) 04.50 to 06.00 m
8Provide and fix close timbering in trenches for the depth as specified below G.L. consisting of 40 mm thick approved country wood plank for polling board 125 x 75 mm eucalyptus-Safeda-Sal Wood wallers and 100 mm dia ballies for shuttering at 1.5 m C/C including all labour etc , complete
9(a) 0.00 to 3.00 m
10(b) 03.00 to 06.00 m
11Same as item No. 3 but for open timbering (depth: 1.5 to 3.0m). No timbering has taken for depth below 1.5m
12(a) 1.50 to 03.00 m
13Timbering left in trenches
14Open Timbering left in trenches (used timbering) 0-3m depth
15Closed Timbering left in trenches(used timbering)0-3m depth
16Closed Timbering left in trenches(used timbering)3-6m depth
17Supply of following sizes of RCC spigotted and socketed non pressure pipes( Dia. In mm ) with structural strength as per IS 458 : 2003 and its latest amendment(s).
18RCC NP3 Pipe
19250 mm
20300 mm dia pipe
21500 mm dia pipe
22600 mm dia pipe
23700 mm dia pipe
24800 mm dia pipe
25900 mm dia pipe
261000 mm dia pipe
271100 mm
28Carting following sizes of R.C.C. Hume pipe NP3 Class Socket / spigot rubber ring jointing and specials from store to the work lowering and laying the same in to the trenches upto depth as specified below G.L. true to alignment
29250 mm dia pipe
3000.00 - 0 1.50 m
31300 mm dia pipe
3200.00 - 0 1.50 m
33500 mm dia pipe
3400.00 - 0 1.50 m
3501.50 - 0 3.00 m
3603.00 - 04.50 m
3704.50 - 06.00 m
38600 mm dia pipe
3904.50 - 06.00 m
40700 mm dia pipe
4104.50 - 06.00 m
42800 mm dia pipe
4301.50 - 0 3.00 m
44900 mm dia pipe
4503.00 - 04.50 m
4604.50 - 06.00 m
471000 mm dia pipe
4803.00 - 04.50 m
4904.50 - 06.00 m
501100 mm dia pipe
5104.50 - 06.00 m
52Cement concrete work in bedding below G.L. at specified depth with cement, coarse sand and 20 mm gauge approved stone ballast (1:2:4) including supply of all materials, labour, T&P etc. required for the proper completion of work. (As per statement attached
53(a) 00.00 to 01.50 m
54(b) 01.50 to 03.00 m
55(c) 03.00 to 04.50 m
56(d) 04.50 to 06.00 m
57Filling granular material (well graded crushed rock or gravel maximum size 20mm) into the trenches for class B bedding (granular bedding) including watering compaction, labour T&P etc. for completion of work.
58(a) 00.00 to 01.50 m
59(b) 01.50 to 03.00 m
60(c) 03.00 to 04.50 m
61Supply (excluding cartage) of granular material (well graded crushed rock or gravel of maximum size 20mm) for class B bedding (granular bedding)
62Construction of circular type brick masonry HD (HD20) manhole (with Extra Heavy Duty type manhole cover) with top slab made of cement concrete 1:1.5:3 with graded granite stone aggregate (12 mm nominal size), wall made of brick masonry using 1st class bricks having crushing strength between 100 to 149 kg/cm² in cement mortar 1:4 inside plastering 12 mm thick 1:4 finished smooth with neat cement, pinning, outside plaster 1:4 and making channels with cement concrete 1:2:4 graded granite stone aggregate (12 mm nominal size) complete as per specifications.
63900mm internal dia., 1.65m deep
641200mm internal dia., 2.30m deep
651500mm internal dia., 4.95m deep
661500mm internal dia., 9.0 m deep
671800mm internal dia., 9.0 m deep
68Extra for every additional depth of 1 m or part there of in following size of circular manholes.
69900mm internal dia., 1.65m deep
701200mm internal dia., 2.30m deep
711500mm internal dia., 4.95m deep
721500mm internal dia., 9.0 m deep
731800mm internal dia., 9.0 m deep
74Construction of Sewer Connecting chamber (0.6 x 0.6 x 3.0 m) including excavation, cement concrete (1:4:8) (40mm gauge) at the base, cement concrete (1:2:4) (20mm gauge), 1st class brick masonry (1:4), 12mm thick plaster inside the chamber and FRCS heavy duty manhole cover of size 0.6x0.6m all complete.
75Extra for every additional depth of 1 m to regulate the depth of SCC
76Dismantling/Cutting of the following type of road for laying sewers, manholes, sewer connection chambers etc. including shorting out and stacking serviceable materials and disposal of unserviceable materials upto distance of 50 m.
77Bituminous road
78Concrete road
79Interlocking tile road
80B.O.E road
81Reinstatement of the following type of road for laying sewers, manholes, sewer connection chambers etc. including shorting out and stacking serviceable materials and disposal of unserviceable materials upto distance of 50 m.
82Bituminous road
83Concrete road
84Interlocking tile road
85B.O.E road
86Tack & SDBC Coat on existing BT Road (remaining area after reinstatement)
87Provision for laying of sewer by trenchless technology
88Supply of MS pipe (As per IS:3589 made from steel confirming to IS:2062), with anti corrosive treatment with P.U. coating
891100 mm dia pipe,14mm Pipe Wall Thickness
90Installation of product pipe by HDD method including preparing and setting up the plants and equipement, preparing new pipe work material, installation new pipe-work and commissioning system or making the system ready for commissioning by HDD operation including, all related civil and mechanical works like excavation, shoring/strutting, etc. drilling, stringing, reaming, and pulling back the new pip-work on the designed bore path alignment, proper disposal of drilling fluid, and back fill of site after completion all inclusive as per IndSTT:101:2018: Code of prectice of HDD Technique Suiting Indian Conditions. (depth up to 6m. (IndSTT SOR: 2023)
911100 mm dia pipe
92Excavation of Entry and Exist pits beyond 3m depth and upto 5m depth - Excavation of non structural pits for pipe jacking/ramming purpose in soil inclusive of all shuttering, strutting, and shoring and maintaining the shaft during construction operation and backfilling the same after the completion of work.For shafts of 6mx5m upto a depth of 6m in all type of soil
93Providing and erecting temporary barricading at site as per drawing/ direction of Engineer-in-Charge which includes hiring of Ballies and arrangement for traffic diversion such as traffic signals during construction at site as directed by the Engineer-in-Charge. The barricading provided shall be retained in position at site continuously i/c shifting of barricading from one location to another location as many times as required during the execution of the entire work till its completion. Rate include its maintenance for damages, painting, all incidentals, labour materials, equipments and works required to execute the job. The barricading shall not be removed without prior approval of Engineer-in-Charge. (Note :- One time payment shall be made for providing barricading from start of work till completion of work i/c shifting. The barricading provided shall remain to be the property of the contractor on completion of the work). The rate is for unit length of pipe laying.
94Provision for shifting of existing water supply mains falling in the alignment of sewer line during excavation and the restoring utilities / services to its original condition. etc. during excavation and laying of sewer lines. (Cutting, reconnection, bailing out water etc. all complete) (2307)
95Schedule G (ii)Interception and Diversion (I&D)structure
96Interception and Diversion (I&D)structure (Outfall structure with 1 gate across the Drain and 1 gate at the diversion pipe inlet)
97Schedule G (iii)STP (10.6 MLD) with Co-Treatment (11.50 KLD)
98Design, Construction, Supply of all materials, Erection and Commissioning of STP with co treatment facilities (10.6 MLD Sewage Treatment Plant with 11.50 KLD Co-Treatment) with all the civil, electrical , mechanical, instrumentation and scada system, LT/HT panel, sub station building, DG set foundation, admin buidling, Staff quarter, compound development, laboratories, meter room etc. all complete for co-treatment facilities and including MPS (Civil works) and rising main. The quality of treated effluent shall be as per CPHEEO Manual/NGT Norms. The rate is based on SBR technology. The STP shall be able to treat the sewage and co-treatment of raw sewage having concentration level as per the CPHEEO Manual.
99Civil works
100Construction of Boundary Wall 1.8m ht. above plinth level with RCC Column @3m c/c with plinth beam and foundation avg. 1.2m depth including reinforcement and RCC coping on top of wall with plaster (1:4) and painting (apex painting 3 coat) as per type design and drawing at the STP site. As per type design and drawing.
101MS gate (3.6m wide gate)
102Construction of Internal Road (Bituminous Road)
103Schedule G (iv)SEWAGE PUMPING STATION - IPS
104Survey, Investigation including soil testing up to required depth, Design, Construction of Sewage Pumping Station and tapping arrangement of Intermediate Pumping station(Avg. Flow 11.94 MLD & Peak Flow 26.86 MLD),Sreen Chamber,H.T.room,L.T. Room, pannel Room,Site development works,internal roads path ways,Boundrywall other appurtenant works (Civil ) for proper completion of works as per required by Employer with Supply of All Labour,material & T&P Etc including Testing, Commissioning performance Trial run for 3 months on turnkey basis
105Schedule G (v)Sewage Rising main from IPS
106Excavating trenches for pipes including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering etc., and disposing of surplus excavated soil as directed, within a lead of 50 m.
1070.0 to 1.5 mtr. Depth ( in all kindes of soil - 100%)
1081.5 to 3.0 mtr. Depth
109Supply of 450mm dia. DI K9 pipe and special for the pumping mains including Cost of Supply and laying standard specials etc. all complete (@10%) and etc complete
110Pipes conforming to IS : 8329 - 450 mm
111Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid extra) (BIC Qtn. + 2449)
112Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (DSR 23, 18.59.3)
113100 mm
114Carting of 450mm dia DI K9 pipe and specials from store to the work lowering the same in to the trenches upto depth as specified below G.L. inclduing testing of pipes etc.
115Providing & Constructing masonry Chamber 1.5x1.5x1.5 m inside, in brick work in cement mortar 1:3 (1 cement : 3 coarse sand) for valve, with cast insitu RCC slab with necessary reinforcment.The valve chamber shall be plastered with CM 1:4, A levelling coars of M10 shall be provided.The cost is inclusive of excavation , disposal and construction of valve chamber with moduar bricks plasting with cement mortar with all lead and lift etc., as per specification & drawing.
116Sluice valve, Air valve chambers
117Dismantling/cutting of the following type of road for laying sewers, manholes, sewer connection chambers etc. including shorting out and stacking serviceable materials and disposal of unserviceable materials upto distance of 50 m.
118BT road
119Reinstatement of the following type of road for laying sewers, manholes, sewer connection chambers etc. including shorting out and stacking serviceable materials and disposal of unserviceable materials upto distance of 50 m.
120BT road
121Schedule G (vi)Treated effluent line - AC pipes
122Excavating trenches for pipes including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering etc., and disposing of surplus excavated soil as directed, within a lead of 50 m.
1230.0 to 1.5 mtr. Depth ( in all kindes of soil - 100%)
1241.5 to 3.0 mtr. Depth
125Supply of ISI Marked A.C. Pipe for sewerage and drainage confirming to IS-6908/1991 or itss latest amendment(s) including cost of one no. of AC coupling with a set of 3 rubber rings per meter length, including third party inspection charges, packing and forwaridng charges, transit insurance charges, road transportation charges etc. all complete. Class II (UPJN Rate)
126Pipes conforming to IS-6908/1991 - 600 mm
127Carting From Store, Laying, Jointing & Testing Class I & II A.C. Pipe With Fitting Etc. (600m Dia.) (2033)
128Dismantling/cutting of the following type of road for laying sewers, manholes, sewer connection chambers etc. including shorting out and stacking serviceable materials and disposal of unserviceable materials upto distance of 50 m.
129B.O.E road
130Reinstatement of the following type of road for laying sewers, manholes, sewer connection chambers etc. including shorting out and stacking serviceable materials and disposal of unserviceable materials upto distance of 50 m.
131B.O.E road
132Schedule G (vii)PART (B) -Electrical & Mechanical works at STP
133The complete Turnkey execution of 10.60 MLD SBR based STP with 11.50 KLD co-treatment facility, including manual fine screen, mechanical fine step screen, vortex grit removal system (1 Working + 1 Standby), SBR basins complete with fine bubble diffusers, decanter mechanism, submersible mixers, RAS & WAS pumps, aeration system, DI piping network, DI valves including motorized/electrically actuated sluice valves, screw press/sludge dewatering machine with sludge feed pump, complete chemical preparation and dosing system, online DO and MLSS sensors, radar level transmitters, pressure transmitters, motorized/electrically actuated arrangements for sluice valves at IPS and MPS, complete field instrumentation with junction boxes and cabling, complete Redundant PLC-SCADA system at IPS, MPS and STP including redundant PLC CPUs with auto synchronization, PLC-SCADA panels with HMI, SCADA server and client system, Motor Control System (MCS), 65” LED display screen, desktop computers/laptop with 32” monitor, SCADA software with mobile app facility, networking system and communication modules, air-conditioning for control room, OCEMS as per norms of Central Pollution Control Board (CPCB), complete HT and LT electrical system including outdoor substation with 1 Working + 1 Standby transformer sized for 100% MPS and STP load, HT panels, LT panels, MCC, PCC, DG set rated for 100% MPS and STP load with AMF panel, complete power and control cabling, earthing, lightning protection system, cable trays, transformer and DG foundations, substation fencing as per IER/CPWD specifications, complete campus lighting system including 01 No. High Mast Light, and all associated, incidental and ancillary works required for proper design, engineering, supply, installation, testing, commissioning and successful operation of the plant, including obtaining CTE, CTO and all statutory approvals.The item shall also include 03 months trial run and operation including chemicals, consumables and manpower, excluding electricity charges, and the work shall be treated as complete in all respects on Turnkey basis. No extra claim shall be admissible for any item necessary for successful completion and operation of the STP. The contractor shall submit item-wise BOQ breakup covering all equipment, systems and associated works to the Department for scrutiny and approval prior to execution.
134Electrical & Mechanical works at Main Pumping Station (MPS)
135Supply of submersible sewage bottom suction non clog Pumpsets having Speed 1460 RPM & Bearing insulation should be compatible for VFD operation and handling raw sewage of Sp. Gr. 1.05 with Pumpset accessories such as duck foot bend,Pedestal auto coupling with Guide rail system of SS 316 submersible pump sets comprises of guide pipe, bracket, upper guide rail holder and lifting chain with D-Sackle etc complete and Material of Construction shall be-:Casing- 2% Ni-CI with hardness ranges 220- 275 BHN approx, Impeller - Super duplex steel , Hardness 220-260 BHN.,Shaft- SS 410 with ceremic coating, hardness 700 BHN at the minimum.,Bearing- anti frictional L-10 with 60000 hours life.Operational Voltage 380±10% 3 phase AC Supply. The duties of pumpsets as follows -: (NOTE- Pump Discharge, Head & motor HP are tentative and may vary as per actual site condition at the time of execution.)Capacity- Discharge- 73 LPS at Head- 21 Mtr. with suitable rating motor)
136Supply of VFD Starter Control Panel with push button suitable for operation on 415V ±6% ,3 phase, 50 Hz, AC supply with semiconductor fuse set and, all necessary MCB switchgears, controlgears and protections along with automatic power factor correction feature and also compatible to PLC based SCADA Automation operation and suitable to operate 40 HP / above rating Pumping Plant (Use which ever is higher)
137Supply of Manually operated CIDF Rising spindle type Sluice valve with integral starter & gearbox PN 1.0 having body door, dome gland in graded cast iron, four faces and spindle nut of Bronze LTB 2 Spindle of St. Steel 410 and specifications should be as per relevant I.S. of following sizes.
138200 mm dia
139400 mm dia for common header
140Supply of CIDF double flanged single/multi door swing check/reflex valves PN 1.0 having body comprising inlet & outlet sheets in gradeed cast iron diaphragm fitted woth st. steel, faces,diaphragm plate and door , sub pins and specifications should be as per relevant I.S.&shall be of following sizes:
141200 mm dia
142400 mm dia for common header
143CI Dismantling joints of following sizes.
144200 mm dia
145400 mm dia for common header
146Supply of Cast iron pipes & specials.CIDF Pipe dia 200 mm - 66 Mtr. CIDF Pipe dia 400 mm - 6 Mtr. CIAF Tee 400x200x400 mm - 6 Nos.CI blind flange dia 400x400 mm - 1 No.CIDF 90 degree bend dia 200 mm - 6 Nos.CIDF 90 degree bend dia 400 mm - 2 Nos.CIDF 90 degree duckfoot bend dia 200 mm - 6 Nos.CIDF Reducer/Enlarger 100 mmx 200 mm - 6 Nos.(Note-All items, materials, fittings and accessories required for complete delivery line and common header system shall be deemed to be included in the scope of this work, and any additional item required for proper installation, testing and commissioning of the system shall also be included in this work, and no extra item, claim or payment whatsoever shall be admissible on this account.)
147Supply of Nut- Bolt SS-304 and rubber packing material for erection of suitable sizes.
148Supply of Manually operated Open Channel sluice Gate in CI with gearbox, single faces rising spindle type generally conforrming to releavant IS , having frame & door fitted with St. Steel faces M.S extension rod with coupling and Guide brackets suitable to a required distance size suitable for 900x900 mm. cutout size at the inlet & outlet of screen chamber as per site requirement. (Note : Size is tentative and may vary as per actual site conditions.)
149Supply of Manually operated Thimble Mounted CI Sluice Gates of rising spindle type with gearbox, suitable for 1100mm. dia incoming sewer as per site requirement.(Note : Size is tentative and may vary as per actual site conditions.)
150Supply of Manual S.S.316 bar coarse screen 1.50 x 1.20 meter size having spacing 20 mm , thickness 10 mm as per site requirement.(Note : Size is tentative and may vary as per actual site conditions.)
151Supply of Mechanical multi racked SS 316 coarse screen 6.00 x 1.20 meter size having spacing 20 mm, Bar size 50x10 mm with conveyor system driven by motor , Dead plate 4mm thick, chain sprocket SS 316 , Ultrasonic type differential level sensor, Control Panel Coarse bar screen and Belt conveyor 600x2000mm or as per site requirement.(Note : Size is tentative and may vary as per actual site conditions.)
152Supply of E.O.T. crane of 3 Tonne capacity along with gantry girders, chain pulley block and geared trolley suitable for 10 m span 16m clear lift complete in all respect.
153150 mm dia 0-6 Kg/ sq cm. digital pressure guage with S.S. tubing stop cock and necessary fittings.
154Supply, Design, fabrication, assembly, internal wiring, installation, testing and commissioning of floor mounted, cubicle type, free standing L.T. Panel Board fabricated from 2 mm thick CRCA sheet steel with 3 mm thick gland plate, suitable for operation on 415 Volt, 3 Phase, 50 Hz A.C. supply, conforming to IEC-60439 (latest edition), powder coated after proper surface treatment, complete with cable alley, detachable gland plates, earthing bus, danger notice plate and all standard accessories, having suitably rated high conductivity Aluminium bus bars of adequate ampacity with neutral bus of 50% capacity of phase bus, sectionalized bus section, short circuit withstand capacity not less than 36 kA, comprising 02 Nos. 4 Pole MCCB incomers of 36 kA breaking capacity microprocessor based (01 No. for Mains and 01 No. for DG Set), complete with one set of CTs of suitable ratio, CT operated ammeter with selector switch, voltmeter 0–500V with selector switch, power factor meter (0.5 lag – 1 – 0.5 lead), frequency meter, surge protection relay, under voltage and over voltage relay, 06 Nos. 160A MCCB of 25 kA breaking capacity for pump feeders complete with mechanical ON/OFF indicator, R-Y-B indication lamps, ammeter with selector switch, single phasing preventer, overload and underload relays, timer and auxiliary relays, multifunction digital energy meter with RS-485 communication for each pump feeder, 01 No. 63A MCCB for lighting load, 01 No. 63A MCCB for miscellaneous load, 02 Nos. 32A MCCB as spare, 02 Nos. 32A MCCB with auto operation provision for APFC panel, complete with copper control wiring, terminal blocks, ferruling, labeling, earthing terminals etc.
155Supply of Electromagnetic type Full-Bore Flowmeter 400 mm dia shall be suitable for bi directional flow measurement. This shall be having protection category of the sensor shall be IP68 and protection category for the transmitter shall be IP- 65. Accuracy shall be of +/- 5% of measured value without being affected by variation in the line pressure. Equipment should be complete with converter, transmitting device and should be fully programmable with digital flow indicator & integrator etc. The sensor housing and junction box should be of SS 316. complete with control cable and display with application in Sewage .
156Power and control cables
157Supply of 1100 V grade, 3.5/4 core x 25mm2 PVC insulated PVC sheathed Aluminium Armoured conductor cable from LT panel to juction box.(1x6x40 mtr.)
158Supply of 1100V grade, 2Rx3C x16 mm2 PVC insulated PVC sheathed submersible Copper flat cable from junction box to motor. (2x6x30 mtr.)
159Supply of Control cable 1*10C, 1.5 mm2 PVC insulated PVC sheathed copper conductor cable for moisture sensor, level sensor, Reverse protection thermistor relay etc.(40m. For each) X 6 Nos.pumps
160Supply of Al. junction box in SS304, IP65 with instruments for pumps with Busbar.
161Supply of 1100 V grade, 2Rx3.5Cx185mm2 , XLPE insulated Aluminium Armoured conductor cable from Common LT distribution panel to MPS LT Panel.
162EARTHING
163Complete earthing of all the equipments as detailed above shall be done as per IS/IER/PWD specification with G.I Plates, watering pipe and loop earthing with adequate size of G.I/ Al. strip etc. (PS-702) 14 pits for Pumps &. LT Panel. Size of earthing plate 600mm x 600mm x6 mm with salt and coal.
164Lighting system:
165Supply & erection of M.S. Tubular Poles SP-36, 9.5 M height.
166Supply of S/F of 72 watt LED with lumen reflector.
167Supply of Feeder pillar for lighting
168Supply and laying of 4x16mm2 Al. armoured cable.
169Supply and fixing of 280x170x130 mm.size sintex junction boxes on poles.
170Supply and laying of unarmoured cable 6 mm2 core Flat PVC insulated for connection of LED to junction boxes.
171Supply of Internal electrification with fixtures.
172S/F 1200 mm ceiling Fan for LT Room
173S/F of exhaust Fan for LT Room.& Other rooms.
174S/F of Earthing of street light pole (SOR-41)
175Painting of street light (P5-634)
176Supply and installation of DCP type of 5 Kg. Fire existinguisher(PS-1132)
177Supply of 12 mm thick rubber mating for safe working on.
178Tools
179Hydrulic crimping tools-Crimping range: 16-300 sq.mm.,Weight: 6 Kg. ,Length: 500mm,Make/ Model:YQK300
180Mannual crimping tools-Crimping range: 400 sq.mm.,Make/ Model: Crimp well
181Tong tester (AC/DC-1000A, make-Rishabh)Multimeter (AC/DC-1000A, make-Meco)Megger (AC/DC-500V make-Rishabh)Screwdriver (6\\"x 12\\", make- Taparia)Plier (250mm, make-Taparia)
182Chain wrench (12\\"x18\\", make Taparia) Pipe wrench (1200mm, make Taparia)
183Supply of CE & UL certified Hydrostatic type level transmitter for MPS Sump.
184Chequered plate of required size so as to cover all trenches.
185Testing of all above E/M Items of MPS at O.E.M. Place.
186Installation, testing and Commissioning of all electrical, mechanical and associated works etc. complete in all respect as per IS & IER rule of MPS.
187Electrical & Mechanical works at Intermediacte Pumping Station (IPS)
188Supply of submersible sewage bottom suction non clog Pumpsets having Speed 1460 RPM & Bearing insulation should be compatible for VFD operation and handling raw sewage of Sp. Gr. 1.05 with Pumpset accessories such as duck foot bend,Pedestal auto coupling with Guide rail system of SS 316 submersible pump sets comprises of guide pipe, bracket, upper guide rail holder and lifting chain with D-Sackle etc complete and Material of Construction shall be-:Casing- 2% Ni-CI with hardness ranges 220- 275 BHN approx, Impeller - Super duplex steel , Hardness 220-260 BHN.,Shaft- SS 410 with ceremic coating, hardness 700 BHN at the minimum.,Bearing- anti frictional L-10 with 60000 hours life.Operational Voltage 380±10% 3 phase AC Supply. The duties of pumpsets as follows -: (NOTE- Pump Discharge, Head & motor HP are tentative and may vary as per actual site condition at the time of execution.)Capacity- Discharge- 30 LPS at Head- 20 Mtr. with suitable rating motor)
189Supply of VFD Starter Control Panel with push button suitable for operation on 415V ±6% ,3 phase, 50 Hz, AC supply with semiconductor fuse set and, all necessary MCB switchgears, controlgears and protections along with automatic power factor correction feature and also compatible to PLC based SCADA Automation operation and suitable to operate 20 HP / above rating Pumping Plant (Use which ever is higher)
190Supply of Manually Operated CIDF Rising spindle type Sluice valve with integral starter & gearbox PN 1.0 having body door, dome gland in graded cast iron, four faces and spindle nut of Bronze LTB 2 Spindle of St. Steel 410 and specifications should be as per relevant I.S. of following sizes.
191150 mm dia
192250 mm dia for common header
193Cast iron pipes & specials.CIDF Pipe dia 150 mm - 51 Mtr. CIDF Pipe dia 250 mm - 12 Mtr.CIAF Tee 250x150x250 mm - 6 Nos.CI blind flange dia 250 mm - 1 No.CIDF 90 degree bend dia 150 mm - 6 Nos.CIDF 90 degree bend dia 250 mm - 1 No.CIDF 90 degree duckfoot bend dia 150 mm - 6 Nos.CIDF Reducer/Enlarger 100 mmx 150 mm - 6 Nos. (Note-All items, materials, fittings and accessories required for complete delivery line and common header system shall be deemed to be included in the scope of this work, and any additional item required for proper installation, testing and commissioning of the system shall also be included in this work, and no extra item, claim or payment whatsoever shall be admissible on this account.)
194Supply of Nut- Bolt SS-304 and rubber packing material for erection of suitable sizes.
195Supply of CIDF double flanged single/multi door swing check/Reflex valves PN 1.0 having body comprising inlet & outlet sheets in gradeed cast iron diaphragm fitted woth st. steel, faces,diaphragm plate and door , sub pins and specifications should be as per relevant I.S.&shall be of following sizes:
196150 mm dia
197250 mm dia for common header
198CI Dismantling joints
199150 mm dia
200250 mm dia for common header
201Supply of manually operated Open Channel sluice Gate in CI with gearbox, single faces rising spindle type generally conforrming to releavant IS , having frame & door fitted with St. Steel faces M.S extension rod with coupling and Guide brackets suitable to a required distance size suitable for 800x800 mm. cutout size at the inlet & outlet of screen chamber as per site requirement. (Note : Size is tentative and may vary as per actual site conditions.)
202Supply of manually operated Thimble Mounted CI Sluice Gates of rising spindle type with gearbox, suitable for 1000mm. dia incoming sewer as per site requirement.(Note : Size is tentative and may vary as per actual site conditions.)
203Supply of Manual S.S.316 bar coarse screen 1.25 x 0.6 meter size having spacing 20 mm , thickness 10 mm as per site requirement.(Note : Size is tentative and may vary as per actual site conditions.)
204Supply of Mechanical multi racked SS 316 coarse screen 6.00 x 1.0 meter size having spacing 20 mm, bar size 50x10 mm with conveyor system driven by motor , Dead plate 4mm thick, chain sprocket SS 316 , Ultrasonic type differential level sensor, Control Panel Coarse bar screen and Belt conveyor 600x2000mm or as per site requirement.(Note : Size is tentative and may vary as per actual site conditions.)
205Supply of E.O.T. crane of 3 Tonne capacity along with gantry girders, chain pulley block and geared trolley suitable for 10 m span 16m clear lift complete in all respect for IPS
206Supply of 150 mm dia 0-6 Kg/ sq cm. digital pressure guage with S.S. tubing stop cock and necessary fittings.
207Supply of Electromagnetic type Full-Bore Flowmeter 250 mm dia shall be suitable for bi directional flow measurement. This shall be having protection category of the sensor shall be IP68 and protection category for the transmitter shall be IP- 65. Accuracy shall be of +/- 5% of measured value without being affected by variation in the line pressure. Equipment should be complete with converter, transmitting device and should be fully programmable with digital flow indicator & integrator etc. The sensor housing and junction box should be of SS 316. complete with control cable and display with application in Sewage .
208L.T. Panel Board Conforming to IEC-60439
209Supply, Design, fabrication, assembly, internal wiring, installation, testing and commissioning of floor mounted, cubicle type, free standing L.T. Panel Board fabricated from 2 mm thick CRCA sheet steel with 3 mm thick gland plate, suitable for operation on 415 Volt, 3 Phase, 50 Hz A.C. supply, conforming to IEC-60439 (latest edition), powder coated after proper surface treatment, complete with cable alley, detachable gland plates, earthing bus, danger notice plate and all standard accessories, having suitably rated high conductivity Aluminium bus bars of adequate ampacity with neutral bus of 50% capacity of phase bus, sectionalized bus section, short circuit withstand capacity not less than 36 kA, comprising 03 Nos. 4 Pole MCCB incomers of 36 kA breaking capacity microprocessor based (02 No. for Transformer Mains and 01 No. for DG Set), complete with one set of CTs of suitable ratio, CT operated ammeter with selector switch, voltmeter 0–500V with selector switch, power factor meter (0.5 lag – 1 – 0.5 lead), frequency meter, surge protection relay, under voltage and over voltage relay, 06 Nos. 160A MCCB of 25 kA breaking capacity for pump feeders complete with mechanical ON/OFF indicator, R-Y-B indication lamps, ammeter with selector switch, single phasing preventer, overload and underload relays, timer and auxiliary relays, multifunction digital energy meter with RS-485 communication for each pump feeder, 01 No. 63A MCCB for lighting load, 01 No. 63A MCCB for miscellaneous load, 02 Nos. 32A MCCB as spare, 02 Nos. 32A MCCB with auto operation provision for APFC panel, complete with copper control wiring, terminal blocks, ferruling, labeling, earthing terminals etc.
210Power and control cables
211Supply of 1100 V grade, 3.5 core x25mm2 PVC insulated PVC sheathed Aluminium Armoured conductor cable from LT panel to juction box.(1x6x40 mtr.)
212Supply of 1100V grade, 2Rx3C x16 mm2 PVC insulated PVC sheathed submersible copper flat cable from junction box to motor. (2x6x30 mtr.)
213Supply of Control cable 1*10C, 1.5 mm2 PVC insulated PVC sheathed copper conductor cable for moisture sensor, level sensor, Reverse protection thermistor relay etc.(40m. For each) X 6 Nos.pumps
214Supply of Al. junction box in SS304, IP65 with instruments for pumps with Busbar.
215EARTHING
216Complete earthing of all the equipments as detailed above shall be done as per IS/IER/PWD specification with G.I Plates, watering pipe and loop earthing with adequate size of G.I/ Al. strip etc. (PS-702) 12 pits for Pumps &. LT Panel. Size of earthing plate 600mm x 600mm x6 mm with salt and coal.
217Lighting system:
218Supply & erection of M.S. Tubular Poles SP-36, 9.5 M height.
219S/F of 72 watt LED with lumen reflector.
220Supply of Feeder pillar for lighting
221Supply and laying of 4x16mm2 Al. armoured cable.
222Supply and fixing of 280x170x130 mm.size sintex junction boxes on poles.
223Supply and laying of unarmoured cable 6 mm2 core Flat PVC insulated for connection of LED to junction boxes.
224Internal electrification with fixtures.
225S/F 1200 mm ceiling Fan for LT Room
226S/F of exhaust Fan for LT Room.& Other rooms.
227Earthing of street light pole (SOR-41)
228Painting of street light (P5-634)
229Supply and installation of DCP type of 5 Kg. Fire existinguisher(PS-1132)
230Supply of 12 mm thick rubber mating for safe working on.
231Tools
232Hydrulic crimping tools-Crimping range: 16-300 sq.mm.,Weight: 6 Kg. ,Length: 500mm,Make/ Model:YQK300
233Mannual crimping tools-Crimping range: 400 sq.mm.,Make/ Model: Crimp well
234Tong tester (AC/DC-1000A, make-Rishabh)Multimeter (AC/DC-1000A, make-Meco)Megger (AC/DC-500V make-Rishabh)Screwdriver (6\\"x 12\\", make- Taparia)Plier (250mm, make-Taparia)
235Chain wrench (12\\"x18\\", make Taparia) Pipe wrench (1200mm, make Taparia)
236Supply of CE & UL certified Hydrostatic type level transmitter for IPS Sump.
237Chequered plate of required size so as to cover all trenches.
238Testing of all above E/M Items of IPS at O.E.M. Place.
239Installation, testing and Commissioning of all electrical, mechanical and associated works etc. complete in all respect as per IS & IER rule of IPS.
240Supply of 125 KVA silent type DG set rated capacity at 415 V +/- 6% 50 Hz A.C. Supply of 0.8 P.F lag. Self exciting alternator coupled with 1500 RPM diesel engine of suitable BHP and AC brushless SPDP alternator mounted on a common base frame and coupled through flexible coupling or closed coupled. Alternator shall be self regulated with over voltage, over speed and under voltage standard protection. Engines shall have silencer upto 10 mtr. exhaust piping, electronic/mechanical governor, manual and electric start, batteries, fueled tank with stand and piping, control panel (16G) wirh MCCB (4P, 25 KA) Ammeter, voltmeter, frequency meter, energy meter, hour meter, engine instrument panel, AVM pads and with wheather proof, powder coated Accoustic Enclosure for DG set for sound attenuation febricated from 2.0mm CRCA sheet steel structure with side wall febricated from 2.0mm CRCA sheet and filled with 100mm thick glass wool as per IS the doors of 100mm thick and febricated from 1.6mm CRCA sheet, Floor of MS chequrred Plate 5.0mm thick, canopy fixed with axial flow fan of alstom, CG, Almonard make. The enclosure has protection and Tripping of DG set against temprature of more than 50 degree centigrade. All controls for operation of DG set are from outside the enclosure with DG control panel mounted inside enclosure. The enclosure should be suitable for over mentioned capacity of DG set and Alternator.Method of cooling- water,Method of Aspirartion- Turbo Charged as per CPCB 4 guidlines.
241Supply of Auto Mains Failure Panel (AMF) fabricated from CRCA sheet steel 2mm thick power coated finished, start and stop commands, control relays, selectors switch for ammeter and voltmeter, timers, hooter, visual and alarm indication for faults, UPS, operator inter face panel complete in all respect suitable for above DG sets.
242Supply and laying of 1100 voltage grade,1x3.5Cx120 mm2 Al. conductor, XLPE insulation , armoured cable from DG terminal to DG Panel & from DG Panel to LT Panel.
243Installation, testing and Commissioning of D.G. Set & AMF.Panel with Double Earthing works complete with Al. strip size 25X6mm , complete as per IS & IER.
244Power Distribution Transformer :
245Supply of Oil immersed Outdoor type Power distribution transformer 11/0.433 KV rating 160 KVA double wound with copper winding, Level-1, vector group dyn 11, ONAN with OFF LOAD tap changer operated for voltage variation + 5.0 % to - 10% at 07 tap positions in step of 2.5% along with its R.T.C.C. Panel complete with standard fitting & accessories incorporated with Marshall box for OTI,WTI & Buchholz relay etc.
246Supply and laying of 1100 voltage grade,1x3.5Cx150 mm2 Aluminium conductor, XLPE armoured cable from transformer to LT Panel.
247Double Earthing of Transformers consisting of 04 nos. Earthing Pit (two for each neutral and body) with Al/GI. strip size 25X6mm, the minimum distance between to earthing pits, Double Earthing works and all electrical equipments shall be as per IS and IER.
248H.T. Switch Gear Panel :
249Supply of 12 KV, H.T. V.C.B. Panel with one incoming & two out going ,630Amp. (25 KA) Rating have followings-Incommer Feeder- 01 No.3 O/C + 1 EF IDMT Characteristics Relays based Incommer control panel equiped with over current & earth fault relay with core balance C.T., master trip relay, instantaneous under voltage realy & Auxilliary realy etc. C.T.ratio 50-40/5A Dual core, Class-1 for measurement core & 5P10 for protection core & PT 11KV/110 VAC. KWH meter, power factor meter, frequency meter. Amp. meter 0-50 & volt meter 0 to12 KV. All relays required separately conventioal type 24 to 30 VDC, 110 VAC.Outgoing Feeder- 02 Nos.Outgoing feeder control panel equiped with triple pole 3 O/C + 1 E/F relay with IDMT & intantaneous characteristics, mater trip relay & Auxilliary relay for Buchhloz alarm / trip, OTI alram / trip & WTI alram/trip, etc. C.T.ratio 50-40/5A, Class-1 for measurement core & 5P10 for protection core.DC Supply SICT battery bank, exide make, consisting of 16 cells, 2 volt each for supply VDC 24 to 30 Volt with battery charger of approved make with suitable M.S. Stand / Trolley, equipment fittings with accessories etc.
250Supply and laying of 1x3Cx95 mm 2 ,11 KV HT Al. Cable XLPE insulation from metering panel to H.T. Panel and from H.T. Panel to both transformers.
251S/F of XLPE cable End termination box of 120/150mm2 :
252Indoor end termination box.
253Earthing of H.T Panel as per IS & IER.
254Installation of HT Panel.
255Testing & Commissioning of HT Panel etc.
256S.I.T.C. of 11 KV, T.P.M.O manually operated in double pole Structure with G.O. Switch, Double Pole Isolator(D.P.I), A.B. Switch along with all required necessary material & fittings at the outside of entry of Plant in case of isolating the Grid supply at the event of fault occurs in Substation.
257Installation, testing & comissioning of Substation equipment, Transformer, HT/LT panel, DG set etc complete with fencing with iron mesh as per IER and IS code complete in all respect.
258Diesel & Lubricants for MPS with STP for 03 months Trial & Run (excluding electricity)
259Diesel & Lubricants for IPS for 03 months Trial & Run (excluding electricity) Please Enable Macros to View BoQ information

Other Detail

Information Source https://etender.up.nic.in
Download FileName File Description File Size
Download 979376cf-4532-4785-af63-39dd8b707713.html Tender Documents 0 KB
Download BOQ_2166266.xls Tender Documents 0 KB
Download TENDERDOCUMENTDADRI.pdf Tender Documents 0 KB
Download Tendernotice_1 (19).pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.