Indian Tenders

Tender Notice

TDR 55759281
Tendering Authority Public Works Department
Tender No 2026428146DA 54B1 4D9A B1E7 6CAEC3D9150B668BAR
Tender ID 2026_HRY_525890_1
Tender Brief Tender For Construction Of Adr Centre At Rewari District (Pdg. Additional Air Conditioners Only)..
City Rewari
State Haryana
Document Fees INR 1500 /-
EMD INR 3400.0 /-
Tender Value INR 1.70 Lakhs /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Construction Of Adr Centre At Rewari District (Pdg. Additional Air Conditioners Only)..

Key Dates

Publish Date 01-06-2026
Last Date of Bid Submission 08-06-2026
Tender Opening Date 09-06-2026

Contact Information

Company Name Public Works Department
Contact Person RAVI Ladwal
Address ED - Rewari

BOQ Items

Name of Work:- Construction of ADR Centre at Rewari District (Pdg. Additional Air Conditioners only)..
Sl. No. Item Description
1[23.22.5.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole [Through Rate]
2[23.3.6.3]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.3. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 4 Sqmm(1/2.24mm) [Through Rate]
3S.I.T.C of UPVC hard Drain Pipe Make: Ploypack, AKG, Dplast.
4Supply and erection of Power unit with 25Amp. MCB and 16 Amp. Plug along with surface box, 3 pin top etc. made of fire retardant material plastic along with cover plate (modular type) 3M to be installed on surface/recess upto entire satisfaction of Engineer-in-charge of the work.
5Supply and fixing of hinging type MS stand (Platform frame made out angle iron along with vibration pad, Threaded rod (Sariya) and fasteners.) MS stand platform will be painted with one coat primer and two coat of epoxy paint.
6S.I.T.C of 60X60 mm PVC batten Heavy duty (in spl. White color) with clamping.
7S.I.T.C of flexible pipe 2` white heavy duty.
8S.IT.C of 4 Core 2.5sqmm copper wire ISI mark Make Plaza / Havells / Polycab / R.R. Kabel / KEI
9HI WALL SPLIT SYSTEMSSupply , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low and high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature).Inverter Type - Cooling only2.0 TR with 5 Star BEE Rating (New HSR 25.17.2.4)
10COPPER REFRIGERANT PIPINGSupplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitableadjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm (New HSR 23.35.14.4)
11COPPER REFRIGERANT PIPINGSupplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitableadjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm (New HSR 23.35.14.1)
12S.I.T.C. of 5 KVA voltage stabilizer copper wound with 170 upto 270. Suitable for operation on 230V, Hz-10% 50Hz 1 phase AC supply Make Blue bird/V-guard/Blue guard Please Enable Macros to View BoQ information

Other Detail

Information Source https://etenders.hry.nic.in
Download FileName File Description File Size
Download ac8a3f9f-47c6-408f-9a72-261b6996d2e6.html Tender Documents 0 KB
Download BOQ_604857.xls Tender Documents 0 KB
Download Tendernotice_1 (10).pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.