Tendering Authority Madhyanchal Vidut Vitran Nigam Limited
Tender No TENDER NO. 18/EDCR-II,R/2026-27
Tender ID 2026_MVVNL_1156120_1
Tender Brief Corrigendum : Tender For Schedule Of Rates & Quantum Of Work For (1) Erection Of 02 Nos 11/0.4 Kv Sub Stations For Installation Of 250 Kva Transformers At A Place Shanti Nagar And Kanpur Road, Lalgnaj. Raebareli. (2) Erection Of 06 Nos 11/0.4 Kv Sub Station For Ne
City Lalganj
State Uttar Pradesh
Document Fees INR 3540 /-
EMD INR 18500.0 /-
Tender Value INR 18.50 Lakhs /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Schedule Of Rates & Quantum Of Work For (1) Erection Of 02 Nos 11/0.4 Kv Sub Stations For Installation Of 250 Kva Transformers At A Place Shanti Nagar And Kanpur Road, Lalgnaj. Raebareli. (2) Erection Of 06 Nos 11/0.4 Kv Sub Station For New Installation Of 100 Kva Transformers At A Place Paushala, Mahesh Nagar, Gandhi Chauraha, Saket Nagar, Gandi Gali And Baghel Hospital, Lalganj, Under Geographical Area Of Electricity Distribution Division-Lalganj Raebareli, In Juriduction Of Executive Engineer, Electricity Distribution Division- Lalganj Raebareli.

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 19-06-2026 dt ext Date 23-06-2026
2 15-06-2026 EXETENSION Date 19-06-2026
3 15-06-2026 EXETENSION Date 19-06-2026
4 09-06-2026 DATE EXT Date 15-06-2026
5 09-06-2026 DATE EXT Date 15-06-2026

Key Dates

Publish Date 19-06-2026
Last Date of Bid Submission 23-06-2026
Tender Opening Date 23-06-2026

Contact Information

Company Name Madhyanchal Vidut Vitran Nigam Limited
Contact Person SE EDC II GORA BAZAR RAEBARELI
Address OFFICE OF SE EDC II GORA BAZAR RAEBARELI

BOQ Items

Name of Work:- SCHEDULE OF RATES & QUANTUM OF WORK FOR (1) ERECTION OF 02 NOS 11/0.4 KV SUB STATIONS FOR INSTALLATION OF 250 KVA TRANSFORMERS AT A PLACE SHANTI NAGAR AND KANPUR ROAD, LALGNAJ. RAEBARELI. (2) ERECTION OF 06 NOS 11/0.4 KV SUB STATION FOR NEW INSTALLATION OF 100 KVA TRANSFORMERS AT A PLACE PAUSHALA, MAHESH NAGAR, GANDHI CHAURAHA, SAKET NAGAR, GANDI GALI AND BAGHEL HOSPITAL, LALGANJ, UNDER GEOGRAPHICAL AREA OF ELECTRICITY DISTRIBUTION DIVISION-LALGANJ RAEBARELI, IN JURIDUCTION OF EXECUTIVE ENGINEER, ELECTRICITY DISTRIBUTION DIVISION- LALGANJ RAEBARELI.
Sl. No. Item Description
1Safe loading & carriage including Loading-Unloading & proper stacking at a Place of work site of following store materials from ESC Tripula to site of work:-
2250 KVA T/F
3100 KVA T/F
4PCC Pole 8.5 Mtr.
5MS Dropper Channel (100X50X2028 mm)
6MS Angle 75x75x6x2028 mm for Fuse Set
7MS Top Channel (125X65X2240 mm)
811 KV T&C Type 4500 KG Disc Insulator
911 KV T&C Type 4500 KG Disc Fitting
10MS \\"T\\" OFF Channel (125X65X1300 MM)
1111 KV Pin Insulator with fitting
1211 KV TPMO Set
1311 KV Fuse Set
14LT PVC Cable 3.5x400 Sq.mm
15LT PVC Cable 3.5x150/70 Sq.mm
16Stay Set Complete (16X1800)
17Earthing of PCC/ST Pole, with Earthing Rod 20x2500 mm, and 6 SWG Earthing wire etc.. As per RESPO Norms.
18LT ABC (3X120+1X70+1X16) sq.mm
19ASCR Weasal Conductor
20ASCR DOG Conductor
2111 KV \\"V\\" Type X-Arms
22Labour Ereection Charges:-
23Digging of pits of PCC Pole 8.5 Mtr. Long from dump site to pit site then errection of PCC poles with fitting of all related accessories as per RESPO Norms.
24Grouting of PCC poles 8.5 Mtr. along with grouting materials as per RESPO Norms.
25Making/Prapairing of double pole structure by.PCC Pole then Pole grouting with grouting materials and earthinh including fitting of all equired accessories items, as per RESPO Norms.
26Earthing of Pole with Complet fitting of all accessories
27Earthing of T/F Body & Neutral alongwith fitting of All accessories, as per RESPO Norm.
28Digging of Pits, fixing nozzling & grouting of Stay Rod inclucing fitting of all accessories with grouting materials as per RESSPO Norms
29Laying , stringing & sagging of HT Line by ACSR weasal conductor including all associated work & making clearance of Road with Joint/jumpers & binding on insulators as required.
30Laying , stringing & sagging of HT Line by ACSR DOG Conductor including all associated work & making clearance of Road with Joint/jumpers & binding on insulators as required.
31The work for excavation of new Plinth size 2.00X2.00X1.50 for Mounting of 250 KVA T/Fs, under BUSINESS PLAN 2026-27, making outer wall of Plinth by 1st class brick work in Cement mortar of ratio1:6 of filling earth in Plinth and providing Stone ballast and then plastering the top and all side of plinth wall with cement Corse and sand in ratio 1:4 and then proper spraying of water alongwith fitting of all accessories, As per RESPO Norms. All required materials & Labour will be provided by Contractors in own resourses.
32Mounting of 100 KVA Transformer on new Constracted double pole alongwith fitting of all acessories as per RESPO Norms.
33Labour Charges for earthing of 250 KVA 11/0.4 KV Power Transformers completed for digging of 60 fit Borewell type pit (1.5-inch diameter) to install 60 fit long M.S. Pipe (60 fit long) with 1.5-inch diameter work followed by connection of M.S. Stirp 50X6 mm size for Suitable length to G.I. Pipe through proper welding ( Aluminium paint covering of welded joint) with tightening of nuts & bolts and fitting of spaces by homogeneous mixture of coke & sault against medium power transformer includes connection of M.S Strip for sepret common pit as there will be one pit of each earthing. All required material will be provided by contractor.
34Making/Errection/Installation/painting/gouting/welding/febrication/earthig work of Wirmesh Fancing of Jali alongwith Angle isn size of 35X35X5X2500 mm with Nut & Bolts, Washer, Earthing Rod & G.I. wire. Making of 01 No. Gate by M.S. Angle in size of 35X35X5X1000 mm with Nut & Bolts Washer, Earthing Rod & G.I. wire. One No. Gate of M/S Angle in size of 25X5 mm with wiremesh and each of the same. Grouting of M.S. Angle and other required Angles with Grouting materials as per RESPO Norms, under BUSINESS PLAN 2023-24. All required material will be provided by contractor.
35work for Installtion/Mounting/Instaiiation of MS Dropper Channel (100X50X2028 mm) as per RESPO Norms.
36work for Installtion/Mounting/Instaiiation of MS Top Channel (125X65X2240 mm)
37work for Installtion/Mounting/Instaiiation of 11 KV T&C Type 4500 KG Disc Insulator
38work for Installtion/Mounting/Instaiiation of MS \\"T\\" OFF Channel (125X65X1300 MM)
39work for Installtion/Mounting/Instaiiation of 11 KV TPMO Set.
40Laying , stringing & sagging of LT Line by LT ABC 3X120+1X70+1X16 including all associated work & making clearance of Road with Joint/jumpers & binding on insulators as required.
41work for Laying/Installtion/Fixing of 11 KV LT PVC Cable 3.5x400 Sq.mm
42work forLaying/ Installtion/Fixing of LT PVC Cable 3.5x1.50/70 Sq.mm0 Sq.mm
43work for Installtion/Fixing of 11 KV \\"V\\" Type X-Arms
44work for Installtion/Mounting of Ston Pad (3X300X300X75)mm, Material Provided by Contractor
45work for Jointing/Fixing/Instaiiation of LT Fuse Set in (SMC BOX, Material Provided by Contractor
46work for Installtion/Fixing/Tightening of Holding Clamp, Material Provided by Contractor
47work for Installtion/Fixing/Tightening of Cooper Piece 50x225x10mm), Material Provided by Contractor
48work for Installtion/FixingTightening of Cooper Piece 65x225x12mm), Material Provided by Contractor
49work for Installtion/Fixing/Tightening of AL.Lug Long Barrel off size (LS), Material Provided by Contractor
50work for Installtion/Fixing/Tightening of Henly Type Tailless Unit for 250 KVA T/F, Material Provided by Contractor
51work for Fixing/Instaiiation/Tightening of Suspension Clamp t for 250 KVA T/F, Material Provided by Contractor
52work for Fixing/Instaiiation/Tightening of \\"I\\" Hook with Suspension Clamp, Material Provided by Contractor
53work for Tightening/Fixing/Instaiiation of \\"Three Phase\\" Distribution Box, Material Provided by Contractor
54work for Tightening/ Installtion/Fixing of 11 KV \\"F\\" Clamp, Material Provided by Contractor
55work for Installtion/Fixing of LT Clamp T OFF with Bolt & Nuts, Material Provided by Contractor
56work for Tightening/Installtion/Fixing of LT Clamp Pole Clamp for PCC Poles with Bolt & Nuts, Material Provided by Contractor
57work for Installtion/Fixing/Tightening of Danger Board with covering of Barbed wire including Jumper Tightening of Bolt & Nuts, Material Provided by Contractor
58Sundry item ( Required Materials), Provided by Contractor Please Enable Macros to View BoQ information

Other Detail

Information Source https://etender.up.nic.in
Download FileName File Description File Size
Download BOQ_2166134.xls Tender Documents 0 KB
Download c106321a-deab-4f98-9291-796627bb4237.html Tender Documents 0 KB
Download tenderform18.pdf Tender Documents 0 KB
Download Tendernotice_1 (19).pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.