| 1 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete., Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate |
| 2 | FLOOD LIGHT LUMINAIRES Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with dirver set suitable for 170 to 200 Watt. Confirming to IP 66 protection complete in all respect., CAT- AAA |
| 3 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc., 95 sq. mm 3-1/2 core |
| 4 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc., 70 sq. mm 3-1/2 core |
| 5 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc., 25 sq. mm 3-1/2 core |
| 6 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc., 16 sq. mm 4 core |
| 7 | Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge., 95 sq. mm |
| 8 | Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge., 70 sq. mm |
| 9 | Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge., 25 sq. mm |
| 10 | Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge., 16 sq. mm |
| 11 | S&F of 6 Amp to 32 Amp. SPMCB (10 KA) C Curve, CAT A |
| 12 | S&F of 63 Amp. S.P. Isolator, CAT B |
| 13 | S&F of 100 Amp 4 pole MCCB (25 KA) Thermal Magnetic release, CAT A |
| 14 | S/F of 1.5 HP power motor complete with chain or etc. as per direction of E/Ic. PSR river front |
| 15 | Supply and fixing of 4 core multi flexible copper wire PVC insulated complete in all respect PSR |
| 16 | Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect., 40 A TPN |
| 17 | Supply and erection of factory fabricated and wired metal clad dust and vermin proof floor mounting panel TPN switch board complete with the following HRC type heavy duty TPN fuse switches with fuses and instrument chamber etc. complete in all respects. The instrument chamber shall be separate and shall comprise of flush type ammeter, voltmerer, selector switches for ammeter and voltmeter, instrument fuses, current transormer etc. The board shall have suitable capacity electroytic alumininum busbars as per IS8623 istulate with heat shrink sleeving and mountend on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches shall be complete with suitable cable end boxes, reverse entery boxes in case of pedestaal type, cable sockets, compression glands and indicating lamp on incoming etc. The job includes the grounting of the board as per direction of Engineer-in-Charge. All coutgoing switches of 100 Amp. and above will be provided with ampere metre current transformers and selector switches and instrument fuses etc. The switches board shall be fabricated with CRCA sheet with a minimum thickness of 1.6 mm/2 mm. Cubicle type switch board shall be of cat A B & B-II and pedestal type for Cat-B and C only. (Incoming - 200 Amp TPN 1 No.), Outgoing -100 Amp. TNP-2 Nos., Cat. B. Cubicle Type |
| 18 | \\"Supply and burring of Safe Earthing Electrode T-19 Zn-Zinc Coated, Length 3000mm, outer pipe 48.4mm x 3.2mm, inner pipe 26.9mm x 2.6, terminal Dia 12 mm, coating 80-100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30 cm square C.I. frame with hinged cover & masonary housing. (From electrode terminal to switch board, cost of 25 x 3 G.I. Strip will be extra) Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. S.I.No-726 B/18.\\" |
| 19 | Supply and fixing of 2 Meter high cage fabricated with 3MM thick expended metal fixed on 50mm X 50mm X 6mm angle iron frame having vertical members spaced at 1 to 1.25 MT and horizontal member Spaced a Mt .The Vertical members shell be grouted in floor and horizontal members in the wall to depth of 300mm with ends forked. The cage shell have 2000mm X1000mm Size one leaf door with locking device having door frame fabricated with 35mm X 6mm angle iron and 3mm expanded metal duly fixed with the cage members with hinges etc. The shell be painted with red oxide primer and synthetic enamel paints. The Job includes all materials labor T&P etc. For proper |
| 20 | Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as required complete in all respect. |
| 21 | S/F of Steel Rope complete in all respect. As per Direction of E/Ic. |
| 22 | Supply and Fixing Suitable size ring for fixing of Light Fixture. |
| 23 | Supply and Fixing of 4.00 sqmm copper wire PVC insulated complete in all respect. |
| 24 | Supply and fixing of 2.5 sqmm copper wire PVC insulated complete in all respect. |
| 25 | Supply and fixing of 2.5 sqmm 3 core flexible copper wire PVC insulated complete in all respect. |
| 26 | Dismantling and Refixing of 30 mtr High Mast Pole shaft of approved Make with rising system hot dipped galvanised inside & out side dip, having pole sheet thickness 4 mm, top dia minimu 150 mm, bottom dia 500 mm base Plate 32 mm thick, suitable for wind velocity as per IS 875 part 3 having no circuferential weld, with acessories for high mast such as head Fram suitable for 8 to 12 luminaries & it's control gear boxes 1.5 HP motor power tool motor, 3 point suspension system with steel wire rope 8 mm dia, double drum winch, including making suitable foundation as per Manufacturer drawing/ site requirment along with foundation bolts Nut, washers, anchor plates etc all T& P, Hydra, labour etc. complete in all respect. 64 Poles x 2 (dismantling +re- installation)S.No.655 Labour Rate. (16500 + 16500 = 33000.00) |
| 27 | Supply and installation of GI Sheet Junction Box Cover for Protection of Gare Box, Motor, Leaver ect. |
| 28 | Supply and Installation of Geared Box for motor drive |
| 29 | Supply and installation of Head Frame Set |
| 30 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required., 63 mm dia (CD-63 mm & ID-51 mm nominal) |
| 31 | Brick work with common burn clay F.P.S (Non modular) bricks class designation 7.5 in foundation and plinth in Cement mortar1:6 (1 cement : 6 coarse sand) DSR 6.1.2 (2023)-plateform for stablizer-230x1000x700mm |
| 32 | SF of double pole structure with 2 nos ST pole for SS 410 SP-54 11 Mtr long in 136 CC foundation 1/6 of pole length below GI and 30cm above G.1 20cm thick around the pole with 2 nos channel 125mmx75 mm one No Chennel cross arm of 75mmX 40mm 2 No 50X50X6mm single iron bracings with necessary nut bolts & packing pieces complete with painting as per direction of El PSR Bond No 87/CE/EE(E/M) 2021, Dated 09-11-2021. |
| 33 | \\"S/F of 11 KV Pin insulator with G.1. Bolt/spindle nut etc. complete in all respects. PSR Bond No.87/CE/EE(E/M)/ 2021, Dated 09-11-2021 \\" |
| 34 | S/F of 11 KV Disc insulator including gun fitting on cross arm/clamps fixed on pole complete in all respects. PSR Bond No.87/CE/EE(E/M)/ 2021, Dated 09-11-2021 |
| 35 | S/E of over head line with A.C.S.R. conductor on pole/service bracket including binding etc. complete in all respects. S.I.No-627/18. Racoon/Dog |
| 36 | S/F of M.S. Channel 75mmX40mm Vshape crossd arm for two No. pin insulator proper completion of work. PSR Bond No.87/CE/EE(E/M)/ 2021, Dated 09-11-2021 |
| 37 | \\"S/E of 11 K.V L.A. set of 3 wire. suitable for mounting on steel support complete in all respect as per direction of E/I. PSR Bond No.87/CE/EE(E/M)/2021, Dated 09-11-2021 \\" |
| 38 | S\E of 11 KV TPMO switches on poles including handle rod etc. complete in all respects as approved by E\I. |
| 39 | S/E of 11 K.V. D.O. fuse set on pole complete in all respect as per direction of E/1. PSR Bond No.87/CE/EE(E/M)/ 2021, Dated 09 11-2021 |
| 40 | Supply and laying of 70 Sqmm 3 core 11 KV standered aluminium conductor XLPE (Cross linked polyethylene) insulated PVC bedded Galvanised flat steel strip armoured cables confirming to 1.S. 709 (Part-II with latest amendments) II KV grade at a depth of 900 m below ground level over a cushion of 100 mm thick fine river sand a around and protected with well burnt bricks on sides and on top pu across. The armouring of cable shall be properly connected wi earth conductor by clamps etc. PWD SOR No: 506 (d) |
| 41 | S/F of 70 Sq.mm size 3 core XLPE 11 KV outdoor type jointing kit proper completion of work as per direction of E/I A.R. Make: Raycheme, Mahindra. PSR Bond No.02/CE/EE(E/M)/2022, Dated 19.04.2022) |
| 42 | Installation 100/160 KVA 11/0.4 KVA Transformer with all accessory proper completion of work as per direction of E/I (PSR Green Corridor) |
| 43 | \\"Supply and burring of Safe Earthing Electrode T-19 Zn-Zinc Coated, Length 3000mm, outer pipe 48.4mm x 3.2mm, inner pipe 26.9mm x 2.6. terminal Dia 12 mm, coating 80-100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30 cm square C.I. frame with hinged cover & masonary housing. (From electrode terminal to switch board, cost of 25 x 3 G.1. Strip will be extra) Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. S.I.No-726 B/18.\\" |
| 44 | S/L of 25mmx3mm Gl strip from earth electrode directly in the ground as required complete in all respect Item No 716-SOR-2018 |
| 45 | \\"Supply and fixing of 2 metres high cage fabricated with 3mm thick expanded metal fixed on 50mm x 50mm x 6mm angle iron frame having vertical members spaced at 1 to 1.25 mts and horizontal members spaced at 1 mt. The vertical members shall be grouted in floor and horizontal members in the wall to a depth of 300mm with ends forked. The cage shall have 2000mm x 1000mm size one leaf door with locking device having door frame fabricated with 35mm x 35mm x 6mm angle iron and 3mm expanded metal duly fixed with the cage member with hinges etc. The cage shall be painted with red oxide primer and synthetic enamel paint. The job includes all materials, labour, T&P etc. for proper completion of work. PWD SI No: 1142 \\" |
| 46 | \\"S/E of 2.24 mtr. Long cross arm 50mmx 50mm. channel on pole including clamps, eye bolts etc. with red enamel paint as per direction of E/Ich. (Analysed as per SOR- 2020 civil) \\" |
| 47 | \\"S/L of following size G.I. ''B'' class pipe at a depth of 750mm below ground level as cable carrier as direction of E/Inch. (PSR Bond No.02/CE/EE(E/M)/ 2022, Dated 14.09.2022) (a) 80 mm dia\\" |
| 48 | Supply and Fixing of 100 KVA, 300 – 470 / 400 Volts, 3 Phase, Unbalanced Type, Oil Immersed, Indoor / Outdoor Digital Micro Controlled Servo Stabilizer with Built-In Isolation Transformer including First Filling of Fresh Oil and Standard Fittings & Accessories. Note: 1) High Cut Off, Low Cut Off & Over-Load Protections are Included. 2) Single Phasing and Phase Reversal Cut Off is Included. As per Direction of E/Ic. (PSR) |
| 49 | Operation of Part-A 1st Year (2.5 % on Part-A) (11552543x 2.5% |
| 50 | Operation and Maintanance of Part-A 2nd Year (5 % on Part-A) (11552543 x 5%) |
| 51 | Operation and Maintanance of Part-A 3rd Year (7.5 % on Part-A) (11552543 x 7.5%) |
| 52 | Operation and Maintanance of Part-A 3rd Year (10 % on Part-A) (11552543 x 10%) |
| 53 | Operation and Maintanance of Part-A 3rd Year (12.5 % on Part-A) (11552543 x 12.5%) Please Enable Macros to View BoQ information |