Indian Tenders

Tender Notice

TDR 55752603
Tendering Authority Military Engineer Services
Tender No GE (AF) MC/CHD/T-36/2026-27
Tender ID 2026_MES_768768_1
Tender Brief Corrigendum : Tender For Special Repair To Summer Appliances At 3 Brd Under Ge (Af) Mc Chandigarh
City Chandigarh
State Chandigarh
Document Fees INR 500 /-
EMD INR 97100.0 /-
Tender Value INR 48.55 Lakhs /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender For Special Repair To Summer Appliances At 3 Brd Under Ge (Af) Mc Chandigarh

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 10-06-2026 Revised dates Date 22-06-2026
2 10-06-2026 Revised BOQ BOQ 22-06-2026

Key Dates

Publish Date 10-06-2026
Last Date of Bid Submission 22-06-2026
Tender Opening Date 24-06-2026

Contact Information

Company Name Military Engineer Services
Contact Person GE (AF) MC CHANDIGARH
Address GE (AF) MC CHANDIGARH

BOQ Items

Name of Work:- SPECIAL REPAIR TO SUMMER APPLIANCES AT 3 BRD UNDER GE (AF) MC CHANDIGARH
Sl. No. Item Description
1M&L for dismantling existing Split AC of capacity 1.5/2.0 TR by disconnecting electric connections and making good of the removed surface as per existing finish including transporting of Removed/Dismantled ACs with all accessories to the AGE E/M Store Yard complete all as specified and directed.
2Supply and install high wall inverter type indoor unit of split AC of cap 2.0 TR (white color) suitable for hot and cold both outdoor unit made up of copper, filled with latest eco friendly refrigerant R-32 with cordless remote control unit and with in built air filter for better indoor air quality with 3 star rating, auto restart, Blower motar, evoporating coil, swing motar including copper tube and 3 core 2.5 Sqmm copper wire upto 5 metre with suitable size PVC pipe complete all as specified and directed. Make : Daikin/ Panasonic/ Ogeneral/ Mitsubishi.
3Supply and install high wall inverter type outdoor unit of split AC of cap 2.0 TR (white color) suitable for hot and cold both indoor unit made up of copper, filled with latest eco friendly refrigerant R-32 with 3 star rating, auto restart, Compressor, condensing coil, fan motar including copper tube upto 5 metre and 3 core 2.5 Sqmm copper wire upto 5 metre including Floor/Wall stand for outdoor with suitable size PVC pipe having nylon threaded reinforcement for condensed water upto 15 metre complete all as specified and directed.Make-Daikin/Panasonic/Ogeneral/Mitsubishi
4Supply and install high wall inverter type indoor unit of split AC of cap 1.5 TR (white color) suitable for hot and cold both outdoor unit made up of copper, filled with latest eco friendly refrigerant R-32 with cordless remote control unit and with in built air filter for better indoor air quality with 3 star rating, auto restart, Blower motor, evoporating coil, swing motar including copper tube and 3 core 2.5 Sqmm copper wire upto 5 metre with suitable size PVC pipe complete all as specified and directed. Make : Daikin/ Panasonic/ Ogeneral/ Mitsubishi.
5Supply and install high wall inverter type outdoor unit of split AC of cap 1.5 TR (white color) suitable for hot and cold both indoor unit made up of copper, filled with latest eco friendly refrigerant R-32 with 3 star rating, auto restart, Compressor, condensing coil, fan motor including copper tube upto 5 Metre and 3 core 2.5 Sqmm copper wire upto 5 metre including Floor/Wall stand for outdoor with suitable size PVC pipe having nylon threaded reinforcement for condensed water upto 15 metre complete all as specified and directed.Make : Daikin/ Panasonic/ Ogeneral/ Mitsubishi.
6Supply and fix copper tubing superior quality of dia 3/8\\" (min thickness 0.70mm) with insulation and saddles complete all as specified and directed.
7Supply and fix copper tubing superior quality of dia 1/4\\" (min thickness 0.70mm) with insulation and saddles complete all as specified and directed.
8Supply and top up R-32 refrigerant as per existing to desired level for any make and model suitable Split AC 2 TR and 1.5 TR including detection of gas leakage, brazing and welding etc. to the entire satisfaction of Engr-in-Charge.
9Supply install in replacement Water cooler, fully stainless steel body, Cooling capacity 40 Ltrs, Storage capacity 80 Ltrs, Number of faucets 02, Refrigerant R 134A all as specified and directed. Make : Voltas/ Blue Star/ Usha/ Havells.
10S&F in replacement of commercial cooler of size 80 cm x 59 cm x 123 cm fabricated made out of PVC sheet, Air Delivery of 7500 m³/h, tank capacity 100 ltrs, 4 leaf metal exhaust blades 457 mm sweep, copper double ball bearing motor, 3 side honeycomb Pads With bacteria Shield Technology, total weight 24 Kg, power consumption 400 W, dust Filter Nets, electronic knob panel, thermal overlaod protection, Castor wheels, completely collapsible louvers, water level indicators with 3 core cord cable all as specified and directed.
11Supply and fixing ceiling fans complete with aluminium blades, down rods upto 3 feet, suitable for electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 215 CMM with service value 6.00 BEE. Five star rated with brushless direct current copper motor with copper winding (BLDC) complete all as specified and directed by Engr-in-Charge. Note : Taking down old fan and deposit to MES Store yard is the responsiblity of the contractor, no extra cost will be given in this regard. Make : Havells/ Atomberg/ Goldmedal.
12Supply and fixing of MCB protected modular socket with Modular MCB 20 Amps built in MCB+ 20 Amps Top + Socket 20 Amps with sheet metal enclosure, concealed in wall with overmolded inner frame and outer Glass/Mirror finish modular cover for mounting complete including making good (i.e plastering, one coat of putti and two coats of Apex paint with matching existing surface), complete all as specified and directed. Make : Goldmedal (Nixon GIFA Z9)/ Legrand (Arteor)/ Schneider (Zencelo)/ Anchor (Panasonic Thea).
13Supply and fixing of MCB protected modular socket with Modular MCB 16 Amps built in MCB+ 16 Amps Top + Socket 16 Amps with sheet metal enclosure, concealed in wall with overmolded inner frame and outer Glass/Mirror finish modular cover for mounting complete including making good (i.e plastering, one coat of putti and two coats of Apex paint with matching existing surface), complete all as specified and directed. Make : Goldmedal (Nixon GIFA Z9)/ Legrand (Arteor)/ Schneider (Zencelo)/ Anchor (Panasonic Thea).
14Supply and fixing Motar starter switch 16 Amps, 2 Module with red and green colour two switch with sheet metal enclosure, concealed in wall with overmolded inner frame and outer Glass/Mirror finish modular cover for mounting complete including making good (i.e plastering, one coat of putti and two coats of Apex paint with matching existing surface), complete all as specified and directed. Make : Goldmedal (Nixon GIFA Z9)/ Legrand (Arteor)/ Schneider (Zencelo)/ Anchor (Panasonic Thea).
15Supply and fixing Motar starter switch 25 Amps, 2 Module with red and green colour two switch with sheet metal enclosure, concealed in wall with overmolded inner frame and outer Glass/Mirror finish modular cover for mounting complete including making good (i.e plastering, one coat of putti and two coats of Apex paint with matching existing surface), complete all as specified and directed. Make : Goldmedal (Nixon GIFA Z9)/ Legrand (Arteor)/ Schneider (Zencelo)/ Anchor (Panasonic Thea).
16Material and labour for Concealed Sub Main Wiring with two run single core 4 Sqmm (nominal area) multi stranded copper conductor FRLS PVC insulated and unsheathed 1100 volts grade colour code cables, drawn on surface in and including UPVC casing & caping with and including one run of continuous multi stranded copper conductor 4 Sqmm (nominal area) FRLS PVC insulated and unsheathed 1100 volts grade colour code cable for earth continuity and making good disturbed surface including taking down old, complete all as specified and directed.Note:- Two run of 4 Sqmm + One run of 4 Sqmm for earth wire + One run of PVC casing & Caping shall be measured as one RM.
17Dismantling, shifting and reinstallation of existing Split Air Conditioner unit including indoor unit and outdoor unit, complete with safe recovery of refrigerant gas, disconnecting electrical and refrigerant connections, dismantling of existing mounting arrangements, transportation within premises, refixing and commissioning at new location as required. The work shall include providing and fixing of new heavy duty MS powder coated/GI outdoor unit stand with necessary foundation and fixing arrangement, reconnecting insulated copper refrigerant piping, drain piping, control cable, power connections, topping up of refrigerant gas as required, vacuuming, testing for leakage, trial run and commissioning complete for proper functioning of AC unit, complete all as specified and directed by Engineer-in-Charge. Please Enable Macros to View BoQ information

Other Detail

Information Source https://defproc.gov.in/nicgep/app
Download FileName File Description File Size
Download 1189908c-bcfb-4ddc-8ff3-93f1aab38ecb.html Tender Documents 0 KB
Download BOQ_860912.xls Tender Documents 0 KB
Download TenderDocument36.pdf Tender Documents 0 KB
Download Tendernotice_1 (2).pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.