Indian Tenders

Tender Notice

TDR 55750244
Tendering Authority Department Of Agriculture
Tender No ADFW/EXE/ALP/53/2026-EE2
Tender ID 2026_AGRI_853337_1
Tender Brief Tender For Supply, Erection, Testing And Commissioning Of Vertical Axial Flow Pump Set (Non-Submersible) For Various Padashekarams Under Cherthala Legislative Assembly Constituency Of Alappuzha District Of Kerala With The Specifications Given Below.
City Cherthala
State Kerala
Document Fees INR 12000 /-
EMD INR 60000.0 /-
Tender Value INR 60 Lakhs /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Supply, Erection, Testing And Commissioning Of Vertical Axial Flow Pump Set (Non-Submersible) For Various Padashekarams Under Cherthala Legislative Assembly Constituency Of Alappuzha District Of Kerala With The Specifications Given Below. , Suitable For Handling Saline And Silty Water With Rpm 960 (Sync) Or Less. The Material Of Construction Of Flange, Suction Bell, Bowl, Shroud Shall Be Ci With 2% Nickel. Impeller, Shaft, Shaft Sleeve, Fastener Shall Be Of Ss 304. Suction Pipe And Delivery Pipe Should Be In Ss 304 With Minimum Thickness 6 Mmand Of Suitable Length (Varies From 4-10M) Or As Per Site Condition. The Prime Mover Of The Pump Is To Be 3 Phase Tefc Squirrel Cage Induction Motor Of Reputed Make Having Star Rating Above4 Operating At 415V +/- 10%, 50 Hz +/- 5% Connection With F Class Insulation, Control Panel Must Have Dust And Vermin Proof Vertical Mounted Cubical Type Panel Board Of Reputed Make With Fcma Soft Starterofreputed Make, Mccb Including Phase Failure Protection, Surge Protection Device, Dry Run Protection, Overload Over Current Protection, Thermal Overload Protection Relay, Earth Fault Relay, Voltmeter-Ammeter Fault Indication, Start And Stop Switches And Power Factor Correction Capacitor Etc. Wiring And Earthing Should Be As Per Regulations Of Kseb And Electrical Inspectorate. Separate Cubical Type Energy Meter Panel With Ct Metering Provision Including 4 Pole Fn Type Isolator, Rccb , Hrc Fuses And Carrier. Suitable Size Copper Cable For Connection From Electric Post To Meter Box And Meter Panel To Motor Control Panel Etc. Should Be Fitted At Site, With Proper Earthing. Cable Termination Should Be As Per The Regulations And Specifications Of Kseb And Electrical Inspectorate Standards. Screen With 6Mm Gi Welded Mesh With 50 Mm X 50 Mm Opening Size (About 20 Sq.M Area) Framed In Gi Angles And Gi Tubes Fitted At The Opening On Top And Sides Of Sump To Prevent Entry Of Unwanted Materials To The Pump Through Inflow Water. Proper I-Section Should Be Provided For Supporting The Motor Mountings And Pedestal. Suitable Chain Block And Tripod Facilities To Be Provided For Lifting The Motor At Least 1.00 M Above Maximum Flood Level. Rate Quoted Should Be Inclusive Of All The Charges For Supply, Installation Including Trial Run And Commissioning, All Types Of Transportation And Conveyance, Loading And Unloading Charges, Charges For Factory Testing, But Excluding Gst Etc. , Duty Point Head (M): 2.5 Minimum Discharge At Duty Point Head (Lps): 912 Minimum Overall Efficiency At Duty Point (%) : 60 Available Connected Load: 50 Hp

Key Dates

Publish Date 01-06-2026
Last Date of Bid Submission 01-07-2026
Tender Opening Date 02-07-2026

Contact Information

Company Name Department Of Agriculture
Contact Person EE Agri Alappuzha
Address O/o EE Agri Alappuzha

BOQ Items

Name of Work:- Supply, erection, testing and commissioning of Vertical Axial Flow pump set (Non-Submersible) for various padashekarams under Cherthala Legislative Assembly Constituency of Alappuzha district of Kerala with the specifications given below.
Sl. No. Item Description
1Suitable for handling saline and silty water with rpm 960 (Sync) or less. The material of construction of flange, suction bell, bowl, shroud shall be CI with 2% Nickel. Impeller, Shaft, shaft sleeve, fastener shall be of SS 304. Suction pipe and Delivery pipe should be in SS 304 with minimum thickness 6 mmand of suitable length (varies from 4-10m) or as per site condition. The prime mover of the pump is to be 3 phase TEFC squirrel cage induction motor of reputed make having star rating above4 operating at 415V +/- 10%, 50 Hz +/- 5% connection with F class insulation, control panel must have dust and vermin proof vertical mounted cubical type panel board of reputed make with FCMA soft starterofreputed make, MCCB including phase failure protection, surge protection device, dry run protection, overload over current protection, thermal overload protection relay, earth fault relay, voltmeter-ammeter fault indication, start and stop switches and power factor correction capacitor etc. Wiring and earthing should be as per regulations of KSEB and electrical inspectorate.Separate cubical type energy meter panel with CT metering provision including 4 Pole FN type isolator, RCCB , HRC fuses and carrier. Suitable size Copper cable for connection from electric post to meter box and meter panel to motor control panel etc. should be fitted at site, with proper earthing. Cable termination should be as per the regulations and specifications of KSEB and Electrical Inspectorate standards.Screen with 6mm GI welded mesh with 50 mm x 50 mm opening size (about 20 sq.m area) framed in GI angles and GI tubes fitted at the opening on top and sides of sump to prevent entry of unwanted materials to the pump through inflow water. Proper I-section should be provided for supporting the motor mountings and pedestal. Suitable chain block and tripod facilities to be provided for lifting the motor at least 1.00 m above maximum flood level.Rate quoted should be inclusive of all the charges for supply, installation including trial run and commissioning, all types of transportation and conveyance, loading and unloading charges, charges for factory testing, but excluding GST etc.
2Duty Point Head (m): 2.5Minimum discharge at Duty Point Head (lps): 912Minimum overall efficiency at duty point (%) : 60Available Connected Load: 50 Hp Please Enable Macros to View BoQ information

Other Detail

Information Source https://etenders.kerala.gov.in
Download FileName File Description File Size
Download 06a6699e-74e3-48fe-872f-c5c863a778ca.html Tender Documents 0 KB
Download ann1.pdf Tender Documents 0 KB
Download ann2.pdf Tender Documents 0 KB
Download BOQ_1442111.xls Tender Documents 0 KB
Download KFC14.pdf Tender Documents 0 KB
Download Tendernotice_1 (10).pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.