Indian Tenders

Tender Notice

TDR 55748595
Tendering Authority Public Works Department
Tender No 1313/11CBW-17E/M/2026-27 Dated- 26-05-2026
Tender ID 2026_CEEMP_1155721_1
Tender Brief Tender For Electrification Work For The New Construction Work Of District Magistrate Sitapurs Residence.
City Sitapur
State Uttar Pradesh
Document Fees INR 854 /-
EMD INR 174000.0 /-
Tender Value Refer document
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Electrification Work For The New Construction Work Of District Magistrate Sitapurs Residence.

Key Dates

Publish Date 30-05-2026
Last Date of Bid Submission 15-06-2026
Tender Opening Date 15-06-2026

Contact Information

Company Name Public Works Department
Contact Person SE 17th Circle PWD lucknow
Address SE 17th Circle PWD lucknow

BOQ Items

Name of Work:- जिलाधिकारी सीतापुर के आवास के नवीन निर्माण कार्य हेतु विद्युतीकरण का कार्यA
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.. Group C DSR No.-1.10.3
2Wiring for twin control light point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVCconduit, 2way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor singlecore cable etc. as required. DSR No.-1.11
3Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, as required.
42 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire DSR No.-1.14.1
52 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire DSR No.-1.14.2
62 X 4 sq. mm + 1 X 4 sq. mm earth wire DSR No.-1.14.3
72 X 6 sq. mm + 1 X 4 sq. mm earth wire DSR No.-1.14.4
82 X 10 sq. mm + 1 X 6 sq. mm earth wire DSR No.-1.14.5
9Supplying and drawing of 3x1.5 sq. mm size of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel / PVC conduit as required. DSR No.-1.17.3
10Supplying and drawing of 1x 1.5 sq mm size of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required DSR No.-1.17.1
11Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch , connections etc. as required. DSR No.-1.31
12Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch , connections etc. as required. DSR No.-1.32
13Supply, Installation, Testing amd Commissioning of LT Panel vermin proof floor mounting , M.S. channel base with bottom and Fabricated out of 2.0/1.6mm thick CRCA sheet steel, painted with powder coated paint of shade as per the direction of Engineer In-Charge after proper sheet treatment process of sheet steel. The Bus Bar of panel shall be of Electrical grade High Conductive Aluminum alloy of appropriate cross section as per rating.The main bus bar shall run throughout the panel of rating as main incomer rating. The Bus Bar shall be supported by non hygroscopic SMC/DMC Bus Bar supports which shall be mounted on proper interval to ensure the bear the jerks of short Circuit of 50kA for panels having ACB as Incomer & 36kA for panels having MCCB Incomers. Panel shall be constructed in fully Segregated Compartment Design for Each Feeder as per 3b construction Format. The Panel shall be completed in all respect as per IS: 8623 Part-2&3. There shall be Separate Metering Compartment for incomer metering and outgoing metering.All Incomer Feeders shall be provided with Multifunction Metering along with Phase Indicating Lights and other associated components such as CT, control MCB Terminal Block etc. and all Outgoing Feeders 100A & above shall be provided with 3 phase Ammeter along with phase Indicating Lights and other associated components such as CT, control MCB Terminal Block etc. The Feeders above shall be provided ac accommodated all Measuring Instruments shall be Digital type & all Indicating Lights shall be LED type.Wiring shall be done from 1100V Grade PVC Insulated copper flexible wire. All ACB shall be Electrically operated Draw-out type with Microprocessor Based O/L, S/C & E/F Release of Breaking/ Withstand Capacity (ICU/ICs/Icw) 50kA or more All MCCB shall be Thermal Magneetic/Microprocessor with O/L & S/C Protection along with Required Spreaders & Extended Rotary Handle with pad Locking facility of Breaking capacity (ICU/ICS) 36kA or more All MCB shall be Thermal 10kA 'C' Curve. Cubicle type switch board shall be Cat-A and B only.Incoming - 250Amp.MCCB-1 NoOutgoing - 63 Amp. MCCB-03 Nos. & 100 Amp MCCB- 01 No. Code no.-22.1
14Supplying and fixing of 4 ways (4+12), Double door TPN MCBDB horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections,powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) DSR No.-2.4.1
15Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\"curve DP MCB complete with connections, testing and commissioning etc. as required. DSR No.-2.16
16Supplying and fixing following way Double door SPN MCBDB single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections,powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
17For 12 way, Double door DSR No.-2.3.3
18Supplying and fixing 40 A rating, two pole MCB (10 KA) C- Series Havells or Eq. Quot.
19Supplying and fixing 63 A rating, Four pole MCB (10 KA) C- Series Havells or Eq. Quot.
20Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of Single poles in the exixting MCB DB complete with connections, testing and commissioning etc. as required. DSR No.-2.10.1
21Supplying and fixing 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of Triple pole in the exixting MCB DB complete with connections, testing and commissioning etc. as required. DSR No.-2.10.4
22Supplying and fixing 40 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of Single poles in the exixting MCB DB complete with connections, testing and commissioning etc. as required. A/R
23Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/coke and salt as required. DSR No.-5.4
24Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring,washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) DSR No.-5.9
25S/F Exhaust/ Fresh air Fan 300mm sweep metallic Quot.
26Supply and Fixing of Hexagonal / Round G.P fan box of Approved make Quot.
27Supply, Installation, Testing and Commissioning of Brush Less Direct Current (BLDC) ceiling fan with Remote with Brush Less Direct Current (BLDC)Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) DSR No.-9.1.3
28Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. DSR No.-1.38
29\\"LED Down lighter (SMD Type) (System lumenefficacy ≥ 105 < 120 lm/Watt )Supplying, Installation, Testing & Commissioning of 18 watt LED Recessed/ surface Down lighter (Round/square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per therequirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -50C to 400C, internal surgeprotection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flickershould be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc.as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be asapproved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminiumBody including trim\\" DSR No.-8.1.4
30Supply and fixing of surface mounting LED Mirror Light ultra slim economical LED battens in extruded PC housing and square shaped diffuser with 10 W. HSN code- 9405 of Havells or Eq. A/R
31Supply and fixing of Wall Bracket light, brushed nickel finish fixture with opal glass diffuser suitable with 9 W LED lamp B22 base, HSN code-94051900 of Havells or Eq. A/R
32Supply and fixing of water tight oblong 10watt LED Bulkhead lumaniare having pressure die cast housing with driver set confirming to IP65 and above protection, IK 08, Hight purity/ transmisivity UV Stabilized Non yellowish diffuser / for uniform light distribution, detachable driver set, open and short circuit protection suitable for 24 hr continuous operation Complete in all respect CAT-AA 1100system lumens,>110Lm/W,PF>0.95,CRI>70 with 3 Year warrantee. CAT-AA Code No.-23.11
33LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of 45 Watt Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). DSR No.-8.12.11
34LED Street light Metal pipe of diameter 32 mm with complete aspect of fitting. Quot.
35Supply and fixing of decorative 40 Watt to 45 Watt, LED Post top indirect light luminaire having Pressure die cast aluminium body and UV Stabilized PC Clear/ frosted glass cover, with driver set confirming to IP 66 and IK 08 protection, Potted driver (Not circuitory) complete in all respect. 4800-5400 system lumens, >120 Lm/W, PF>0.95, THD<10% at full load, CRI >70, >300V Over Voltage Protection and auto restart feature, 4 KV internal Surge Protection, with 5 years warrantee CAT-AAA Code No.-23.21
36LED Batten light 18-22 Watt (System lumen efficacy ≥105 <120 lm/Watt).Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P.F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hourswith 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K(As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating andFixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductorsingle core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LEDfixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) DSR No.-8.9.1
37Supply and fixing of 9Watt LED Bulb of Havells or Eq. A/R
38S/O of LED Bulb 15W/17W Quot.
39Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade on wall surface as directed by the Engineer-Incharge, complete in all respect. including excavation & refilling. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.
40S/O of 25 sqmm 3-1/2 core armoured cable. Code No. 20c.1.10
41Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand all around and protected with burnt bricks on sides and on top as directed by engineer - incharge complete in all respect.including excavation & refilling. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.
42S/O of 185sqmm 3-1/2 core armoured cable. Code No. 20a.1.17
43Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheated/XLPE aluminium conductor cable of 1.1 KV grade as required
4425 sq. mm 3-1/2 core DSR No.-11.1.9
45185 sq. mm 3-1/2 core DSR No.-11.1.16
46S/O Four Pole onload Changeover Switch 250Amp with SS enclosure code No- IHCNFE0250 of Havells or Eq A/R
47Supplying, Installation, Testing & Commissioning of Modular type Variable Refrigerant Flow/VariableRefrigerant Volume air cooled Outdoor units suitable for cooling/heating having 100% hermetically sealed inverter type twin Rotary/Scroll Compressor(s), minimum two compressors (with individual separate PCB) for above 14HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R-410-A Refrigerant or equivalent, vibration Isolators with suitable foundation etc. complete as required. To have better efficiency condenser fan shall be capable to operate at different speed with respect to load. The unit shall deliver the rated capacity and in confirmation as per IS 18728:2024 and CPWD Specifications and work even at 50°C ambient temperature without tripping. The system shall be able to deliver 100% of the rated capacity upto 390C. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply and BMS compatible. The unit shall be filled with first charge of the refrigerant and ready for use as required. The condenser should be coatedwith a hydrophilic film to prevent water accumulation on the surface of the heat exchanger, enhance water dispersion, and reduce the risk of degradation, thereby improving overall performance and durability. The Indian Seasonal Energy Efficiency Ratio (ISEER) of the unit shall be as per Energy Conservation and Sustainable Building Code (ECSBC) 2024 as below and complete as per CPWDspecification, connections, inter connections etc. as required. (For capacity <40 kWr ISEER 5.4, Capacity > 40 and <70 ISEER 5.5, Capacity > 70 ISEER 5.6 for ECSBC Building) For Cooling or Heating or Both
486 HP DSR No.-31.1.1
49Supplying, Installation, Testing and Commissioning of following minimum capacity 4 way Cassette Type Indoor ceiling mounted unit equipped with synthetic washablemedia pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration Isolation, Corded remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The Indoor units must shut down upon receivinga singal from the BMS System/Fire Singnals. The system shall be capable to adjust air flow as per room requirement in auto mode. The cooling capacity of indoor unit will be at air inlet conditions of 27 0C DB and 19 0C WB temperature. (Make will be same as of Outdoor)
501.2 TR DSR No.-31.4.3
51Supplying, Installation, Testing and Commissioning of following minimum capacity Single way wall/corner VRV/VRF Cassette Type Indoor ceiling mounted unitequipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration Isolation, Corded remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The Indoorunits must shut down upon receiving a singal from the BMS System/Fire Singnals. The system shall be capable to adjust air flow as per room requirement automatically. The cooling capacity of indoor unit will be at air inlet conditionsof 27 0C DB and 19 0C WB temperature. (Make will be same as of Outdoor)
521.6 TR DSR No.-31.6.5
53Supplying, Installation, Testing and Commissioning of Y/T/Multi Joints. Joints shall be of same Original Equipment Manufacturer (OEM) make as of ODUs and IDUs
54Indoor Units DSR No.-31.13.1
55Outdoor Multi Joint DSR No.-31.13.2
56Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required :
576.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm DSR No.-31.14.1
589.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm DSR No.-31.14.2
5912.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm DSR No.-31.14.3
6015.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 DSR No.-31.14.4mm
61Providing and fixing rigid PVC piping Complete with fittings, supports as per specifications and duly insulated with 6 mm thick closed cell nitrile rubber insulated.
6232 mm dia Quot.
6325 mm dia Quot.
64Supplying and fixing of fire extinguisher ABC Type 9.0 kg. capacity ( ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all material and labour for proper complete of work. Quot.
65Supplying and fixing of fire extinguisher CO2 Type 6.5 kg. capacity ( ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all material and labour for proper complete of work. Quot.
66Supplying and Laying of 1800mm x 900mm x 12mm thick chequered Rubber matting of Tested Quality Quot. Please Enable Macros to View BoQ information

Other Detail

Information Source https://etender.up.nic.in
Download FileName File Description File Size
Download BOQ_2165137.xls Tender Documents 0 KB
Download f6233d25-a5a5-4a93-8d18-aa1e39bbdc95.html Tender Documents 0 KB
Download T1.pdf Tender Documents 0 KB
Download Tendernotice_1 (19).pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.