| 1 | Excavation in trenches, not exceeding 1.5mtr wide & not exceeding 1.5mtr in depth; for foundation, laying/taking out pipes/cables etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10sqm on plan & not exceeding 1.5mtr in depth and getting out, in soft / loose type of soil complete all as specified & directed. |
| 2 | Excavation in trenches, not exceeding 1.5mtr wide and exceeding 1.5 mtr but not exceeding 3.0 mtr in depth; for foundation, laying/taking out pipes/cables etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10sqm on plan and exceeding 1.5 mtr but not exceeding 3.0 mtr in depth and getting out, in soft / loose type of soil complete all as specified & directed. |
| 3 | Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cm thick each in soft / loose type of soil complete all as specified & directed. |
| 4 | Removal of excavated surplus soil to a distance not exceeding 50 mtr & depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified & directed. |
| 5 | M&L double wall corrugated (DWC) HDPE pipe, outer dia 125mm, having corrugations on the outer surface and plain at inner surface, confirming to IS 14930(Part I & II) with end cap as in trenches/under road/under floor including cutting road/floor and making good wherever necessary or fixed to wall/pole with fixing arrangement for cable protection complete all as specified & directed. Note: Excavation & Earth work shall be measured & paid seperately. |
| 6 | M&L earthing complete with copper earth plate electrode 60 cm X 60 cm, 3.15mm thick buried vertically in ground to depth not less than 3.75 mtr below ground level, with top edge of earth plate not less than 2.5 mtr below ground level, connected to copper earth lead strip 20mm x 3mm upto 7.5 mtr long by means of bolts, nuts, check nuts and washers of copper and connection to earthing test point & earth dolly including watering pipe GI 20mm bore light grade 2.5 mtr long & protection pipe GI light grade 50mm bore upto 7.5 mtr long, wire mesh, funnel,lugs, salt, charcoal dust, excavation & earthwork in any type of soil and refilling, pit chamber with PCC 1:2:4 type B-1 (using 20 mm graded mechnically crushed stone aggregates) , Precast RCC 1:2:4 type B-1 (using 20 mm graded mechnically crushed stone aggregates) pit cover slab 50 mm thick reinforced with 8 mm dia TMT bars @ 15 cm c/c both ways including necessary form work, all as shown in electrical plate No 3 of MES SSR Part-I, including testing on completion at site including dismantling/taking out/down of old existing earthing any type complete all as specified & directed. Notes:- (i) On testing if the desired earth resistance is not obtained, earthing will be generated at No extra cost, till the desired earth resistance is obtained.(ii) The chamber shall be constructed at least 1.5 mtr away from the earth electrode. |
| 7 | M&L plain cement concrete (PCC) 1:4:8, type D-2, using 40mm graded mechanically crushed stone aggregates as in foundations, filling and mass concrete etc. complete all as specified & directed. |
| 8 | M&L plain cement concrete (PCC) 1:3:6, type C-2, using 40mm graded mechanically crushed stone aggregates as in coping to pole etc. including necessary formwork to exposed surface finished even & smooth complete all as specified & directed. |
| 9 | M&L plain cement concrete (PCC) 1:2:4, type B-1, using 20mm graded mechanically crushed stone aggregates as in coping to pole etc. including necessary formwork to exposed surface finished even & smooth complete all as specified & directed. |
| 10 | Taking out / down existing (serviceable / unserviceable) 11KV HT UG cable from trenches/duct/ HT poles, nominal cross sectional area from 95 sqmm to 150 Sqmm including disconnecting of cable and taking out cable covers/bricks) of any description complete all as specified & directed. Notes: (i) Excavation & Earth work shall be measured & paid separately.(ii) Serviceable cable covers/bricks will be kept aside for re-use and the unserviceable one shall be credited to contractor. |
| 11 | Supply, laying, jointing, testing & commissioning heavy duty, HT 11 KV (E), XLPE insulated cable with aluminium conductor, screened with extruded semi conducting layer, insulation screening with copper tape cover laid up with PVC (ST-2) extruded inner sheathed GI strip armoured PVC (ST-2) out sheathed, ISI marked confirming to IS-7098 (Part-II), Size cross sectional area 95 Sqmm & 3 core laid as in trenches/pipes/ducts or fixed along poles/wall/equipment etc. complete all as specified & directed. |
| 12 | S&F in repair Cable jointing kit for 11 KV (Earthed) grade HT cable for straight through heat shrink type joint complete with jointing material & accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 Sqmm complete all as specified & directed.Make: 3M / Denson / Raychem |
| 13 | S&F in repair Cable jointing kit for 11 KV (Earthed) grade HT cable for outdoor termination heat shrink type joint complete with jointing material & accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 Sqmm complete all as specified & directed.Make: 3M / Denson / Raychem |
| 14 | S&F in repair Cable jointing kit for 11 KV (Earthed) grade HT cable for indoor termination heat shrink type joint complete with jointing material & accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 Sqmm complete all as specified & directed.Make: 3M / Denson / Raychem |
| 15 | S&F cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed duly painted with two coats of aluminium paint over & including one coat of zinc oxide primer including dismantling of old unserviceable cross arms as existing complete all as specified & directed. |
| 16 | Disconnecting electric connections of underground HT cable,11 KV, any size/type, from both sides and locating/detecting of pin point fault in cable with fault locating machine comprising impulse generator, acoustic fault locator & reflectometer (Laptop based) in the entire length(upto 500 mtr) with modern fault detector equipment by expert Engineers including reconnecting & commissioning the cable to make it functional complete all as specified & directed.Notes: (i) The work will be executed after obtaining proper shutdown from main power house after liasoning with Engineer-in-charge.(ii) Excavation & Earthwork shall be measured & paid seperately. |
| 17 | Disconnecting electric connections of underground LT cable, any size/type, from both sides and locating/detecting of pin point fault in cable with fault locating machine comprising impulse generator, acoustic fault locator & reflectometer (Laptop based) in the entire length(upto 500 mtr) with modern fault detector equipment by expert Engineers including reconnecting & commissioning the cable to make it functional complete all as specified & directed.Note: Excavation and Earthwork shall be measured & paid seperately. Please Enable Macros to View BoQ information |
| 18 | Disconnecting electric connections of underground LT cable, any size/type, from both sides and locating/detecting of pin point fault in cable with fault locating machine comprising impulse generator, acoustic fault locator & reflectometer (Laptop based) in the entire length(upto 500 mtr) with modern fault detector equipment by expert Engineers including reconnecting & commissioning the cable to make it functional complete all as specified & directed.Note: Excavation and Earthwork shall be measured & paid seperately. Please Enable Macros to View BoQ information |