Indian Tenders

TDR 55705057
Tendering Authority Airports Authority Of India
Tender No GEM/2026/B/7593089
Tender ID GEM/2026/B/7593089
Tender Brief Corrigendum : Bids Are invited for Provision Of Automatic Fire D Ers
City Coimbatore
State Tamil Nadu
Document Fees Ref. Document
EMD INR 71071.0 /-
Tender Value 23.69 Lakh
Tender Type Tender
Bidding Type Open Tender
Tender Category Goods
Competition Type Indian
Exemption No
quantity 4323
Tender Details

Bids Are invited for Provision Of Automatic Fire D Ers Sitc Of Fire D Ers - Supplying, Fixing,Testing And Commissioning Of Fire D Ers In Supply Air Duct Or Main Branch And Return Air Path As And Where Required Of Required Sizes Including Control Wiring,The D Er Shall Be Motorized And Spring Return So As To Close The D Er In The Event Of Power Failure Automatically And Open The Same In Case Of Power Being Restored. The Spring Return Action Shall Be Inbuilt Mechanism And Not Externally Mounted. The D Er Shall Also Be Closed In The Event Of Fire Signal Complete As Required And As Per Specifications. Fire D Er , Sitc Of Fire D Ers In Supply Air Duct Actuator Torque 9Nm, 230V. - Supplying, Fixing,Testing And Commissioning Of Fire D Ers In Supply Air Duct Or Main Branch And Return Air Path As And Where Required Of Required Sizes Including Control Wiring,The D Er Shall Be Motorized And Spring Return So As To Close The D Er In The Event Of Power Failure Automatically And Open The Same In Case Of Power Being Restored. The Spring Return Action Shall Be Inbuilt Mechanism And Not Externally Mounted. The D Er Shall Also Be Closed In The Event Of Fire Signal Complete As Required And As Per Specifications. Actuator Torque 9Nm, 230V. , Sitc Of Fire D Ers In Supply Air Duct Actuator Torque 20Nm, 230V. - Supplying, Fixing,Testing And Commissioning Of Fire D Ers In Supply Air Duct Or Main Branch And Return Air Path As And Where Required Of Required Sizes Including Control Wiring,The D Er Shall Be Motorized And Spring Return So As To Close The D Er In The Event Of Power Failure Automatically And Open The Same In Case Of Power Being Restored. The Spring Return Action Shall Be Inbuilt Mechanism And Not Externally Mounted. The D Er Shall Also Be Closed In The Event Of Fire Signal Complete As Required And As Per Specifications. Actuator Torque 20Nm, 230V. , Supply, Installation, Balancing And Commissioning Of Fabricated At Site Gss Sheet Metal Rectangular Ducting 0.8 Mm Thick - Supply, Installation, Balancing And Commissioning Of Fabricated At Site Gss Sheet Metal Rectangular Or Round Ducting Complete With Neoprene Rubber Gaskets, Elbows, Splitter D Ers, Vanes, Hangers, Supports Etc. As Per Approved Drawings And Specifications Of Following Sheet Thickness Complete As Required. Site Fabricated Gss Sheet Metal Rectangular Ducting As Per Is 655 2006 0.8 Mm Thick , Supply, Installation, Balancing And Commissioning Of Fabricated At Site Gss Sheet Metal Rectangular Ducting 1.00 Mm Thick - Supply, Installation, Balancing And Commissioning Of Fabricated At Site Gss Sheet Metal Rectangular Or Round Ducting Complete With Neoprene Rubber Gaskets, Elbows, Splitter D Ers, Vanes, Hangers, Supports Etc. As Per Approved Drawings And Specifications Of Following Sheet Thickness Complete As Required. Site Fabricated Gss Sheet Metal Rectangular Ducting As Per Is 655 2006 1.00 Mm Thick , Supply And Fixing Of Acoustic Lining - Supply And Fixing Of Acoustic Lining Of Supply Air Duct And Plenum With 25 Mm Thick Resin Bonded Glass Wool Having Density Of 32 Kg Or Meter Cube, With 25 Mm X 25 Mm Gi Section Of 1.25 Mm Thick, At 600 Mm Centre To Centre Covered With Reinforced Plastic Tissue Paper And 0.5 Mm Thick Perforated Aluminum Sheet Fixed To Inside Surface Of Ducts With Cadmium Plated Nuts, Bolts, Stick Pins, Cprx Compound Etc. , Supplying And Fixing Nitrile Rubber Insulation 19 Mm - Supplying And Fixing Of Following Thickness Duly Laminated Aluminum Foil Of Mat Finish Closed Cell Nitrile Rubber Class O Insulation On Existing Duct After Applying Suitable Adhesive For Nitrile Rubber. The Joints Shall Be Sealed With 50 Mm Wide And 3 Mm Thick Self Adhesive Nitrile Rubber Tape Insulation Complete As Per Specifications And As Required. Nitrile Rubber Insulation 19 Mm , Dismantling Of Old Airconditioning Ducts - Dismantling Of Old Airconditioning Ducts From The Ac System Including Removal Of Insulations, Supports Etc. Complete To Make Provision For Connection Of Fire D Er And Shifting The Same To Dismantled Stores Of Aai. , Sitc Of Control Panel For 230V Actuator. - Supply, Instalation, Testing And Commissiong Of Control Panel For 230V Actuator. , Sitc Of Ahu Tripping Panel - Supply, Installation, Testing And Commissiong Of Ahu Tripping Panel In Sheet Steel Enclosure Consists Of Intelligent Addressable Input Or Output Loop Powered Relay Module, Volt Free Contacts Suitable For Functioning Via Fire Alarm Loop. , Supply Of 2X1.5 Sqmm Copper Control Cables - Supply Of 2X1.5 Sqmm Copper Control Cables, Xlpe Insulated, Pvc Innersheathed, Armoured, Extruded Pvc Type St2 Sheathed, 650 V Or 1100 V Grade As Per Is 7098 Part 1 1988. , Laying And Fixing Cable Tray - Laying And Fixing Of One Number Pvc Insulated And Pvc Sheathed Or Xlpe Power Cable Of 1.1 Kv Grade Of Following Size On Cable Tray As Required. Upto 35 Sq.Mm. , Laying And Fixing Of Xlpe Power Cable Of 1.1 Kv On Wall Surface Upto 35 Sq. Mm - Laying And Fixing Of One Pvc Insulated And Pvc Sheathed Or Xlpe Power Cable Of 1.1 Kv Grade Of Following Size On Wall Surface As Required. Upto 35 Sq. Mm Cl Ed With 1Mm Thick Saddle. , Supplying And Making End Termination - Supplying And Making End Termination With Brass Compression Gland And Copper Lugs For Following Size Of Pvc Insulated And Pvc Sheathed Or Xlpe Copper Conductor Cable 1.1 Kv Grade As Required. , Integration Of All Devices For Activiation Of Ahu - Integration Of All Devices For Activiation Of Ahu Tripping In The Event Of Fire Detection, Interfacing With The Existing Fire Dedection System Including Installation Or Modification Or Upgradation Of Program Of All Fire Alarm Panels In The System, Testing And Commissioning Of The System Complete As Required And As Per The Direction Of The Enginner In Charge. The Scope Of Work Also Includes Dismantling Of Unwanted Bms Devices From The System Wherever Required. Total Quantity : 4323

Corrigendum Details
Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate Documents
1 24-06-2026 01-07-2026
2 17-06-2026 24-06-2026
Key Dates
Publish Date 24-06-2026
Last Date of Bid Submission 01-07-2026
Tender Opening Date 01-07-2026
Contact Information
Company Name Airports Authority Of India
Address 641014,33ACA6412D1ZF, Airports Authority Of India, Coimbatore International Airport, Coimbatore
Pincode 641014
Other Detail
Information Source https://gem.gov.in/
BOQ Items
Sl. No. Item TitleItem Description
1SITC of fire dampersSupplying, Fixing,testing and commissioning of fire dampers in supply air duct or main branch and return air path as and where required of required sizes including control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications. Fire Damper
2SITC of fire dampers in supply air duct Actuator torque 9Nm, 230V.Supplying, Fixing,testing and commissioning of fire dampers in supply air duct or main branch and return air path as and where required of required sizes including control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications. Actuator torque 9Nm, 230V.
3SITC of fire dampers in supply air duct Actuator torque 20Nm, 230V.Supplying, Fixing,testing and commissioning of fire dampers in supply air duct or main branch and return air path as and where required of required sizes including control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications. Actuator torque 20Nm, 230V.
4Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular ducting 0.8 mm thickSupply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular or round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Site fabricated GSS sheet metal rectangular ducting as per IS 655 2006 0.8 mm thick
5Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular ducting 1.00 mm thickSupply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular or round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Site fabricated GSS sheet metal rectangular ducting as per IS 655 2006 1.00 mm thick
6Supply and fixing of acoustic liningSupply and fixing of acoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 kg or meter cube, with 25 mm X 25 mm GI section of 1.25 mm thick, at 600 mm centre to centre covered with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminum sheet fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound etc.
7Supplying and fixing Nitrile rubber Insulation 19 mmSupplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber Class O insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. Nitrile rubber Insulation 19 mm
8Dismantling of old Airconditioning DuctsDismantling of old Airconditioning Ducts from the AC system including removal of insulations, supports etc. complete to make Provision for connection of Fire Damper and shifting the same to dismantled stores of AAI.
9SITC of control panel for 230V Actuator.Supply, Instalation, Testing and Commissiong of control panel for 230V Actuator.
10SITC of AHU Tripping PanelSupply, Installation, Testing and Commissiong of AHU Tripping Panel in Sheet Steel enclosure consists of intelligent addressable input or output loop powered relay module, volt free contacts suitable for functioning via fire alarm loop.
11Supply of 2x1.5 sqmm Copper Control CablesSupply of 2x1.5 sqmm Copper Control Cables, XLPE Insulated, PVC Innersheathed, Armoured, Extruded PVC Type ST2 Sheathed, 650 V or 1100 V Grade as per IS 7098 Part 1 1988.
12Laying and fixing cable trayLaying and fixing of one number PVC insulated and PVC sheathed or XLPE power cable of 1.1 KV grade of following size on cable tray as required. upto 35 Sq.mm.
13Laying and fixing of XLPE power cable of 1.1 KV on wall surface Upto 35 sq. mmLaying and fixing of one PVC insulated and PVC sheathed or XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm clamped with 1mm thick saddle.
14Supplying and making end terminationSupplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed or XLPE copper conductor cable 1.1 KV grade as required.
15Integration of all devices for activiation of AHUIntegration of all devices for activiation of AHU tripping in the event of fire detection, interfacing with the existing fire dedection system including installation or modification or upgradation of program of all fire alarm panels in the system, Testing and commissioning of the system complete as required and as per the direction of the enginner in charge. The scope of work also includes dismantling of unwanted BMS devices from the system wherever required.
View Original Notice/Document
Download FileName File Description
Download b465dd9c-fcd0-45b1-a3da-bd369025cc4e.pdf Tender Documents
Download 07_2026-05-27-15-17-48_b1a94befdb41eb68b30420b39bd4125a.pdf Tender Documents
Download 1779876546.xlsx Tender Documents
Download 9388457_Boq_1.xlsx Tender Documents
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Click tab to load Similar Tender Results...