Indian Tenders

Tender Notice

TDR 55700035
Tendering Authority Delhi Development Authority
Tender No 13/EE(E)/ELD-2/DDA/2026-27
Tender ID 2026_DDA_910458_1
Tender Brief Corrigendum : Tender For maintenance of Dda Open Playground At Qutubgarh Village North Delhi. Sub Head:- Running & Maintenance Of Iei, External Lighting, Pump, Ro, Water Cooler, Split Ac At Dda Open Playground Qutubgarh Village.
City Delhi
State Delhi
Document Fees Refer document
EMD INR 7110.0 /-
Tender Value INR 3.55 Lakhs /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for maintenance of Dda Open Playground At Qutubgarh Village North Delhi. Sub Head:- Running & Maintenance Of Iei, External Lighting, Pump, Ro, Water Cooler, Split Ac At Dda Open Playground Qutubgarh Village.

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 11-06-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 13-06-2026
2 08-06-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 11-06-2026
3 03-06-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 08-06-2026
4 03-06-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 08-06-2026

Key Dates

Publish Date 11-06-2026
Last Date of Bid Submission 13-06-2026
Tender Opening Date 15-06-2026

Contact Information

Company Name Delhi Development Authority
Contact Person Executive Engineer
Address Electrical Division -02, Vikas Minar

BOQ Items

Name of Work:- M/o DDA Open Playground at Qutubgarh Village North Delhi. Sub Head:- Running & Maintenance of IEI, external lighting, pump, RO, water cooler, Split AC at DDA Open Playground Qutubgarh Village.
Sl. No. Item Description
1Running & Maintenance of Internal Electrical Installations, External lighting and Maintenance of submersible pump at Open Playground at Qutubgarh Village as per inventory and Additional conditions enclosed the contractor shall depute following staff :i) 1 No Wiremen for 1 day in a week for 52 week as per direction of site incharge ii)1 No. Khallasi for 1 day in a week for 52 week as per direction of site incharge All tools and plants including tower wagon suitable to maintain fittings mounted up to height 12 mtrs. shall be made available at the site throughout the contract period.
2Comprehensive (Semi) Annual Maintenance of 1 No. RO System 50 LPH capacity connected with water coolers i/c three mandatory services (cleaning of All Filters), repair/ replacement of all electrical and electronic spare parts and one time replacement of consumables once in a year like Particulate Filter 20” or (2 x 10”), Sediment Filter 20” or (2 x 10”), Pre Carbon Filter 20” and Post Carbon Filter 20” (except membranes), attending complaints within 24 working hours with complete overhauling and servicing etc. as required. Dismantle material retained to contracter.
3Replacement of RO TFC Membrane 75 GPD i/c testing, commissioning etc. as required old dismantle shall be retained by the contractor
4Extra Filters Required to be replaced after using its life to enhance the funcioning of the machines. i/c Leak testing, commissioning etc complete as reqd at site. old dismantle shall be retained by the contractor
520\\" Particulate / Sediment Filter
6Supply and replacement of 20'' pre filter spun 5 micron for RO system etc complete as required.
7Supply and replacement of feed water pressure generating pump with automated switch for 50 LPH capacity RO system etc complete as required.
8Supplying and fixing of Automated on/ off Switching Device for Level monitoring of Water cooler in existing 50 LPH RO at site.
9Servicing of water cooler 150 ltr. Capacity oiling in fan motor, Cleaning of base plate and condenser coil with chemical and cleaning of water tank etc. complete as required.
10Supply and replacement of following part in water cooler i/c connection, testing etc. complete as required
11Thermostat
12Over load protection with relay box
13Float Valve Assembly
14Water tap
15Rewinding of fan motor suitable for 150 Ltr capacity water cooler i/c replacement of bushes, testing, commissioning etc. complete as require.
16Service of following type air conditioner of 2.0 ton capacity i/c cleaning of cooling coil & condenser with chemical, washing the complete air-conditioner, painting of sheet metal parts hose plate with synthetic enamel i/c painting of exposed cooling & condenser pipes with anti corrosion paint, oiling of fan motor, etc as required.
17split type
18Supply and charging of refrigerant for 2.0 Ton capacity following type air conditioner of various make i/c testing of pressure and cooling etc. complete as required.
19Split Type /Ref Charging
20Repairing of PCB of Split type AC i/c connection, testing etc. complete as required.
21Supplying and replacement of unserviceable pair of PCB for both indoor unit and out door unit of air conditioner, suitable for various make of 2 Ton inverter type air conditioner i.c connection,testing etc. complete as required.
22Supply and fixing of CO2 type Fire Extinguisher of 4.5 Kg , Duly ISI marked conforming to IS: 15683, complete with delivery hose horn , wheel type release valve, locking arrangement, pressure gauge, operation manual and bracket etc. complete as required.
23Supply and fixing of ABC type Fire Extinguisher of 5 Kg , CE Certified conforming to IS: 4308 , complete with delivery hose horn , wheel type release valve, locking arrangement, pressure gauge, operation manual and bracket etc. complete as required.
24Lifting out of submersible pump set from the exiting bore well up to the required depth along-with existing G.I. pipes and accessories etc. i/c dismantling of G.I pipe and disconnecting the sub. cable etc. complete as reqd.
25Lowering of sub. pump set in the existing bore well up to the required depth along with existing G.I pipe and sub. cableetc , water proof jointing of sub. cable. Replacement of reqd. nuts, bolts, washers and packing, nipple, reducer, connection testing, etc. complete as reqd.
26Repairing and rewinding of Submersible motors of following capacity with cartage, dismantling, reassembling i/c supply & replacement/ repairing of all damaged parts of motors and making good for operation i/c connection, testing, painting etc. complete as required.
27Upto 3 HP single/ three Phase Submersible motor
28Supplying of sub. Pump set duly coupled with suitable rating Three phase, 415 volt, 50Hz, sub. Motor. The pump sets shall be suitable for the following duties. a) Head Range:- 6-55 Mtr. Discharge Range :-450-100 LPM. Minimum HP/Stage:- 3 HP/5 Stage. Outlet Size:-50 mm
29Supplying of copper conductor flat submersible cable of following size i/c testing,connection etc. complete as reqd.
303 x 2.5 sq.mm
31Supplying and fixing following modular switch/ socket on the existing modular plate & switch box includingconnections but excluding modular plate etc. as required.
325/6 A switch
3315/16 A switch
343 pin 5/6 A socket outlet
356 pin 15/16 A socket outlet
36Supplying of following MCB's for Electrical Panel Board/ feeder pillar/ pole including testing etc as required.
376 to 32 Amp SP MCB \\"C\\" series. (10 KA Capacity)
3832 Amp DP MCB \\"C\\" series. (10 KA Capacity)
39Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required.
40100 A,30KA,FPMCCB
41200 A,36KA,FPMCCB
42Supplying and Repalcement (including deduction of cost for replaced item) of PVC insulated copper wire of following size in the existing surface/ recessed conduit i/c connection, testing etc. as required.
433 x 1.5 sq. mm
443 x 2.5 sq. mm
453 x 4 sq. mm
46LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internalsurge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80,UGR (Unified Glare Rating) < 19, Flicker free,(flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved byEngineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housingsuch that LED junction temperature shall not rise above 90°C).Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)36 watt
47LED Batten light (System lumen efficacy ≥105 <120 lm/Watt).Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P.F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required withMinimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm18- 22 Watt Please Enable Macros to View BoQ information

Other Detail

Information Source https://eprocure.gov.in/eprocure/app
Download FileName File Description File Size
Download 9d399260-4c41-410c-8a9f-a6403cf938c7.html Tender Documents 0 KB
Download BOQ_956882.xls Tender Documents 0 KB
Download NIT13.pdf Tender Documents 0 KB
Download Tendernotice_1.pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.