Indian Tenders

Tender Notice

TDR 55699971
Tendering Authority Numaligarh Refinery Limited
Tender No TK-1P22A-MP-RFQ-0114
Tender ID 2026_NRL_910111_1
Tender Brief Corrigendum : Tender For Supply And Installation Of Electrical Works For Msb Unit At Nrep
City Numaligarh
State Assam
Document Fees Refer document
EMD Refer document
Tender Value Refer document
Tender Type Tender
Bidding Type Limitted
Competition Type Indian

Tender Details

Tender for Supply And Installation Of Electrical Works For Msb Unit At Nrep

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 16-06-2026 Addendum_05 Date 22-06-2026
2 12-06-2026 Addendum_04 Other 22-06-2026
3 10-06-2026 Addendum_03 Other 22-06-2026
4 09-06-2026 Addendum_02 Date 15-06-2026
5 09-06-2026 Addendum_02 Date 15-06-2026
6 01-06-2026 Addendum_1 Date 08-06-2026
7 01-06-2026 Addendum_1 Date 08-06-2026
8 01-06-2026 Addendum_1 Date 08-06-2026

Key Dates

Publish Date 16-06-2026
Last Date of Bid Submission 22-06-2026
Tender Opening Date 23-06-2026

Contact Information

Company Name Numaligarh Refinery Limited
Contact Person Mr. Amit Borkar
Address thyssenkrupp Uhde India Pvt Ltd Vikhroli Mumbai India

BOQ Items

Name of Work:- SUPPLY AND INSTALLATION OF ELECTRICAL WORKS FOR MSB UNIT AT NREP
Sl. No. Item Description
1GENERAL NOTESThis document shall be read in conjunction with doc. \\"SCOPE OF SUPPLY-ELECTRICAL\\" DOC ID TK-1P22A-EL-SPE-0022.Technical Specification for the equipment / material to be supplied by CONTRACTOR is included therein.For 'Limit of Variation' in the rates / quantities / total value of work, please refer 'SPECIAL CONDITIONS OF CONTRACT'.Refer the document 'MASTER SUPPLIER LIST' for the makes of equipment / material to be supplied by CONTRACTOR.For all the equipment (suitable for Explosive Atmospheres) to be supplied by CONTRACTOR, relevant certification from applicable recognised approving authority shall be provided. For CONTRACTOR supplied items mentioned below, procurement / supply clearance for the items shall be given to CONTRACTOR, in lots as per Project requirement. Subsequent to the receipt of procurement / supply clearance, CONTRACTOR may initiate the required action in this regard.CONTRACTOR should read entire specification to understand in totality the scope of supply and Installation. Every line item for Supplies and Installation should be read along with the respective Installation standard / hook up drawings related to that specific line item to understand the scope of supply and Installation in totality. Any miss outs in supply scope in this regard by the CONTRACTOR shall not be entertained.Scope shall also include Packing, forwarding and transport to site, unloading and storage in Contractor's warehouse. All Required insturctions shall be followed as per manufacterer recommandation for long term storage.The qouted rates shall include charges for Routine and Type testing, TPI, Packing, forwarding, Insurance, Transportation to site, supply of Mandatory spares, commissioning spares and special tools and tackles.
2EQUIPMENT
3LV PANELS (WALL / CONCRETE / STEEL STRUCTURE MOUNTED)
4LDB / ELDB / DCLDB/ PDB (Industrial type )Supply of LDB / ELDB / DCLDB/ PDB Industrial type ) as per Technical specification for Industrial Equipment (Doc. no.TK-1P22A-EL-SPE-0074 )
5LDB / ELDB Lighting Distribution Board / Emergency Sub Lighting Distribution Board
66 Way
79 Way
812 Way
915 Way
1018 Way
1124 Way
12DCLDB ( Critical Lighting Distribution Board)
136 Way
14PDB (Short time current rating : 9 kA for 1 sec)Auxiliary Power Distribution Board
159 Way
1615 Way
17PDB (Short time current rating : 20 kA for 1 sec)Auxiliary Power Distribution Board
186 Way
1912 Way
2024 Way
21UPSDB (115 VAC)Auxiliary Power Distribution Board
2224 Way
2324 Way with ATS
24LDB / ELDB / DCLDB/ PDB (For Explosive Atmospheres) Supply of LDB / ELDB / DCLDB/ PDB ( For Explosive Atmospheres ) as per Technical Specification for Flameproof Equipment (Doc. no.TK-1P22A-EL-SPE-0019 )
25LDB / ELDB (Gas Group : IIC)Lighting Distribution Board / Emergency Sub Lighting Distribution Board
266 Way
279 Way
2812 Way
2915 Way
3018 Way
31DCLDB (Gas Group : IIC)Critical Lighting Distribution Board
326 Way
339 Way
34PDB (Short time current rating : 9 kA for 1 sec) (Gas Group : IIC)Auxiliary Power Distribution Board
356 Way
369 Way
3712 Way
3815 Way
3918 Way
40NON UPS PDB FOR INSTRUMENTS (125 A, Short time current rating : 20 kA for 1 sec) (Gas Group : IIC)
41PDB for Hydro Jet area (400A) (Gas Group : IIC)
42LOCAL CONTROL STATIONS (LCS)
43Supply of Local Control Stations as per doc. no. TK-1P22A-EL-SPE-0018 (Technical Specification for Local Control Stations)
44LCS Industrial type
45Type H1 : Industrial type weatherproof : Stop PB (Red) Mushroom type, with stay put feature, with pad locking facility, with 2NO+2NC contacts + ON lamp
46LCS for Explosive Atmospheres
47Type A3 : Flameproof (Gas Group : IIC) : Start PB (Green); Stop PB (Red) with stay put feature, shrouded type, with pad locking facility & each PB shall have 2NO+2NC contacts
48Type B3 :Flameproof (Gas Group : IIC) : Start PB (Green, shrouded type); Stop PB (Red) Mushroom type, with stay put feature, with pad locking facility & each PB shall have 2NO+2NC contacts & Ammeter (1A, MI type)
49Type D3 : Flameproof (Gas Group : IIC) : Start PB (Green, shrouded type); Stop PB (Red) Mushroom type, with stay put feature, with pad locking facility & each PB shall have 2NO+2NC contacts. With Local/ Remote Selector switch lockable in both the positions, Key shall be removable only in OFF position & Ammeter (1A, MI type)
50Type F4 :Flameproof (Gas Group : IIC) : Start PB (Green, shrouded type); Stop PB (Red), shrouded type; Key lockable emergency stop PB (Red), Mushroom type, with stay put feature, with pad locking facility; each PB shall have 2NO+2NC contacts; Ammeter (4-20mA); Analog RPM meter (4-20mA); key lockable A-M selector switch; Speed Lower-Speed Raise Push buttons
51Type F5 :Flameproof (Gas Group : IIC) : Start PB (Green, shrouded type); Stop PB (Red), shrouded type; Key lockable emergency stop PB (Red), Mushroom type, with stay put feature, with pad locking facility; each PB shall have 2NO+2NC contacts; Ammeter-2 Nos. (4-20mA); Analog RPM meter (4-20mA); key lockable A-M selector switch; Speed Lower-Speed Raise Push buttons
52Type J3 :Flameproof (Gas Group : IIC) : Stop PB (Red), Mushroom type, with stay put feature, with pad locking facility & with 2NO+2NC contacts
53Type L3 :Flameproof (Gas Group : IIC) :Trip-Neutral-Close (T-N-C) switch shall be spring return to neutral type from CLOSE position with two contacts each for time stamping & tripping signal. Switch shall be lockable in TRIP position. With Local/ Remote Selector switch lockable in both the positions, Key shall be removable only in OFF position & Ammeter (1A, MI type) (Configuration: T-N-C SWITCH + L/R SWITCH+ AMMETER )
54Type L4 :Flameproof (Gas Group : IIC) :Trip-Neutral-Close (T-N-C) switch shall be spring return to neutral type from CLOSE position with two contacts each for time stamping & tripping signal. Switch shall be lockable in TRIP position. & Ammeter (1A, MI type) (Configuration: T-N-C SWITCH + AMMETER + RUN INDICATION + TRIP INDICATION)
55Type P3 :Flameproof (Gas Group : IIC) :Trip-Neutral-Close (T-N-C) switch shall be spring return to neutral type from CLOSE position with two contacts each for time stamping & tripping signal. Switch shall be lockable in TRIP position & Ammeter (1A, MI type)
56ELECTRICAL HEAT TRACING SYSTEM
57Supply of Heat Tracing System comprising Power Distribution Board-cum-Control Panel, Heat Tracers and Accessories (Connector, Junction Box, fastening material, etc.), Temp. sensing elements, Thermostats, etc. as per Specification (Doc no. TK-1P22A-EL-SPE-0031)The scope includes design, engineering, manufacturing, inspection and testing at vendor’s works, packing, forwarding, supply to site.
58Unit rates for addition/ deletion of following items during detailed engineering.
59Self regulating heat tracer
60Power Limiting heat tracer
61Mineral insulated heat tracer
62Power Junction Box
63End Junction Box
64Multiple entry power connection and tee
65Small pipe adaptor
66Insulation Entry Kit
67Thermostat (with Kit)
68CABLES AND WIRES, GLANDING, TERMINATIONS AND CABLE ROUTING SYSTEMS
69CABLES AND WIRESSupply of armoured / unarmoured power / control / lighting / earthing . Communication cables of various sizes as per technical specifications attached with the Tender
70Earthing cablesSupply of MV / LV Cables as per the document attached elsewhere in the tender650/1100V Al / Cu conductor, PVC insulated, unarmoured earthing cables
711 C x 6 sq.mm Cu Stranded, PVC insulated Green/Yellow cable
721 C x 16 sq.mm Cu Stranded, PVC insulated Green/Yellow cable
731 C x 25 sq.mm Cu Stranded, PVC insulated Green/Yellow cable
741 C x 50 sq.mm Cu Stranded, PVC insulated Green/Yellow cable
751 C x 95 sq.mm Cu Stranded, PVC insulated Green/Yellow cable
761 C x 25 sq.mm Al Stranded, PVC insulated Green/Yellow cable
771 C x 35 sq.mm Al Stranded, PVC insulated Green/Yellow cable
781 C x 50 sq.mm Al Stranded, PVC insulated Green/Yellow cable
791 C x 70 sq.mm Al Stranded, PVC insulated Green/Yellow cable
801 C x 120 sq.mm Al Stranded, PVC insulated Green/Yellow cable
81GI Wire ropes
828 mm dia. GI wire rope
8310 MM (3/8\\") DIA G.I WIRE ROPE
8416 MM (5/8\\") DIA G.I WIRE ROPE
85Supply of 650V / 1100V (Uo / U) voltage grade, Multistranded Cu conductor, PVC insulated, flexible cable, FRLS
863C x 2.5 sq.mm
87Supply of single Core, Annealed Tinned Copper Conductor, cables with Fiber Glass, (Uninyvin, cable size : 1C x 109 sqmm)
88Ehernet Cable (UTP CAT6e Cable)
89CABLE GLANDING AND TERMINATION (HV)
90HV Cable glands Industrial type
91Supply of cable glands HV cable glands industrial type and all the associated accessories as per 'ANNEXURE-II to SCC - SCOPE OF SUPPLY - ELECTRICAL'.CONTRACTOR shall be responsible selection and supply of exactly suitable cable glands for the actual cables (technical particulars as per project technical specification) installed at site and equipment cable entry tread.'OD' mentioned below indicate approximate overall cable diameters.
92HV Cable gland suitable for 6.6 / 6.6 kV (UE) voltage grade, Al/Cu conductor, XLPE insulated, screened, armoured power cable
933C x 240 sq.mm A2XCEFY (OD : 68 mm)
941C x 630 sq.mm A2XCEWaY (OD : 70 mm)
95HV Cable gland suitable for 33 / 33 kV (UE) voltage grade, Al/Cu conductor, XLPE insulated, screened, armoured power cable
961C x 630 sq.mm A2XCEWaY (OD : 70 mm)
97HV Cable glands for Explosive Atmospheres
98Supply of cable glands HV cable glands industrial type and all the associated accessories as per 'ANNEXURE-II to SCC - SCOPE OF SUPPLY - ELECTRICAL'.CONTRACTOR shall be responsible selection and supply of exactly suitable cable glands for the actual cables (technical particulars as per project technical specification) installed at site and equipment cable entry tread.'OD' mentioned below indicate approximate overall cable diameters.
99HV Cable gland suitable for 6.6 / 6.6 kV (UE) voltage grade, Al/Cu conductor, XLPE insulated, screened, armoured power cable
1003C x 240 sq.mm A2XCEFY (OD : 68 mm)
101HV Cable termination kit
102Supply of HV cable termination kit along with all the associated accessories and suitable tinned copper lug for cable termination at designated location.CONTRACTOR shall be responsible for selection and supply of exactly suitable cable termination kit for the cables (technical particulars as per project technical specification) as per the required site conditions and available termination arrangement, and as per the cable technical specification.
103HV Cable termination kit Heat shrinkable type (suitable for indoor installation) for 6.6 / 6.6 kV (UE) voltage grade, Al conductor, XLPE insulated, screened, armoured power cable
1043C x 240 sq.mm A2XCEFY
1051C x 630 sq.mm A2XCEFY
106HV Cable termination kit Heat shrinkable type (suitable for indoor installation) for 33 / 33 kV (UE) voltage grade, Al conductor, XLPE insulated, screened, armoured power cable
1071C x 630 sq.mm A2XCEWaY
108CABLE GLANDING AND TERMINATION (MV)
109MV Cable glands Industrial type
110Supply of cable glands MV cable glands industrial type and all the associated accessories as per 'ANNEXURE-II to SCC - SCOPE OF SUPPLY - ELECTRICAL'.CONTRACTOR shall be responsible selection and supply of exactly suitable cable glands for the actual cables (technical particulars as per project technical specification) installed at site and equipment cable entry tread.'OD' mentioned below indicate approximate overall cable diameters.
111Cable glands suitable for 650 / 1100 V (Uo / U) voltage grade, Al / Cu conductor (stranded / solid), XLPE insulated, screened, armoured power / control / lighting cables Cable Glands shall be of Nickel plated brass material, double compression type with PVC hood.
112Cables with OD upto 20 mm.
113Cables with OD above 20 mm but upto 30 mm.
114Cables with OD above 30 mm but upto 40 mm.
115Cables with OD above 40 mm but upto 50 mm
116Cables with OD above 50 mm but upto 60 mm.
117Cables with OD above 60 mm but upto 80 mm.
118Cable glands suitable for 650 / 1100 V (Uo / U) voltage grade, Al / Cu conductor (stranded / solid), XLPE insulated, unarmoured power cables (for battery banks)Cable Glands shall be of Nickel plated brass with PVC hood / Nylon , single compression type .
119Cables with OD upto 20 mm.
120Cables with OD above 20 mm but upto 30 mm.
121MV Cable glands for Explosive Atmospheres
122Supply of cable glands MV cable glands for Explosive Atmospheres and all the associated accessories as per 'ANNEXURE-II to SCC - SCOPE OF SUPPLY - ELECTRICAL'.CONTRACTOR shall be responsible selection and supply of exactly suitable cable glands for the actual cables (technical particulars as per project technical specification) installed at site and equipment cable entry tread.'OD' mentioned below indicate approximate overall cable diameters.
123Cable glands suitable for 650 / 1100 V (Uo / U) voltage grade, Al / Cu conductor (stranded / solid), XLPE insulated, screened, armoured power / control / lighting cables Cable Glands shall be of Nickel plated brass material, double compression type with PVC hood.
124Cables with OD upto 20 mm.
125Cables with OD above 20 mm but upto 30 mm.
126Cables with OD above 30 mm but upto 40 mm.
127Cables with OD above 40 mm but upto 50 mm
128Cables with OD above 50 mm but upto 60 mm.
129Cables with OD above 60 mm but upto 80 mm.
130MV Cable gland reducers / expanders
131Supply of MV Cable gland reducers / expanders and all the associated accessories as per 'ANNEXURE-II to SCC - SCOPE OF SUPPLY - ELECTRICAL'.CONTRACTOR shall be responsible selection and supply of exactly suitable reducers / expanders for the actual cables gland (technical particulars as per project technical specification) installed at site and equipment cable entry tread
132MV Cable gland reducers - Industrial type
133M20 x 1.5 (Male thread) to M16 x 1.5 (Female thread)
134M25 x 1.5 (Male thread) to M20 x 1.5 (Female thread)
135M32 x 1.5 (Male thread) to M25 x 1.5 (Female thread)
136M50 x 1.5 (Male thread) to M32 x 1.5 (Female thread)
137M63 x 1.5 (Male thread) to M50 x 1.5 (Female thread)
138M80 x 1.5 (Male thread) to M63 x 1.5 (Female thread)
139MV Cable gland expander Industrial type
140M16 x 1.5 (Male thread) to M20 x 1.5 (Female thread)
141M20 x 1.5 (Male thread) to M25 x 1.5 (Female thread)
142M25 x 1.5 (Male thread) to M32 x 1.5 (Female thread)
143M32 x 1.5 (Male thread) to M50 x 1.5 (Female thread)
144M50 x 1.5 (Male thread) to M63 x 1.5 (Female thread)
145M63 x 1.5 (Male thread) to M80 x 1.5 (Female thread)
146MV Cable gland reducers for Explosive Atmospheres
147M20 x 1.5 (Male thread) to M16 x 1.5 (Female thread)
148M25 x 1.5 (Male thread) to M20 x 1.5 (Female thread)
149M32 x 1.5 (Male thread) to M25 x 1.5 (Female thread)
150M50 x 1.5 (Male thread) to M32 x 1.5 (Female thread)
151M63 x 1.5 (Male thread) to M50 x 1.5 (Female thread)
152M80 x 1.5 (Male thread) to M63 x 1.5 (Female thread)
153LV Cable gland expander for Explosive Atmospheres
154M16 x 1.5 (Male thread) to M20 x 1.5 (Female thread)
155M20 x 1.5 (Male thread) to M25 x 1.5 (Female thread)
156M25 x 1.5 (Male thread) to M32 x 1.5 (Female thread)
157M32 x 1.5 (Male thread) to M50 x 1.5 (Female thread)
158M50 x 1.5 (Male thread) to M63 x 1.5 (Female thread)
159M63 x 1.5 (Male thread) to M80 x 1.5 (Female thread)
160Cable entry blanking plugs
161Supply of cable entry blanking plugs and all the associated accessories for sealing of unused cable entries, as per 'ANNEXURE-II to SCC - SCOPE OF SUPPLY - ELECTRICAL'.CONTRACTOR shall be responsible selection and supply of exactly suitable Cable entry blanking plugs as per equipment cable entry tread at site.
162Cable entry blanking plugs Industrial type
163Cable entry blanking plugs For Explosive Atmospheres
164Cable Lugs:Supply of crimping type lugs for power / control / lighting / earthing cables of various sizes along with all the associated accessories including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.Supply of lugs are included in Termination cost, this item shall be operated only in case of re-termination/ re-lugging due to Owner/ Consultant's instructions. This item shall not be operated due to fault of Contractor.
165Supply of crimping type TINNED COPPER LUGS lugs for power / control / lighting / earthing cables of various sizes.CONTRACTOR shall be responsible selection and supply of exactly suitable lug for the actual cable conductors for the cables (technical particulars as per project technical specification) installed at site and available termination arrangement.
166All sizes upto 16 sq. mm. (Lugs shall be heavy duty and long barrel crimping type)
167All sizes from 25 to 35 sq. mm. (Lugs shall be heavy duty and long barrel crimping type)
168All sizes from 50 to 185 sq. mm. (Lugs shall be heavy duty and long barrel crimping type)
169All sizes from 240 to 400 sq. mm. (Lugs shall be heavy duty and long barrel crimping type)
170All sizes from 500 to 630 sq. mm. (Lugs shall be heavy duty and long barrel crimping type)
171Supply of crimping type AL LUGS lugs for power / control / lighting / earthing cables of various sizes.CONTRACTOR shall be responsible selection and supply of exactly suitable lug for the actual cable conductors for the cables (technical particulars as per project technical specification) installed at site and available termination arrangement.
172All sizes from 25 to 35 sq. mm. (Lugs shall be heavy duty and long barrel crimping type)
173All sizes from 50 to 185 sq. mm. (Lugs shall be heavy duty and long barrel crimping type)
174All sizes from 240 to 400 sq. mm. (Lugs shall be heavy duty and long barrel crimping type)
175Supply of crimping type TINNED COPPER LUGS lugs for power / control / lighting / earthing cables of various sizes.CONTRACTOR shall be responsible selection and supply of exactly suitable lug for the actual cable conductors for the cables (technical particulars as per project technical specification) installed at site and available termination arrangement.
1761.5 sq. mm. (Lugs shall be insulated, Ring / Pin / Fork crimping type)
1772.5 sq. mm. (Lugs shall be insulated, Ring / Pin / Fork crimping type)
178All sizes from 4 sq.mm. to 10 sq. mm. (Lugs shall be insulated,Ring / Pin / Fork crimping type)
179Supply of crimping type lugs for below mentioned GI wire ropes of various sizes.CONTRACTOR shall be responsible selection and supply of exactly suitable lug for the actual cable conductors for the cables (technical particulars as per project technical specification) installed at site and available termination arrangement.
18010 mm dia. GI wire rope
18116 mm dia. GI wire rope
182CABLE JOINTING
183Cable straight through jointing kit
184Supply of cable jointing kit along with all the associated accessories as per 'ANNEXURE-II to SCC - SCOPE OF SUPPLY - ELECTRICAL'.
185HV Cable straight through jointing kit Heat shrinkable type (suitable for outdoor installation) for 6.6 / 6.6 kV (UE) voltage grade, Al conductor, XLPE insulated, screened, armoured power cable
1863C x 240 sq.mm A2XCEFY (UE)
187HV Cable straight through jointing kit Heat shrinkable type (suitable for outdoor installation) for 33 / 33 kV (UE) voltage grade, Al conductor, XLPE insulated, screened, armoured power cable
1881C x 630 sq.mm A2XCEWaY (UE)
189MV Cable straight through jointing kit (suitable for outdoor installation) for 650 / 1100 (Uo / U) voltage grade, Al / Cu conductor (stranded / solid), XLPE insulated, screened, armoured power / control / lighting cables
190Cables with OD upto 20 mm.
191Cables with OD above 20 mm but upto 30 mm.
192Cables with OD above 30 mm but upto 40 mm.
193Cables with OD above 40 mm but upto 50 mm.
194Cables with OD above 50 mm but upto 60 mm.
195Cables with OD above 60 mm but upto 80 mm.
196PREFABRICATED CABLE TRAYS
197Prefabricated Cable Trays (GI) and accessories
198Supply of prefabricated GI perforated and ladder type cable tray / covers, tray separators along with all the associated consumable material for assembly and appropriate installation of the same, as per doc. no. TK-1P22A-EL-SPE-0024 (Technical Specification for GI cable Trays)
199Cable Trays Perforated (GI)
20050 mm wide
201100 mm wide
202150 mm wide
203Coupler plates along with SS304 fixing hardware
204GI Coupler plates with 3 mm thick, along with necessary fixing hardware – stainless steel (SS304) nut, bolt, lock-nut) for 50/100/150 W perforated cable trays mentioned above. (Note : 1 no. set = 2 nos. coupler plates each)
205GI Coupler plates with 2 mm thick, along with necessary fixing hardware – stainless steel (SS304) nut, bolt, lock-nut) for 50/100/150 W perforated cable trays mentioned above. (Note : 1 no. set = 2 nos. coupler plates each
206Cable Ladders (GI) and Accessories
207150 mm wide
208300 mm wide
209600 mm wide
210Prefabricated Bends and Accessories Cable Ladders (GI)
211Pre-Fabricated 90 degree horizontal bends (Bending Radius 300mm)
212300 mm wide
213600 mm wide
214Pre-Fabricated 90 degree horizontal bends (Bending Radius 600mm)
215300 mm wide
216600 mm wide
217Pre-Fabricated 90 degree horizontal bends (Bending Radius 900mm)
218300 mm wide
219600 mm wide
220Pre-Fabricated 90 degree horizontal bends (Bending Radius 1200mm)
221300 mm wide
222600 mm wide
223Pre-Fabricated 90 degree Inside Vertical bends (Bending Radius 300mm)
224300 mm wide
225600 mm wide
226Pre-Fabricated 90 degree Inside Vertical bends (Bending Radius 600mm)
227300 mm wide
228600 mm wide
229Pre-Fabricated 90 degree Inside Vertical bends (Bending Radius 900mm)
230300 mm wide
231600 mm wide
232Pre-Fabricated 90 degree Inside Vertical bends (Bending Radius 1200mm)
233300 mm wide
234600 mm wide
235Pre-Fabricated 90 degree Outside Vertical bends (Bending Radius 300mm)
236300 mm wide
237600 mm wide
238Pre-Fabricated 90 degree Outside Vertical bends (Bending Radius 600mm)
239300 mm wide
240600 mm wide
241Pre-Fabricated 90 degree Outside Vertical bends (Bending Radius 900mm)
242300 mm wide
243600 mm wide
244Pre-Fabricated 90 degree Outside Vertical bends (Bending Radius 1200mm)
245300 mm wide
246600 mm wide
247Pre-Fabricated 45 degree horizontal bends (Bending Radius 300mm)
248300 mm wide
249600 mm wide
250Pre-Fabricated 45 degree horizontal bends (Bending Radius 600mm)
251300 mm wide
252600 mm wide
253Pre-Fabricated 45 degree horizontal bends (Bending Radius 900mm)
254300 mm wide
255600 mm wide
256Pre-Fabricated 45 degree Inside Vertical bends (Bending Radius 300mm)
257300 mm wide
258600 mm wide
259Pre-Fabricated 45 degree Inside Vertical bends (Bending Radius 600mm)
260300 mm wide
261600 mm wide
262Pre-Fabricated 45 degree Inside Vertical bends (Bending Radius 900mm)
263300 mm wide
264600 mm wide
265Pre-Fabricated 45 degree Outside Vertical bends (Bending Radius 300mm)
266300 mm wide
267600 mm wide
268Pre-Fabricated 45 degree Outside Vertical bends (Bending Radius 600mm)
269300 mm wide
270600 mm wide
271Pre-Fabricated 45 degree Outside Vertical bends (Bending Radius 900mm)
272300 mm wide
273600 mm wide
274Pre Fabricated Cable Tray Reducer
275600 to 300 mm Reducer, Right Hand Side
276600 to 300 mm Reducer, Left Hand Side
277300 to 150 mm Reducer, Right Hand Side
278300 to 150 mm Reducer, Left Hand Side
279Pre Fabricated Equal Tee’s (Bending Radius-300 mm)
280300 mm wide
281600 mm wide
282Pre Fabricated Equal Tee’s (Bending Radius-600 mm)
283300 mm wide
284600 mm wide
285Pre Fabricated Equal Tee’s (Bending Radius-900 mm)
286300 mm wide
287600 mm wide
288Pre Fabricated Unequal Tee’s (Bending Radius-300 mm)
289300 x 150 x 300 mm wide
290600 x 150 x 600 mm wide
291600 x 300 x 600 mm wide
292Pre Fabricated Unequal Tee’s (Bending Radius-600 mm)
293300 x 150 x 300 mm wide
294600 x 150 x 600 mm wide
295600 x 300 x 600 mm wide
296Coupler plates along with SS304 fixing hardware
297GI Coupler plates with 3 mm thick, 4 holes on both the sides of size M10 hole & M8 hardware (along with necessary fixing hardware – stainless steel nut, bolt, lock-nut) for 150/300/450/600 W ladder type cable trays mentioned above. (Note : 1 no. set = 4 nos. coupler plates each)
298Stainless Steel Coupler plates with 2 mm thick, 4 holes on both the sides of size M10 hole & M8 hardware (along with necessary fixing hardware – stainless steel nut, bolt, lock-nut) for 150/300/450/600 W ladder type cable trays mentioned above. (Note : 1 no. set = 4 nos. coupler plates each)
299Hinges along with SS304 fixing hardware
300Hinged GI plates 3 mm thick, 80 mm height along with necessary fixing hardware – stainless steel (SS304) nut, bolt, lock-nut) suitable for tray size 300/450/600 mm W (Note : 1 no. set = 4 nos. coupler plates each)
301Hinged GI plates 2 mm thick, 80 mm height along with necessary fixing hardware – stainless steel (SS304) nut, bolt, lock-nut) suitable for tray size 300/450/600 mm W (Note : 1 no. set = 4 nos. coupler plates each)
302Tray Covers with fixing clamps along with necessary SS304 hardware
303100 mm wide
304150 mm wide
305300 mm wide
306600 mm wide
307Hold Down Clamps (HDGI)
308Hold down Clamps (HDGI) for Horizontal Ladder Cable Tray with necessary SS 304 fixing hardware
309Hold down Clamps (HDGI) for Vertical Ladder Cable Tray with necessary SS 304 fixing hardware
310Separators for Cable Ladders (GI) with necessart SS 304 fixing hardware
311CONDUITS FOR CABLE LAYING / PROTECTION AND PULL BOXES
312Supply of heavy duty rigid GI / PVC conduits and all the associated accessoriesSupply of accessories such as GI clamps, joints, bends reducers / adaptors for the conduits and other consumable material such as edge protection grommet at either ends for GI conduits as per the site requirement is considered in running meter length of the conduits.
313Rigid GI conduits
31425 mm nominal dia
31550 mm nominal dia
316100 mm nominal dia
317150 mm nominal dia
318Rigid GI conduits RED coloured (For Fire Alarm System cables)
31925 mm nominal dia
32050 mm nominal dia
321Heavy duty PVC conduits
32225 mm nominal dia
32350 mm nominal dia
324Flexible PVC conduits
32525 mm nominal dia
326Pull boxes for cable pulling in conduits
327Supply of pull boxes (GI enclosure) indicate below excludes pull boxes already covered in the section \\"Point Wiring for Office buildings / Control rooms / Other rooms with false ceiling\\"
3284 way Pull boxes,100mm L x 100mm W x 75mm D, 1no. 25mm knockout on all four sides
329LIGHTING, SMALL POWER, WELDING SOCKETS AND JUNCTION BOXES
330LIGHTING
331Lighting fixtures
332Supply of lighting fixtures and associated components / accessories such as lamps, chokes, condensers, reflectors for integral fixtures including certified glands, PVC hood and lugs, entry plugs etc. including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.
333Lighting Fixtures Industrial type Refer specification TK-1P22A-EL-SPE-0017 for LED type Industrial Light Fittings
3341x40W LED Tube Light Fixture
3352x20W LED Tube Light Fixture
33610W LED Bulkhead Light Fixture
33711W LED Decorative Down Light fixture suitable for false ceiling
33836W LED recessed mounted square (600 mm X 600 mm) fixture suitable for False Ceiling
33918W LED (suitable for 110V DC) recessed mounted square (600 mm X 600 mm) fixture suitable for False Ceiling
3401 X 45W LED, Well Glass Integral Luminaire
3411X26W,(suitable for 110V DC) LED Tube Light Fixture
342Lighting Fixtures for Explosive AtmospheresRefer specification TK-1P22A-EL-SPE-0020 for LED type Light Fittings for Explosive Atmospheres.
3431 X 45W LED, Ex'd', IIC, T3 Well Glass Integral Luminaire
3441 X 26W (suitable for 110V DC) LED, Ex'd', IIC, T3 Well Glass Integral Luminaire
3451 X 100W LED, Ex'd', IIC, T3 Medium Bay / High Bay Integral Luminaire
3461 X 150W LED, Ex'd', IIC, T3 Medium Bay / High Bay Integral Luminaire
3471 X 250W LED, Ex'd', IIC, T3 Medium Bay / High Bay Integral Luminaire
3481 X 150W LED, Ex'd', IIC, T3 Flood Light Luminaire
349LED aviation light Ex d, IIC, T3 (15W) with control panel. Colour of lamp and type (steady/ falshing) will be informed during Detailed Engineering.
3501X40W LED Tube light fixture , Ex'd', IIC, T3
351Special Lighting fixtures
352Supply of special lighting fixtures and all the associated accessories, as per 'ANNEXURE-II to SCC - SCOPE OF SUPPLY - ELECTRICAL'.
353Emergency lighting fixture with built-in battery
3541x18W, Fluorescent, Industrial
3551x18W, Fluorescent, for Explosive Atmospheres
356Emergency EXIT sign with built-in battery
357Refer 'ANNEXURE-II to SCC - SCOPE OF SUPPLY - ELECTRICAL' for the 'Type designations' (TYPE-1, TYPE-2 etc.) mentioned below.
358TYPE-1
359TYPE-2
360Hand lamps
36124V Industrial Hand lamps along with 20 m extension cable 3C x 2.5sq.mm, YY, 20m, along with the plug suitable for 24V, 5A Industrial switch socket
36224V Hand lamps for Explosive Atmospheres (Zone1/Zone2, Ex-d, IIC, T3, ) alongwith 20 m extension cable 3c x 2.5sq.mm, YY long with the plug suitable for 24V, 5A Industrial switch socket
363Supply of Lighting PolesSupply of GI lighting pole as per approved drawing along with supply of fixing hardware like U clamp & bolt, for platform mounted pole
364Installation details : L04
365Installation details : L05
366Installation details : L11
367Installation details : L14A
368EXHAUST FANS AND CEILING FANS
369Industrial type Exhaust fans
370Supply of Industrial type Exhaust fans and associated accessories such as louvers and bird screen, as per 'ANNEXURE-II to SCC - SCOPE OF SUPPLY - ELECTRICAL'.
371300mm dia.
372450mm dia.
373600mm dia.
374Exhaust fans for Explosive Atmospheres
375Supply of Exhaust fans for Explosive Atmospheres and associated accessories such as louvers and bird screen, as per 'ANNEXURE-II to SCC - SCOPE OF SUPPLY - ELECTRICAL'.
376300mm dia.
377450mm dia.
378600mm dia.
379SMALL POWER
380Supply of various small power equipment and all associated accessories, as per 'ANNEXURE-II to SCC - SCOPE OF SUPPLY - ELECTRICAL'.
381Switch socket outlets
382Supply of Decorative type switch socket outletsSupply of Supply of Decorative type switch socket outlets as per 'ANNEXURE-II to SCC - SCOPE OF SUPPLY - ELECTRICAL'.
383Decorative type switch socket box with 1 no. 5/15A switch socket unit and 1 no. piano type switch
384Decorative type switch socket box with 1 no. 5/15A switch socket unit and 2 nos. piano type switches
385Decorative type switch socket box with 1 no. 5/15A switch socket unit and 3 nos. piano type switches
386Decorative type switch socket box with 1 no. 5/15A switch socket unit and 4 nos. piano type switches
387Decorative type switch socket box with 1 no. 5/15A switch socket unit and 5 nos. piano type switches
388Decorative type switch socket box with 1 no. 5/15A switch socket unit
389Decorative type switch in single module with 1 no. 5A piano type switches
390Decorative type switch in double module with 2 no. 5A piano type switches
391Decorative type switch in tripple module with 3 no. 5A piano type switches
392Decorative type switch in quad module with 4 no. 5A piano type switches
393Decorative type switch socket switchboard with 5/15A, 5 pin, socket outlet with 15A switch and 'ON' LED indication & fuse
394Surface / Concealed mounting type ( 2-Module) RJ 11 / RJ 45 Connectors Female type complete with Moduler box, cover plate etc. for telephones
395Industrial type switch socket outlets (for Indoor Installation) Supply of Industrial type switch socket outlets (for Indoor Installation) as per 'ANNEXURE-II to SCC - SCOPE OF SUPPLY - ELECTRICAL'.
39620A, single phase switch socket outlet with 1no. 3 pin socket and 1 No. 20 A, 10 kA, SPMCB, in sheet steel enclosure
397Convenience Switch socket outlets Supply of Convenience Switch socket outlets as per 'ANNEXURE-II to SCC - SCOPE OF SUPPLY - ELECTRICAL'.
398Industrial Convenience sockets (single phase)
39916A, 240 V 3 pin single phase socket outlet
400Convenience sockets (single phase) for Explosive Atmospheres
40116A, 3 pin,240V AC single phase socket outlet (Ex-d , IIC , T3)
402Industrial switch socket unit (portable)
40324V, 5A Industrial switch socket unit with built-in 100VA, 220V / 24V transformer
404Switch socket unit for Explosive Atmospheres
405240V,16A and 24V, 5A combination type switch socket unit for Explosive Atmospheres (Zone 1/2, Ex-d , IIC , T3), with built-in 100VA, 240V / 24V transformer
406240V,16A and 24V, 5A combination type switch socket unit for Explosive Atmospheres (Zone 1/2, Ex-d , IIC , T3), with built-in 100VA, 240V / 24V transformer (Portable Handlamp Sockets supplied with trolleys)
407JUNCTION BOXES (JB) / POWER JUNCTION BOXES (JB)
408Supply of various types of junction boxes / power junction boxes suitable for the required cable entries and all associated accessories, as per doc. no.TK-1P22A-EL-SPE-0074 (Technical specification for Industrial Lighting & Small Power Panels, Junction Boxes & Welding Receptacles) and TK-1P22A-EL-SPE-0019 (Technical Specification for Flameproof Industrial Lighting & Small Power Panels, Junction Boxes & Welding Receptacles)Supply of junction boxes suitable for bottom entry of incoming and outgoing cables, inclusive of suitable terminals for undrilled gland plate, cable terminations, busbars for cable termination as required, facility for earthing cable termination inside and outside the termination, along with the associated accessories such plugs for cable openings, fixing hardware
409Junction boxes Industrial type
410Junction boxes (Indoor)
4114 way Lighting JB, Indoor
4125 way JB for small power sockets , Indoor
413Junction boxes (Outdoor)
4144 way Lighting JB, Outdoor
4154 way Welding socket JB, Outdoor
416Communication System Junction BoxesSupply of Industrial Weatherproof Junction boxes as per 'ANNEXURE-II to SCC - SCOPE OF SUPPLY - ELECTRICAL'.Supply of cable glands, cable blanking plugs suitable to cable OD, cable entry size is included in the scope
417Indoor FA System JB For housing addressable module of 1 no. Exit LightIncoming : 2Px1.5 sq.mm(1 No.) - M25 + 1Px2.5 sq.mm(1 No.) - M20Outgoing : 2Px1.5 sq.mm(1 No.) - M25 + 1Px2.5 sq.mm(1 No.) - M20
418Indoor FA System JB Incoming : 2Px1.5 sq.mm(1 No.) - M25Outgoing : 2Px1.5 sq.mm(1 No.) - M25
419Indoor PA System JB for SpeakersIncoming : up to 20Px2.5 sq.mm(1 No.) - M40Outgoing : 2Px2.5 sq.mm(12 Nos.) - M25 (9 Nos. Gland + 3 Nos. Plug)
420Outdoor PA System JB for SpeakersIncoming : up to 12Px2.5 sq.mm(1 No.) - M40Outgoing : 2Px2.5 sq.mm(12 Nos.) - M25 (9 Nos. Gland + 3 Nos. Plug)
421Indoor PA System JB for FCSIncoming : up to 20Px2.5 sq.mm(1 No.) - M40Outgoing : 2Px2.5 sq.mm(12 Nos.) - M25 (9 Nos. Gland + 3 Nos. Plug)
422Indoor Telephone System JB (IDF)Industrial Weatherproof type telephone system junction box /IDF Krone/screw type terminals, including termination and connections of incoming and outgoing telephone cableJB / IDF with 1 nos 20 Pair incoming cable(s) and 20 nos 2 Pair outgoing cable(s)
423Junction boxes for Explosive Atmospheres
4244 way Lighting JB, (Ex-d, IIC , T3)
4255 way JB for small power sockets, (Ex-d, IIC , T3)
4264 way Welding socket JB, (Ex-d, IIC , T3)
427Junction box (Ex-d, IIC , T3) suitable for 415 V system suitable for Incoming cable size 3R-3Cx240sq.mm and outgoing cable size 2R-3Cx240sq.mm
428Junction boxes for Communication System Supply of Industrial Weatherproof Junction boxes as per 'ANNEXURE-II to SCC - SCOPE OF SUPPLY - ELECTRICAL'.Supply of cable glands, cable blanking plugs suitable to cable OD, cable entry size is included in the scope
429Indoor FA System JB for housing addressable module of 1 no. DetectorIncoming : 2Px1.5 (1 No.)Outgoing : 2Px1.5 (1 No.), 1Px1.5 (1 Nos.)NPT thread glands : 3 Nos.Plugs : 2 Nos. (Plug for 2Px1.5 size)
430Indoor FA System JB Incoming : 2Px1.5 (1 No.)Outgoing : 2Px1.5 (1 No.), 1Px1.5 (1 Nos.)NPT thread glands : 3 Nos.Plugs : 2 Nos. (Plug for 2Px1.5 size)
431Outdoor FA System JB for housing addressable module of 1 no. MCPIncoming : 2Px1.5 (1 No.)Outgoing : 2Px1.5 (1 No.), 1Px1.5 (1 Nos.)NPT thread glands : 3 Nos.Plugs : 2 Nos. (Plug for 2Px1.5 size)
432Outdoor FA System JB for housing addressable module of 1 no. Hooter / BeconIncoming : 2Px1.5 (1 No.)Outgoing : 2Px1.5 (1 No.), 1Px2.5 (1 Nos.)NPT thread glands : 3 Nos.Plugs : 2 Nos. (Plug for 2Px1.5 size)
433Outdoor FA System JB for housing addressable module of 1 no. DetectorIncoming : 2Px1.5 (1 No.)Outgoing : 2Px1.5 (1 No.), 1Px1.5 (1 Nos.)NPT thread glands : 3 Nos.Plugs : 2 Nos. (Plug for 2Px1.5 size)
434Outdoor FA System JB for Housing 2 addressable modules and 2 zener barrierIncoming : 2Px1.5 (1 No.)Outgoing : 2Px1.5 (1 No.), 1Px1.5 (2 Nos.)NPT thread glands : 4 Nos.Plugs : 2 Nos. (Plug for 2Px1.5 size)
435Outdoor FA System JB for End of resistor / Fault Isolator in FA loopIncoming : 2Px1.5 (1 No.)Outgoing : 2Px1.5 (1 No.)NPT thread glands : 2 Nos.Plugs : 2 Nos. (Plug for 2Px1.5 size)
436Indoor Telephone System JB (IDF)Flameproof type telephone system junction box /IDF 9Ex-d, IIC,T3) Krone/screw type terminals, including termination and connections of incoming and outgoing telephone cableJB / IDF with 1 nos 20 Pair incoming cable(s) and 20 nos 2 Pair outgoing cable(s)
437Outdoor PA System JB for FCSIncoming : 12Px1.5 (1 No.)Outgoing : 2Px1.5 (6 Nos.) NPT thread glands : 7 Nos.Plugs : 2 Nos. (1 No. Plug for 12Px1.5 and 1 No. for 2Px1.5)
438Outdoor PA System JB for SpeakersIncoming : 12Px2.5 (1 No.)Outgoing : 2Px2.5 (12 Nos.) NPT thread glands : 13 Nos.Plugs : 3 Nos. (1 No. Plug for 12Px2.5 and 2 Nos. for 2Px2.5)
439Indoor PA System JB for SpeakersIncoming : 12Px2.5 (1 No.)Outgoing : 2Px2.5 (12 Nos.) NPT thread glands : 13 Nos.Plugs : 3 Nos. (1 No. Plug for 12Px2.5 and 2 Nos. for 2Px2.5)
440POWER SOCKET OUTLETS
441Supply of various types of power socket outlets and all associated accessories, as per doc. no.TK-1P22A-EL-SPE-0074 (Technical specification for Industrial Lighting & Small Power Panels, Junction Boxes & Welding Receptaclest) and TK-1P22A-EL-SPE-0019 (Technical Specification for Flameproof Lighting & Small Power Panels, Junction Boxes & Welding Receptacles)
442Industrial Power Socket Outlets
443Industrial type, 415V, 63A, TPN & E socket outlet, with die cast Al LM6 enclosure , Type WS1
444Industrial type, 415V, 100A, TPN & E socket outlet, with die cast Al LM6 enclosure , Type WS2
445Power Socket Outlets for Explosive Atmospheres
446For Explosive Atmospheres, 415V, 63A, TPN & E socket outlet, with die cast Al LM6 enclosure, Type WS3 (Ex-d, IIC , T3)
447EARTHING AND LIGHTNING PROTECTION
448EARTHING MATERIAL
449Earthing conductor
450Supply of GI strip / bare copper conductor for earthing
45125 x 6 mm GI strip
45240 x 5 mm GI strip
45350 x 6 mm GI strip
45475 x 10 mm GI strip
455Earth / lightning protection electrodes
456Supply of Earth / lightning protection electrodes along with the associated accessories / material as per 'Installation Details - Earthing', including any additional hardware as per site requirement so as to ensure the completeness of installation work
457Installation Type : E01A :100 mm Dia, 3 m length GI pipe earth electrode for Electrical Safety earth
458Installation Type : E01B : 100 mm Dia, 6 m length GI pipe earth electrode for Instrument clean earth
459Installation Type : E01A : 100 mm Dia, 3 m length GI pipe lightning protection electrode
460Earth buses
461Supply of Earth buses along with the associated accessories (excluding structural steel) as per 'Installation Details - Earthing' and applicable construction documents, including any additional material as per site requirement so as to ensure the completeness of installation work
462Supply of steel support structure / supporting frames for above shall be considered separately in SECTION - F.
463Installation Type : E02A GI earth bus for Electrical safety
464Installation Type : E02B GI earth bus for Electrical safety
465Installation Type : E02A - GI earth bus for instruments
466Installation Type : E02B - GI earth bus for instruments
467Installation Type : E20 - Mounted on cable tray for Electrical
468Installation Type : E20 - Mounted on cable tray for Instrumentation
469Installation Type : E22 - Cu insulated earth bus
470Supply of following Earthing Materials as per Installation Type : E141. 9 DIA G.I. BAR2. SHARP JAW TONG TYPE HEAVY DUTY SPRING CLAMP-100A
471LIGHTNING PROTECTION MATERIAL
472Lightning protection conductor
473Supply of GI strip / bare copper conductor/aluminium/HDGI Round conductor for Lightning protection and associated accessories
474Supply of accessories such as test links, cross connectors, parallel connectors for lightning protection down conductors, epoxy insulator supports and the associated accessories as per 'Installation Details - Lightning Protection' / as indicated in applicable construction documents / as per the site requirement, are considered in running meter length of lightning protection down conductors.
475Installation Type: E16 Roof Conductor (Conductor Size- 25x6mm)
476Installation Type: E16 Down Conductor (Conductor Size- 25x6mm)
477Test Link : E16 : 50x6mm GI Link 150mm Long
478Lightning protection rods / finials
479Supply of Lightning protection rods / finials (lightning arrestors) along with the associated accessories (excluding structural steel) as per 'Installation Details - Lightning Protection' and applicable construction documents, including any additional material as per site requirement so as to ensure the completeness of installation work
480Supply of steel support structure / supporting frames for above shall be considered separately in SECTION - F.
481Installation Type : E24
482Installation Type : E25
483Installation Type : E26
484Installation Type : E27
485STRUCTURAL STEEL
486Supply of structural steelSection wise requirement shall be estimated by CONTRACTOR, as per the applicable construction documents / various applicable 'Installation Details' mentioned in 'SECTIONS - A to E' in this document.Measurement of steel quantity for installation shall be based on actual quantities installed at site without wastage allowance.
487Structural steel (MS)
488Supply of coating material and paint as required for surface preparation and painting of steel shall be as per doc. TP-1ZZZA-PI-SPE-0003 (Technical Specification for Painting) is included in scope.
489Structural steel (Hot deep galvanized GI)
490MISCELLANEOUS ITEMS
491CANOPIES
492Supply of GI / FRP canopies for various equipment and all associated accessories, as per 'ANNEXURE-II to SCC - SCOPE OF SUPPLY - ELECTRICAL'.Site visit as required to confirm the actual dimensions / arrangement of various equipment installed at site, so as to fabricate canopy exactly suitable for the equipment is considered in the scope.Supply of all the Installation Material (including steel supporting frame as required) required as per site requirement is included in the scope.
493Canopies for Motors
494GI canopy complete with louvers backed up by wire mesh
495Upto 3.0 kW
4963.7 kW to 15 kW
49718.5 kW to 37.0 kW
49845.0 kW to 90 kW
499110 kW to160 kW
500GI canopy complete with louvers backed up by wire mesh - HV (6.6kV) Motors
501Above kW to 280 kW
502Above 280 kW to 500 kW
503Above 500 kW to 750 kW
504Above 750 kW to 1200 kW
505Above 1200 kW to 2000 kW
506Above 2000 kW to 5000 kW
507Above 5000 kW to 8000 kW
508GI Canopies omplete with louvers backed up by wire mesh for MV panels (wall / concrete / steel structure mounted) / LCS / Power Socket Outlets /Convenience Socket Outlets
509LDB / ELDB / PDBs
510Local Control Station (LCS)
51120A / 32A Power Socket Outlets in sheet steel enclosure / die cast Al LM6 body
51263A / 100A Power Socket Outlets in sheet steel enclosure / die cast Al LM6 body
513CIVIL WORK
514Anchor fasteners
515Supply of aheavy duty Galvanised steel anchor fasteners for supporting various equipment in brick work / concrete work
516Supply of anchor fasteners indicated below excludes those already considered in various 'Installation Details' mentioned in 'SECTIONS - A to E' in this document.
517Anchor fasteners M8 type x 60mm
518Anchor fasteners M10 type x 75 mm
519Anchor fasteners M12 type x 100 mm
520Supply of certified soft sand of known resistivity (Resistivity of sand shall be between 10,000 – 30,000 ohm.cm. )
521Supply of approved second class bricks of 75 mm thickness in cable trenches for cable protection, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.
522Supply approved Red coloured concrete tiles in cable trenches for cable protectionas per approved drawings, specifications of this tender and directions of Engineer-in-Charge.
523SAFETY ITEMS
524Supply of safety items as per applicable statutory requirements / HSE documents / as indicated in applicable construction documents
525Enameled caution boards for 33 kV.
526Enameled caution boards for 6.6 kV.
527Enameled caution boards for 1.1 kV.
528Enameled Danger plates to be installed in electrical rooms such as transformer bay, switchgear room etc.
5293 ply Lamicoid tag plates of appropriate size for various equipment, with White letters on Black background, as per the site requirement
530Epoxy insulating floor coating (Valency Compound Make - Valency-111 CLASS A or equivalent
53133kV System
5326.6 kV systems -
533upto 1.1 kV systems
534Supply of 1000mm wide Synthetic Insulating mat (as per IS 15652: 2006) including supply of necessary adhesive for following grades (thickness as per voltage withstand requirements) required for maintenance of electrical equipment in substation, including cutting to required shape in running length, including all labour and materials, as per applicable Indian or International standards and CEA Guidelines and as per directions of Engineer-in-Charge
53533kV System
5366.6 kV systems -
537upto 1.1 kV systems
538First aid information chart (for electrical hazards such as Shock treatment): Framed laminated shock treatment chart, conforming to IE rules, in English and local language \\"Assamese\\". Name, address and telephone number of nearest doctor shall be mentioned in it.
539First aid boxes along with required medicines / medical equipment, containing ointments for treatment of electrical burns, conforming to IE rules.
540Wall mounted, Electrical Single Line Diagrams-A0 size\\" for the unit including frame, glass, hardwares, etc.
541Industrial electrical Rubber hand gloves, Class 1 of reputed make
542Rubber hand gloves pairs (1.1 kV grade).
543Rubber hand gloves pairs (6.6 grade).
544Rubber hand gloves pairs (33 kVgrade).
545Discharge rod with earthing facility (upto 6.6 kV grade) with voltage detection
546Discharge rod with earthing facility (Above6.6 kV up to 33kV) with voltage detection
547LOTO with multiple locks (HESP) of reputed make.
548Locks with keys of reputed make
549Supply of following items for Battery area
550Chemical Resistant Apron
551Chemical Resistant Boot Pairs
552Chemical Resistant Hand Gloves Pairs
553Goggles used for Chemical handling
554Electrical Protection suit / ARC FLASH SUIT 12CAL with JACKET, PANT ,GLOVES and FACE SHIELD for 12 Calories
555GENERAL ITEMS
556Supply of following items and all the associated accessories as per 'ANNEXURE-II to SCC - SCOPE OF SUPPLY - ELECTRICAL'.
557Office tables of reputed make
558Office chairs of reputed make
559Full size Cupboard of reputed make, sheet steel enclosure (for documentation)
560Tool Cabinet, Wall Mounted
561Key Cabinet, Wall Mounted
562Tarpaulin (for weather protection of stored electrical equipment)
563Insulated step ladder of reputed make (suitable for indoor work in switchgear rooms)
564Supply of Fire proofing of cables up 3 m length at entry points of both endsincluding all labour and materials required. (Actual area of surface painted shall be measured) _ - (As perIEC 60331) Fire proof paint for cables for 1 hour Fire Rating (CABLE SURFACE AREA WISE)Fire retardant cable coatingHILTI : CP679A / OBO BETTERMAN equivalent product
565Supply of Fire Stop (Fire Sealing) material suitable to withstand for 240 mins including all labour and materials required for sealing the wall opening / conduits fire sealings.Refer annex EW4-6 for details of openings to be sealed
566Supply of Fire Stop (Fire Sealing) material suitable to withstand for 90 mins including all labour and materials required for sealing the wall opening / conduits fire sealings.Refer annex EW4-6 for details of openings to be sealed
567Supply of Weather proofing material HILTI make including all labour and materials required for sealing the wall opening / conduits fire sealings.
568LV Switchgear Components
5696A, 9 kA, DP MCB
57010A, 9 kA, DP MCB
57120 / 32 A, 9 kA, DP MCB
572Terminal Blocks
573up to 2.5 sqmm
574Above 2.5 sq. mm up to 6 sqmm
575Ethernet Switch
576Unmanaged Ethernet switch - Dual Power Supply (110V DC / 230 V AC)No of Ports : 6 X RJ 45 Ethernet Ports + 2 XFO Ports (Multi Mode)Uplink Speed : 1000MBPS /1GBPS The scope includes supply of LIU / Patch Panel with MMFO Patch cords (Length : 5 meter)between Ethernet switch & LIU.
577Unmanaged Ethernet switch - Dual Power Supply (110V DC / 230 V AC)No of Ports : 10 X RJ 45 Ethernet Ports + 2 XFO Ports (Multi Mode)Uplink Speed : 1000MBPS /1GBPS The scope includes supply of LIU / Patch Panel with MMFO Patch cords (Length : 5 meter)between Ethernet switch & LIU.
578TOOLS & TACKLES OF REPUTED MAKEMake shall be approved by Owner / Consultant, all supplied material shall be industrial grade, ISI certified.
579True RMS Digital Multimeter with Display of up to 3 digits of decimal.Make:-Megger,Fluke, Kyoritsu, Hyoki
580Continuity Testers
581Tong Testers Make:-Meco, Megger, Fluke, Kyoritsu, Hyoki
582Phase Sequence Meter
583Tachometers (Non-Contact type)
584Lux Level Meters for illumination check
585Insulation Resistance Testers (Meggers) of 500V, 1000V ratingMake:-Megger,Fluke,kyoritsu, Hyoki
586Insulation Resistance Testers (Meggers) of 2500V & 5000V rating, battery operated-Make:-Megger,Fluke,kyoritsu, Hyoki
587Earth Resistance Testers with all accessories and clamps -Make: -Megger,Fluke,kyoritsu, Hyoki
588GENERAL NOTESThis document shall be read in conjunction with doc. \\"SCOPE OF WORK-ELECTRICAL\\" DOC ID TK-1P22A-EL-SPE-0022.For 'Limit of Variation' in the rates / quantities / total value of work, please refer 'SPECIAL CONDITIONS OF CONTRACT'.CONTRACTOR shall only use 'Released for Construction (RFC)' drawings / documents for execution of work during the Construction phase.Dismantling activities shall be paid at 30% of the unit rates of the respective installation work. Dismantling activities shall only be paid to CONTRACTOR if instructed by OWNER / CONSULTANT, and not for erroneous execution done by CONTRACTOR.All the fixing hardwares such as nuts, bolts, U-bolts, screws, washers & clamps shall be of Stainless Steel (SS304), unless otherwise specified in Installation details and applicable construction documentsCONTRACTOR shall ensure that the rates quoted for execution of electrical works take into account all requirements, services, activities & responsibilities defined as forming part of CONTRACTOR’s scope in the Tender Document / Contract.Special attention shall be given to include the efforts necessary to implement & comply with the relevant safety practices to be followed for the electrical works at the Plant Site, as per the applicable HSE documents.CONTRACTOR should read entire specification to understand in totality the scope of supply and Installation. Every line item for Supplies and Installation should be read along with the respective Installation standard / hook up drawings related to that specific line item to understand the scope of supply and Installation in totality. Any missouts in supply scope in this regard by the CONTRACTOR shall not be entertained.
589EQUIPMENT
590TRANSFORMERS
591Handling, shifting from site-store / yard to the installation location, unpacking, erection, alignment, installation of assemblies / sub-assemblies, assembling and installation of components / devices supplied separately/ loose - as recommended by MANUFACTURER / applicable construction documents, Testing of oil, first filling and first filtration of oil, touch up painting, stenciling with paint on equipment enclosures as required and other associated work so as to ensure the completeness of installation work.Testing and precommissioning activities, commissioning assistance as required by MANUFACTURER's supervisor is included in the scope.Minor civil work such as chipping, grouting for fixing of associated equipment / assemblies and replastering the same as per the site requirement (including the supply of consumable material for the same) is included in the scope. Supply of all fixing hardware as per the site requirement is included in the scope.Supply, Fabrication, surface preparation, painting and installation of steel support of steel support structure / supporting frames as per the site requirement for above shall be considered separately in SECTION - F
592Power transformers (Oil filled)
593TAG : 1U64-SS16-TR-210A & 1U64-SS16-TR-210BRating : 25 / 31.5 MVA, 33 kV / 6.9 kV, ONAN / ONAF, Dyn11 WITH OCTC, 2 winding including PDMS, OMR SystemApprox. Dimensions (LxBxH) : 5730 x 3940 x 4330 mmOil capacity : 7700 ltrs. (6380kg.)Approx. Weight : 36180 kg (including oil)The Transformer Tank may be partially filled with oil at the time of shipment. CONTRACTOR shall completely fill the Tank at site.
594Distribution transformers (Oil filled)
595TAG : 1U64-SS16-TR-331A/B, 332A/B, 333A/B, 334A/BRating : 2000 kVA, 6.6 kV / 433 V, ONAN, Dyn11 WITH OCTCApprox. Dimensions (LxBxH) : 3300 x 2400 x 3500mmOil capacity : 1850 ltrs.Approx. Weight : 7900 kg (including oil)The Transformer Tank may be partially filled with oil at the time of shipment. CONTRACTOR shall completely fill the Tank at site.
596Dry type transformers (Lighting / Heat tracing / Isolation transformers etc.) with all accessories
597TAG : 1U64-SS16-TR-335Rating : 2200 kVA, 6600 V / 433 V, 2 winding, indoor installationApprox. Dimensions (LxBxH) : 3700 X 3100 X 3200 mmApprox. Weight : 6200 Kg Location : Indoor
598TAG : 1U64-SS16-TR-503A/BRating : 300 kVA, 415 V / 433 V, 2 windingApprox. Dimensions (LxBxH) : 1620 X 1675 X 1550 mmApprox. Weight : 1400 KgLocation : Indoor
599TAG : 1U64-SS16-TR-504A/B Rating : 50 kVA, 415 V / 433 V, 2 windingApprox. Dimensions (LxBxH) : 1680X 1000 X 1000 mmApprox. Weight : 460 kgLocation : Indoor
600Filtration of transformer oil by filter machine provided by the contractor for improving the insulation strength of oil to the required strength, including all labour and materials, specifications of this tender and directions of Site Engineer-in-Charge. (Excluding the supply of oil). but including required BDV oil testingCost of first filteration shall be included in installation cost of Transformer. This rate shall be applicable only in event of addtional filteration requirement due to site conditions after completion of first flteration
601BUSDUCTS
602Handling, shifting from site-store / yard to the installation location, unpacking, erection, alignment, assembling and installation of shipping sections / assemblies / sub-assemblies, assembling and installation of components including bends and risers / devices supplied separately - as recommended by MANUFACTURER / applicable construction documents, alignment for appropriate termination of busbars at both the ends, Installation of bends, fixing of flexible joints, stenciling with paint on equipment enclosures as required and other associated work so as to ensure the completeness of installation workTesting, precommissioning and commissioning activities are included in the scopeMinor civil work such as chipping and modifications in the wall cutout, as required, for making busduct wall opening suitable for busduct entry etc., replastering and making area good as per the site requirement (including the supply of consumable material for the same), sealing with fire proofing compound, is included in the scope. Supply of all fixing hardware as per the site requirement is included in the scope.Fabrication and installation of steel support structure / supporting frames (inside and outside the substation building) for equipment as per the site requirement, is considered separately in SECTION - F.
6036.6 kV, 3150 A, 40kA for 1 sec, Aluminium busbar Construction : Sheet steel / Aluminium enclosure, Phase SegregatedFrom : Transformer secondary to Switchgear IncomersApprox. Weight : 340 kg / m
604415 V, 3200 A, 50kA for 1 sec, Aluminium busbarConstruction : Sandwich type, Material of enclosure : Galvanized steel / AluminiumFrom : Transformer secondary to Switchgear Incomer Approx. Weight : 50 kg / m
605NEUTRAL GROUNDING RESISTOR (NGR)
606Handling, shifting from site-store / yard to the installation location, unpacking, erection, alignment, assembling and installation of equipment and accessories, assembling and installation of components / devices supplied separately - as recommended by MANUFACTURER / applicable construction documents, stenciling with paint on equipment enclosures as required and other associated work so as to ensure the completeness of installation work.Testing, precommissioning and commissioning activities are included in the scope.Minor civil work such as chipping, grouting for fixing of equipment / assemblies and replastering the same as per the site requirement (including the supply of consumable material for the same) is included in the scope. Supply of all fixing hardware as per the site requirement is included in the scope.Fabrication and installation of steel support structure / supporting frames for equipment as per the site requirement, is considered separately in SECTION - F.
607TAG : 1U64-SS16-NGR-210A/BRating : 3.8 kV, 400 A for 30 secApprox. Dimensions (LxBxH) : 1450 x 890 x 950 mmApprox. Weight : 450 kgs
608HV SWITCHBOARDS - 6.6kV Switchboards, HV PFIC Panels, HV VFD / Soft Starter panels etcHandling, shifting from site-store / yard to the installation location, unpacking, erection, alignment, assembling and installation of various shipping sections / assemblies, assembling and installation of components / devices supplied separately - as recommended by MANUFACTURER / applicable construction documents, interpanel wiring, stenciling with paint on equipment enclosures as required, and other associated work so as to ensure the completeness of installation work.Installation of condition monitoring sensors, modules etc. as applicable is included in the scope.Testing and precommissioning activities, commissioning assistance as required by MANUFACTURER's supervisor is included in the scope. Minor civil work such as chipping, grouting for fixing of equipment as per the site requirement and replastering the same (including the supply of consumable material for the same) is included in the scope. Fabrication and installation of steel support structure / supporting frames for equipment as per the site requirement, is considered separately in SECTION - F.Supply of all fixing hardware as per the site requirement is included in the scope.
609TAG : 1U64-SS16-AIS-210Rating : 6.6 kV, 3150 A, 40kA for 1 sec.Construction : Floor mounting, single frontNos. of vertical sections : 72Approx. Dimensions (LxBxH)mm : 600/800/1000 x 1950/2250/2500 x 2500 mm (per vertical section)Approx. Weight : 800 / 1200 kg (per vertical section) Switchboard Arrangement : Double Line,front to front The scope includes installation of interconnecting busduct between 2 lines of switchboard & Arc duct / arc absorber with wall frame assembly as applicable.
610Unit rate for additional / deletion of Vertical section for Item as per sr. no. A/4.1
611TAG : 1U64-KAM-2781-VCB (6.6 kV Output VCB Panel)Rating : 6.6 kV, 800 A, 40kA for 1 sec.Nos. of vertical sections : 3Approx. Dimensions (LxBxH)mm : 600 x 1570/1970 x 2500mm (per vertical section)Approx. Weight : 700 kg (per vertical section)
612TAG : 1U64-KAM-2782A/B-VCB (6.6 kV Output VCB Panel)Rating : 6.6 kV, 1250 A, 40kA for 1 sec.Nos. of vertical sections : 2Approx. Dimensions (LxBxH)mm : 600 x 1570 x 2200mm (per vertical section)Approx. Weight : 700 kg (per vertical section)
613TAG : 1U64-SS16-CAP-210A/B (PFIC Panel, indoor type)Rating : 6.6 kV, 3750 kVAr Nos. of vertical sections : 6Approx. Dimensions (LxBxH)mm : 1200/1400 x 2400 x 2475 mm (per vertical section)Approx. Dimensions (LxBxH)mm : 9400 x 2400 x 2475 mm (overall)Approx. Weight : 1800 kg (per vertical section)
614TAG : 1P23-KAM-2781-VFD1 and 1P23-KAM-2781-VFD1 (HV VFD Panel)Rating : 6.6 kV, 2600 kW Approx. Dimensions (LxBxH) : 6000 x 1500/1200 x 2800 mm Approx. Weight : 8800 kgs Mounting : On floorScope also includes installation of -common PLC Panel with approx. dimensions (L X B XH) : 2000 mm X 600 mm X 2315 mm, Approx. weight : 600 kgsCommon CMS Panel with approx. dimensions (L X B XH) : 700 mm X 350 mm X 700 mm, Approx. weight : 70 kgs
615TAG : 1P23-KAM-2782A/B-VFD (Soft Starter Panel)Rating : 6.6 kV, 2600 kW Approx. Dimensions (LxBxH) : 6300 x 1100 x 2750 mm Approx. Weight : 9900 kgs Mounting : On floorApprox. weight : 9900 kgs
616LV / MV SWITCHBOARDS (FLOOR MOUNTED)
617Handling, shifting from site-store / yard to the installation location, unpacking, erection, alignment, assembling and installation of various shipping sections / assemblies, assembling and installation of components / devices supplied separately - as recommended by MANUFACTURER / applicable construction documents, interpanel wiring, stenciling with paint on equipment enclosures as required, and other associated work so as to ensure the completeness of installation work.Installation of condition monitoring sensors, modules etc. as applicable is included in the scope.Testing and precommissioning activities, commissioning assistance as required by MANUFACTURER's supervisor is included in the scope.Minor civil work such as chipping, grouting for fixing of equipment as per the site requirement and replastering the same (including the supply of consumable material for the same) is included in the scope.Fabrication and installation of steel support structure / supporting frames for equipment as per the site requirement, is considered separately in SECTION - F. Supply of all fixing hardware as per the site requirement is included in the scope.
618TAG : 1U64-SS16-PMCC-331Rating : 415 V, 3200 A, 50 kA for 1 sec.Construction : Floor mounting, single frontNos. of Shipping sections : ~ 10Approx. Maximum Dimensions (LxBxH)mm : 1900 x 1750 x 2630mm (per shipping section)Approx. Dimensions (LxBxH)mm : 15000 x 950 / 1450 / 1750 x 2630 mm (overall)Approx. Maximum Weight : 2100 KGS.(per shipping section ) Approx. Weight : 16000 KGS.(overall )
619TAG : 1U64-SS16-PMCC-332Rating : 415 V, 3200 A, 50 kA for 1 sec.Construction : Floor mounting, single frontNos. of Shipping sections : ~ 10Approx. Maximum Dimensions (LxBxH)mm : 1650 x 1750 x 2630mm (per shipping section)Approx. Dimensions (LxBxH)mm : 14000 x 950 / 1450 / 1750 x 2630 mm (overall)Approx. Maximum Weight : 1900 KGS.(per shipping section ) Approx. Weight : 14500 KGS.(overall )
620TAG : 1U64-SS16-PMCC-333Rating : 415 V, 3200 A, 50 kA for 1 sec.Construction : Floor mounting, single frontNos. of Shipping sections : ~ 9Approx. Maximum Dimensions (LxBxH)mm : 1900 x 1750 x 2630mm (per shipping section)Approx. Dimensions (LxBxH)mm : 14500 x 950 / 1450 / 1750 x 2630 mm (overall)Approx. Maximum Weight : 2100 KGS.(per shipping section ) Approx. Weight : 17000 KGS.(overall )
621TAG : 1U64-SS16-EPMCC-334Rating : 415 V, 3200 A, 50 kA for 1 sec.Construction : Floor mounting, single frontNos. of Shipping sections : ~ 13Approx. Maximum Dimensions (LxBxH)mm : 1650 x 1750 x 2630mm (per shipping section)Approx. Dimensions (LxBxH)mm : 19500 x 950 / 1450 / 1750 x 2630 mm (overall)Approx. Maximum Weight : 2100 KGS.(per shipping section ) Approx. Weight : 21500 KGS.(overall )
622TAG : 1U64-SS16-MCC-446Rating : 415 V, 800 A, 50 kA for 1 sec.Construction : Floor mounting, double frontNos. of Shipping sections : ~ 4Approx. Maximum Dimensions (LxBxH)mm : 2450 x 1250 x 2600mm (per shipping section)Approx. Dimensions (LxBxH)mm : 7250 x 950 / 1250 x 2600 mm (overall)Approx. Maximum Weight : 2100 KGS.(per shipping section ) Approx. Weight : 6500 KGS.(overall )
623TAG : 1U64-SS16-MCC-447Rating : 415 V, 800 A, 50 kA for 1 sec.Construction : Floor mounting, double frontNos. of Shipping sections : ~ 7Approx. Maximum Dimensions (LxBxH)mm : 2450 x 1250 x 2600mm (per shipping section)Approx. Dimensions (LxBxH)mm : 11100 x 950 / 1250 x 2600 mm (overall)Approx. Maximum Weight : 2100 KGS.(per shipping section ) Approx. Weight : 10000 KGS.(overall )
624TAG : 1U64-SS16-MCC-448Rating : 415 V, 800 A, 50 kA for 1 sec.Construction : Floor mounting, double frontNos. of Shipping sections : ~ 12Approx. Maximum Dimensions (LxBxH)mm : 2450 x 1250 x 2600mm (per shipping section)Approx. Dimensions (LxBxH)mm : 22000 x 950 / 1250 x 2600 mm (overall)Approx. Maximum Weight : 2100 KGS.(per shipping section ) Approx. Weight : 19000 KGS.(overall )
625TAG : 1U64-SS16-MCC-450Rating : 415 V, 800 A, 50 kA for 1 sec.Construction : Floor mounting, double frontNos. of Shipping sections : ~ 4Approx. Maximum Dimensions (LxBxH)mm : 2450 x 1250 x 2600mm (per shipping section)Approx. Dimensions (LxBxH)mm : 8000 x 950 / 1250 x 2600 mm (overall)Approx. Maximum Weight : 2100 KGS.(per shipping section ) Approx. Weight : 7200 KGS.(overall )
626TAG : 1U64-SS16-MCC-451Rating : 415 V, 800 A, 50 kA for 1 sec.Construction : Floor mounting, double frontNos. of Shipping sections : ~ 5Approx. Maximum Dimensions (LxBxH)mm : 2450 x 1250 x 2600mm (per shipping section)Approx. Dimensions (LxBxH)mm : 8000 x 950 / 1250 x 2600 mm (overall)Approx. Maximum Weight : 2100 KGS.(per shipping section ) Approx. Weight : 7200 KGS.(overall )
627TAG : 1U64-SS16-EMCC-452Rating : 415 V, 800 A, 50 kA for 1 sec.Construction : Floor mounting, double frontNos. of Shipping sections : ~ 7Approx. Maximum Dimensions (LxBxH)mm : 2450 x 1250 x 2600mm (per shipping section)Approx. Dimensions (LxBxH)mm : 9500 x 950 / 1250 x 2600 mm (overall)Approx. Maximum Weight : 2100 KGS.(per shipping section ) Approx. Weight : 8500 KGS.(overall )
628TAG : 1U64-SS16-ASB-504Rating : 415 V, 800 A, 50 kA for 1 sec.Construction : Floor mounting, double frontNos. of vertical sections : ~12Approx. Dimensions (LxBxH)mm : 800/1050 x 1750/1450 x 2530 mm (per vertical section) Approx. Weight : 900 KGS.(per vertical section )
629TAG : 1U64-SS16-MLDB-503Rating : 415 V, 800 A, 20 kA for 1 sec.Construction : Floor mounting, single frontNos. of vertical sections : ~12Approx. Dimensions (LxBxH)mm : 800/1050 x 1450/650 x 2430 mm (per vertical section) Approx. Weight : 900 KGS.(per vertical section )
630TAG : 1U64-SS16-EMLDB-504Rating : 415 V, 100 A, 10 kA for 1 sec.Construction : Floor mounting, single frontApprox. Overall Dimensions (LxBxH)mm : 6000 x 650 x 2430 mm Approx. Weight : 500 kg
631MISCELLANEOUS Panels / Items(WALL / CONCRETE / STEEL STRUCTURE MOUNTED)(Industrial / For Explosive Atmospheres)
632Installation of industrial weather proof / flame proof Lighting, Power panels on steel structures/concrete coloumn/wall etc, including supply & making of concrete foundations if required for supports, minor civil works if any, and installation of canopies. This also includes supply of necessary hardware, cement, sand , touch up painting, stenciling , Including Lifting & Transportation from storage area to the place of installation with contractor's own lifting and transportation arrangement, unpacking, assembly, including all labour and materials complete as per approved drawings,Installation of LV panels (wall / concrete / steel structure mounted) shall be as per 'Installation Details - Power' and applicable construction documentsSupply of Installation materials (excluding structure steel), including any additional material as per site requirement so as to ensure the completeness of installation work is included in the scopeTesting, precommissioning and commissioning activities are included in the scope.Minor civil work such as chipping, grouting for fixing of equipment and replastering the same as per the site requirement (including the supply of consumable material for the same) is included in the scope.Fabrication and installation of steel support structure / supporting frames for equipment as per the site requirement, is considered separately in SECTION - F. Supply of all fixing hardware as per the site requirement is included in the scope.Weights indicated below are euqipment/ item weights to be installed.
633Lighting / Power PanelsLDB / ELDB / DL LDB / PDB (6way / 9way / 12way / 15way / 18way/ 24 Way)
634Local Control Panel / Local Starter Panel / Local Isolators / Hydro jetting PDB
635Weight of the Unit up to 20 kg
636Weight of the Unit above 20 up to 100 kg
637Weight of the Unit above 100 upto 200 kg.
638Weight of the Unit above 200 upto 300 kg.
639BATTERY CHARGER (DC UPS) AND BATTERY
640Handling, shifting from site-store / yard to the installation location, unpacking, erection, alignment, assembling and installation of equipment / assemblies, assembling and installation of components / devices supplied separately - as recommended by MANUFACTURER / applicable construction documents, stenciling with paint on equipment enclosures as required and other associated work so as to ensure the completeness of installation work.Assembly of battery rack, placement of battery cells on the support rack, electrolyte filling and associated work as recommended by MANUFACTURER is included in the scope.Installation of battery MCCB with enclosure at the location indicated in the applicable layouts is included in the scope.Installation of Battery monitoring system as applicable is included in the scope. Testing and precommissioning activities, commissioning assistance as required by MANUFACTURER's supervisor is included in the scope. First charge, Discharge and again charging of battery bank is included in scope.Minor civil work such as chipping, grouting for fixing of equipment / assemblies and replastering the same as per the site requirement (including the supply of consumable material for the same) is included in the scope.Fabrication and installation of steel support structure / supporting frames for various equipment / assemblies as per the site requirement, is considered separately in SECTION - F.Supply of all fixing hardware as per the site requirement is included in the scope.
641TAG : 1U64-SS16-ECH-503 (For Switchgear Control)
642Battery charger (Dual redudant)Rating : 110 VDC, 160 A, Battery charger with seperate DCDB Construction : Non Compartmentalised, Single / Double frontApprox. Dimensions (LxBxH) : 2200 x 800 x 2000 mm Approx. Weight : 600 kgs (Overall) Mounting : On Floor
643Battery bank : 1U64-SS16-BAT-503A/B Battery type : Ni-CdNo, of cells : 95Rating : 300 AHMounting : floor mounted battery rack, multi-tier
644DCDB : 1U64-SS16-DCDB-503-1 No.Rating : 110 VDC, 160 AConstruction : Compartmentalised, Single frontApprox. Dimensions (LxBxH) : 6500 x 450 x 2200 mmApprox. Weight : 850 kgs (Overall)Mounting : On Floor
645Battery Isolator (MCCB) - 2 Nos.Enclosure : FlameproofMounting : on wall
646Cell Booster (Portable type) - 2 Nos.Approx. Dimensions (LxBxH) : 600 x 600 x 500 mm
647TAG : 1U64-SS16-ECH-504 (For DC Critical Lighting)
648Battery charger (Single)Rating : 110 VDC, 75 A, Battery charger with seperate DCDBConstruction : Non Compartmentalised, Single / Double frontApprox. Dimensions (LxBxH) : 600 x 600 x 1500 mmApprox. Weight : 200 kgs (Overall) Mounting : On Floor
649Battery bank : 1U64-SS16-BAT-504Battery type : Ni-CdNo, of cells : 95Rating : 140 AHMounting : floor mounted battery rack, Two-tier
650DCDB : 1U64-SS16-DCDB-504- 1 No.Rating : 110 VDC, 75 AConstruction : Compartmentalised, Single frontApprox. Dimensions (LxBxH) : 1200 x 450 x 1600 mmApprox. Weight : 150 kgs (Overall)Mounting : On Floor
651Battery Isolator (MCCB)-1 NosEnclosure : FlameproofMounting : on wall
652Cell Booster (Portable type) - 2 Nos.Approx. Dimensions (LxBxH) : 600 x 600 x 500 mm
653AC UPS AND BATTERY
654Handling, shifting from site-store / yard to the installation location, unpacking, erection, alignment, assembling and installation of equipment / assemblies, assembling and installation of components / devices supplied separately - as recommended by MANUFACTURER / applicable construction documents, stenciling with paint on equipment enclosures as required and other associated work so as to ensure the completeness of installation workAssembly of battery rack, placement of battery cells on the support rack, electrolyte filling and associated work as recommended by MANUFACTURER is included in the scope.Installation of battery MCCB with enclosure at the location indicated in the applicable layouts is included in the scope.Installation of Battery monitoring system as applicable is included in the scope. Testing and precommissioning activities, commissioning assistance as required by MANUFACTURER's supervisor is included in the scope. First charge, Discharge and again charging of battery bank is included in scope.Minor civil work such as chipping, grouting for fixing of equipment / assemblies and replastering the same as per the site requirement (including the supply of consumable material for the same) is included in the scope. Fabrication and installation of steel support structure / supporting frames for various equipment / assemblies as per the site requirement, is considered separately in SECTION - F.Supply of all fixing hardware as per the site requirement is included in the scope.
655TAG : 1U64-SRR6-UPS-501
656UPS Rating : 115 VAC, 200 kVA, Parallel redudant UPS with common bypass and separate ACDBConstruction : Non Compartmentalised, Single / Double frontApprox. Dimensions (LxBxH) : 8000 x 1200/1000 x 2100 mm (Overall)Mounting : On False floor supported with structural steel base frame
657Battery bank : 2 setsBattery type : Ni-CdNo, of cells (Per set) : ~ 375Rating of cell : ~ 650 AHMounting : floor mounted battery rack, multi-tier
658ACDB : 1 No.Rating : 115 V AC, 2000 AConstruction : Compartmentalised, Single / Double frontApprox. Dimensions (LxBxH) : 13000 x 850 x 2200 mmMounting : On False floor supported with structural steel base frame
659Battery Isolator (MCCB)-2 NosEnclosure : FlameproofMounting : on wall / Floor
660Cell Booster (Portable type) - 1 Nos.Approx. Dimensions (LxBxH) : 700 x 700 x 600 mm
661MV (415V) VARIABLE FREQUENCY DRIVES, THYRISTORIZED HEATER CONTROL PANELS, EXCITATION CONTROL PANELS etc.
662Handling, shifting from site-store / yard to the installation location, unpacking, erection, alignment, assembling and installation of equipment and accessories, assembling and installation of components / devices supplied separately - as recommended by MANUFACTURER / applicable construction documents, stenciling with paint on equipment enclosures as required and other associated work so as to ensure the completeness of installation work. Testing and precommissioning activities, commissioning assistance as required by MANUFACTURER's supervisor is included in the scope. Minor civil work such as chipping, grouting for fixing of equipment / assemblies and replastering the same as per the site requirement (including the supply of consumable material for the same) is included in the scope. Fabrication and installation of steel support structure / supporting frames for equipment / accessories as per the site requirement, is considered separately in SECTION - F.Supply of all fixing hardware as per the site requirement is included in the scope.
663TAG : 1P24-EEH-0981Rating : 415V, 1746 kWNo of shipping sections : 6Approx. Maximum Dimensions (LxBxH) : 2800 x 1200 x 2250 mm (per shipping section)Approx. Dimensions (LxBxH) : 12000 x 1000 / 1200 x 2250 mm (overall)Approx. Weight : 8000 kgs (overall)Mounting : On floor
664TAG : 1P24-EEH-0882Rating : 415V, 103 kWApprox. Dimensions (LxBxH) : 1300 x 600 x 2050 mm Approx. Weight : 1000 kgs (overall)Mounting : On floor
665TAG : 1P23-EEH-6383Rating : 415V, 40 kWApprox. Dimensions (LxBxH) : 900 x 500 x 2225 mm Approx. Weight : 700 kgs (overall)Mounting : On floor
666TAG : 1P23-EEH-6382Rating : 415V, 37 kWApprox. Dimensions (LxBxH) : 900 x 500 x 2225 mm Approx. Weight : 700 kgs (overall)Mounting : On floor
667TAG : 1P23-EEH-6381Rating : 415V, 425 kWApprox. Dimensions (LxBxH) : 2100 x 1000 x 2375 mm Approx. Weight : 1600 kgs (overall)Mounting : On floor
668TAG : 1P23-EEH-0882Rating : 415V, 302 kWApprox. Dimensions (LxBxH) : 1800 x 1000 x 2375 mm Approx. Weight : 1500 kgs (overall)Mounting : On floor
669TAG : 1P23-EEH-6385Rating : 415V, 302 kWApprox. Dimensions (LxBxH) : 1000 x 250 x 600 mm Approx. Weight : 250 kgs (overall)Mounting : On wall
670TAG : 1P23-KAM-2782AB-SYNC.(Excitation Panels for H2 Rich Gas Compressor Motor)Construction : Floor mounting, single frontApprox. Overall Dimensions (LxBxH)mm : 1650 x 750 x 2265 mm Approx. Weight : 1000 kgMounting : On floor
671TAG : 1P23-PM-8801A/B-VFD, 1P22-PM-3902A/B-VFD,1P22-PM-4001A/B-VFD Rating : 415V, up to 5.5 kWApprox. Dimensions (LxBxH) : 800 x 600 x 2000 mm Approx. Weight : 500 kgs (overall)Mounting : On floor
672TAG : 1P24-EAM-0953A-VFD, 1P24-EAM-2451A/B-VFD , 1P23-EAM-2651A/B/C-VFD Rating : 415V, Above 5.5 kW, up to 15 kWApprox. Dimensions (LxBxH) : 1000 x 600 x 2000 mm Approx. Weight : 700 kgs (overall)Mounting : On floor
673TAG : Various (VFD Panels)Rating : 415V, Above 15 kW, up to 30 kWApprox. Dimensions (LxBxH) : 1000 x 600 x 2000 mm Approx. Weight : 800 kgs (overall)Mounting : On floor
674INDUCTION MOTORS AND CANOPIESAlignment as required for the accessories such as terminal box, assembling and installation of components / devices supplied separately as recommended by MANUFACTURER / applicable construction documents, stenciling with paint on equipment enclosures as required and other associated work so as to ensure the completeness of installation work.Checking of all interface connections, change of grease in bearings, wherever required, including supply of approved type of grease, no load/full load running of motor, including all labour and materials, as per specifications of this tender and directions of Site Engineer-in-Charge.Testing, precommissioning and commissioning activities are included in the scope.
675MV (415V) Motors
676Upto 3.0 kW
6773.7 kW to 15 kW
67818.5 kW to 37.0 kW
67945.0 kW to 90 kW
680110 kW to160 kW
681Above 160 kW up to 315 kW
682HV (6.6 kV) Motors
683Above 160 kW up to 400 kW
684Above 400 kW up to 800 kW
685Above 800 kW up to 1200 kW
686Above 1200 kW up to 1500 kW
687Above 1500 kW up to 3000 kW
688Above 3000 kW up to 7500 kW
689Canopies
690Handling, shifting from site-store / yard to the installation location, unpacking, erection, alignment, assembling and installation of canopy for the motor - as per applicable construction documents, stenciling with paint on equipment enclosures as required and other associated work so as to ensure the completeness of installation work, minor modifications (cutting, drilling etc.) in the canopy fitting arrangemet if required.Supply of all fixing hardware as per the site requirement is included in the scope.
691MV (415V) Motors
692Upto 3.0 kW
6933.7 kW to 15 kW
69418.5 kW to 37.0 kW
69545.0 kW to 90 kW
696110 kW to160 kW
697Above 160 kW up to 315 kW
698HV (6.6 kV) Motors
699Above 160 kW up to 400 kW
700Above 400 kW up to 800 kW
701Above 800 kW up to 1200 kW
702Above 1200 kW up to 1500 kW
703Above 1500 kW up to 3000 kW
704Above 3000 kW up to 7500 kW
705MV (415V) Electric Heaters : Testing and commissioning of Electric Heaters of following ratings and checking of all interface connections including Electric Heater Junction box installation along with associated cables, terminations. Providing assistance for successful commissioning of heaters, laying and termination of braided cables to heater terminal box (as applicable), testing and commissioning works, including all labour and materials, as per approved drawings, specifications of this tender and directions of Site Engineer-in-Charge.
706up to 5.5 kW
707Above 5.5 kW but upto 22 kW.
708Above 22 kW but upto 45 kW
709Above 45 kW but upto 160 kW
710Above 160 kW but upto 450 kW.
711Above 1000 kW but upto 1750 kW.
712LOCAL CONTROL STATIONS (LCS)
713Handling, shifting from site-store / yard to the installation location, unpacking, erection, alignment, assembling and installation of equipment, assembling and installation of components / devices supplied separately - as recommended by MANUFACTURER / applicable construction documents, stenciling with paint on equipment enclosures as required and other associated work so as to ensure the completeness of installation work.Testing, precommissioning and commissioning activities are included in the scope.Supply of installation materials (excluding structure steel) as per installation details-power and applicable construction documents are included in the scope.Fabrication and installation of steel support structure / supporting frames for equipment as per the site requirement, is considered separately in SECTION - F.
714Industrial/ Explosive Atmospheres type LCS (wall / concrete / steel structure mounted)
715INSTALLATION OF SWITCH-BOARDS, RELAY AND CONTROL PANELS, ANNUNCIATION PANELS, UPS SYSTEM, BATTERY CHARGERS, DISTRIBUTION BOARDS, CUBICLES WITH ELECTRICAL EQUIPMENT, VSD/ Softstarter PANELS, RTCC panles, MISC .ELECTRICAL PANELS, ETCSwitchboards / panels indicated below excludes items already considered in sr. no. A/5 to A/9 above
716Handling, shifting from site-store / yard to the installation location, unpacking, erection, alignment, assembling and installation of various shipping sections / assemblies, assembling and installation of components / devices supplied separately - as recommended by MANUFACTURER / applicable construction documents, interpanel wiring, stenciling with paint on equipment enclosures as required and other associated work so as to ensure the completeness of installation work.Testing, precommissioning and commissioning activities are included in the scope.Minor civil work such as chipping, grouting for fixing of equipment and replastering the same as per the site requirement (including the supply of consumable material for the same) is included in the scope. Supply of all fixing hardware as per the site requirement is included in the scope.Fabrication and installation of steel support structure / supporting frames for various equipment/ assmblies as per the site requirement, is considered separately in SECTION - F.Supply of all fixing hardware as per the site requirement is included in the scope.
717Weight of the Unit above 100 upto 500 kg.
718Weight of the Unit above 500 upto 1000 kg.
719Weight of the Unit above 1000 upto 1500 kg.
720Weight of the Unit above 1500 upto 3000 kg.
721Weight of the Unit above 3000 upto 5000 kg.
722ELECTRICAL HEAT TRACING SYSTEM
723Installation of Heat Tracing System comprising Power Distribution Board-cum-Control Panel, Heat Tracers and Accessories (Connector, Junction Box, fastening material, etc.), Temp. sensing elements, Thermostats, etc. as per Specification (Doc no. TK-1P22A-EL-SPE-0031)Testing, precommissioning and commissioning activities are included in the scope.Supply of installation materials, fixing hardware etc as per Installation details and applicable construction documents are included in the scope
724CABLE / WIRE LAYING, TERMINATION AND CABLE ROUTING SYSTEMS
725CABLE LAYING
726Handling, shifting of cable drums from site-store / yard to the installation location, unpacking, laying of cables / wires in cable trays (either located above ground or inside RCC cable trenches) / directly buried underground / in sand filled cable trenches (trench constructed by others) / in culverts, duct banks/ through above ground conduits (PVC / GI) clamped on wall or structure or through floor conduits (excluding lighting circuit cables, from LDB / ELDB onwards upto the lighting fixtures) - as recommended by MANUFACTURER / applicable construction documents and other associated work so as to ensure the completeness of installation work. Job also includes return of unused cable/drums to the Owner's store & removal of empty drum/ scrap cables to Owner's Scrap Yard.Testing, precommissioning and commissioning activities are included in the scope. Supply and installation of certified trefoil clamps of non-magnetic materia for 1 core cables, spacer bars and saddles, dressing of cables using Stainless Steel cable ties, cable tags(RFID tags) and ferrules (including all fixing hardware) as per the site requirement are included in the scope.The motorized winch required for cable pulling shall be arrange by contractor and no separate payment for the same will be madeMinor civil work such as chipping / drilling of through-holes / cutouts in floor / walls, replastering and making area good after work done, providing sleeves during the cable laying as per the site requirement and replastering the same (including the supply of consumable material for the same) is included in the scope. Supply and Installation of cable route markers with warning tapes (as applicable) shall be as per 'Installation Details - Power' and applicable construction documents is included in the scope
727HV CABLES
728Cables with OD above 40 mm but upto 60 mm.
729Cables with OD above 60 mm but upto 80 mm.
730LV Power Cables Aluminium condutor cables
731Cables with OD upto 20 mm.
732Cables with OD above 20 mm but upto 30 mm.
733Cables with OD above 30 mm but upto 40 mm.
734Cables with OD above 40 mm but upto 50 mm.
735Cables with OD above 50 mm but upto 60 mm.
736Cables with OD above 60 mm but upto 80 mm.
737Cables with OD above 80 mm but upto 100 mm.
738Cables with OD above 100 mm but upto 120 mm.
739LV Power/ Control/ Signal / Fire alram / Communication / Telephone etc - Copper condutor cables
740Cables with OD upto 20 mm.
741Cables with OD above 20 mm but upto 30 mm.
742Cables with OD above 30 mm but upto 40 mm.
743Cables with OD above 40 mm but upto 50 mm.
744Cables with OD above 50 mm but upto 60 mm.
745EARTHING CABLES (laid above ground/ Undergorund)1100V Al / Cu conductor, PVC insulated, unarmoured earthing cables :- Laying and termination of earthing cables including supply of lug.laying,clamping and connecting individual equipment to the earthstrip or earth plate with following sizes of Cables including supply of required lugs, all hardware for connections, Including all labour and materails, as per approved drawings, specifications of this tender and directions of Engineer-in-charge
7461 C x 6 sq.mm Cu Stranded, PVC insulated Green/Yellow cable
7471 C x 16 sq.mm Cu Stranded, PVC insulated Green/Yellow cable
7481 C x 25 sq.mm Cu Stranded, PVC insulated Green/Yellow cable
7491 C x 50 sq.mm Cu Stranded, PVC insulated Green/Yellow cable
7501 C x 95 sq.mm Cu Stranded, PVC insulated Green/Yellow cable
7511 C x 25 sq.mm Al Stranded, PVC insulated Green/Yellow cable
7521 C x 35 sq.mm Al Stranded, PVC insulated Green/Yellow cable
7531 C x 50 sq.mm Al Stranded, PVC insulated Green/Yellow cable
7541 C x 70 sq.mm Al Stranded, PVC insulated Green/Yellow cable
7551 C x 120 sq.mm Al Stranded, PVC insulated Green/Yellow cable
756GI Wire ropes
757Laying,clamping and connecting individual equipment to the earthstrip or earth plate with following sizes of G.I wire / G.I wire rope, including supply of required lugs, conductors, all hardware for connections, Including all labour and materails, as per approved drawings, specifications of this tender and directions of Engineer-in-charge
7588 SWG Solid GI wire
75910 mm (3/8\\") Dia. flexible GI wire rope
76016 mm (5/8\\") Dia. flexible GI wire rope
761FIBRE OPTIC CABLES : \\"LAYING OF FIBRE OPTIC CABLE:The job includes collection and transportation of all required material from store to work site, laying of FO cable of various sizes along with HDPE conduits inclusive of supply of HDPE conduits, cutting of the cable as per actual measurement/ cableschedule, tagging at definite span length, dressing & clamping, providing identification tags at both ends, as required and complete the job in all respects as per specification, drawings and instructions of Engineer In-ChargeHDPE conduit shall be as per IS-4984 or as per equivalent IEC code. The outer sheath colour of HDPE conduits shall be orange with black for the fittings throughout the fibre optic cable run.
762Fibre Optic Cable - up to 8 Fibre
763Fibre Optic Cable - 12 Fibre
764Fibre Optic Cable - 24 Fibre
765FLEXIBLE CONDUCTOR CABLES
766650V / 1100V (Uo / U) voltage grade, Multistranded Cu conductor, PVC insulated, flexible cable
767Cables with OD upto 20 mm.
768Cables with OD above 20 mm but upto 30 mm.
769Special cables
770Silicon Insulated Flexible cable / Uninyvin cables
771Cables with OD upto 20 mm.
772Cables with OD above 20 mm up to 40 mm
773CAT 6A Cable
774MODBUS SERIAL RS485
775CABLE GLANDING AND TERMINATION (HV)(Industrial / For Explosive Atmospheres)
776Handling, shifting from site-store / yard to the installation location, unpacking, erection, alignment, assembly and installation of HV cable termination kit and cable glands with PVC hoods, installation of components supplied separately - as recommended by MANUFACTURER / applicable construction documents, installation of tinned copper lug, drilling and treading of gland plate, termination of cable at designated location and other associated work so as to ensure the completeness of installation work.
777Cable termination shall be carried out by experienced, competent & certified personnel from the termination kit MANUFACTURER / installation CONTRACTOR.
778Glanding and Termination of 6.6 / 6.6 kV (UE) voltage grade, Al / Cu conductor, XLPE insulated, screened, armoured power cable
7793C x 240 sq.mm A2XCEFY
7801C x 630 sq.mm A2XCEFY
781HV Cable termination kit Separable Connector type (suitable for indoor installation) 6.6kV (UE) HV cables grade, Al conductor, XLPE insulated, screened, armoured power cable. Motor cable TB is suitable for Elastimold Separable connector. The Separable connectors will be supplied by motor manufacturer and will be free issue to the contractor. Contractor to supply THREE CORE HEAT SHRINKABLE BREAKOUT KIT and carry out the complete installation of the separable connector kit.
7823C x 240 sq.mm
783Glanding and Termination of 33 / 33 kV (Uo / U)grade, Al conductor, XLPE insulated, screened, armoured power cable
7841C x 630 sq.mm A2XCEWaY
785CABLE GLANDING AND TERMINATION (MV)(Industrial / For Explosive Atmospheres)
786Handling, shifting from site-store / yard to the installation location, unpacking, erection, alignment, assembly and installation of cable glands (industrial / For Explosive Atmospheres type) with PVC hoods, installation of components supplied separately - as recommended by MANUFACTURER / applicable construction documents, installation of lug, drilling and treading of gland plate, termination of cable (excluding lighting circuit cables, from SLDB / ESLDB onwards upto the lighting fixtures) at designated location and other associated work so as to ensure the completeness of installation work.Scope shall include drilling of holes, if not provided by manufacturer.Supply of Crimping type Lugs shall be included in the cost. Type of Lug shall be as per type of terminals provided in equipment. For CT circuits Ring type lug shall be used. For Control cables,Tinned copper lugs shall be insulated, Ring / Pin / Fork crimping type as per terminal requirments.For Power cables, lugs shall be tinned copper / Aluminium (Tinned Copper lugs for copper conductor cable and Aluminium Lugs for Aluminium conductor cables ) tubular type, heavy duty long barrel lugs for bolted connection Supply and installation of Bi-metallic washer if the material of bus bar and Lugs are dissimilar are included in Contractor scope.
787MV POWER CABLESGlanding and Termination of 650 / 1100V (Uo / U) voltage grade, Al / Cu conductor (stranded / solid), XLPE insulated, screened, armoured power / lighting cables
788Cables with OD up to 20 mm
789Cables with OD above 20 mm but up to 30 mm
790Cables with OD above 30 mm but up to 40 mm
791Cables with OD above 40 mm but up to 50 mm
792Cables with OD above 50 mm but up to 60 mm
793Cables with OD above 60 mm but up to 80 mm
794MV CONTROL ,FIRE ALARM AND COMMUNICATION CABLES Glanding and Termination of 650 / 1100V (Uo / U) voltage grade, Al / Cu conductor (stranded / solid), PVC/XLPE insulated, screened, armoured control, Fire Alarm and Communication Cables
795All sizes from 2 to 7 cores and upto 2.5 sq. mm
796All sizes from 8 to 16 cores and upto 2.5 sq. mm
797All sizes from 17 to 24 cores and upto 2.5 sq. mm
798All sizes from 1P to 4P and upto 2.5 sq. mm
799All sizes from 5P to 10P and upto 2.5 sq. mm
800All sizes from 11P to 15P and upto 2.5 sq. mm
801All sizes from 16P to 30P and upto 2.5 sq. mm
802All sizes from 30P to 50P and upto 2.5 sq. mm
803All sizes from 50P to 100P and upto 2.5 sq. mm
804All sizes from 1T to 8T and upto 2.5 sq. mm
805Glanding and Termination of FIBRE OPTIC CABLES (Single Mode / Multi Mode)Scope includes Supply of kit, preparation of all fibres and splicing / patching, OTDR measurement, Supply of adequate consumables for the execution of the work (such as fibre optic connectors suitable for the application) testing, tools & tackles, manpower, etc. all complete as per direction of Engineer-in-Charge is included in scope.
806Fibre Optic Cable - 6 / 8 Fibre
807Fibre Optic Cable - 12 Fibre
808Fibre Optic Cable - 24 Fibre
809Termination of armoured Jelly filled cables and connection of leads excluding the supply of cable glands and lugs but including fixing of cable glands, supply and fixing of PVC shrouds for outdoor terminations, cutting, stripping of cable insulation, crimping the lug on to the conductor, clamping of the cable- cores, marking with wire number, ferrules etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Site Engineer-in-Charge
810All sizes from upto 5 pair
811All sizes above 5 pair upto 30pair
812All sizes above 30 pair upto 50pair
813All sizes above 50 pair upto 100pair
814WIRES AND FLEXIBLE CONDUCTOR CABLES
815Termination of 1100V, Multistranded Cu conductor, PVC insulated, flexible wires
816Cables with OD upto 20 mm.
817Cables with OD above 20 mm but upto 30 mm.
818Glanding & Termination of Special cables
819Silicon Insulated Flexible cable / Uninyvin cables
820Cables with OD upto 20 mm.
821Cables with OD above 20 mm up to 40 mm
822CAT 6A Cable (The scope includes supply of RJ 45 plug)
823Modbus RS 485
824CABLE JOINTING
825Handling, shifting from site-store / yard to the installation location, unpacking, erection, alignment, assembly and installation of straight through joint kits, installation of components supplied separately - as recommended by MANUFACTURER / applicable construction documents, and other associated work so as to ensure the completeness of installation work.Civil work such as construction of concrete chamber with cover (for cables directly buried underground) as per the site requirement (including the supply of consumable material for the same) is included in the scope.
826HV CABLES
827Straight through joint for 6.6 / 6.6 kV (UE) voltage grade, Al / Cu conductor, XLPE insulated, screened, armoured power cable
8283C x 240 sq.mm A2XCEFY (UE)
829Straight through joint for 33 / 33 kV (Uo / U)grade, Al conductor, XLPE insulated, screened, armoured power cable
8301C x 630 sq.mm A2XCEWaY
831MV CABLES
832650 / 1100V (Uo / U) voltage grade, Al / Cu conductor (stranded / solid), XLPE insulated, screened, armoured power / control / lighting cables
833Cables with OD upto 20 mm.
834Cables with OD above 20 mm but upto 30 mm.
835Cables with OD above 30 mm but upto 40 mm.
836Cables with OD above 40 mm but upto 50 mm.
837Cables with OD above 50 mm but upto 60 mm.
838Cables with OD above 60 mm but upto 80 mm.
839Installation of Jointing kits (for joints between Single/ MultiMode Fiber Optic armoured cables), Preparation of all fibres, splicing / patching, OTDR measurement, Supply of adequate consumables for the execution of the work (such as fibre optic connectors suitable for the application),testing, tools & tackles, manpower, etc. all complete as per direction of Engineer-in-Charge.
8406/8 Fiber
84124 Fiber
842PREFABRICATED CABLE TRAYS
843Handling, shifting from site-store / yard to the installation location, unpacking, erection, alignment, assembly and installation of prefabricated galvanized steel ladder type / perforated cable trays / FRP cable trays (above ground or inside concrete trenches) with all associated accessories such as bends, reducers, T-joints, fixing clamps, earthing continuity conductors etc. - as recommended by MANUFACTURER / applicable construction documents, fixing of cable trays / associated accessories to steel supports, stenciling with paint as required and other associated work so as to ensure the completeness of installation work.Site fabrication of cable tray accessories such as bends, reducers, T-joints etc. from cable tray straight runs as per the site requirement is included in the scope.For prefabricated cable trays accessories such as bends, reducers, T-joints etc. installtion of coupler plates is included in scope.For Ladder type Cable tray, the Bends/ Risers/ Tees are prefabricated/site fabricated. Cable tray bends/ riser/Tees etc on pipe rack are preferebally prefabricated. Rest of the bends can be site fabricated as per instructions given by Engineer-in-Charge. For perforated trays upto and including 150mm, the Bends/ Risers/ Tees/ Redcuers with covers shall be site fabricated as per instructions given by Engineer-in-ChargeFabrication and installation of steel support / bracket for cable trays / accessories as per the site requirement, is considered separately in this SOR.Supply of all fixing hardware as per the site requirement is included in the scope.
844Cable Trays Perforated (GI) and Accessories
845Installation of cable tray accessories such as bends, reducers, T-joints etc. is considered in cable tray running length.
84650 mm wide
847100 mm wide
848150 mm wide
849Cable Ladders (GI) and Accessories
850Installation of cable tray accessories such as bends, reducers, T-joints etc. is considered in cable tray running length.
851150 mm wide
852300 mm wide
853600 mm wide
854Cable Tray Covers (Bottom / TOP) (GI) and Accessories
855100 mm wide
856150 mm wide
857300 mm wide
858600 mm wide
859Separators for Cable Ladders (GI)
860300 mm / 600 mm wide
861CONDUITS FOR CABLE LAYING / PROTECTION
862Handling, shifting from site-store / yard to the installation location, unpacking, erection, alignment, assembly and installation of heavy duty rigid GI / PVC conduits on wall / concrete / steel structure (with edge protection grommet at either ends for GI conduits), cutting, bending of conduits and other associated work so as to ensure the completeness of installation work.Installation of GI clamps, reducers / adaptors for the conduits, tees, pull boxes as per the site requirement and the associated work is included in the scope.Supply of waterproof compound (of reputed make) and sealing of conduit openings after laying of cable by applying the same is included in the scope. Civil work such as chipping / drilling of through-holes / cutouts in floor / walls (as per the site requirement) and replastering and making area good after installation of conduits as per the site requirement (including the supply of consumable material for the same) is included in the scope.Supply of all fixing hardware as per the site requirement is included in the scope. Installation of conduits and associated accessories for 'Point Wiring for Office buildings / Control rooms / Other rooms with false ceiling' is considered separately in SECTION - C
863Rigid GI conduits
86425 mm nominal dia
86550 mm nominal dia
866100 mm nominal dia
867150 mm nominal dia
868Rigid GI conduits RED coloured (For Fire Alarm System cables)
86925 mm nominal dia
87050 mm nominal dia
871Heavy duty PVC conduits
87225 mm nominal dia
87350 mm nominal dia
874Flexible PVC conduits
87525 mm nominal dia
876LIGHTING, SMALL POWER, WELDING SOCKETS AND JUNCTION BOXES
877LIGHTING
878Installation of Industrial / For Explosive Atmospheres type lighting fixtures Handling, shifting from site-store / yard to the installation location, unpacking, erection, alignment, assembling and installation of lighting fixtures, assembling and installation of components / accessories such as lamps, chokes, condensers, reflectors, control gear box for non-integral fixtures etc. supplied separately - as recommended by MANUFACTURER / applicable construction documents, checking of internal wiring, stenciling with paint on equipment enclosures as required and other associated work so as to ensure the completeness of installation work'The scope is inclusive of Installation of loop-in / loop-out junction box / connector &associated with each fixtures- as per applicable installation details with associated cabling, glanding, termination of cable from Junction box / connectors toLight fixture.Installation of lighting fixtures shall be as per 'Installation Details - Lighting' and applicable construction documents.Testing, precommissioning and commissioning activities are included in the scope.Installation of lighting fixtures shall be as per 'Installation Details - Lighting' and applicable construction documents. The supply of installation materials (except lighting poles and structure steel) as per \\"Installation Details-Lighting\\" and including any additional material as per site requirement so as to ensure the completeness of installation work is included in the scope.
879Installation of Poles are considered separately.Fabrication, surface preparation, painting and installation of steel support of steel support structure / supporting frames as per the site requirement for above shall be considered separately in SECTION - F
880Lighting Fixtures
881Fluorescent lighting fixtures
882Installation Type : L09A
883Installation Type : L09B
884Installation Type : L09C
885Installation Type : L10
886Well glass lighting fixtures
887Installation Type : L07A
888Installation Type : L07B
889Installation Type : L07C
890Installation Type : L07D
891Installation Type : L07E
892Installation Type : L07F
893Installation Type : L04
894Installation Type : L05
895Installation Type : L06
896Medium bay / high bay lighting fixtures
897Installation Type : L13A
898Installation Type : L13B
899Installation Type : L13C
900Flood lighting fixtures
901Installation Type : L12
902Installation Type : L02
903Installation Type : L11
904Emergency lighting fixture with built-in battery (Installation types same as listed under Section C1.1.1 to C1.1.5)
905Insatallation Type : L09B
906Emergency EXIT sign with built-in battery
907Installation Type : L16
908Installation Type : L17
909Installation Type : L18
910Installation Type : L19
911Installation Type : L20
912Installation Type : L21
913Aviation light (flashing / steady burning) with controller
914Installation Type : L14A
915Installation Type : L14B
916Installation Type : L14C
917Vessel lamps
918Installation Type : Flange Mounted on Sight Glasses
919Installation of Lighting PolesInstallation, alignment & earthing of single arm GI lighting pole as per approved drawing along with supply of fixing hardware like U clamp & bolt, for platform mounted pole. Including welding, structuralworks, paint and all sundry materials as required. For ground mounted poles it includes supply and fixing of G.I pipes, G.I flat for earthing purpose, steel, base plates, paint and all sundry materials as required. Including all labour and materials complete as per approved drawings, specification of this tender and directions of Engineer-in-charge. This shall include local transportation from storage area to actual place of installation by contractor's own lifting & transporting arrangement.The installation of Lighting pole will be carried out as per IFC drawing & suit to site conditions to avoid fouling with other Piping, Structure & access ways. Refer tender documentation, including Typical installation drawings, RFC construction drawings and as per direction of Engineer In-Charge
920Installation details : L04
921Installation details : L05
922Installation details : L11
923Installation details : L14A
924Junction boxes for LightingHandling, shifting from site-store / yard to the installation location, unpacking, erection, alignment, assembling and installation of junction boxesand associated accessories on wall / concrete / steel structure - as recommended by MANUFACTURER / applicable construction documents, checking of internal wiring, stenciling with paint on equipment enclosures as required and other associated work so as to ensure the completeness of installation work.Testing, precommissioning and commissioning activities are included in the scope. Minor civil work such as chipping, grouting for fixing of various equipment, replastering and making area good etc.as per the site requirement (including the supply of consumable material for the same) is included in the scope. Installation of Junction Boxes shall be as per 'Installation Details - Lightingr' and applicable construction documents.The supply of installation materials (excludingstructure steel) as per \\"Installation Details-Lighting\\" and including any additional material as per site requirement so as to ensure the completeness of installation work is included in the scope.Supply of all fixing hardware as per the site requirement is included in the scope.Fabrication, surface preparation, painting and installation of steel support of steel support structure / supporting frames as per the site requirement for above shall be considered separately in SECTION - FInstallation of loop-in / loop-out junction box / connector are covered in the installation of respective light fixture installation. The qty indicated below are lighting junction boxes required for lighting branch circuits/
925Installation Type : L08B / L08C / L08D / L08E / L08F / L08G
926Point Wiring for Office buildings / Control rooms / Other rooms with false ceiling
927Installation of surface wiring / concealed wiring (in brick wall / decorative type aluminium partition in office rooms) using 2.5sq. mm flexible copper PVC wires, GI / PVC conduits, assembly and installation / embedding of heavy duty rigid GI / PVC conduits on / in wall / concrete structure (with edge protection grommet at either ends for GI conduits), cutting, bending of conduits - as per the applicable construction documents and other associated work so as to ensure the completeness of installation work.Installation of GI clamps, reducers / adaptors for the conduits, tees, pull boxes as per the site requirement and the associated work is included in the scope. Civil work such as chipping / drilling of through-holes / cutouts in walls (as per the site requirement) and replastering and making area good after embedding of conduits as per the site requirement (including the supply of consumable material for the same) is included in the scope.Testing, precommissioning and commissioning activities are included in the scope.Supply 2.5 sq.mm flexible copper PVC wires as requried, supply GI conduits for SURFACE CONDUIT WIRING / PVC conduits for CONCEALED CONDUIT WIRING and associated accessoreis such as GI clamps, reducers / adaptors for the conduits, tees, pull boxes, along with all fixing hardware as per the site requirement is included in the scope.For installation of wires above false ceiling / below false floor, conduits can be installed on surface of wall / concrete structure, after consultation with OWNER / CONSULTANT. Elsewhere, installation of wires shall be in concealed conduits.
928Primary Circuit (From SLDB / ESLDB / Lighting Junction Box upto Switch Box for local control)
9291 point (wire length approx. 20m)
9301 point (wire length approx. 30m)
9311 point (wire length approx. 40m)
9321 point (wire length approx. 50m)
9331 point (wire length approx. 60m)
934Secondary Circuit (From Switch Box for local control upto the lighting fixture / 5A/15A switch socket outlet / fan etc.)
9351 point (total wire length approx. 7m)
9362 point (total wire length approx. 15m)
9373 point (total wire length approx. 22m)
9384 point (total wire length approx. 30m)
9395 point (total wire length approx. 40m)
9406 point (total wire length approx. 50m)
9417 point (total wire length approx. 60m)
942Laying, Glanding and Termination for lighting circuit cables (650 / 1100V (Uo / U) voltage grade, Cu conductor (stranded / solid), XLPE insulated, armoured) from SLDB / ESLDB onwards upto the lighting fixtures / associated control gear boxes / junction boxes(applicable for all Lighting Fixtures, excluding Street Lighting Fixtures and Lighting Fixtures for Office buildings / Control rooms / Other rooms with false ceiling)Handling, shifting of cable drums from site-store / yard to the installation location, unpacking, laying of lighting circuit cables / wires in cable trays / through above ground conduits (PVC / GI) clamped on wall or structure or through floor conduits / by cleating of cables to concrete / wall / steel structrues by saddles - as per applicable construction documents and other associated work so as to ensure the completeness of installation work.Handling, shifting of cable drums from site-store / yard to the installation location, unpacking, laying of lighting circuit cables / wires in cable trays / through above ground conduits (PVC / GI) clamped on wall or structure or through floor conduits / by cleating of cables to concrete / wall / steel structrues by saddles - as per applicable construction documents and other associated work so as to ensure the completeness of installation work.Handling, shifting from site-store / yard to the installation location, unpacking, erection, alignment, assembly and installation of cable glands (industrial / For Explosive Atmospheres type) with PVC hoods, installation of components supplied separately - as recommended by MANUFACTURER / applicable construction documents, installation of lug, termination of cable at designated location and other associated work so as to ensure the completeness of installation work.Supply of all fixing hardware such as spacer bar, saddles, UV resistant PVC cable ties, Al cable tags, PVC hoods, etc. as as per the site requirement is included in the scope.Quantity of Lighting Fixtures, associated control gear boxes / junction boxes is defined in this document under the respective headings.The quantity of total looping cable length required for the work is mentioned below.
9433 C X 2.5 sq.mm
9443 C X 4 sq.mm
9453 C X 6 sq.mm
9463 C X 10 sq.mm
947EXHAUST FANS AND CEILING FANS
948Handling, shifting from site-store / yard to the installation location, unpacking, erection, alignment, assembling and installation of exhaust / ceiling fans and associated accessories - as recommended by MANUFACTURER / applicable construction documents, checking of internal wiring other associated work so as to ensure the completeness of installation workTesting, precommissioning and commissioning activities are included in the scope.Minor civil work such as chipping, modifications in the wall cutout as required, grouting of frame, replastering and making area good etc.as per the site requirement (including the supply of consumable material for the same) is included in the scope. Supply of all fixing hardware as per the site requirement is included in the scope.
949Industrial type Exhaust fans
950300mm dia.
951450mm dia.
952600mm dia.
953Exhaust fans For Explosive Atmospheres
954300mm dia.
955450mm dia.
956600mm dia.
957SMALL POWER
958Handling, shifting from site-store / yard to the installation location, unpacking, erection, alignment, assembling and installation of small power equipment and associated accessories such as control switches, socket outlets, modular box, face plate etc. - as recommended by MANUFACTURER / applicable construction documents, checking of internal wiring other associated work so as to ensure the completeness of installation workTesting, precommissioning and commissioning activities are included in the scope.Minor civil work such as chipping, grouting for fixing of various equipment, replastering and making area good etc.as per the site requirement (including the supply of consumable material for the same) is included in the scope. Supply of all fixing hardware as per the site requirement is included in the scope.
959SWITCH SOCKET OUTLETS
960Civil work such as chipping of walls (as per the site requirement) and replastering and making area good after embedding of modular boxes for switch boxes, as per the site requirement (including the supply of consumable material for the same) is included in the scope.
961Decorative type switch socket outlets
962Decorative type switch socket box with 1 no. 5/15A switch socket unit and 1 no. piano type switch
963Decorative type switch socket box with 1 no. 5/15A switch socket unit and 2 nos. piano type switches
964Decorative type switch socket box with 1 no. 5/15A switch socket unit and 3 nos. piano type switches
965Decorative type switch socket box with 1 no. 5/15A switch socket unit and 4 nos. piano type switches
966Decorative type switch socket box with 1 no. 5/15A switch socket unit and 5 nos. piano type switches
967Decorative type switch socket box with 1 no. 5/15A switch socket unit
968Decorative type switch in single module with 1 no. 5A piano type switches
969Decorative type switch in double module with 2 no. 5A piano type switches
970Decorative type switch in tripple module with 3 no. 5A piano type switches
971Decorative type switch in quad module with 4 no. 5A piano type switches
972Decorative type switch socket switchboard with 5/15A, 5 pin, socket outlet with 15A switch and 'ON' LED indication & fuse
973Surface / Concealed mounting type ( 2-Module) RJ 11 / RJ 45 Connectors Female type complete with Moduler box, cover plate etc. for telephones
974Industrial type switch socket outlets (for Indoor Installation)
97520A, single phase switch socket outlet with 1no. 3 pin socket and 1 No. 20 A, 10 kA, SPMCB, in sheet steel enclosure
976CONVENIENCE SWITCH SOCKET OUTLETS (Wall/column/structure/Railing mounted)
977Installation of Industrial / Explosive Atmospheres type Switch Socket Outlets shall be as per 'Installation Details - Lighting and applicable construction documents.Supply of Installation materials (excluding structure steel) as per 'Installation Details - lighting' is included in the scope.Fabrication and installation of steel support structure as per the site requirement, is considered separately in SECTION - F.
978Convenience sockets (single phase)Installation Type : L15A / L15B / L15C / L15D
97924V, 5A switch socket unit for Industrial / Explosive Atmospheres, with built-in 100VA, 220V / 24V transformer, Installation Type : L15A / L15B / L15C / L15D
980JUNCTION BOXES (JB) AND POWER JUNCTION BOXES (PJB) FOR MOTORS / OTHER EQUIPMENT - - Industrial / Explosive Atmospheres type
981Handling, shifting from site-store / yard to the installation location, unpacking, erection, alignment, assembling and installation of junction boxes (except lighting JB) / power junction boxes and associated accessories on wall / concrete / steel structure - as recommended by MANUFACTURER / applicable construction documents, checking of internal wiring, stenciling with paint on equipment enclosures as required and other associated work so as to ensure the completeness of installation work.Testing, precommissioning and commissioning activities are included in the scope.Supply of Installation materials (excluding structure steel) as per Installation details-Power is included in the scope.Fabrication and installation of steel support structure as per the site requirement, is considered separately in SECTION - F.Installation of Junction Boxes shall be as per 'Installation Details - Power' and applicable construction documents.
982Weight of Unit up to 5 kg
983Weight of Unit above 5 kg, but up to 20 kg
984Weight of Unit above 20 kg, but up to 100 kg
985Weight of Unit above 100 kg, but up to 200 kg
986POWER SOCKET OUTLETS
987Handling, shifting from site-store / yard to the installation location, unpacking, erection, alignment, assembling and installation of switch socket outlets and associated accessories such as control switches, socket outlets, junction box, front plate etc. on wall / concrete / steel structure - as recommended by MANUFACTURER / applicable construction documents, checking of internal wiring, stenciling with paint on equipment enclosures as required and other associated work so as to ensure the completeness of installation work.Testing, precommissioning and commissioning activities are included in the scope.Installation of Industrial / Explosive Atmospheres type Power socket outlets shall be as per 'Installation Details - Power' and applicable construction documents.Supply of Installation materials (excluding structure steel) as per 'Installation Details - Power' is included in the scope.Fabrication and installation of steel support structure as per the site requirement, is considered separately in SECTION - F.
988Industrial / Explosive Power Socket Outlets
989Installation Type : P10A/B
990Installation Type : P15
991Installation Type : P17
992FIRE ALARM AND COMMUNICATION SYSTEMS
993FIRE ALARM (FA) SYSTEM
994Handling, shifting from site-store / yard to the installation location, unpacking, assembling and installation of various components in FA system and associated accessories such as manual call points, plug-in devices, bases for devices etc. on wall / concrete / steel structure - as recommended by MANUFACTURER / applicable construction documents, stenciling with paint on equipment enclosures as required andand other associated work so as to ensure the completeness of installation work.Testing and precommissioning activities, commissioning assistance as required by MANUFACTURER's supervisor is included in the scope. Minor civil work such as chipping, grouting for fixing of various equipment and replastering the same as per the site requirement (including the supply of consumable material for the same) is included in the scope. Supply of Installation materials (excluding structure steel) as per 'Installation Details - FA System' is included in the scope.Supply of all fixing hardware as per the site requirement is included in the scope.Installation shall be as per 'Installation Details - Fire Alarm System' and applicable construction documents.Fabrication and installation of steel support structure as per the site requirement, is considered separately in SECTION - F.
995Central FA panelTAG : LATERApprox. Dimensions (LxBxH) : 600 x 600 x 2000 mmApprox. Weight : 200 kgsMounting : Wall mounted / Column mounted / On False floor supported with structural steel base frame Location : SRR (Indoor)
996FA system accessories Industrial type / Explosive Atmospheres
997Installation Type: FAHC1
998Installation Type: FAHS1
999Installation Type: FAHZ1
1000Installation Type: FASC1
1001Installation Type: FASC2
1002Installation Type: FASS1
1003Installation Type: FCPC1
1004Installation Type: FCPC2
1005Installation Type: FCPP1
1006Installation Type: FCPP2
1007Installation Type: FCPR1
1008Installation Type: FCPS1
1009Installation Type: FMDC1
1010Installation Type: FMDF1
1011Installation Type: FMDF2
1012Installation Type: FMDF3
1013Installation Type: FMDS1
1014Installation Type: FRIC1
1015Installation Type: FRIF1
1016Installation Type: FCPS2
1017Installation Type: CFBC1
1018Installation Type: CFBS1
1019PUBLIC ADDRESS (PA) SYSTEM
1020Handling, shifting from site-store / yard to the installation location, unpacking, assembling and installation of various components in PA system and associated accessories such as field call stations, acoustic hoods etc. on desk / wall / concrete / steel structure - as recommended by MANUFACTURER / applicable construction documents, stenciling with paint on equipment enclosures as required and other associated work so as to ensure the completeness of installation work.Testing and precommissioning activities, commissioning assistance as required by MANUFACTURER's supervisor is included in the scope. Minor civil work such as chipping, grouting for fixing of various equipment and replastering the same as per the site requirement (including the supply of consumable material for the same) is included in the scope.Supply of Installation materials (excluding structure steel) as per 'Installation Details - Communication & PA System' is included in the scope. Supply of all fixing hardware as per the site requirement is included in the scope.Installation shall be as per 'Installation Details - Communication & PA System' and applicable construction documents.Fabrication and installation of steel support structure as per the site requirement, is considered separately in SECTION - F.
1021Central PA panelApprox. Dimensions (LxBxH) : 800 x 800 x 2000 mmApprox. Weight : 250 kgsMounting : On False floor supported with structural steel base frame Location : SRR (Indoor)
1022Master Control StationInstallation of Master Control Station (MCS) consisting of control key board, Loud speaker, goose-neck microphone, console mounted handset, headset and other accesories (Installation Type: CMCS1)Mounting : Desk stop
1023PA system accessories Industrial type / Explosive Atmospheres
1024Installation Type: CTFC1
1025Installation Type: CTFC2
1026Installation Type: CTFR1
1027Installation Type: CTFR2
1028Installation Type: CTFS2
1029Installation Type: CTFS3
1030Installation Type: CFBC1
1031Installation Type: CFBR1
1032Installation Type: CFBS1
1033Installation Type: CSPKC1
1034Installation Type: CSPKC2
1035Installation Type: CSPKC3
1036Installation Type: CSPKF1
1037Installation Type: CSPKP1
1038Installation Type: CSPKS1
1039Installation Type: CSPKR1
1040Installation Type: CMCS1
1041TELEPHONE SYSTEMHandling, shifting from site-store / yard to the installation location, unpacking, assembling and installation of various components in PA system and associated accessories such as field call stations, acoustic hoods etc. on desk / wall / concrete / steel structure - as recommended by MANUFACTURER / applicable construction documents, stenciling with paint on equipment enclosures as required and other associated work so as to ensure the completeness of installation work.Testing and precommissioning activities, commissioning assistance as required by MANUFACTURER's supervisor is included in the scope. Minor civil work such as chipping, grouting for fixing of various equipment and replastering the same as per the site requirement (including the supply of consumable material for the same) is included in the scope.Supply of Installation materials (excluding structure steel) as per 'Installation Details - Communication & PA System' is included in the scope. Supply of all fixing hardware as per the site requirement is included in the scope.Installation shall be as per 'Installation Details - Communication & PA System' and applicable construction documents.Fabrication and installation of steel support structure as per the site requirement, is considered separately in SECTION - F.
1042Installation of Telephine Ststem cabinet onsists of Access switch, Media gate wat etc
1043Installation shall be as per 'Installation Details - Communication & PA System' and applicable construction documents.
1044Telephone ( Industrial type / Explosive Atmospheres)
1045Installation Type: CTFC2
1046Installation Type: CTFS2
1047Installation Type: CTFZ1
1048Junction boxes
1049Telephone System Junction Box / IDF with 1 nos. 20 Pair incoming cable(s) and 20 nos 1 Pair outgoing cable(s)
1050CCTV SYSTEMHandling, shifting from site-store / yard to the installation location, unpacking, assembling and installation of various components in CCTV system and associated accessories such as cameras, JBs, plug-in devices, bases for devices etc. on wall / concrete / steel structure / Self standing - as recommended by MANUFACTURER / applicable construction documents, stencilling with paint on equipment enclosures as required and other associated work so as to ensure the completeness of installation work.Supply of all the Installation Material and Installation shall be as per 'Installation Details - Communication & PA System' and applicable construction documents and applicable construction documents, including any additional material as per site requirement so as to ensure the completeness of installation work.and as per approved drawings, specifications of this tender and directions of Engineer-in-Charge..Testing and precommissioning activities, commissioning assistance as required by MANUFACTURER's supervisor is included in the scope. Minor civil work such as chipping, grouting for fixing of various equipment and replastering the same as per the site requirement (including the supply of consumable material for the same) is included in the scope.
1051CCTV CabinetApprox. Dimensions (LxBxH) : 800 x 800 x 2000 mmApprox. Weight : 250 kgsMounting : On False floor supported with structural steel base frame Location : SRR (Indoor)
1052Cameras
1053Installation of Cameras including wiper & washer system and mounting poles/ structures, with required civil foundations, supply and installations erection material etc. as applicable are included in scope
1054Installation Type: CTVC1
1055Installation Type: CTVC2
1056Installation Type: CTVR1
1057Installation Type: CTVS1
1058EARTHING AND LIGHTNING PROTECTION
1059Handling, shifting from site-store / yard to the installation location, unpacking, assembling and installation of earthing and lightning protection systems and accessories underground / wall / concrete / steel structure / cable trays - as recommended by MANUFACTURER / applicable construction documents and other associated work so as to ensure the completeness of installation work.Testing, precommissioning and commissioning activities are included in the scope.
1060EARTHING
1061Installation shall be as per 'Installation Details - Earthing' and applicable construction documents.
1062Installation of earth conductor laid underground
1063Installation and connection of GI earthing strip buried individually at a depth of 600 mm including welding at joints, providing anti-corrosive paint r bitumen and jute covering for welded portion, clamping and necessary hardware for connecting, excavation and refilling etc., including all labour and materials, as per approved drawings & specifications For GI earthing conductors, laying of conductor including bending, drilling, welding / jointing as required is included in the scope.For GI earthing conductors, supply and application of coal tar bituminous paint or cold galvanising paint on welded joints is included in the scope.Excavation of soil up to the required depth, installation of earth conductor (GI strip / bare copper conductor / insulated copper cable), back filling and compacting of soil and disposing the excess soil, termination as required is included in the scope
106440 x 5 mm GI strip
106525x 6 mm GI strip
106650 x 6 mm HDGI strip
106775 x 10 mm HDGI strip
1068Installation of earth conductor laid on wall / concrete / steel structure / cable traysInstallation of earth conductor (GI strip) on wall / concrete / steel structure / cable trays by cleating at every 500mm, termination as requied.For GI earthing conductors, laying of conductor including bending, drilling, welding / jointing as required is included in the scope.For GI earthing conductors, supply and application of coal tar bituminous paint or cold galvanising paint on welded joints is included in the scope.Supply of all fixing hardware as per the site requirement is included in the scope.
106950 x 6 mm HDGI strip
107075 x 10 mm GI strip
1071Installation of earth conductor to be embedded in finished concrete floorsInstallation of earth conductor (GI strip) on concrete floorsFor GI earthing conductors, laying of conductor including bending, drilling, welding / jointing as required is included in the scope.For GI earthing conductors, supply and application of coal tar bituminous paint or cold galvanising paint on welded joints is included in the scope.Civil work such as chipping / drilling of through-holes / cutouts in floor and replastering and making area good after installation of conductor as per the site requirement (including the supply of consumable material for the same) is included in the scope.
107240 x 5 mm GI strip
107350 x 6 mm GI strip
107475 x 10 mm GI strip
1075Installation of earthing / lightning protection electrodes
1076Excavation of soil upto the required depth, installation and testing of earth electrode, filling of the pit with the appropriate material as required, earthing connection of earth electrode with main earth grid, back filling, compacting of soil, disposing the excess soil.Civil work including construction of concrete chamber with cover for the earth pit as per the site requirement is included in the scope.
1077Installation Type : E01A
1078Installation Type : E01B
1079Installation of earth busesInstallation and testing of earth buses on wall / concrete / steel structure / cable trays.Supply of all fixing hardware as per the site requirement is included in the scope.Fabrication and installation of steel support structure as per the site requirement, is considered separately in SECTION - F.
1080Installation Type : E02A
1081Installation Type : E02B
1082Installation Type : E20
1083Installation Type : E22
1084Install following Earthing Material as per Installation Type : E141. 9 DIA G.I. BAR2. SHARP JAW TONG TYPE HEAVY DUTY SPRING CLAMP-100A
1085Installation of Pipe line Flange/ Pipe Earthing material as per Installation Standard E09/E10 (Doc. No.TK-1P22A-EL-STD-0003), .This shall include installation of 10 MM (3/8\\") DIA GI WIRE ROPE for the no. of Flange connections.The Termination scope also includes supply of lugs for GI wire rope and all hardware etc. Refer List For Pipe Line Bonding (Doc. No.TK-1P22A-EL-LST-0010 ) for details of Flange earthing
1086LIGHTNING PROTECTION
1087Installation shall be as per 'Installation Details - Lightning Protection' and applicable construction documents.
1088Installation of lightning protection conductor laid on wall / concrete / steel structure / roof Installation of lightning protection conductor (GI strip) on wall / concrete / steel structure including the installation of test links and accessories, insulator supports, termination as required.For GI earthing conductors, laying of conductor including bending, drilling, welding / jointing as required is included in the scope.Supply of Installation materials (excluding structure steel) as per installation details-Earthing\\" is included in the scope.Supply of all fixing hardware as per the site requirement is included in the scope.
108925 x 6 mm HDGI strip
1090Installation of lightning protection rods / finials
1091Installation of of lightning arrestors, including the required supporting arrangement.
1092Supply of all fixing hardware as per the site requirement is included in the scope.
1093Installation Type : E24
1094Installation Type : E25
1095Installation Type : E26
1096Installation Type : E27
1097STRUCTURAL STEEL
1098Fabrication, erection (by welding / fixing by anchor fastners), surface preparation and painting of structural steel as per the applicable construction documents so as to ensure the completeness of installation work for all the electrical equipment / items mentioned in Section A to E above, and chequered plates as per the applicable construction documents.Supply of all consumables such as welding electrodes (Advani Oerlikon or equivalent), gas for cutting etc. are included in the scope.Measurement of steel quantity for installation shall be based on actual quantities installed at site without wastage allowance. Surface preparation and painting of steel shall be as per doc. TP-1ZZZA-PI-SPE-0003. (Technical Specification for Painting)
1099Structural steel (MS)
1100Galvanised Iron (GI)
1101MISCELLANEOUS ITEMS
1102CIVIL WORK
1103Excavation
1104Excavation in soil for the purpose of cable laying activity up to a depth of 2m (maximum) and width of trench 4m (maximum) considering all the relevant safety standards, backfilling the excavated area after cable laying activity, consolidation after backfilling and disposing the surplus earth at required location.Installation of soft sand of known resistivity, red coloured concrete tiles of appropriate voltage grade for cable protection, warning tapes, cable markers(including RFID tags) etc. (after cable laying activity is completed) is included in the scope.
1105Soft / medium soil (Excavation & Back-filling)
1106Miscellaneous civil work
1107Activities indicated below are already included in 'SECTIONS - A to E' of this document. Unit rates are requested in the event that additional work is required over and above that already identified in 'SECTIONS - A to E'.The below mentioned rates shall be applicable only if specifically agreed & approved by OWNER / CONSULTANT.
1108Chipping / drilling of through-holes / cutouts in concrete floor / beam, replastering and finishing the same
1109Chipping / drilling of through-holes / cutouts in brick walls and replastering the same.
1110Manual excavation of all types of soil and backfilling the excavated area, consolidation after backfilling and disposing the surplus earth at a point outside the site
1111Laying of RCC hume pipes of dia 150mm for road crossing including excavation of road upto a depth of 1500 mm back filling and consolidating the surface. Supply of RCC hume pipes of reputed make as required, and civil work such as excavation, installation of hume pipes (including the supply of consumable material for the same), backfilling is included in the scope.
1112filling/spreading of certified soft sand of known resistivity in the concrete trenches build by others after laying of cables, compacting the same. The scope includes removal of RCC trench covers/ slab, refixing of RCC trench Covers/Slabs after filling / spreading the sand, including all labour and materials complete as per approved drawings, specification of this tender and directions of Engineerin-in-charge
1113Installation of approved second class bricks of 75 mm thickness in cable trenches for cable protection, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. (Actual area of laid brick surfaces shall be measured).
1114Installation of approved Red coloured concrete tiles in cable trenches for cable protection, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. (Actual area of laid brick surfaces shall be measured). The scope includes supply and installation of warning tape as per Installation details
1115Anchor fasteners
1116Installation of heavy duty Galvanised steel anchor fasteners for supporting various equipment, in brick work / concrete workInstallation of anchor fasteners indicated below excludes those already considered in various applicable 'Installation Details' mentioned in 'SECTIONS - A to E' in this document.Installation of anchor fasteners indicated below excludes those already considered in various applicable 'Installation Details' mentioned in 'SECTIONS - A to E' in this document
1117Anchor fasteners M8 type x 60mm
1118Anchor fasteners M10 type x 75 mm
1119Anchor fasteners M12 type x 100 mm
1120SAFETY ITEMS
1121Installation of safety items mentioned below, in all the electrical rooms / buildings / transformer yards, etc. as per applicable statutory requirements / HSE documents / as indicated in applicable construction documents.
1122Enameled caution boards for 33 kV.
1123Enameled caution boards for 6.6 kV.
1124Enameled caution boards for 1.1 kV.
1125Enameled Danger plates to be installed in electrical rooms such as transformer bay, switchgear room etc.
11263 ply Lamicoid tag plates of appropriate size for various equipment, with White letters on Black background, as per the site requirement
1127Epoxy insulating floor coating (Valency Compound Make - Valency-111 CLASS A or equivalent
112833kV System
11296.6 kV systems -
1130upto 1.1 kV systems
1131Installation of Synthetic Insulating mat (as per IS 15652: 2006). The rate shall include cutting to required size and placing the mats in front of switchgear panels as directed by Site Engineer-in-charge. The mat shall be permanently pasted on the floor.
113233kV System
11336.6 kV systems -
1134upto 1.1 kV systems
1135First aid information chart (for electrical hazards such as Shock treatment) : Framed laminated shock treatment chart, conforming to IE rules, in English and local language. Name, address and telephone number of nearest doctor shall be mentioned in it.
1136First aid boxes along with required medicines / medical equipment, containing ointments for treatment of electrical burns, conforming to IE rules.
1137Wall mounted, Electrical Single Line Diagrams-A0 size\\" for the unit including frame, glass, hardwares, etc.
1138GENERAL ITEMS
1139Installation of general items mentioned below, as required.
1140Office tables of reputed make
1141Office chairs of reputed make
1142Full size Cupboard of reputed make, sheet steel enclosure (for documentation)
1143Tool Cabinet, Wall Mounted
1144Key Cabinet, Wall Mounted
1145Tarpaulin (for weather protection of stored electrical equipment)
1146Insulated step ladder of reputed make (suitable for indoor work in switchgear rooms)
1147Installation of Fire proofing of cables up 3 m length at entry points of both endsincluding all labour and materials required. (Actual area of surface painted shall be measured) _ - (As perIEC 60331) Fire proof paint for cables for 1 hour Fire Rating (CABLE SURFACE AREA WISE)Fire retardant cable coatingHILTI : CP679A / OBO BETTERMAN equivalent product
1148Installation of Fire Stop (Fire sealing) material suitable to withstand for 240 min including all labour and materials required for sealing the wall / Floor opening / conduits fire sealings. Refer annex EW4-6 for details of openings to be sealed
1149Installation of Fire Stop (Fire sealing) material suitable to withstand for 90 min including all labour and materials required for sealing the wall / Floor opening / conduits fire sealings. Refer annex EW4-6 for details of openings to be sealed
1150Installation of Weather proofing material HILTI make including all labour and materials required for sealing the wall opening / conduits fire sealings.
1151ELECTRICAL STATUTORY APPROVAL
1152Obtaining approval on applicalbe Released for Construction (RFC) / Final drawings, commencement certificate from concerned authorities, approval of installations, liasoning with electrial inspector, organising inspector visits to site ( up to 3 visits) as required as per applicable statutory norms, etc. and all the associated work
1153MANPOWER SUPPLY RATES PER DAY
1154The below mentioned rates for Manpower Supply shall be applicable only for work performed over and above the electrical works already defined as forming part of CONTRACTOR’s scope in the Tender Document / Contract.Note: These rates for man power are applicable only after total completion of Electrical Installation & Commissioning activities. This shall also include the Implementation of LOTO system during precommissioning & commissioning stage . The below mentioned rates shall be applicable only if specifically agreed & approved by OWNER / CONSULTANT. Please Enable Macros to View BoQ information
1155The below mentioned rates for Manpower Supply shall be applicable only for work performed over and above the electrical works already defined as forming part of CONTRACTOR’s scope in the Tender Document / Contract.Note: These rates for man power are applicable only after total completion of Electrical Installation & Commissioning activities. This shall also include the Implementation of LOTO system during precommissioning & commissioning stage . The below mentioned rates shall be applicable only if specifically agreed & approved by OWNER / CONSULTANT. Please Enable Macros to View BoQ information

Other Detail

Information Source https://eprocure.gov.in/eprocure/app
Download FileName File Description File Size
Download Part_II_8.rar Tender Documents 0 KB
Download Part_II_9.rar Tender Documents 0 KB
Download Tendernotice_1.pdf Tender Documents 0 KB
Download 2b7c7377-8856-4001-ad58-82d9529f3300.html Tender Documents 0 KB
Download BOQ_956524.xls Tender Documents 0 KB
Download Part-I.rar Tender Documents 0 KB
Download Part-III.rar Tender Documents 0 KB
Download Part_II_1.rar Tender Documents 0 KB
Download Part_II_2.rar Tender Documents 0 KB
Download Part_II_3.rar Tender Documents 0 KB
Download Part_II_4.rar Tender Documents 0 KB
Download Part_II_5.rar Tender Documents 0 KB
Download Part_II_6.rar Tender Documents 0 KB
Download Part_II_7.rar Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.