Tender No WBPWD/AE/103/PR/T/KCESD/I of 2025-26(2nd call)
Tender ID 2026_WBPWD_5014270_1
Tender Brief Corrigendum : Tender For Repairing & Renovation Of Whole Electrical Wirings In The Ib Drivers Barrack Room No. 83 & 84 In The Premises Of Intelligence Branch,At 13 Lord Sinha Road.Kol-71
City Kolkata
State West Bengal
Document Fees Refer document
EMD INR 3277.0 /-
Tender Value INR 1.63 Lakhs /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender For Repairing & Renovation Of Whole Electrical Wirings In The Ib Drivers Barrack Room No. 83 & 84 In The Premises Of Intelligence Branch,At 13 Lord Sinha Road.Kol-71

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 05-06-2026 Date Corrigendum Date 12-06-2026

Key Dates

Publish Date 05-06-2026
Last Date of Bid Submission 12-06-2026
Tender Opening Date 15-06-2026

Contact Information

Company Name public works department
Contact Person AE/KCESD-I
Address Khadya_Bhawan_11A_Mirza_Ghalib_Street_Block_B_6th_Floor_Kokata_700087

BOQ Items

Name of Work:- Repairing & renovation of whole electrical wirings in the IB Drivers Barrack Room No. 83 & 84 in the premises of Intelligence Branch,at 13 Lord Sinha Road.kol-71
Sl. No. Item Description
1Disconnecting the power flow through existing electrical arrangements & dismantling charges for the existing old electrical installations [Lights-7 Nos, Switch Boards-7 Nos (incl. computer board, Power points), Wires (incl. point wirings, power ckt. wirings, computer boards)] and mending goods the damages using co's own tools, tackles and necy. arrangements by 1 No. Semi-Skilled and 2 No. Unskilled labour for 1 Day.
2S & F of 63A, 415V, TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. (Make: L&T)
3S & F 4 Way double door Horizontal TPN MCB Distribution board with IP-42/43 protection, with 415V, 63A FP MCB Isolator as incomer & 12 Nos. 240V, 6-32A SP MCB of breaking capacity 10kA & C Characteristics as outgoing, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. (Make: Legrand)
4S & F 240V, 6-10A per way, (2+8) Way SPN MCB DB with SS enclouser double door with IP- 42/43 protection with 40 A DP Isolator as incomer & 8 Nos. 6-10 A SP MCB's ('C' Curve, 10kA) as outgoing concealed in wall after cutting the wall and mending the good damages to original finish incl. Inter connection with suitable size of copper wire and neutral link and provision for earthing attachment as to G.S. (Make: Legrand)
5Supplying & Delivery 1.1 KV grade 4 Core 25 Sq.mm XLPE/PVC Al Armoured Cable. (Make: Polycab / KEI / Gloster)
6Laying of cable 4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting.
7Laying of one No. 4 Core 25 Sqmm cable in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed
8S & F compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of 4 Core 25 Sqmm XLPE/PVC armoured cables as below:
9Finishing the end of 4 Core 25 Sqmm XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials.
10Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) (Make: Polycab / KEI / Gloster / RR Kabel / Havells) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Make: Legrand) (Brand approved by EIC) fixed on Modular GI switch board with top cover plate and 2 no. suitable size “Ph & N” copper bar & earthing attachment fixed on wall incl. mending good damages to original finish.
11(i) Average run 9 mtrs.
12(i) on board
13Supply & Delivery of 240V, 18 W, 4 Ft. long single / twin fluorescent polycarbonate body LED tubelight with fittings incl. necessary accessories.
14(i) Philips TMC 502 1xT-LED 22W with 1 No. Mas LEDTube 1200mm 18W 865 T8 I – 2100lm / Eqv. Crompton, Wipro.
15Fixing only single / twin fluorescent light fitting complete with all accessories directly on wall / ceiling / HW round block and suitable size of MS fastener.
16S & F of 240V, 18 Watt 4Ft. Long polycarbonate body LED Tubelight. (Make: Mas LEDTube 1200mm 18W 865 T8 I – 2100lm)
17S & F 240 V, 1 No. 6 A & 16 A 3 pin Modular type plug socket with 1 No. 6A & 16 A Modular type switch on 6 Module GI Modular type switch board with 6 Module top cover plate flushed in wall complete with 2 No. suitable size \\"Ph & N\\" copper bar incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (Make: Legrand)
18S & F 240 V, 2 Nos. 6 A, 3 pin Modular type plug socket with 2 Nos. 6A, Modular type switch on 6 Module GI Modular type switch board with 6 Module top cover plate flushed in wall complete with 2 No. suitable size \\"Ph & N\\" copper bar incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (Make: Legrand)
19S & F 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) (Make: Legrand) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
20S & F 2(+1) Module IP-65 rated waterproof cabinet on wall including necessary accessories with S&F 240V, 32A DP MCB Isolator incl. necy. connections, socketing etc. as per direction of EIC. (Make: Legrand)
21S & F 240V, OLP-3+, 25A Starter with digital display including S&F of 4 module GI box including necessary connections of starter. (Make: Electron)
22S & F of 20mm PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works.
23Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Make: Polycab / KEI / Gloster / RR Kabel) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required.
24(i) 3 x 1.5 Sq.mm.
25(i) 2x2.5 sq.mm +1x1.5 sq.mm1 x 1.5 Sq.mm as ECC
26(iii) 2 x 4 Sq.mm + 1 x 2.5 Sq.mm as ECC
27(iv) 2 x 6 Sq.mm + 1 x 4 Sq.mm as ECC
28Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
29(i) 3x1.5 Sqmm
30(i) 2x2.5 sq.mm +1x1.5 sq.mm
31(iii) 2 x 4 Sq.mm + 1 x 2.5 Sq.mm.
32(iv) 2 x 6 Sq.mm + 1 x 4 Sq.mm. Please Enable Macros to View BoQ information

Other Detail

Information Source https://tenders.wb.gov.in/nicgep/app
Download FileName File Description File Size
Download 02d2167e-8a46-4101-8354-78267cdc3c18.html Tender Documents 0 KB
Download 2911.pdf Tender Documents 0 KB
Download BOQ_5082273.xls Tender Documents 0 KB
Download Tendernotice_1 (11).pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.