Indian Tenders

Tender Notice

TDR 55675506
Tendering Authority Public Works Department
Tender No WBPWD/AE/KMCESD/NIQ-01/26-27
Tender ID 2026_WBPWD_5014192_1
Tender Brief Corrigendum : Tender For Supply Installation Testing and Commissioning of Concealed Split Type Ac Machine In Room No-211 (Teaching Bay), Under Rio Medical College & Hospital, Kolkata-- Electrical Installation Work
City Kolkata
State West Bengal
Document Fees Refer document
EMD INR 3480.0 /-
Tender Value Refer document
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Supply Installation Testing and Commissioning of Concealed Split Type Ac Machine In Room No-211 (Teaching Bay), Under Rio Medical College & Hospital, Kolkata-- Electrical Installation Work

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 01-06-2026 Corrigendum for Date Extension Date 12-06-2026

Key Dates

Publish Date 01-06-2026
Last Date of Bid Submission 12-06-2026
Tender Opening Date 15-06-2026

Contact Information

Company Name Public Works Department
Contact Person Assistant Engineer, KMC Electrical Sub-Division
Address Kolkata Medical College Electrical Sub-Division, P.W.Dte.Green Building, MCH Campus 88, College Street, Kolkata-700073.

BOQ Items

Name of Work:- SITC of Concealed Split type AC machine in Room No-211 (Teaching Bay), under RIO Medical College & Hospital, kolkata-- Electrical Installation Work
Sl. No. Item Description
1Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Make-Legrand/Schneider/ABB/Siemens) 4 way as to GS. (Vide page no D-11 item no 15)
2Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for TPN DB horizontal / vertical enclosure with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish with nuts bolts etc incl. provision for earthing attachment (Make-Legrand/Schneider/ABB/Siemens) Vide page no D-12 item no 164 way vertical TPNDB
3Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection (Make-Legrand/Schneider/ABB/Siemens) Vide page no D-8 item no 10100 A FP for VTPNDB
4Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. (Make-Legrand/Schneider/ABB/Siemens)(Vide page no D-6 item no 7)i. 32A TP MCB (for VTPNDB out going)
5ii. 32A FP MCB (for out door unit)
6Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required. Vide pg noG-2 item no. 4(a)
7B. Supply of cables :---Supplying and Delivery of 1.1 KV Gr. following sizes Al. armoured PVC / XLPE insulated cable (Mk. Gloster / Polycab / Havell's/KEI) as mentioned below : 4 core 50 sqmm (from panel to VTPNDB )
84 core 10 sqmm (from panel to 2nos. AC starter & timer & OD unit)
9C. Laying of cables :---Laying of 4 core 50 sqmm Al. armoured PVC/XLPE cable with 2X10 SWG GI wire making hole etc. as necy., mending good damages and painting as mentioned below : (from VTPNDB to PBDB) (Vide page no F-1,F-3 Item no 2 ,5, 6)on wall by clamp
10Concealed in wall
11on cable tray
12Laying of 4 core 10 sqmm Al. armoured PVC/XLPE cable with 2X 8 SWG GI wire making hole etc. as necy., mending good damages and painting as mentioned below :(for lift 1.one new cable 2. relaying of one old cable) (Vide page no F-1,F-3 Item no 2 ,5, 6) on wall by clamp
13Concealed in wall
14on cable tray
15Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : (vide pg no F-4 item no. 7.C) 4 core 50 sqmm
164 core 10 sqmm
17Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials. (vide pg no F-5 item no. 8a & 9) 4 core 50 sqmm
184 core 10 sqmm
19S&F 415V, 3 phase, 50 Hz A.C starter unit in SS enclosure make :-- LK ( Cat. No-- MU-G10H DOL starter) with relay range 20-32A incl. S&F Analog/digital time switch LK make 10 - 240 VAC 1 C/O Base/DIN 25 ON/OFF Each cat no-- 67DDT0 -- 1no, on channel and 2 no cable end box
20S & F PVC water proof looping cable box (make - Sintex, size-- 250x200x105 mm) having hinged type PVC top cover having 4 mm thick rubber gasket lining & earthing terminal etc .The box should comprising of 1 no. din rail for fixing of 415V, 63A, 4P MCB (make-- L&T) and 63A 4 way Terminal bar etc. complete with all accessories as per direction of EIC
21S & F 3 phase timer box with front open hinged type dooor to control 1 nos. 3 phase AC machine and providing incoming and outgoing copper wire and other accessories on iron frame on wall and making necy. connection as reqd. Timer box made of 14 SWG MS sheet (size approx– 18\\" X 18\\" X 6\\") with powder coated synthetic paint , inter locking system consisting the following materials : 1) S & F 24 Hr. programmable digital timer – 1 no.2) S & F 440 Volt 63A 4P power contactor (MCX 12 with (no+nc) contact) – 1 no.3) 6 amp auto manual toggle switch – 1 no. (L &T)4) Indicating lamp (R,Y,B,AC1,AC2) (L&T) – 3 nos.5) SPP - 1no.6) 100A capacity 4W Brass stud type connector on FRP chair for I/C - 1nos. 7) 63A TPN MCB I/C - 1 no. 8) 4 pole 63A change over switch - 1 nos. (Mk.-L&T) All control circuit wiring would be made by 1x2.5 sqmm stranded Cu wire(FRLS) and the I/G & O/G circuit with 1x10 sqmm copper wire maintaining colour code incl taping, socketing to complete the work. The box should be fixed on wall with suitable size of flush nut and necy. Connection. [NS]. Drawing shouid be approved from EIC before fabrication Work.
22Distribution wiring in 1.1 KV single core stranded 'FR'PVC insulated & unsheathed copper wire (Make: Polycab/ Havells/ Glostar/ KEI) in 25mm size PVC rigid conduit 'FR'(Precision make) incl. necy. fittings as required. vide pg no E-14 item no. 1B2 X 4 sqmm + 2 x 2.5 sqmm ( for AC starter, timer)
23Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. vide pg no F-5 item no. 9 4.0 sqmm
242.5 sqmm
25Special Terms and Conditions1. It is stated that the above work place is existing COVID Hospital, In case of any mishap or accidental to any staff that deputed by the agency the whole responsibility is to be borne by the concern agency.2. The Agency shall be responsible for provisioning of all COVID safety measures including regular sanitiziation of work places, vaccination of employees and compliance of stated directive and COVID appropriate norms.3. All the issues related to the safety of the staffs should be taken care by the agency itself.(Defect Libilities period for 01 year from the date of completion of work)(Rate should be quotated including all taxes and duties) Please Enable Macros to View BoQ information

Other Detail

Information Source https://tenders.wb.gov.in/nicgep/app
Download FileName File Description File Size
Download 2911_Form.pdf Tender Documents 0 KB
Download b8e98261-e03c-42df-a009-efeb85a896a4.html Tender Documents 0 KB
Download BOQ_5082160.xls Tender Documents 0 KB
Download suspension.pdf Tender Documents 0 KB
Download Tendernotice_1 (11).pdf Tender Documents 0 KB
Disclaimer :