Indian Tenders

Tender Notice

TDR 55654101
Tendering Authority Madhyanchal Vidut Vitran Nigam Limited
Tender No 10/EDCB/2026-27
Tender ID 2026_MVVNL_1152792_1
Tender Brief Corrigendum : Tender For For Installation Of New Distribution Transformers Under Business Paln 2026-27 Scheme Under Edd-Baheri
City Bareilly
State Uttar Pradesh
Document Fees INR 3540 /-
EMD INR 54658.0 /-
Tender Value INR 54.65 Lakhs /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for For Installation Of New Distribution Transformers Under Business Paln 2026-27 Scheme Under Edd-Baheri

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 11-06-2026 10/EDCB/2026-27_1 Date 15-06-2026
2 08-06-2026 10/EDCB/2026-27 Date 11-06-2026
3 08-06-2026 10/EDCB/2026-27 Date 11-06-2026

Key Dates

Publish Date 11-06-2026
Last Date of Bid Submission 15-06-2026
Tender Opening Date 15-06-2026

Contact Information

Company Name Madhyanchal Vidut Vitran Nigam Limited
Contact Person SUPERINTENDING ENGINEER
Address ELECTRICITY DISTRIBUTION CIRCLE, KATJU MARG, BAREILLY

BOQ Items

Name of Work:- For Installation of New Distribution Transformers under Business Paln 2026-27 scheme Under EDD-Baheri
Sl. No. Item Description
1The work of safe carriage of the following material from CB Ganj store center to work site under the jurisdiction of EDD-Baheri Approx. distance upto 100 Km. Including safe loading and unloading.
2PCC Pole 8.5 Mtr
3ACSR Weasal Conductor
4ACSR Rabbit Conductor
5AB Cable 3x95 sqmm
6AB Cable 3x120 sqmm
711/0.4 KV 3 Phase 250 KVA T/F
811/0.4 KV 3 Phase 100 KVA T/F
911/0.4 KV 3 Phase 63 KVA T/F
10LT Cable 1x70 sqmm
11LT Cable 1x120 sqmm
12LT Cable 1x240 sqmm
13Other Line material i.e., 33 KV & 11 KV pin insulater/stay/earthing complete/Disc Fitting/Disc Insulators/Dropper Channel/Crossing Bracing/ Top Channel/Binding Wire/Danger Board/Barbed Wire/numberplate/stone pad/Control Cable etc
14Construction of T/F plinth 2x2x1 m3 or Minimum 4 Cubic Meter (As per Site Requirement) for mounting 250 KVA T/F including foundation work (below ground 0.5 M), Brick work, RCC slab of 4” thickness and plastering in 1:6 ratio with 02 Nos channel pieces of 1.5 mtr long of size 100x50x6 mm compete in all respect
15Cage fencing of 250 KVA Plinth mounted transformer in Town areas to avoid electrical human/cattle accidents by fabrication of cage (1 Inch Sq wiremesh) made of 10 No gauge in suitable size angle iron frame of size 7.5'(L)x5'(W)x8’(H) or Minimum 200 Sq Feet (As per Site Requirement)by strenghtening of wire mesh 20x3 mm M.S. flat haorizentally as well as vertically, Grouting the panel with 1:2:4 cement/coorse send/brick ballast. The Frame should be bolted on angles at the four corners so that frame may be un-bolted/bolted at the time of replacement of the transformer. Provision of 1 gate should be there for maintenance of the transformer. Painting (1 coat of red oxide + 2 coat of Bus green enamel paint). The wire mesh should be earthed with 50x6 mm MS earthing strip with existing earthing of Transformer Body. All men, material and T&P provided by the contractor to complete the fabrication, transportation and installation.
16Pipe Earthing of Transformer (By boring of 4 inch diameter 20 m deep, 40 mm diameter A class GI pipe is inserted to a depth of 20 m and a holed pipe of 1.5 m length is inserted at the bottom. Tighten one end of the MS strip of size 50x6mm with the nut bolt with the neutral of the converter and weld the other end with the GI pipe inserted in the boring for earthing. Putting a socket on the upper part of the pipe (mouth) so that water can be poured into it to retain moisture. To complete the work Contractor will provide all material, Manpower, T&P, safe carriage of material to worksite. Above work will be carried out under supervision of concerned JE/SDO/EE)
17Mounting of 250 KVA T/F Transformers as per norms complete in all respect -
18Mounting of 100 KVA T/F Transformers as per norms complete in all respect -
19Mounting of 63 KVA T/F Transformers as per norms complete in all respect -
20Fabrication & Installation of 11 KV Fuse set comptele unit to be installed on midway of 11 KV Double Pole Structure Complete in all respect
21Installation of LT Fuse Box With SMC Box Complete in all respect
22Erection of Single/Double pole in H.T/L.T lines including fitting of all accessories as per RESSPO Norms
23PCC Pole 8.5 Mtr (Single)
24PCC Pole 8.5 Mtr (Double)
25Grouting of following Pole with 1:4:8 mixture in size(450x450x1500mm.) including cost of cement/BB & sand Required as per RESSPO Norms
26PCC Pole 8.5 Mtr (Single)
27PCC Pole 8.5 Mtr (Double)
28Laying of LT Lead XLPE Cable 1x70 sqmm Complete in all respect
29Laying of LT Cable 1x120 sq mm complete in all respect
30Laying of LT Cable 1x240 sq mm complete in all respect
31The work of Driving the earthing electrode and making connections with 6 S.W.G. GI wire as per RESSPO Norms
32Laying, Stringing & Sagging of Following Conductor complete in all respect
33ACSR Weasal Conductor
34ACSR Rabbil Conductor
35AB Cable 3x95 sqmm
36AB Cable 3x120 sqmm
37The work of digging of pits, erection of Stay Clamp, Insulator etc.
38Grouting of stays, 1:4:8 cc ratio (600x600x300mm.) as per RESPO norms.
39Fixing of 3 Pahse Distribution Box complete in all respect
40Supply and Fixing of Following Material as per RESPO norms complete in all respect (would be Provided by contractor through approved vendors of Discom at his own cost)
41Holding Clamp for S/s
42F Clamp With Nut & Bolt
43X Arm Holding Clamp with N&B
44PG Clamp
45Stone Pad 300x300x75 mm
46Danger Board With Clamp
47Barbed Wire
48Distribution Box Clamp
49Piercing Connector
50Suspension Clamp
51J Hook
52Dead End Clamp
53Eye Hook
54LT Clamp with Nut & Bolt
55LT T OFF
56Stay Clamp
57Stay Insulator
58Earthwire Clamp
59Aluminium Lug 70 sqmm with Nut&Bolt
60Aluminium Lug 95 sqmm with Nut&Bolt
61Aluminium Lug 240 sqmm with Nut&Bolt
62LT Fuse Set Protection for DT with SMC Box
63TC Fuse Wire of Various Size
6411 KV Fuse Set Complete (11 KV DO Fuse Set- 1 Nos, MS Channel 100x50x2028mm-1 No., Holding Clamp with n&B-2 Nos, Al Lug 70 Sqmm-9 Nos)
65LT Shackle Insulator
66Tail Less Unit Suitable For 250 KVA TF
67Copper \\"L\\" Piece 50x225x10 mm For Tail less Unit Please Enable Macros to View BoQ information

Other Detail

Information Source https://etender.up.nic.in
Download FileName File Description File Size
Download BOQ_2159551.xls Tender Documents 0 KB
Download de082d67-2859-49b5-881d-b4172d83d574.html Tender Documents 0 KB
Download Tendernotice_1 (18).pdf Tender Documents 0 KB
Download Tender_form.pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.