Indian Tenders

Tender Notice

TDR 55654097
Tendering Authority Madhyanchal Vidut Vitran Nigam Limited
Tender No 14/EDCB/2026-27
Tender ID 2026_MVVNL_1152865_1
Tender Brief Corrigendum : Tender For For Increasing Capacity Of Existing Distribution Transformer Of Various Capacity & Installation Of New Distribution Transformers Under Business Plan 2026-27 Scheme Under Edd-Aonla
City Bareilly
State Uttar Pradesh
Document Fees INR 3540 /-
EMD INR 31859.0 /-
Tender Value INR 31.85 Lakhs /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for For Increasing Capacity Of Existing Distribution Transformer Of Various Capacity & Installation Of New Distribution Transformers Under Business Plan 2026-27 Scheme Under Edd-Aonla

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 15-06-2026 14/EDCB/2026-27_2 Date 18-06-2026
2 11-06-2026 14/EDCB/2026-27_1 Date 15-06-2026
3 11-06-2026 14/EDCB/2026-27_1 Date 15-06-2026
4 08-06-2026 14/EDCB/2026-27 Date 11-06-2026
5 08-06-2026 14/EDCB/2026-27 Date 11-06-2026
6 08-06-2026 14/EDCB/2026-27 Date 11-06-2026

Key Dates

Publish Date 15-06-2026
Last Date of Bid Submission 18-06-2026
Tender Opening Date 19-06-2026

Contact Information

Company Name Madhyanchal Vidut Vitran Nigam Limited
Contact Person SUPERINTENDING ENGINEER
Address ELECTRICITY DISTRIBUTION CIRCLE, KATJU MARG, BAREILLY

BOQ Items

Name of Work:- For Increasing Capacity of Existing Distribution Transformer of Various Capacity & Installation of New Distribution Transformers under Business Plan 2026-27 scheme Under EDD-Aonla
Sl. No. Item Description
1The work of safe carriage of the following material from CB Ganj store center to work site under the jurisdiction of EDD-Aonla Approx. distance upto 100 Km. Including safe loading and unloading.
2PCC Pole 8.5 Mtr
3ACSR Weasal Conductor
4AB Cable 3x50 sqmm
5AB Cable 3x95 sqmm
611/0.4 KV 3 Phase 250 KVA T/F
711/0.4 KV 3 Phase 100 KVA T/F
811/0.4 KV 3 Phase 63 KVA T/F
9LT Cable 1x120 sqmm
10LT Cable 1x400 sqmm
11LT Cable 3.5x70 sqmm
12Other Line material i.e., 33 KV & 11 KV pin insulater/stay/earthing complete/Disc Fitting/Disc Insulators/Dropper Channel/Crossing Bracing/ Top Channel/Binding Wire/Danger Board/Barbed Wire/numberplate/stone pad/Control Cable etc
13Construction of T/F plinth 2x2x1 m3 or Minimum 4 Cubic Meter (As per Site Requirement) for mounting 250 KVA T/F including foundation work (below ground 0.5 M), Brick work, RCC slab of 4” thickness and plastering in 1:6 ratio with 02 Nos channel pieces of 1.5 mtr long of size 100x50x6 mm compete in all respect
14Cage fencing of 250 KVA Plinth mounted transformer in Town areas to avoid electrical human/cattle accidents by fabrication of cage (1 Inch Sq wiremesh) made of 10 No gauge in suitable size angle iron frame of size 7.5'(L)x5'(W)x8’(H) or Minimum 200 Sq Feet (As per Site Requirement)by strenghtening of wire mesh 20x3 mm M.S. flat haorizentally as well as vertically, Grouting the panel with 1:2:4 cement/coorse send/brick ballast. The Frame should be bolted on angles at the four corners so that frame may be un-bolted/bolted at the time of replacement of the transformer. Provision of 1 gate should be there for maintenance of the transformer. Painting (1 coat of red oxide + 2 coat of Bus green enamel paint). The wire mesh should be earthed with 50x6 mm MS earthing strip with existing earthing of Transformer Body. All men, material and T&P provided by the contractor to complete the fabrication, transportation and installation.
15Pipe Earthing of Transformer (By boring of 4 inch diameter 20 m deep, 40 mm diameter A class GI pipe is inserted to a depth of 20 m and a holed pipe of 1.5 m length is inserted at the bottom. Tighten one end of the MS strip of size 50x6mm with the nut bolt with the neutral of the converter and weld the other end with the GI pipe inserted in the boring for earthing. Putting a socket on the upper part of the pipe (mouth) so that water can be poured into it to retain moisture. To complete the work Contractor will provide all material, Manpower, T&P, safe carriage of material to worksite. Above work will be carried out under supervision of concerned JE/SDO/EE)
16Dismentaling of 100 KVA Transformer as per norms complete in all respect
17Mounting of 250 KVA T/F Transformers as per norms complete in all respect -
18Mounting of 100 KVA T/F Transformers as per norms complete in all respect -
19Mounting of 63 KVA T/F Transformers as per norms complete in all respect -
20Fabrication & Installation of 11 KV Fuse set comptele unit to be installed on midway of 11 KV Double Pole Structure Complete in all respect
21Installation of LT Fuse Box With SMC Box Complete in all respect
22Erection of Single/Double pole in H.T/L.T lines including fitting of all accessories as per RESSPO Norms
23PCC Pole 8.5 Mtr (Single)
24PCC Pole 8.5 Mtr (Double)
25Grouting of following Pole with 1:4:8 mixture in size(450x450x1500mm.) including cost of cement/BB & sand Required as per RESSPO Norms
26PCC Pole 8.5 Mtr (Single)
27PCC Pole 8.5 Mtr (Double)
28Laying of LT Cable 1x120 sq mm complete in all respect
29Laying of LT Cable 1x400 sq mm complete in all respect
30Laying of LT Cable 3.5x70 sq mm complete in all respect
31The work of Driving the earthing electrode and making connections with 6 S.W.G. GI wire as per RESSPO Norms
32Laying, Stringing & Sagging of Following Conductor complete in all respect
33ACSR Weasal Conductor
34AB Cable 3x50 sqmm
35AB Cable 3x95 sqmm
36The work of digging of pits, erection of Stay Clamp, Insulator etc.
37Grouting of stays, 1:4:8 cc ratio (600x600x300mm.) as per RESPO norms.
38Fixing of 3 Pahse Distribution Box complete in all respect
39Supply and Fixing of Following Material as per RESPO norms complete in all respect (would be Provided by contractor through approved vendors of Discom at his own cost)
40Holding Clamp for S/s
41PG Clamp
42Stone Pad 300x300x75 mm
43Danger Board With Clamp
44Barbed Wire
45Distribution Box Clamp
46Piercing Connector
47Suspension Clamp
48J Hook
49Dead End Clamp
50Eye Hook
51LT T OFF
52All Leg Long Barrel off Size
53Stay Clamp
54Stay Insulator
55Earthwire Clamp
56Aluminium Lug 70 sqmm with Nut&Bolt
57Aluminium Lug 150 sqmm with Nut&Bolt
58LT Fuse Set Protection for DT with SMC Box
59TC Fuse Wire of Various Size
6011 KV Fuse Set Complete (11 KV DO Fuse Set- 1 Nos, MS Channel 100x50x2028mm-1 No., Holding Clamp with n&B-2 Nos, Al Lug 70 Sqmm-9 Nos)
61Tail Less Unit Suitable For 250 KVA TF
62Copper \\"L\\" Piece 50x225x10 mm For Tail less Unit
63Aluminium Bus Bar 65x10mm
64Safe back carriage of Following item (if any) from work site to C.B. Ganj store Bareilly approx distance upto100 Km including loading & unloading.
6511/0.4 KV 3 Phase 100 KVA T/F Please Enable Macros to View BoQ information

Other Detail

Information Source https://etender.up.nic.in
Download FileName File Description File Size
Download 9d24b7e6-cb71-4b83-b209-7b63078562d4.html Tender Documents 0 KB
Download BOQ_2159652.xls Tender Documents 0 KB
Download Tendernotice_1 (18).pdf Tender Documents 0 KB
Download Tender_form.pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.