| 1 | The work of safe carriage of the following material from CB Ganj store center to work site under the jurisdiction of EDD-Aonla Approx. distance upto 100 Km. Including safe loading and unloading. |
| 2 | PCC Pole 8.5 Mtr |
| 3 | ACSR Weasal Conductor |
| 4 | AB Cable 3x50 sqmm |
| 5 | AB Cable 3x95 sqmm |
| 6 | 11/0.4 KV 3 Phase 250 KVA T/F |
| 7 | 11/0.4 KV 3 Phase 100 KVA T/F |
| 8 | 11/0.4 KV 3 Phase 63 KVA T/F |
| 9 | LT Cable 1x120 sqmm |
| 10 | LT Cable 1x400 sqmm |
| 11 | LT Cable 3.5x70 sqmm |
| 12 | Other Line material i.e., 33 KV & 11 KV pin insulater/stay/earthing complete/Disc Fitting/Disc Insulators/Dropper Channel/Crossing Bracing/ Top Channel/Binding Wire/Danger Board/Barbed Wire/numberplate/stone pad/Control Cable etc |
| 13 | Construction of T/F plinth 2x2x1 m3 or Minimum 4 Cubic Meter (As per Site Requirement) for mounting 250 KVA T/F including foundation work (below ground 0.5 M), Brick work, RCC slab of 4” thickness and plastering in 1:6 ratio with 02 Nos channel pieces of 1.5 mtr long of size 100x50x6 mm compete in all respect |
| 14 | Cage fencing of 250 KVA Plinth mounted transformer in Town areas to avoid electrical human/cattle accidents by fabrication of cage (1 Inch Sq wiremesh) made of 10 No gauge in suitable size angle iron frame of size 7.5'(L)x5'(W)x8’(H) or Minimum 200 Sq Feet (As per Site Requirement)by strenghtening of wire mesh 20x3 mm M.S. flat haorizentally as well as vertically, Grouting the panel with 1:2:4 cement/coorse send/brick ballast. The Frame should be bolted on angles at the four corners so that frame may be un-bolted/bolted at the time of replacement of the transformer. Provision of 1 gate should be there for maintenance of the transformer. Painting (1 coat of red oxide + 2 coat of Bus green enamel paint). The wire mesh should be earthed with 50x6 mm MS earthing strip with existing earthing of Transformer Body. All men, material and T&P provided by the contractor to complete the fabrication, transportation and installation. |
| 15 | Pipe Earthing of Transformer (By boring of 4 inch diameter 20 m deep, 40 mm diameter A class GI pipe is inserted to a depth of 20 m and a holed pipe of 1.5 m length is inserted at the bottom. Tighten one end of the MS strip of size 50x6mm with the nut bolt with the neutral of the converter and weld the other end with the GI pipe inserted in the boring for earthing. Putting a socket on the upper part of the pipe (mouth) so that water can be poured into it to retain moisture. To complete the work Contractor will provide all material, Manpower, T&P, safe carriage of material to worksite. Above work will be carried out under supervision of concerned JE/SDO/EE) |
| 16 | Dismentaling of 100 KVA Transformer as per norms complete in all respect |
| 17 | Mounting of 250 KVA T/F Transformers as per norms complete in all respect - |
| 18 | Mounting of 100 KVA T/F Transformers as per norms complete in all respect - |
| 19 | Mounting of 63 KVA T/F Transformers as per norms complete in all respect - |
| 20 | Fabrication & Installation of 11 KV Fuse set comptele unit to be installed on midway of 11 KV Double Pole Structure Complete in all respect |
| 21 | Installation of LT Fuse Box With SMC Box Complete in all respect |
| 22 | Erection of Single/Double pole in H.T/L.T lines including fitting of all accessories as per RESSPO Norms |
| 23 | PCC Pole 8.5 Mtr (Single) |
| 24 | PCC Pole 8.5 Mtr (Double) |
| 25 | Grouting of following Pole with 1:4:8 mixture in size(450x450x1500mm.) including cost of cement/BB & sand Required as per RESSPO Norms |
| 26 | PCC Pole 8.5 Mtr (Single) |
| 27 | PCC Pole 8.5 Mtr (Double) |
| 28 | Laying of LT Cable 1x120 sq mm complete in all respect |
| 29 | Laying of LT Cable 1x400 sq mm complete in all respect |
| 30 | Laying of LT Cable 3.5x70 sq mm complete in all respect |
| 31 | The work of Driving the earthing electrode and making connections with 6 S.W.G. GI wire as per RESSPO Norms |
| 32 | Laying, Stringing & Sagging of Following Conductor complete in all respect |
| 33 | ACSR Weasal Conductor |
| 34 | AB Cable 3x50 sqmm |
| 35 | AB Cable 3x95 sqmm |
| 36 | The work of digging of pits, erection of Stay Clamp, Insulator etc. |
| 37 | Grouting of stays, 1:4:8 cc ratio (600x600x300mm.) as per RESPO norms. |
| 38 | Fixing of 3 Pahse Distribution Box complete in all respect |
| 39 | Supply and Fixing of Following Material as per RESPO norms complete in all respect (would be Provided by contractor through approved vendors of Discom at his own cost) |
| 40 | Holding Clamp for S/s |
| 41 | PG Clamp |
| 42 | Stone Pad 300x300x75 mm |
| 43 | Danger Board With Clamp |
| 44 | Barbed Wire |
| 45 | Distribution Box Clamp |
| 46 | Piercing Connector |
| 47 | Suspension Clamp |
| 48 | J Hook |
| 49 | Dead End Clamp |
| 50 | Eye Hook |
| 51 | LT T OFF |
| 52 | All Leg Long Barrel off Size |
| 53 | Stay Clamp |
| 54 | Stay Insulator |
| 55 | Earthwire Clamp |
| 56 | Aluminium Lug 70 sqmm with Nut&Bolt |
| 57 | Aluminium Lug 150 sqmm with Nut&Bolt |
| 58 | LT Fuse Set Protection for DT with SMC Box |
| 59 | TC Fuse Wire of Various Size |
| 60 | 11 KV Fuse Set Complete (11 KV DO Fuse Set- 1 Nos, MS Channel 100x50x2028mm-1 No., Holding Clamp with n&B-2 Nos, Al Lug 70 Sqmm-9 Nos) |
| 61 | Tail Less Unit Suitable For 250 KVA TF |
| 62 | Copper \\"L\\" Piece 50x225x10 mm For Tail less Unit |
| 63 | Aluminium Bus Bar 65x10mm |
| 64 | Safe back carriage of Following item (if any) from work site to C.B. Ganj store Bareilly approx distance upto100 Km including loading & unloading. |
| 65 | 11/0.4 KV 3 Phase 100 KVA T/F Please Enable Macros to View BoQ information |