Tender Brief Corrigendum : Tender For For Strenthening Of 33 Kv Lines, Sub Station & Dt Protection Works Etc At Various Places Under B.P 2026-27 Under Edd-Shahjhanpur Road, Bareilly
City Bareilly
State Uttar Pradesh
Document Fees INR 3540 /-
EMD INR 22125.0 /-
Tender Value INR 22.12 Lakhs /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for For Strenthening Of 33 Kv Lines, Sub Station & Dt Protection Works Etc At Various Places Under B.P 2026-27 Under Edd-Shahjhanpur Road, Bareilly

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 15-06-2026 09/EDCB/2026-27_2 Date 18-06-2026
2 11-06-2026 09/EDCB/2026-27_1 Date 15-06-2026
3 11-06-2026 09/EDCB/2026-27_1 Date 15-06-2026
4 08-06-2026 09/EDCB/2026-27 Date 11-06-2026
5 08-06-2026 09/EDCB/2026-27 Date 11-06-2026
6 08-06-2026 09/EDCB/2026-27 Date 11-06-2026

Key Dates

Publish Date 15-06-2026
Last Date of Bid Submission 18-06-2026
Tender Opening Date 19-06-2026

Contact Information

Company Name Madhyanchal Vidut Vitran Nigam Limited
Contact Person SUPERINTENDING ENGINEER
Address ELECTRICITY DISTRIBUTION CIRCLE, KATJU MARG, BAREILLY

BOQ Items

Name of Work:- For Strenthening of 33 KV Lines, Sub Station & DT Protection works etc at Various Places under B.P 2026-27 under EDD-Shahjhanpur Road, Bareilly
Sl. No. Item Description
1The work of safe carriage of the following material from CB Ganj store center to work site under the jurisdiction of EDD-Shahjhanpur Road Bareilly, Bareilly Approx. distance upto 80 Km. Including safe loading and unloading.
2PCC Pole 9 Mtr
3PCC Pole 11 Mtr
4ACSR DOG Conductor
533 KV XLPE 3x300 Sq Mm
6Outdoor 33 KV Jointing Kit Sutable for 33 KV XLPE Cable 3x300 sqmm
7Straight Through 33 KV Jointing Kit Sutable for 33 KV XLPE Cable 3x300 sqmm
833 KV PT
933 KV Lightening Arrestor
10Battery Set (12 Cell, 2 V, 200AH)
11Battery Charger
1233 KV Double Transformer Control Panel
13Other Line material
14Erection of Single/Double pole in H.T/L.T lines including fitting of all accessories as per RESSPO Norms
15PCC Pole 9 Mtr (Single)
16PCC Pole 9 Mtr (Double)
17PCC Pole 11 Mtr (Single)
18PCC Pole 11 Mtr (Double)
19Grouting of following Pole with 1:4:8 mixture in size(450x450x1500mm.) including cost of cement/BB & sand Required as per RESSPO Norms
20PCC Pole 9 Mtr (Single)
21PCC Pole 9 Mtr (Double)
22PCC Pole 11 Mtr (Single)
23PCC Pole 11 Mtr (Double)
24The work of Driving the earthing electrode and making connections with 6 S.W.G. GI wire as per RESSPO Norms
25Laying, Stringing & Sagging of Following Conductor complete in all respect
26ACSR DOG Conductor
27The work of digging of pits, erection of Stay Clamp, Insulator etc.
28Grouting of stays, 1:4:8 cc ratio (600x600x300mm.) as per RESPO norms.
29Under Ground Laying of 33 KV XLPE Cable 3x300 sqmm by digging trench method as per norms complete in all respect
30Supply & Laying of 6\\" dia G Pipe at various places i.e road crossing & Hoisting etc. complete in all respect ((ISO certified GI pipe 150 NB 3 mm thick dia 6\\" would be Provided by contractor at his own cost)
31Filling of Outdoor Cable Jointing Kit suitable for 33 KV 3x300 sqmm Xlpe Cable complete in all respect
32Filling of Straigh Through Cable Jointing Kit suitable for 33 KV 3x300 sqmm Xlpe Cable complete in all respect
33Gaurding as per norms complete in all respect
34Cage fencing of 250 KVA Plinth mounted transformer in Town areas to avoid electrical human/cattle accidents by fabrication of cage (1 Inch Sq wiremesh) made of 10 No gauge in suitable size angle iron frame of size 7.5'(L)x5'(W)x8’(H) or Minimum 200 Sq Feet (As per Site Requirement)by strenghtening of wire mesh 20x3 mm M.S. flat haorizentally as well as vertically, Grouting the panel with 1:2:4 cement/coorse send/brick ballast. The Frame should be bolted on angles at the four corners so that frame may be un-bolted/bolted at the time of replacement of the transformer. Provision of 1 gate should be there for maintenance of the transformer. Painting (1 coat of red oxide + 2 coat of Bus green enamel paint). The wire mesh should be earthed with 50x6 mm MS earthing strip with existing earthing of Transformer Body. All men, material and T&P provided by the contractor to complete the fabrication, transportation and installation.
35Pipe Earthing of Transformer (By boring of 4 inch diameter 20 m deep, 40 mm diameter A class GI pipe is inserted to a depth of 20 m and a holed pipe of 1.5 m length is inserted at the bottom. Tighten one end of the MS strip of size 50x6mm with the nut bolt with the neutral of the converter and weld the other end with the GI pipe inserted in the boring for earthing. Putting a socket on the upper part of the pipe (mouth) so that water can be poured into it to retain moisture. To complete the work Contractor will provide all material, Manpower, T&P, safe carriage of material to worksite. Above work will be carried out under supervision of concerned JE/SDO/EE)
36Installation/Errection/Fixing of 33 KV PT as per norms complete in all respect
37Installation/Errection/Fixing of 33 KV Lightening Arrestor as per norms complete in all respect
38Installation/Errection/Fixing of 33 KV Double Transformer Control Panel as per norms complete in all respect
39Installation of Battery Set/ Battery Charger as per norms complete in all respect
40Supply & Fixing of Over current Earthfault Relay 1/5 Amp as per norms complete in all respect
41Supply & Fixing of OTI & WTI Relay as per norms complete in all respect
42Supply & Fixing of WTI as per norms complete in all respect
43Supply & Fixing of OTI as per norms complete in all respect
44Supply and Fixing of Following Material as per RESPO norms complete in all respect (would be Provided by contractor through approved vendors of Discom at his own cost)
45Stone Pad 300x300x75 mm
46Holding Clamp with Nut & Bolt for T Off, Cross Arm and Expouser Pole
47Danger Board & Clamps with Nut & Bolt
48Barbed Wire
4933 KV F-Bracket with Nut & Bolt
50Stay Clamp
51Stay Insulator
52Eye Bolt for guard wire
53Clamp for Guarding Angle
54MS Nut & Bolt Please Enable Macros to View BoQ information

Other Detail

Information Source https://etender.up.nic.in
Download FileName File Description File Size
Download 90d87933-de0c-4c7b-90e0-587525a5e561.html Tender Documents 0 KB
Download BOQ_2159521.xls Tender Documents 0 KB
Download Tendernotice_1 (18).pdf Tender Documents 0 KB
Download Tender_form.pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.