| 1 | For EDD Chandausi, Sambhal and Babrala |
| 2 | Safe carriage of the following Centralised material from Store Centre to site /JE store with loading & unloading at both ends respectively. |
| 3 | stay wire 7/8 SWG, 10 KG, Stay Clamp, Bolt, nut and washer with concrete grouting) |
| 4 | 11 KV \\"V\\" type cross arm 65x65x6 mm, M S Angle |
| 5 | 11 KV \\"V\\" type cross Arm |
| 6 | 11 KV V type Steel Cross Arm |
| 7 | 11 KV cable jointing kit 3×300 mm straight through 11 kv 300mmsq |
| 8 | 11 kV XLPE cable 3x185 mm² |
| 9 | 11 kV XLPE cable 3x300 mm² |
| 10 | ABC CABLE 3*120+1*95+1*16MM SQ. (5% SAG+ 1 %CONNECTION) |
| 11 | LT ABC (3x95+1x70+1x16) Sq. mm |
| 12 | LT ABC (3x50+1x35+1x16) Sq. mm |
| 13 | ACSR Dog Conductore |
| 14 | ACSR Rabbit Conductore |
| 15 | ACSR Wesal Conductor |
| 16 | Cable AL. 3X300 sq.mm XLPE 11KV |
| 17 | Cable jointing kit out door 11 kV 185 mm² |
| 18 | Disc Fitting for T&C 45 KN |
| 19 | Disc Insulator T&C 45 KN |
| 20 | Earthing of pole by MS earthing rod of 20x2500mm & 6 SWG Earthing wire Etc |
| 21 | MS T-off Channel 125x65 1300 mm |
| 22 | Extra for stays at angle Location (Stay rod 16x1800mm, Stay wire 5 kg, stayclamp, bolts & nut with grouting) |
| 23 | 3-Phase Distribution box |
| 24 | LT Distribution box |
| 25 | 13 meter ST Pole-SP-70 |
| 26 | 11 meter ST Pole-SP-55 |
| 27 | PCC 11 Mtr Long |
| 28 | PCC Support 8.5 Mtr. Long |
| 29 | Polymeric 11KV Pin Insulator |
| 30 | Polymeric 33KV Pin Insulator |
| 31 | Polymeric 11KV Pin with nut |
| 32 | Stay set Complete |
| 33 | Proper Installation/Fabrication/laying/fixing/binding etc. of the Following Material With All the Accessories (as per resspo norms) |
| 34 | stay wire 7/8 SWG, 10 KG, Stay Clamp, Bolt, nut and washer with concrete grouting) |
| 35 | 11 KV \\"V\\" type cross arm 65x65x6 mm, M S Angle |
| 36 | 11 KV \\"V\\" type cross Arm |
| 37 | 11 KV V type Steel Cross Arm |
| 38 | 11 KV cable jointing kit 3×300 mm straight through 11 kv 300mmsq |
| 39 | 11 kV XLPE cable 3x185 mm² |
| 40 | 11 kV XLPE cable 3x300 mm² |
| 41 | ABC CABLE 3*120+1*95+1*16MM SQ. (5% SAG+ 1 %CONNECTION) |
| 42 | LT ABC (3x95+1x70+1x16) Sq. mm |
| 43 | LT ABC (3x50+1x35+1x16) Sq. mm |
| 44 | ACSR Dog Conductore |
| 45 | ACSR Rabbit Conductore |
| 46 | ACSR Wesal Conductor |
| 47 | Cable AL. 3X300 sq.mm XLPE 11KV |
| 48 | Cable jointing kit out door 11 kV 185 mm² |
| 49 | Disc Fitting for T&C 45 KN |
| 50 | Disc Insulator T&C 45 KN |
| 51 | Earthing of pole by MS earthing rod of 20x2500mm & 6 SWG Earthing wire Etc |
| 52 | MS T-off Channel 125x65 1300 mm |
| 53 | Extra for stays at angle Location (Stay rod 16x1800mm, Stay wire 5 kg, stayclamp, bolts & nut with grouting) |
| 54 | 3-Phase Distribution box |
| 55 | LT Distribution box |
| 56 | 13 meter ST Pole-SP-70 |
| 57 | 11 meter ST Pole-SP-55 |
| 58 | PCC 11 Mtr Long |
| 59 | PCC Support 8.5 Mtr. Long |
| 60 | Polymeric 11KV Pin Insulator |
| 61 | Polymeric 33KV Pin Insulator |
| 62 | Polymeric 11KV Pin with nut |
| 63 | Stay set Complete |
| 64 | Provinding And Installation/Fixing of the Following Decentralised Material With All the Accessories (as per resspo norms) |
| 65 | Aluminium Binding wire-6 SWG/ 6 mm dia |
| 66 | Aluminium paint |
| 67 | Barbed wire GI |
| 68 | Bolt & Nuts for shackel insulator |
| 69 | Bolts & Nuts all sizes (LS) |
| 70 | Cable laying along with cost of digging bricks & sand (LS) |
| 71 | Cable Route marker |
| 72 | Concreting of Stay |
| 73 | Concreting of supports (0.268cu.m./Pole) |
| 74 | Connecting lead 1x16 Sq mm |
| 75 | Danger board with clamp for 11 kV |
| 76 | Dead end clamp with I hook |
| 77 | Digging & laying of 11 KV Cable (Double ckt) in trench with sand & brick and back filling |
| 78 | Earth wire clamps for PCC pole |
| 79 | F-bracket for 11 KV with nut and bolt |
| 80 | G.I pipe 6 inch \\" |
| 81 | Holding Clamp |
| 82 | Cross Arm holding clamp with nut and bolt |
| 83 | LT STP Clamp |
| 84 | Clamp for 33 KV \\"V\\" Type Cross Arm with nut and bolt |
| 85 | F-bracket for 11 KV with nut and bolt |
| 86 | Laying of HDPE Pipe PE-80, PN-6, DN-200mm dia Pipe for laying of 11KV, 3x300Sq.mm, XLPECable with HDD (trenchless) method including cable laying for Road crossing (If required) |
| 87 | Laying of 11 KV Cable in Air |
| 88 | LT Piercing connector 95 Sq.mm |
| 89 | LT pole Clamp with nuts & bolts for PCC pole. |
| 90 | LT Shackel Insulatore 100x115 mm |
| 91 | LT Shackel Strip with bolt & Nut for LT section pole |
| 92 | M.S. Angle Iron 65x65x6mm (4300 mm bracing) |
| 93 | Making of J/kit |
| 94 | Number plates |
| 95 | Eye Hokk |
| 96 | Nut Bolt and washer all sizes |
| 97 | PG clamps |
| 98 | Red oxide paint |
| 99 | Aluminum Paint |
| 100 | Stone pad 300x300x75 mm |
| 101 | sundry Items(L.s) |
| 102 | Suspension clamp with I hook |
| 103 | Top Channel 100x50x6 mm, 2400 mm long |
| 104 | Top channel 125x65mm (3200 mm) |
| 105 | Provinding And Installation/Fixing of the Following Decentralised Material With All the Accessories (as per resspo norms) |
| 106 | ACSR Dog Conductore old & used scrap |
| 107 | ACSR Wesal Conductore old & used scrap |
| 108 | AB Conductor 3x120 sqmm |
| 109 | STP 9 Mtr. |
| 110 | 11 KV Pin |
| 111 | AB Cable (Jurjer As Scrap) |
| 112 | G.I wire scrap |
| 113 | ST pole 11 meter old & used(05 No.) Please Enable Macros to View BoQ information |