| 1 | Dismantling timber scantlings in fillet, rail, posts, rafter, purlins etc under 40 sq. cm in section, in any position as in framed work etc complete all as specified and as directed |
| 2 | Dismantling wrought iron or mild steel work of any description not otherwise provided for etc complete all as specified and as directed |
| 3 | Demolition of cement concrete (un reinforced) in ground floors and paving not exc 15 cm thick (below or above ground level) complete all as specified and as directed. |
| 4 | Taking down cement plaster of any description hacking for key or raking out joint on old brick work/stone/concrete surface etc complete all as specified and as directed |
| 5 | Taking down chowkhats or frames with shutters (without taking off shutter from frames) not exc. 1.5 sqm each etc complete all as specified and as directed |
| 6 | Taking down chowkhats or frames with shutters (without taking off shutter from frames) exc. 1.5 Sqm but n exc 4.0 Sqm each and refixing in the same opening and making good of disturb portion etc complete all as specified and as directed |
| 7 | Taking down shutter of any description area exc 1.00 Sqm but not exc 2.00 sqm each etc complete all as specified and as directed |
| 8 | Taking down chowkhats or frames with shutters (without taking off shutter from frames) exc. 1.50 Sqm but n exc 4.0 Sqm each etc complete all as specified and as directed |
| 9 | Hacking out old Broken glass (Any thickness) size, quality of descriptin from wooden/steel frame etc compelete all as specified and as directed |
| 10 | M&L for 75 mm thick cement concrete type D- 2, 1:4:8 (40mm graded stone aggregate) as in sub base of flooing etc complete all as specified and as directed |
| 11 | M&L for 25 mm thick Cement concrete type B-0,1:2:4 (12.5mm graded stone aggregate) as in levelling course of flooing etc complete all as specified and as directed |
| 12 | M & L for Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 15 mm thick screed bed in CM 1:6 incl dismantling floor, hearth or wall tiling etc complete all as specified and as directed |
| 13 | All as per item No 12 above but as in skirting / dado incl backing coat 10 mm thick in CM 1:3 incl dismantling floor, hearth or wall tiling etc complete all as specified and as directed |
| 14 | M & L for Virified Ceramic tiles (Dark Shade /Duble charged / Ultra Charged) 8 to 9 mm thick (square / rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to incl 15 mm thick screed bed in CM 1:6 incl dismantling floor, hearth or wall tiling etc complete all as specified and as directed |
| 15 | All as per item No 14 above but as in skirting / dado incl backing coat 10 mm thick in CM 1:3 incl dismantling floor, hearth or wall tiling etc complete all as specified and as directed |
| 16 | M&L for 20mm thick granite Granite stone slab (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite slab including grinding the edges half round and polishing incl 15 mm thick screed bed in CM 1:6 incl demolition of stone slab (Laid bedded and pointed in any cement) etc complete all as specified and as directed |
| 17 | M&L for machine presssd pre-cast concrete interlocking coloured paving Block of glass fibre reinfoced glossy finished vibro compacted any shape and size confirming to IS-15658-2006 of 60 mm thick, M-35 grade to match with grey cement and pigment incl 50 mm thick M Sand cushioning incl demolition of stone slab (Laid bedded and pointed in any mortar) etc complete all as specified and as directed |
| 18 | M&L for Pre-polished Chequered cement concrete tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry with grey cement and pigment in floors including screed bed in CM 1:4 incl demolition of stone slab (Laid bedded and pointed in any mortar) complete all as specified and as directed. |
| 19 | M&L for 75 mm thick PCC 1:3:6, type C-1, using 20 mm graded aggregates as in plinth protection, hardstanding etc, finished even and smooth without using extra cement complete all as specified including joints filling with sealing compound Grade \\"A\\" complete all as specified and directed. |
| 20 | M&L Pre-cast Cement concrete Type 1:3:6 using (20 mm graded stone aggregates) with solid blocks, exc 10 cm in width and setting in CM 1:6 incl demolition of brick Work / Stone Masonry/PCC block masonry built in cement mortar of any description all as specified and directed. |
| 21 | M&L for rendering for ceiling 5 mm thick in CM 1:3 on fair faces of brick work or concrete surface finished even and smooth without using extra cement etc complete all as specified and as directed |
| 22 | M&L for rendering 10 mm thick in CM (1:6) on fair faces of brick work or concrete / Stone masonry surface finsihed even and smooth (without using extra cement) etc complete all as specified and as directed |
| 23 | M&L for rendering 15 mm thick in CM (1:4) on other than fair faces of brick work or concrete/stone masonry surface finsihed even and smooth (without using extra cement) mixed with water proofing compound etc complete all as specified and as directed Notes : WPC shall be measured and paid seperately |
| 24 | Supply only liquid water proofing compound |
| 25 | M&L for preparing new plastered surface of ceiling and applying Three coat of white wash etc complete all as specified and as directed |
| 26 | M&L preparing of new plastered surface of walls and applying two coat of oil bound distemper white or tinted over a coat of primer over 1mm thick wall care putty complete all as specified and directed |
| 27 | M&L preparing newly plastered surface of wall and applying two coat of cement base paint over a coat of primer etc complete all as specified and as directed Notes : WPC shall be measured and paid seperately |
| 28 | M&L applying a coat of 1mm thick wall care putty over plaster surface to prepare the surface even and smooth as per manufacture instruction complete all as specified and as directed. |
| 29 | M&L Preparation of old surfaces including brooming down with steel wire brushing scrapping down soot’s, moulds, moss and efflorescence, salts, treating oil and greasy spots etc on wall surfaces and applying two coat of oil bound distemper white or tinted all as specified & as directed. |
| 30 | Material & Labour for preparation of old wall surface applying one coat of 100% Premium acrylic exterior emulsion paint with silicone additives of required shade additives @ 1.43 litre/ 10 sqm . |
| 31 | M&L Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 etc complete all as specified and as directed |
| 32 | S&F Aluminium anodised (powder coated) Three track sliding window frame with shutters with 2 nos glazed and one wire gauzed shutter, (Frame shall be 92x 31.75 x1.5mm, shutter section shall not be less than0.55kg/RM) including all necessary joining cleats, hold fast, rubber gasket, snap beading and locking arrangements fixed with screws to wall etc. with glazing including 5 mm thick tinted glass using rubber gasket and stainless steel wire cloth of 0.36 mm dia & average width of aperture 1.40mm with staple or suitable fillets wire mesh fitted with screws and washers etc complete all as specified and as directed. |
| 33 | S&F Powder Coated aluminium frame for doors, windows ventilators with one or more rebates including joining cleat for fixing etc. complete shall as specified and as directed |
| 34 | S&F Powder Coated aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and as directed Note: - Particle Board & Glass shall be measured and paid separately under respective items. |
| 35 | S&F 35mm thick flush door shutter solid core construction with decorative choice lamination both sides of shutter, kiln seasoned and chemically pressure treated complete all as specified and as directed |
| 36 | S&F in repairs door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg with alumnium die cost body etc complete all as specified and as directed |
| 37 | S&F in repairs Aluminium 4 lever Mortice lock, vertical type, size 100 mm, fixed in any type of door incl cutting, reveting, fixing etc complete at any description and in any position etc complete all as specified and as directed |
| 38 | S&F aluminium alloy 250mm anodised sliding door bolts with hasp, staple (bolt type) & fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast - aluminium alloy and fixed. |
| 39 | S&F 200mm long aluminium anodised tower bolt of extruded section etc complete all as specified and as directed |
| 40 | S&F 100 mm Long stainless steel butt hinges, Medium weight, and fixed etc complete all as specified and as directed |
| 41 | S&F 150 mm long aluminium handle, cast type, anodised etc complete all as specified and as directed |
| 42 | S&F 150 mm long Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor etc complete all as specified and as directed |
| 43 | S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples etc complete all as specified and as directed ' |
| 44 | S&F 4mm thick Figured glass, pin head type and glazing with oil putty in squares in not. exc 0.5 sq.m in each pane etc omplete all as specified and as directed |
| 45 | S&F 5.5mm thick tinted sheet glass and glazing with oil putty in squares exc 0.5 sq. m in each pane etc complete all as specified and as directed |
| 46 | S&F 4mm thick sheet Glass, Ordinary qulatity and glazing with oil putty in squares in not. exc 0.5 sq.m in each pane etc omplete all as specified and as directed |
| 47 | S&F 9 mm prelaminated particle board, exterior grade, with both side decorative choice lamination & fixed with screws in Door / Partiton work etc omplete all as specified and as directed |
| 48 | Repair to existing aluminium door incl taking down shutter of any size and description incl repair to pivot, handle, hinges,spring, minor adjustment if required and make it smooth and functional and operational etc omplete all as specified and as directed Notes : Particle Board, Glass, Door closer/ floor door spring, lock, handle, hinges, door stopper etc will be measured and paid separtely under relevent item. |
| 49 | S&F in repair 12 mm thick Toughned glass as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes required incl all fixing arrangements, Hinzes, Handles,locking arrangements etc complete all as specified and as directed . |
| 50 | S&F in repairs double action floor springs, hydraulically regulated made up of min 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover governing pivot made of brass other parts made of mild steel heave duty and fixed etc complete all as specified and as directed |
| 51 | M&L Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates confirming to Fe 410 -W (Gde- E- 250) quality-A etc complete all as specified and as directed |
| 52 | S&F Pre-painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 MPA as in roof covering/ cladding to wall, fixed with self tapping screws etc incl dismantling of Asbestos cement (corrugated,semi corrugated, etc.) etc complete all as specified and as directed |
| 53 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 MPA as in ridges / valley to wall, fixed with self tapping screws incl dismantling of Ridges etc complete all as specified and as directed |
| 54 | S&F false ceiling with grid suspended system of size 600X600mm standard section consisting of main runner , cross Tee and wall angle as per mfd instruction / catalogue, ceiling suspended with 3 mm dia GI wire hanger fixed with steel dash fastner, butter fly clips, hold down clips etc (Main corner, cross tee & wall angle of MS galvanized with PPPCGS) incl 4 mm thick HPSC self textured design pre primered non asbestos fibre cement building boards fixed to false ceiling incl dismantling of old false ceiling of any type etc complete all as specified and as directed |
| 55 | S&F 7 to 8 mm hollow profile thickness thick PVC Coloured Sheet (any Shape, coloured, pattern as approved ) suitably placed in false ceiling incl making sunken side corner, design as directed etc incl grid work made of G.I./M.S. as per Mfd Instruction , incl dismantling old ceiling of any pattern etc complete all as specified and as directed (Make - Rajashree/ Magama /Syntax or any other equivalent make as approved by GE) |
| 56 | S&F 7 to 8 mm Hollow Profile thickness, Printed colour PVC sheet (Any size, shape, Texture as approved) in strips & channel feathered at the edges for fixing on Wall cladding / Vertical surface and fixing at site incl grid work made of G.I./M.S. as per Mfd Instruction etc incl dismantling old ceiling of any pattern complete all as specified and as directed (Make - Rajashree/ Magama /Syntax or any other equivalent make as approved by GE) |
| 57 | S&F in repairs stainless steel decorative curtain rod of 25 mm bore (weight not less 400 gms per running meter) incl fancy finale caps cap (02 nos in each curtain rod) etc complete all as specified and as directed |
| 58 | S&F in repair Brass Chromium Plated designer Bracket for curtain rod of dia 25 mm dia made out of SS Flat not less than 20 mm wide 1.50 mm thick and overall length not less than 160 mm fixed with screws min 2 Nos with Rawl Plug of size not less than 50 mm long etc complete all as specified and as directed |
| 59 | M&L for Preparation of new or previously un-treated steel and iron surfaces of any description, over 10 cm in width or girth , not otherwise described and painting with two coats of synthetic enamel paint over a coat of red oxide primer etc complete all as specified and as directed |
| 60 | Taking down carefully aluminium/ copper wiring/power point wiring (light, fan, socket or power) complete including fittings such as switches ceiling roses, regulators, sockets light fittings, fans etc and making good the disturbed surface of walls, ceiling etc incl painting with same colour of the back ground complete all as specified and as directed by Engineer-in-Charge. |
| 61 | Point wiring complete concealed with 1.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl non-metalic rigid PVC conduit medium grade ISI marked incl accessories concelaed type wiring incl GI/ MS branded sunken boxes suitable for normal/modular concealed on walls including plastic/heylam laminated sheet top cover 3 mm thick/modular frame and cover of suitable module fixed with cadmium plated iron screws for housing modular/normal type switches, switch socket outlets, fan regulators etc., incl provision of 1.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.for the following :-One light point controlled by one switch |
| 62 | All as per item No. 61 above but forOne fan point controlled by one switch/regulator |
| 63 | All as per item No. 61 above but forOne light point controlled by 2 way switch |
| 64 | All as per item No. 61 above but forOne 3 pin socket out let 5 Amps on independent board |
| 65 | All as per item No. 61 above but forOne bell/buzzer point controlled by bell push |
| 66 | All as per item No. 61 above but forOne 3 pin socket out let 5 A on same board |
| 67 | Point wiring complete surface type with 1.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl non-metalic rigid PVC conduit medium grade ISI marked incl accessories surface type wiring incl GI/ MS branded sunken boxes suitable for normal / modular concealed on walls including plastic / heylam laminated sheet top cover 3 mm thick/modular frame and cover of suitable module fixed with cadmium plated iron screws for housing modular/normal type switches, switch socket outlets, fan regulators etc., incl provision of 1.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.for the following :-One light point controlled by one switch |
| 68 | All as per item No. 67 above but forOne fan point controlled by one switch/regulator |
| 69 | All as per item No. 67 above but forOne light point controlled by 2 way switch |
| 70 | All as per item No. 67 above but forOne 3 pin socket out let 5 Amps on independent board |
| 71 | All as per item No. 67 above but forOne bell/buzzer point controlled by bell push |
| 72 | All as per item No. 67 above but forOne 3 pin socket out let 5 A on same board |
| 73 | All as per item No. 67 but concealed wiring drawn through existing PVC conduit.One light point controlled by one switch |
| 74 | All as per item No. 73 above but forOne fan/Exhaust point controlled by one switch/regulator |
| 75 | All as per item No. 73 above but forOne light point controlled by 2 way switch |
| 76 | All as per item No. 73 above but forOne 3 pin socket out let 5 Amps on independent board |
| 77 | All as per item No. 73 above but forOne bell/buzzer point controlled by bell push |
| 78 | All as per item No. 73 above but forOne 3 pin socket out let 5 A on same board |
| 79 | Point wiring complete with 2.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through non-metalic existing PVC conduit medium density ISI marked incl accessories surface type run on walls/ ceiling incl MS terminal boxes fabricated with 1.6 mm thick GI/MS sheet surface mounted/ concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 2.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed. |
| 80 | Point wiring complete with 1.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl PVC Casing & Caping ISI marked incl accessories surface type wiring incl 1.6 mm thick GI/MS sunken boxes concealed on walls including laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 1.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.for the following One light point controlled by one switch |
| 81 | All as per item No. 80 above but forOne fan point controlled by one switch/regulator |
| 82 | All as per item No. 80 above but forOne light point controlled by 2 way switch |
| 83 | All as per item No. 80 above but forOne 3 pin socket out let 5 Amps on independent board |
| 84 | All as per item No. 80 above but forOne bell/buzzer point controlled by bell push |
| 85 | All as per item No. 80 above but forOne 3 pin socket out let 5 A on same board |
| 86 | Point wiring complete with 2.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl non-metalic PVC conduit medium density ISI marked incl accessories concealed type run on walls/ ceiling incl GI/MS terminal boxes fabricated with 1.6 mm thick MS sheet concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 2.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed. |
| 87 | Point wiring complete with 2.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl PVC casing caping ISI marked incl incl accessories surface type wiring run on walls/ ceiling incl GI/MS terminal boxes fabricated with 1.6 mm thick MS sheet concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 2.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.Note for Item No 86 to 87 :-(i) The earth wire for the points in the same circuit can be looped from point to point(ii) Earth wire shall be taken inside the conduit(iii) Cost of terminal box is deemed to be included in the item rate quoted for point wiring(iv) Cost of a circuit of any length of cable from DB to any switch/ socket board to be included in point wiring. (v) Cost of cutting chases for conduits and making good to walls, in case of recessed or concealed conduit wiring will be paid separately in other items. |
| 88 | S&F LED batten suitable for indoor applications 20 Watts, 4 feet with extruded aluminium housing & integrated LED channel complete with all accessories all as specified and directed. |
| 89 | S&F LED batten suitable for indoor applications 10 Watts, 2 feet with polycarbonate housing & integrated LED channel with white arcylic cover complete with all accessories all as specified and directed. |
| 90 | S&F LED luminaries, round / square type 18 watt Surface / Recess mounted rimless round / square downlight. Modulded in engineering plastic bst in clas high lumen output & wider distribution complete with all accessories as specified and directed. |
| 91 | S&F 2' x 2' Recess mounted LED Luminaire 36 Watts white powder coated CRCA housing with LEDs seamless front frame with flate white high transmission arcylic cover complete with all accessories all as specified and directed. |
| 92 | S&F Decorative, wall mounting ,champagne gold finish fixture with plastic body suitable for 9 watt LED lamp B22 base all as specified and directed by Engineer -in-Charge. |
| 93 | Supply and Fix Modular switch 1 way 6A,1 module |
| 94 | Supply and fix Modular switch 1 way 16A, 1 module |
| 95 | Supply and fix Modular switch 2 way 6A,1 module |
| 96 | Supply and Fix Modular Bell push 6A 1 module |
| 97 | Supply and fix modular Socket, 6A - 2/3 pin combined 2 module |
| 98 | Supply and fix modular Socket 6A/16A - 2/3 pin combined 2 module, |
| 99 | Supply and fix modular type Fan step regulator, 120W - 2 module |
| 100 | S&F of of Switch piano flush button single pole two way 5 Amps all as specified and as directed. |
| 101 | S&F of Angle holder PVC/polycarbonate type all as specified and as directed |
| 102 | S&F of switch piano flush type single pole one way 5 Amps |
| 103 | S&F of switch socket combination 5 pin 2 in 1, 5 A Flush type all as specified and as directed |
| 104 | S&F of switch socket combination 2 in 1, 3 pin 5 and 15 Amps flush type universal all as specified and as directed |
| 105 | S&F of bell push flush type 5A all as specified and as directed . |
| 106 | S&Fin repair of MCB SPN 240 volts 32/40 Amps complete all as specified and as directed |
| 107 | S&F in repair of MCB single pole 240 volts 10/16/20/32 Amps complete all as specified and as directed |
| 108 | S&F in repair of MCB TPN 415 volts, 10KA 'C' curve 63 Amps complete all as specified and as directed |
| 109 | S&F in repair of MCB TPN 415 volts, 10KA 'C' curve 100 Amps complete all as specified and as directed |
| 110 | S&F in repair of MCB DB SPN 4 way double door type 240 volts with 200 Amps rated busbar as specified and as directed. |
| 111 | S&F in repair of MCB DB SPN 8 way double door type 240 volts with 200 Amps rated busbar as specified and as directed. |
| 112 | S&F in repair of MCB DB TPN 4 way with double door type 415 volts with 200 Amps rated busbar for housing MCBs as specified and as directed. |
| 113 | S&F in repair of ceiling rose, surface bakelite type 65 x 50 mm, 2 to 3 terminals all as specified and as directed |
| 114 | S&F in repair of stepped type electronic fan regulator flush Switch/socket type all as specified and as directed |
| 115 | S&F in repair of Ding Dong bell AC 230 volts single pole. |
| 116 | Removing of old existing and provision of new sub main wiring 1100 volts grade multistranded FRLS copper conductors, two runs of single core 6 Sqmm along with 6 Sqm PVC insulated single core multistranded copper conductor cable as earth continuity conductor run along with PVC conduit all as specified and as directed |
| 117 | Removing of old existing and provision of new sub main wiring 1100 volts grade multistranded FRLS copper conductors, two runs of single core 4 Sqmm along with 4 Sqm PVC insulated single core multistranded copper conductor cable as earth continuity conductor run along with PVC conduit all as specified and as directed |
| 118 | M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to galvanized earth lead wire 4 mm dia as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I 2010 and as specified or indicated and testing on completion incl earth work and excavation in any type of soil PCC (1:3:6) type C1 chamber, pre cost slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia MS bars reinforced at 10 cm centre to centre both ways incl funnel with watering pipe wire mesh and lugs, incl test point complete all as specified and as directed including dismantaling and taking down old Earthing plates. |
| 119 | Supply and fixing in repair 30 W LED bldg security light fitting with pressure die cast housing along with prismatic polycarbonate difuser with IP 66 protection including taking out old fittings. |
| 120 | S&Fin repair of Bracket made out of GI tubing medium grade 25 mm bore , approx length 1.5 m long including MS clamps made out of MS flat iron 25 x 6 mm , nuts, bolts, washers etc and including before fixing applying two coats of aluminum paint over a coat of red oxide primer including removing the old existing GI bracket from bldg complete all as specified and directed. |
| 121 | M & L excavation in trenches in hard/dense soil not exc 1.5 mtr wide and not exc 1.5 mtr in depth for laying of cables on trenchs etc complete all as specified and as directed. |
| 122 | M & L for returning, filling in trenches incl spreading leveling watering and well ramming in layers with hard/dense soil not exc 25 cm thick in each layer complete as specified and as directed |
| 123 | M & L for removing excavated soil to a distance not exc 1.5 mtr above the starting point complete all as specified and as directed |
| 124 | M & L for sand cushioning with a layer of M-sand 23 cm thick under and above the cable complete all as specified and as directed |
| 125 | S & L sub class burnt bricks for cable protection complete as specified as directed |
| 126 | S&L cable XLPE insulated screened PVC bedded galvanised steel strip or wire armored, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor connected with suitable legs including neccessary roadcrossing if applicable and taking out the existing unserviceable cable for following size :-2 C x 10 Sqmm |
| 127 | All as per item No. 126 above but for4 C x 16 Sqmm |
| 128 | All as per item No. 126 above but for3.5 C x 25 Sqmm |
| 129 | M&L for GI tubing light grade 40mm dia with all accessories for cable protection fixed on poles / bldgs / road and laid in trenches incl necessary MS clamps, bolts and nuts etc all as specified and as directed. |
| 130 | S&F in repair Bulk Head Fitting suitable for indoor application of 10 watt, including electrical connecion from ceiling rose with 3 core 1.5 sqmm sheathed wire all as directed. |
| 131 | S&F in repair LED Bulb suitable for indoor application of 9 watt, to fit in Angle Holder or Decorative wall light fixture all as directed. |
| 132 | S&F in replacement PVC Fresh air fan of 200 mm sweep 1200/1400 RPM with louver complete including necessary core cutting arrangement for installation all as specified and directed. |
| 133 | Supply and fix in repaironly capacitor 2.5 Mfd suitable for ceiling / exhaust fans complete all as specified and as directed. |
| 134 | Supply and fix in repair heating element of 2 KW (Triangular / rectunglar / hexagonal type) rating including rubber washers all as specified & as directed. |
| 135 | Supply and fix in repair Thermostat suitable for 25/50 Ltrs capacity. |
| 136 | Dismantling /opening the ceiling fan of 1200 mm sweep of any make and type, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and reassembling complete all as specified and as directed. Please Enable Macros to View BoQ information |