| 1 | SCHEDULE 'A' PART-I: B/R WORKS |
| 2 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc. complete all as specified and directed |
| 3 | Demolition and breaking up including removing salt glazed stoneware pipe 150mm bore (internal) with concrete bedding and haunching and removing material from premises complete including necessary earth work as required all as specified and directed. |
| 4 | M&L for Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft/loose soil. Complete all as specified and directed |
| 5 | M&L Demolition of Concrete in ground floors andpavings n exc 15 cm thickness(below or above ground level all as specified and directed. |
| 6 | M&L for PCC 1:4:8 type D2 as in foundations, filling and mass concrete. |
| 7 | M&L for cement concrete bed to drain pipe 150mm bore (Internal) in cement concrete (1:3:6) type C-2 with using 40mm graded crushed stone aggregate including packing under and haunching against the sides of pipes after they are laid and tested all complete all as specified and directed. |
| 8 | M&L for cement concrete bed to drain pipe 200mm bore (Internal) in cement concrete (1:3:6) type C-2 with using 40mm graded crushed stone aggregate including packing under and haunching against the sides of pipes after they are laid and tested all complete all as specified and directed. |
| 9 | M&L for Reinforced concrete pipes 150mm dia (internal), class NP3, laid and jointed complete with collars as in sewage lines laid in trenches and jointed complete |
| 10 | M&L for Reinforced concrete pipes 200mm dia (internal), class NP3, laid and jointed complete with collars as in sewage lines laid in trenches and jointed complete |
| 11 | M&L for Pre cast cement concrete Type B1 1:2:4 (20 mm graded aggregate) block masonary with solid blocks, exc 10 cm in width and setting in cement mortar 1:6 complete all as specified and as directed. |
| 12 | M&L for rendering cement plaster in CM 1:4, 15 mm thick in fair faces of brick work or concrete surfaces finishing the surface even & smooth without using extra cement complete all as specified and as directed. |
| 13 | M&L PCC (1:2:4) type B-1, using 20 mm graded stone aggregate as in surface channels and drains etc. |
| 14 | M& for Providing, cement concrete , in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed |
| 15 | Demolition of reinforced concrete work in of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) complete all as specified and as directed. |
| 16 | M&L for Providing precast cement concrete Type B-1 (1:2:4) 20mm graded stone aggregate as landings, cover slabs (for man holes,open drain etc.) chullah hoods, chajjas, water troughs,mangers, shelves and similar articles with plain faces etc. and setting in mortar CM 1:6 complete with joints to match all as specified and directed. |
| 17 | M & L for TMT reinforcement 10 mm dia and over cut to length bent to shape including cranking, hooking etc binding with mild steel wire not less than 0.90 mm dia (annealed) all as directed complete. |
| 18 | M &L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface all as directed complete. |
| 19 | M & L for 100 mm thick, PCC 1:4:8, Type D-2, using 40mm graded stone aggregate as in Floors / Hard standing etc, surface of concrete roads, pavements finished by brooming complete all as specified and as directed. |
| 20 | M & L for 100 mm thick, PCC 1:2:4, Type B-2, using 40mm graded stone aggregate as in Floors / Hard standing etc, surface of concrete roads, pavements finished by brooming complete all as specified and as directed. |
| 21 | Taking down SWR pipes including all fittings any size and pattern.complete all as specified and directed |
| 22 | S&F PVC (SWR) pipes 75mm dia pipe single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed |
| 23 | S&F PVC (SWR) pipes 110 mm dia pipe single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed |
| 24 | S&F 75 mm dia., PVC Bends (any Radius) with access door complete all as specified and directed |
| 25 | S&F 110 mm dia., PVC Bends (any Radius) with access door complete all as specified and directed |
| 26 | M&L for Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. soft/loose soil. Complete all as specified and directed |
| 27 | M&L for Removing excavated material exc. 250 m but n exc. 500 m and depositing where directed Complete all as specified and directed |
| 28 | Taking out liquid content / solid content from sump/ septic tank(100 user septic tank)/ filter bed/ soakage well by sewage sucker tanker & cleaning through including disposal of liquiid / soil content out of the defence land complete all as specified and directed. |
| 29 | Cleaning of manhole of any description & size and exceeding 1.5 M in depth including lifting up and removing sludge & accumulated solid/semi solid sludge and any other foreign material with mechanically & washing down with water for smooth functioning of sewage line all as directed, sludge obtained from cleaning shall be removed outside MD land complete all as directed |
| 30 | Cleaning of blocked sewage line of any dia by rodding from one manhole to next manhole and washing through in fresh water including removing all sludge, tree roots from the sewage lines and disposed off properly outside the MD land complete all as directed. |
| 31 | M&L for 100 users Septic tanks including exc in any type of soil,returning filling and removal of surplus soil at a distance not exc 250Mtr. Contractor to be followed all the details of septic tank as per TD CEDD/86/TD/13/A Sheet No 1/2 & 2/2. |
| 32 | M&L for 100 users Soakage pit including exc in any type of Soil, returning filling and removal of surplus soil at a distance not exc 250Mtr. Contractor to be followed all the details of Soakage pit as per CE(Navy)Visakhapatnam TD Drg No-318(S) Sheet No 1/1. Please Enable Macros to View BoQ information |