Indian Tenders

Tender Notice

TDR 55644893
Tendering Authority Public Works Department
Tender No 510/15Mg Dt-12-05-2026
Tender ID 2026_CEAGR_1152138_1
Tender Brief Tender For Construction Of Examination Hall (Room) (7.40 X 8.00M) At Collectrate C Us Agra
City Agra
State Uttar Pradesh
Document Fees INR 854 /-
EMD INR 192000.0 /-
Tender Value INR 19.17 Lakhs /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Construction Of Examination Hall (Room) (7.40 X 8.00M) At Collectrate C Us Agra

Key Dates

Publish Date 23-05-2026
Last Date of Bid Submission 28-05-2026
Tender Opening Date 28-05-2026

Contact Information

Company Name Public Works Department
Contact Person Executive Engineer, CD-Building, PWD, Agra
Address Executive Engineer, CD-Building, PWD, Agra

BOQ Items

Name of Work:- Construction of Examination Hall (Room) (7.40 x 8.00m) at Collectrate C us Agra
Sl. No. Item Description
1Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil.(DSR-2.8.1)
2Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. (DSR-2.25)
3Anti-Termite Treatment Pre-Construction Anti-Termite Treatment of the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area(DSR-SOR-Ch-8 Sl-1)
4Anti-Termite Treatment Pre-Construction Anti-Termite Treatment of the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured)(DSR-SOR-Ch-8 Sl-2)
5Anti-Termite Treatment Pre-Construction Anti-Termite Treatment of the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface(DSR-SOR-Ch-8 Sl-3)
6Anti-Termite Treatment Pre-Construction Anti-Termite Treatment of the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface(DSR-SOR-Ch-8 Sl-4)
7Anti-Termite Treatment Pre-Construction Anti-Termite Treatment the soil along with external perimeter of building at the rate of 2.5 litres of emulsion per square metre of the perimeter wall(DSR-SOR-Ch-8 Sl-5)
81:4:8 (1 Cement : 4 coarse sand (zone-lll) derived from natural sources : 8 graded stone aggregate 40 mm nominalsize derived from natural sources) (DSR-4.1.8)
9Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content,the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth levelConcrete of M25 grade with minimum cement content of 330 kg /cum.RCC in Footing, Plinth Beam, RCC in Column upto plinth(DSR-5.33.1.1)
10Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.(DSR-5.22.6)
11Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand)(DSR-6.1.2)
12Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-lll) derived from natural sources : 4 graded stone aggregate 12.5 mm nominal size derived from natural sources)(DSR-4.1)
13Providing & applying a coat of residual petroleum bitumen of grade VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with piece of cloth lightly soaked in kerosene oil.(DSR-4.13)
14Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete for all lift.(DSR-2.25,a)
15Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.(DSR-2.27)
1615 mm cement plaster on rough side of single or half brick wall of mix:1:4 (1 cement: 4 coarse sand)(DSR-13.5.1)
17Centering and shuttering including strutting, propping etc. and removal of form for all heights: Foundations, footings, bases of columns, etc. for mass concrete.(DSR-5.9.1)
18Centering and shuttering including strutting, propping etc. and removal of form for all heights: Columns,Pillars, Piers, Abutments, Posts and Struts.(DSR-5.9.6)
19Centering and shuttering including strutting, propping etc. and removal of form for all heights: Lintels, beams, plinth beams, girders, bressumers and cantilevers.(DSR-5.9.5)
20Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in:Cement mortar 1:6 (1 cement : 6 coarse sand)(DSR-6.4.2)
21Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.:Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works above plinth level upto floor V level5.33.2.1 Concrete of M25 grade with minimum cement content of 330 kg /cum(DSR-5.33.2.1)
22Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part |!) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws(DSR-9.21.1)
23Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (DSR-9.23)
24Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)(DSR-10.15.1)
25Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works(DSR-10.25.2)
26Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chase(DSR-12.21.1 )
27Providing and fixing glass strips in joints of terrazo/ cement concrete floors.40 mm wide and 4 mm thick(DSR-11.13.1)
28Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete.With 12 mm mild steel U beading(DSR-9.135.2)
29Providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws 35 mm thick shutters Second class teak wood.(DSR-9.134.1.2.1)
30Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.(DSR-5.22.6)
3115 mm cement plaster on rough side of single or half brick wall of mix1:6 (1 cement: 6 coarse sand)(DSR-13.5.2)
3212 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand)(DSR-13.4.2)
33Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mmto 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mmheight including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. “All above operations to be done in order and as directed and specified by the Engineer-in-Charge”:With average thickness of 120 mm and minimum thickness at khurra as 65 mm(DSR-22.7.1)
34Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm(DSR-11.41.2)
35Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to |.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete..Size of Tile 600x600 mm(DSR-11.46.2)
36Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate(DSR-11.3.1)
37Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :13.62.1 Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture (Steel)/(wooden painting)(DSR-13.62.1)
38Applying priming coat.With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works(DSR-13.50.3)
39Applying priming one coat:13.50.2 With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood(DSR-13.50.2)
40Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm)(DSR-13.47.1)
41Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre(DSR-13.41.1)
426mm thick plaster in 1:3 cement & coarse sand on ceiling and soffits of stairs upto floor two level. (DSR-13.16)
43Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.(DSR-13.8)
44Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes(DSR-10.30.1)
45Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :300x16 mm(DSR-9.96.1)
46Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :250x10 mm(DSR-9.97.2)
47Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :125 mm(DSR-9.100.1)
48Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper.(DSR-9.101.2)
49Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.(DSR-5.3)
50Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.(DSR-9.84)
51Centering and shuttering including strutting, propping etc. and removal of form for all heights:Columns,Pillars, Piers, Abutments, Posts and Struts.(DSR-5.9.6)
52Centering and shuttering including strutting, propping etc. and removal of form for all heights:Lintels, beams, plinth beams, girders, bressumers and cantilevers.(DSR-5.9.5)
53Centering and shuttering including strutting, propping etc. and removal of form for all heights:Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick(DSR-5.9.20)
54Providing and fixing stainless steel fancy handle of approved make fixed with SS screws etc. complete as per direction of Engineer-in-charge.200 mm(DSR-9.17)
55Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10 mm gap for thermal expansion. a) 110 mm Shoe(DSR-12.42.6)
56Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.(DSR-12.44)
57Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes.a) 110mm diameter(DSR-12.41.2)
58Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.a) 110mm (DSR-12.43.2)
59Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand)(DSR-6.1.1)
6015 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand)(DSR-13.8.1) Note - 1- Rates are inclusive of all taxes but excluding GST which shall be paid extra as applicable 2- Labour cess @ 1% will be deducted from contractor's bill at the time of payment Please Enable Macros to View BoQ information

Other Detail

Information Source https://etender.up.nic.in
Download FileName File Description File Size
Download 147c0718-d3dc-4847-9416-5ce8155c3393.html Tender Documents 0 KB
Download BOQ_2158285.xls Tender Documents 0 KB
Download T1_1E_ExaminationHallReTender.pdf Tender Documents 0 KB
Download Tendernotice_1 (18).pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.