Indian Tenders

Tender Notice

TDR 55644542
Tendering Authority Delhi Development Authority
Tender No 05/EE (E)/ELD-10/DDA/2026-27
Tender ID 2026_DDA_909985_1
Tender Brief Tender For Running Maintenanc & Operation Of Fire Fighting System,Fire Alarm System & Pa System And Cctv System, Epabx System & Iei At Community Hall In Different Pockets I.E A,B-1,B-2,C & D & Dda Project Office (Loknayakpuram ) Bakkarwala As Per In
City Delhi
State Delhi
Document Fees Refer document
EMD INR 21022.0 /-
Tender Value INR 10.51 Lakhs /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Running Maintenanc & Operation Of Fire Fighting System,Fire Alarm System & Pa System And Cctv System, Epabx System & Iei At Community Hall In Different Pockets I.E A,B-1,B-2,C & D & Dda Project Office (Loknayakpuram ) Bakkarwala As Per Inventory Attached. I) Wireman-1 No. 52 Days (Once In A Week And Whenever Is Required) Ii) Khallasi - 1 No. 52 Days (Once In A Week And Whenever Is Required). , Running Maintenance & Operation Of Sewage Pump Sets And Cctv System At Sewage Pump House As Per Inventory,Terms And Conditions Attached. I) Wireman-1 No. 52 Days (Once In A Week And Whenever Is Required) Ii) Khallasi - 1 No. 52 Days (Once In A Week And Whenever Is Required). Iii) Pump Operator Gr-Ii- 2 Nos. ( 6:00 Am To 2:00 Pm And 2:00 Pm To 10:00 Pm And Whenever Is Required) , Running,Operation & Maintenance Of Existing Street Lights On Upto 12 Mtr Height Poles Complete With Feeder Pillers,Switchgears,Pole Boxes, Copper Wires & Distribution Cables Etc In Various Locations As Per Inventory With Tower And Wagon Whenever Required . I) Wireman -1 No. 104 Days (Twice In A Week And Whenever Is Required) Ii) Khallasi - 1 No. 104 Days (Twice In A Week And Whenever Is Required). , Repairing Of 75 Hp Sewage Pump Set I/C Supply & Replacement Of Following Worn Out Part I/C Dismantling & Reconnection Complete Etc As Required. special repair Of Of Shaft Sleeve-1No. special repair Of Of Ball Bearing -2 No. special repair Of Of S.S Shaft -1 No special repair Of Of Impleller Nut -1 No special repair Of Of Gland Dori -1 No , Dismantling And Rewinding The Existing Burntout 3 Phase 3Hp Submersible Pump Set In The Existing Borewell I/C Dismantling The Existing Delivery Line,Valves Etc And Lowering The Same I/C Connections, Testing Etc Complete With Followings As Required. (I)Motor Winding Kit-1No. (Ii)Bearing Bush-4No(Iii)Water Seal-2No.(Iv)E.P Stage Bowl(V)E.P.Impeller , Led Flood Light, Powder Coated Pressure Die Cast Aluminium(System Lumen Efficacy ≥120 And 135 Lm/Watt).Supplying,Installation, Testing & Commissioning Of Flood Light, Powder Coated Pressure Die Cast Aluminium Body With Built In Or Separatedriver As Per The Requirement With Driver Efficiency 85%, Input Voltage: Input Voltage: 140-270 Volt Ac, Frequency 50/60 Hz,Operating Temp Range -5 °C To 50 °C, Internal Surge Protection Of 5 Kv L,N,E As Per Iec 61000-4-5, Driver Efficiency 85%,Thd 10% As Periec 61000-3-2, P. F.≥0.95, Ip-66,Ik-10, Cri ≥70, Under Voltage And Over Voltage Protection, Emi-Emc As Per Cispr-15, Lenses For Beam Angle 30 Deg-120Deg As Per The Application And The Project Requirement, Suitable Tilt Able Fitting, Life Time (Led, Driver & Electricalcircuitry) Of Minimum 50000 Burning Hours With 70% Of Initial Lumen Maintained Till Life Ends As Per Lm80 Extrapolation Ies Tm-21-11Report, Cct 3000°K / 4000°K / 5700°K /6500°K (As Per Ansi Bin),Sdcm(Standard Deviation Colour Matching) 5, Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Relevant Bis Standard Complete In All Respect I/C External Connections With 1.5 Sq.Mm Frls/Hffr, Pvc Insulated Copperconductor Single Core Cable And Earthing Etc. As Required With Minimum 5 Year Oem Warranty. System Lumen Efficacy ≥120 And 135 Lm/Watt Output . Lm79 & Lm80 Test Report And All Testing Required For Led Fixtures As Per Bis Shall Be Submitted.. Shape Size And Cct Shall Be As Approved By Engineer-In-Charge As Per Requirement.(Thermal Management: Heat Sink Of Aluminium Housing Such That Led Junction Temperature Shall Not Rise Above 90°C).A) 200 Watt (Dsr.2025 8.15.5) , Led Street Light Fixture, Powder Coated Pressure Die Cast Aluminium Body (System Lumen Efficacy ≥120 135 Lm/Watt) Supplying, Installation, Testing & Commissioning Of Street Light Led Fixture Powder Coated Pressure Die Cast Aluminium Body With Driver As Per The Requirement With Driver Efficiency 85%, Input Voltage: 140-270 Volt Ac, Frequency 50/60 Hz, Operating Temp Range -5 °C To 50 °C, Internal Surge Protection Of 5 Kv L,N,E As Per Iec 61000-4-5, Driver Efficiency 85%,Thd 10% As Per Iec 61000-3-2, P. F.≥0.95, Ip-66,Ik-10, Cri ≥70, Under Voltage And Over Voltage Protection, Emi-Emc As Per Cispr 15 , Lenses For Beam Angle As Per Iesna Type I/Ii/Iii As Per The Width Of The Road And The Project Requirement., Suitable To Fit In Up To 65Mm Dia Pipe, Life Time (Led,Driver & Electrical Circuitry) Of Minimum 50000 Burning Hours With70% Of Initial Lumen Maintained Till Life Ends As Per Lm80extrapolation Ies Tm-21-11 Report, Cct 3000°K / 4000°K / 5700°K/6500°K (As Per Ansi Bin), Sdcm(Standard Deviation Colourmatching) 5, Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Relevant Bis Standard Complete In All Respect I/C External Connections With 1.5 Sq Mm Frls/Hffr, Pvc Insulated Copper Conductor Single Core Cable Andearthing Etc. As Required With Minimum 5 Year Oem Warranty. System Lumen Efficacy ≥120 135 Lm/Watt Output . Lm79 & Lm80 Test Reportand All Testing Required For Led Fixtures As Per Bis Shall Besubmitted. Shape Size And Cct Shall Be As Approved By Engineer-In-Charge As Per Requirement. (Thermal Management: Heat Sink Of Aluminium Housing Such That Led Junction Temperature Shall Not Rise Above 90°C).A)150 Watt (Dsr 2025- 8.13.17) , Supplying,Replacement, Testing & Commissioning Of Led Surface Mounted Batten Light Of Following Body Material And Construction As Per Is : 10322 With Driver (Replaceable) As Per The Requirement With Driver Efficiency 85% ,Operating Voltage Ac 140-270 Volt, Freq 50/60 Hz, Operating Temp Range -15 Deg To 40 Deg Centigrade, Internal Surge Protection Of 2.5 Kv With Short & Open Circuit Protection ,Thd 10% , P. F.≥0.95, Ip20, Cri 80, Flicker Free, (Flicker Should Be Below 5 %), Life Time (Led,Driver & Electrical Circuitary), Of Minimum 50000 Burning Hours With , 70% Of Initial Lumen Maintained Till Life Ends, Cct 3000°K / 4000°K / 5700°K /6000°K/6500°K (As Per Ansi Bin), Sdcm(Standard Deviation Color Matching) 3, Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Relevant Bis Standard And Trade Mark Certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. Complete In All Respect I/C Connections With 1.5 Sq Mm Frls, Pvc Insulated Copper Conductor Single Core Cable And Earthing Etc. As Required With Minimum 5 Year Oem Warranty. System Lumen Efficacy ≥120 135 Lm/Watt Output . Lm79 & Lm80 Test Report From Nabl Lab For All Testing Required For Led Fixtures As Per Bis Shall Be Submitted. Shape Size And Cct Shall Be As Approved By Engineer-In-Charge As Per Requirement. (Thermal Management: Heat Sink Of Aluminum Housing Such That Led Junction Temperature Shall Not Rise Above 90°C). Powder Coated Die Cast / Extruded Aluminium Body (Thickness ≥ 1.20 Mm).A) 18 To 22 Watt , Supply, Replacement , Testing And Commissioning Of 1200 Mm Sweep,Bee 5 Star Rated, Ceiling Fan With Brush Less Direct Current (Bldc) Motor, Class Of Insulation: B, 3 Nos. Blades, 30 Cm Long Down Rod, 2Nos. Canopies, Shackle Kit, Safety Rope, Copper Winding, Power Factor Not Less Than 0.9, Service Value (Cmm/W) Minimum 6.85,Air Delivery Minimum 215 Cmm,350 Rpm (Tolerance As Per Is : 374-2019), Thd Less Than 10%, Remote Or Electronic Regulator Unit For Speed Control And All Remaining Accessories Including Safety Pin, Nut Bolts, Washers, Temperature Rise=75 Degree C (Max.), Insulation Resistance More Than 2 Mega Ohm,Suitable For 230 V, 50 Hz, Single Phase Ac Supply, Earthing Etc.Complete As Required. , Supplying And Drawing Of Following Size Of Frls Pvc Insulated Copper Conductor Single Core Cable In The Existing Surface/Recessed Steel/Pvc Conduit Etc. As Required. (A) 3 X1.5 Sq. Mm , (B) 3X4 Sq.Mm , Supply & Replacement Of Following Piano Type Switch / Socket On The Existing Switch Box/ Cover I/C Connection Etc. As Reqd.(Dsr 2025 Item 1431 Pg-320) (A) 5/6 Amps Switch , (B) 15/16 Amp. Switch , (D) 6 Pin 15/16 annual periodical maintenance Socket Outlet , Providing, Laying And Replacement Of M25 Reinforced Cement Concrete Foundation Of Size 750 Mm (L) X 1000 Mm (D) And 750 Mm (W) After Removing The 12 M Pole I/C Excavation Of Earth, Providing Cutting, Bending And Placing In Position Reinforcement Of Cold Twisted Bar Of 12 Mm Dia. 900 Mm Long (Approx.) - Atleast 20 Nos. And Reinforcement Ring Of Cold Twisted Bar Of 10 Mm Dia. 4000 Mm Long (Approx.)- Atleast 6 Nos. (With 150 Mm Spacing) I/C Supplying Of 4 Nos. M-24 X 400 Mm Long (150 Mm Top Threaded & 250 Mm Top Galvanized Portion) M.S Foundation Bolt (En 8-Grade) With 3 Nos. Nuts And 2 Nos. Washer, Bolt Along With 2 Nos. Templates/Anchor Plate Of Size 320 Mm X 320 Mm X 4 Mm Thick Having 4 Nos. 24 Mm Dia. Holes To Match With Pcd Of Poles Base Plate With Positioning Of Foundation Bolts And Providing 65 Mm (Od) 2 Nos. Dwc Pipe For Cable Entry And Exit And Reinstall The Pole With The Help Of Hydra/Crane . , Fabricating ,Providing And Fixing Of M.S Connector Cover On Existing 12M High Pole With Suitable Size Made Out Of 1 Mm Thick M.S Sheet With Kabja From One Side And Another Side By Tight By 2 No.M.S Flat Clamp(1.6 Mm Thick) Nut Bolts I/C Painting With Approved Shade I/C Dismantling The Existing Damaged/Rust Connecter Cover Etc.Complete As Required , Supplying Of Following Size Of Xlpe Insulated / Pvc Sheathed Aluminium Conductor Armourd Power Cable Of 1.1 Kv Grade I/C Making, Connection Testing Etc. Complete As Req. At Site).2C X 25Sq.Mm , Laying Of One Number Pvc Insulated And Pvc Sheathed /Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In Existing Rcc/Hume/Metal Pipe As Required A)Upto 35 Sq.Mm , Supplying And Making Straight Through Joint With Heat Shrinkable Kit Including Ferrules And Other Jointing Materials For Following Size Of Pvc Insulated And Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Reuired . A) 2*25 S.Mm (Dsr Item) , Providing A Motorised Man Lift Crane Suitable Upto 12 Mtr Street Light Poles For Replacement And Rectification Of Street Light Fittings Mounted On 12 Mtr Pole Complete As Required.

Key Dates

Publish Date 23-05-2026
Last Date of Bid Submission 29-05-2026
Tender Opening Date 30-05-2026

Contact Information

Company Name Delhi Development Authority
Contact Person EE(E)/ELD-10/DDA
Address EE(E)/ELD-10/DDA, B2B Janakpuri, ND-58.

BOQ Items

Name of Work:-
Sl. No. Item Description
1Running Maintenanc & Operation of fire fighting system,fire alarm system & PA system and CCTV System, EPABX System & IEI at community hall in different pockets i.e A,B-1,B-2,C & D & DDA Project office (Loknayakpuram ) Bakkarwala as per inventory attached. i) Wireman-1 No. 52 days (once in a week and whenever is required)ii) Khallasi - 1 No. 52 days (once in a week and whenever is required).
2Running Maintenance & Operation of sewage pump sets and CCTV system at Sewage Pump House as per inventory,terms and conditions attached.i) Wireman-1 No. 52 days (once in a week and whenever is required)ii) Khallasi - 1 No. 52 days (once in a week and whenever is required). iii) Pump operator GR-II- 2 Nos. ( 6:00 AM to 2:00 PM and 2:00 PM to 10:00 PM and whenever is required)
3Running,operation & Maintenance of existing street lights on upto 12 mtr height poles complete with feeder pillers,switchgears,pole boxes, copper wires & distribution cables etc in various locations as per inventory with tower and wagon whenever required .i) Wireman -1 No. 104 days (twice in a week and whenever is required)ii) Khallasi - 1 No. 104 days (twice in a week and whenever is required).
4Repairing of 75 HP Sewage Pump Set i/c Supply & Replacement of following worn out part i/c dismantling & reconnection complete etc as required. S/R of of shaft Sleeve-1No. S/R of of Ball Bearing -2 No. S/R of of S.S Shaft -1 No S/R of of Impleller Nut -1 No S/R of of Gland dori -1 No
5Dismantling and rewinding the existing burntout 3 phase 3HP submersible pump set in the existing borewell i/c dismantling the existing delivery line,valves etc and lowering the same i/c connections, testing etc complete with followings as required.(i)Motor winding kit-1No. (ii)Bearing Bush-4No(iii)water seal-2No.(iv)E.P stage bowl(v)E.P.Impeller
6LED Flood Light, powder coated pressure die cast aluminium(System lumen efficacy ≥120 and <135 lm/Watt).Supplying,Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separatedriver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 Hz,Operating temp range -5 °C to 50 °C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as perIEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI ≥70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver & electricalcircuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copperconductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement.(Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).a) 200 watt (DSR.2025 8.15.5)
7LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥120 <135 lm/Watt)Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 °C to 50 °C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI ≥70, under voltage and over voltage protection, EMI-EMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with70% of initial Lumen maintained till life ends as per LM80extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation ColourMatching) <5, Maximum power consumption should not more thanthe specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable andearthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test reportand all testing required for LED fixtures as per BIS shall besubmitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).a)150 Watt(DSR 2025- 8.13.17)
8Supplying,Replacement, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm).a) 18 to 22 watt
9Supply, replacement , Testing and Commissioning of 1200 mm sweep,BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85,Air delivery minimum 215 CMM,350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm,suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc.complete as required.
10Supplying and Drawing of following size of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit etc. as required. (a) 3 x1.5 sq. mm
11(b) 3x4 sq.mm
12Supply & replacement of following piano type switch / socket on the existing switch box/ cover i/c connection etc. as reqd.(DSR 2025 item 1431 Pg-320)(a) 5/6 Amps switch
13(b) 15/16 Amp. Switch
14(d) 6 pin 15/16 Amp socket outlet
15Providing, laying and replacement of M25 reinforced cement concrete foundation of size 750 mm (L) x 1000 mm (D) and 750 mm (W) after removing the 12 m pole i/c excavation of earth, providing cutting, bending and placing in position reinforcement of cold twisted bar of 12 mm dia. 900 mm long (approx.) – atleast 20 Nos. and reinforcement ring of cold twisted bar of 10 mm dia. 4000 mm long (approx.)- atleast 6 Nos. (with 150 mm spacing) i/c supplying of 4 Nos. M-24 x 400 mm long (150 mm top threaded & 250 mm top galvanized portion) M.S foundation bolt (EN 8-grade) with 3 Nos. nuts and 2 Nos. washer, bolt along with 2 Nos. templates/Anchor plate of size 320 mm x 320 mm x 4 mm thick having 4 Nos. 24 mm dia. holes to match with PCD of poles base plate with positioning of foundation bolts and providing 65 mm (OD) 2 Nos. DWC pipe for cable entry and exit and reinstall the pole with the help of hydra/crane .
16Fabricating ,Providing and fixing of M.S connector cover on existing 12m high pole with suitable size made out of 1 mm thick M.S sheet with kabja from one side and another side by tight by 2 no.M.S flat clamp(1.6 mm thick) nut bolts i/c painting with approved shade i/c dismantling the existing damaged/rust connecter cover etc.complete as required
17Supplying of following size of XLPE insulated / PVC sheathed aluminium Conductor armourd power cable of 1.1 KV grade i/c making, connection testing etc. complete as req. at site).2C x 25sq.mm
18Laying of one number PVC insulated and PVC sheathed /XLPE power cable of 1.1 KV grade of following size in existing RCC/HUME/METAL pipe as required a)upto 35 sq.mm
19Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as reuired . A) 2*25 s.mm (DSR item)
20Providing a motorised man lift crane suitable upto 12 mtr street light poles for replacement and rectification of street light fittings mounted on 12 mtr pole complete as required. Please Enable Macros to View BoQ information

Other Detail

Information Source https://eprocure.gov.in/eprocure/app
Download FileName File Description File Size
Download BOQ_956397.xls Tender Documents 0 KB
Download dcaf31e2-1391-4b4e-8367-660528451727.html Tender Documents 0 KB
Download Tendernotice_1.pdf Tender Documents 0 KB
Download Tendernotice_2.pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.