Indian Tenders

Tender Notice

TDR 55644529
Tendering Authority Food Corporation Of India
Tender No UP/EM/04/ARMO/2026-27
Tender ID 2026_FCI_909971_1
Tender Brief Tender For Name Of Work : Rewiring & Repairing Of Power Supply Of Proposed Divisional Office At Fsd Chandari-I Under Do Kanpur.
City Kanpur Nagar
State Uttar Pradesh
Document Fees Refer document
EMD INR 22909.0 /-
Tender Value INR 11.45 Lakhs /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Name Of Work : Rewiring & Repairing Of Power Supply Of Proposed Divisional Office At Fsd Chandari-I Under Do Kanpur.

Key Dates

Publish Date 23-05-2026
Last Date of Bid Submission 03-06-2026
Tender Opening Date 04-06-2026

Contact Information

Company Name Food Corporation Of India
Contact Person AGM EM
Address FCI RO Lucknow

BOQ Items

Name of Work:- Name of Work : Rewiring & repairing of power supply of proposed Divisional Office at FSD Chandari-I under DO Kanpur.
Sl. No. Item Description
1Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
23 X 10 sq. mm
33 X 4 sq. mm
43 X 2.5 sq. mm
5Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (Confoming to relevent BIS/IS standard or equivalent)a) 25mm
6Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator) 4 way (4 + 12), Double door
7Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)12 way , Double door
8Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
9Single pole
10Double pole
11Supplying and fixing of following rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple Pole & Neutral 63A
12LED Batten light 18-22 watt (System lumen efficacy ≥105 <120lm/Watt).Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P.F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. completein all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape sizeand CCT shall be as approved by Engineer-inCharge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Powder coated die cast /Extruded aluminiumBody (Thickness > 1.20 mm)
13Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required conforming to relevant BIS/IS codes.
14Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (Confoming to relevent BIS/IS standard or equivalent)
155/6 amps switch
1615/16 amps switch
173 pin 5/6 socket outlet
186 pin 15/16 socket outlet
19Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc.as required. (Confoming to relevent BIS/IS standard or equivalent)
20Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. (Confoming to relevent BIS/IS standard or equivalent)
2112 Module (200mmX150mm)
226 Module (200mmX75mm)
23Supply of 1200 mm sweep ceiling fan suitable for 230 V ±10%, 50 Hz single-phase AC supply, complete with energy-efficient motor (as per BEE norms), aerodynamically balanced aluminium blades, double ball bearing assembly for smooth and silent operation, minimum air delivery of 210 CMM, and rated speed of about 300–320 RPM. The fan shall be provided with powder-coated finish, rust-resistant body, thermal overload protection, and shall conform to relevant IS standards (IS: 374). The item includes supply of down-rod, shackle assembly, canopy, terminal block, and all standard accessories, complete in all respects as approved by the Engineer-in-Charge.
24Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
25Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required Group A
2636 Watt LED Panel light 2x2 ft. (System lumen efficacy ≥105<120 lm/Watt)Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80,UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housingsuch that LED junction temperature shall not rise above 90°C).Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)
27Supply of PVC insulated PVC sheathed cable of 1.1KV grade armoured Underground aluminum conductor cable as reqd confirming to IS –7098 part I with up to date amendments) of the following size as per direction in charge.
283.5X50 sqmm
294X16 sqmm
30Supplying and fixing of light class G.I. pipe of 50 mm dia.(nominal) 3metres length along the pole for protection of underground cable as required.(conforming to IS-1239 part 1 (2004) or equivalent)
31Laying of one number PVC insulated and PVC sheathed / XLPEpower cable of 1.1KV grade of following size in the existing RCC/ HUME/ METAL/HDPE pipe as required.
32Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
33Supply and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (conforming to IS 12943 (1990) or equivalent)
343.5X50 sqmm (35mm)
354X16 sqmm (28mm)
36Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required. (Confoming to relevent BIS/IS standard or equivalent)
37Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. (Confoming to relevent BIS/IS standard or equivalent) Please Enable Macros to View BoQ information

Other Detail

Information Source https://eprocure.gov.in/eprocure/app
Download FileName File Description File Size
Download 6c624be1-28b3-4d69-9e6f-04634d6fecf1.html Tender Documents 0 KB
Download BOQ_956385.xls Tender Documents 0 KB
Download MTF_Chandari.pdf Tender Documents 0 KB
Download Tendernotice_1.pdf Tender Documents 0 KB
Disclaimer :