Indian Tenders

Tender Notice

TDR 55644466
Tendering Authority National Hydroelectric Power Corporation Limited
Tender No NH-LPS-CDIV/126/2025-LTPC/1106
Tender ID 2026_NHPC_908995_1
Tender Brief Tender For Renovation Of Leimatak Hospital At Loktak Power Station, Manipur.
City Churachandpur
State Manipur
Document Fees INR 1180 /-
EMD INR 166000.0 /-
Tender Value INR 82.80 Lakhs /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Renovation Of Leimatak Hospital At Loktak Power Station, Manipur.

Key Dates

Publish Date 22-05-2026
Last Date of Bid Submission 12-06-2026
Tender Opening Date 17-06-2026

Contact Information

Company Name National Hydroelectric Power Corporation Limited
Contact Person GSM (E and C), Contracts Division
Address Office of the GSM (E and C), Contracts Division, NHPC Limited, Loktak Power Station, PO-Loktak, Komkeirap, Distt-Churachandpur, Manipur-795124

BOQ Items

Name of Work:- Renovation of Leimatak Hospital at Loktak Power Station, Manipur.
Sl. No. Item Description
1Demolishing brick work manually/ by Mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in charge. In Cement mortar.
2Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
3Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area 3 sq. metres and below.
4Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles above 10 mm and upto 25 mm.
5Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
6Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
7Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including disposal of excavated earth upto 50 m and lift upto 1.5 m, disposed soil to be levelled and neatly dressed: All Kinds of soil.
8Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level: 1:3:6 (1 Cement: 3 coarse sand : 6 graded stone aggregate 40 mm nominal size).
9Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size).
10Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level : 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size).
11Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete Above plinth level. Thermo-Mechanically Treated bars.
12Centering and shuttering including strutting, propping etc. and removal of form for: Lintels, beams, plinth beams, girders, bressumers and cantilevers.
13Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement: 6coarse sand : 12 graded stone aggregate 20mm nominal size) at plinth level with : Cement mortar 1:6 (1 cement: 6 coarse sand).
14Brickwork with 1st class common burnt clay F.P.S. (non-modular) bricks in superstructure above plinth level upto floor V level in all shapes and sizes in :Cement mortar 1:4 (1 cement: 4 coarse sand).
15Half brick masonry with 1st class common burnt clay F.P.S.(non-modular) bricks in foundation and plinth in: Cement mortar 1 : 3(1 cement : 3 coarse sand).
16Honey-comb brick work 10/11.4 cm thick with 1st class common burnt clay F.P.S. (non-modular) bricks in superstructure above plinth level and upto floor V level in cement mortar 1: 4 ( 1 cement : 4 coarse sand).
1712 mm cement plaster of mix: 1:4 (1 cement : 4 fine sand).
186 mm cement plaster of mix: 1:3 ( 1 cement :3 fine sand).
19Neat cement punning.
20Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
21Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface: Water thinnable cement primer.
22Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coat.
23Finishing walls with Acrylic Smooth exterior paint of required shade: New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20kg/ 10 sqm).
24Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1.4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, levelling system and rubber mallet for placing the tiles gently and easily. Glazed vitrified tiles Matt/Antiskid finish of size 600 x 600 mm.
25Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
26Providing and fixing 18mm thick gang saw cut mirror polished (premoulded and prepolished) machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing moulding and polishing to edge to give high gloss finish etc. complete at all levels. Granite of any colour and shade. Area of slab over 0.50 sqm.
27Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia and length (hold fast lugs or dash fastener shall be paid for separately : local best quality Tolhao wood.
28Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows including ISI marked M.S butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. Local best quality Tolhao wood. 35 mm thick shutters.
29Finishing walls with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture.
30Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required EPDM rubber/ Neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleatangle, Aluminium snap beading for glazing / panelling, C.P. brass /stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and panelling to be paid for separately):For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately).
31Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. With EPDM rubber/neoprene gasket etc. complete as per the architectural drawings and the direction of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): with float glass panes of 5.50 mm thickness.
32Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade I Type II, in panelling fixed in aluminium doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side.
33Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete 250x10 mm each.
34Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 125 mm each.
35Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :250x16 mm.
36Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, screws etc. to suit shutter thickness complete.
37Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete:
38Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an undercoat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture.
39Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets: 20 mm dia (heavy type).
40Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
41Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in charge. The sheet shall be fixed using self-drilling /self-tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required with Precoated galvanised iron profile sheets 0.35 mm thick.
42U-PVC pipe (working pressure 4kg/cm2) Single socketed pipe 110 mm dia.
43U-PVC pipe (working pressure 4kg/cm2) Single socketed pipe 75 mm dia.
44Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 25 mm nominal outer dia Pipes.
45Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the wall etc.15 mm nominal outer dia Pipes.
46Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings &C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid.
47Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required: White Vitreous China Wash basin size 630x450 mm with a pair of15 mm C.P. brass pillar taps.
48Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink Without drain board :610x510 mm bowl depth 200 mm.
49Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 1500 X 450 mm.
50C.P. Brass angle valve 15 mm.
51Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :15 mm nominal bore.
52Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 100 mm diameter.
53Providing and fixing C.P health faucet 15 mm dia ( two in one type - Pillar tap & health faucet) complete with all fittings.
54Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge (a) 15 mm nominal dia.
55Flexible (coil shaped) PVC waste pipe for sink and wash basin 32 mm dia with length not less than 700 mm i/c PVC waste fittings.
56Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
57Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms.
58PTMT grating 100 mm dia.
59Grading roof for water proofing treatment with Cement mortar 1:4 ( 1cement: 4 coarse sand).
60Supplying and applying bituminous solution primer on roof and or wall surface at 0.24 litre per sqm.
61Providing and laying factory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. 50 mm thick.
62Making soak pit 2.5 m diameter 3.0-metre-deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non-modular) bricks of class designation 7.5.
63Providing and fixing at all height false ceiling including providing and fixing of frame work made of special sections, power pressed from M.S. sheet and galvanised with zinc coating of 120 gms/ sqm (both sided inclusive) as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5mm diax50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x25x0.55mm of required length with nuts and bolts of required size and the other end of the angle hanger fixed with intermediate G.I. channels 45x15x0.9mm running at the spacing of 1200mm centre to centre, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction, including fixing perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre, with 25mm long drive-all screws @ 230mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cut-outs made with frame of perimeter channels suitably fixed, all complete as per drawings, and specification and direction of the Engineer in Charge but excluding the cost of painting with :12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- Part I.
64Dry stone pitching 22.5 cm thick including supply of stones and preparing surface complete.
65Point wiring in PVC conduit with modular type switch: - Wiring for light point / Fan point / Exhaust Fan point/ Call bell point with 1.5 mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with modular type switch, modular plate suitable size G.I box and earthing the point with 1.5 mm2 FR PVC insulated copper conductor single core cable etc. as required. Group B.
66Wiring for circuit/Sub-main wiring along with earthing wire with (the following sizes) of FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit etc. as reqd. (a) 2x1.5mm2 + 1x1.5mm2 earth wire
67Wiring for circuit/Sub-main wiring along with earthing wire with (the following sizes) of FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit etc. as reqd. (b) 2x2.5mm2 + 1x2.5mm2 earth wire.
68Wiring for circuit/Sub-main wiring along with earthing wire with (the following sizes) of FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit etc. as reqd. (c) 2x10mm2 + 1x10mm2 earth wire.
69Providing and Fixing (following capacity TP&N) dis-connector fuse switch unit inside the existing cubicle panel board with ISI marks HRC fuses including drilling holes in the cubicle panel board, making connection as reqd. 200 amp TP.
70Supplying and Fixing Bus bar chamber with 4 strips copper bus bar of length 600 mm suitable for 200 amp capacities complete with all accessories i/c connection earthing the body etc. as reqd.
71Supplying and Fixing (following way) single /double pole neutral, sheet steel MCCB distribution board, 240 V on surface/ recessed complete with tinned copper bus bar neutral bus bar, earth bar, din bar, detachable gland plate, interconnection, phosphatized and powder painted including earthing etc as reqd. (but without MCB/RCCB/Isolator) 12 way single door.
72Supplying and Fixing (following rating ) double pole 240 V isolator in the existing MCBDB complete with connection, testing and commissioning as reqd. 63 amp.
73Supplying and Fixing 5 amp to 32 amp rating 230V \\"B\\" series MCB for lighting and other load of (following pole) in the existing MCBDB complete with connection testing and commissioning etc. as reqd. Single Pole.
74S/F single pole blanking plate in the existing MCBDB complete etc.
75S/F (following size/ modules) G.I. Box along with modular base and cover plate for modular switch in recess as reqd. (a) 4 module (125mm x 75mm).
76S/F (following size/ modules) G.I. Box along with modular base and cover plate for modular switch in recess as reqd. (b) 6 module (200mm x 75mm).
77S/F (following size/ modules) G.I. Box along with modular base and cover plate for modular switch in recess as reqd. (c) 8 module (125mm x 125mm).
78S/F (following size/ modules) G.I. Box along with modular base and cover plate for modular switch in recess as reqd. (d) 12 module (200mm x 150mm).
79S/F following size/ modules, G.I. Box along with modular base and cover plate for moldular switch in recess as reqd. 3 module (100mm x 75mm).
80Supplying and Fixing (following modular type switch/socket on the existing modular plate and switch box i/c connection but excluding modular plate etc as reqd. (a) 5/6 amp switch.
81Supplying and Fixing (following modular type switch/socket on the existing modular plate and switch box i/c connection but excluding modular plate etc as reqd. (b) 15/16 amp switch.
82Supplying and Fixing (following modular type switch/socket on the existing modular plate and switch box i/c connection but excluding modular plate etc as reqd. (c) 3 pin 5/6 amp socket outlet.
83Supplying and Fixing (following modular type switch/socket on the existing modular plate and switch box i/c connection but excluding modular plate etc as reqd. (d) Each 20 284.4 375.408 7508.16.
84Supplying and Fixing modular type blanking plate on existing modular plate and switch box excluding modular plate as reqd.
85Wiring for light point/power plug with 2x4mm2 FRLC PVC insulated copper conductor single core cable in surface/recessed PVC conduit along with 1 no. 4mm2 FRLC PVC insulated copper conductor single core cable for loop earthing etc. as reqd.
86S/F call bell /buzzer suitable for DC/AC single phase 230V complete as reqd.
87S/F bell push modular type complete as reqd.
88S/F brass batten/angle holder i/c connection etc. as reqd.
89S/F 3 pin 5 amp ceiling rose on the existing junction box/wooden block i/c connection etc. as reqd.
90Installation testing and commissioning of pre wired fluorescent fitting/compact fluorescent fitting of all types complete with all accessories and tube etc. directly on ceiling/wall i/c connection with 1.5mm2 FR PVC insulated copper conductor S/cofre cable and earthing etc. as reqd.
91Supplying and fixing BLDC ceiling Fan of 1200 mm sweep complete with all accessories i/c connection etc. as required.
92Installation, Testing, commissioning of Ceiling Fan/Fan Bracket with Hook : Installation testing an d commissioning of ceiling fan i/c wiring down rod of standard length (up to 30 cm) with 1.5sqmm FR PVC insulated copper conductor single core cable etc. as reqd.
93Supplying and fixing of MS Bracket with hook for ceiling Fan (to be fattened in angle iron above the false ceiling)
94Supplying & fixing stepped type electronic fan regulator on the existing modular plate switch box i/c connection but excluding modular plate etc. as reqd.
95S/F 305 mm sweep exhaust fan complete with all accessories i/c connection etc as reqd.
96S/F 15 Ltr water heater (Geyser) A.C. 2 KW vertical type with all accessories i/c connection etc as reqd.
97Earthing with G.I. earth plate 600mmx600mmx6mm thick i/c accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal or coke and salt as reqd.
98Providing and fixing 25mmx5mm G.I strip in 40mm dia G.I pile from earth electrode including connection with GI nut, bolt, spring, washer excavation and re-filling etc. as reqd. Mtrs. 35 706 706 24710.
99Supplying and fixing of 12 Watt LED Lamp 2 pin i/c connection etc as required .
100Supplying and fixing of 18 Watt LED surface Panel Lamp round shape (White) i/c connection etc as required
101Supplying and fixing of 70 Watt LED Street Light i/c connection etc as required Each 4 6411.82 6411.82 25647.28.
102Add EPF @ 3.25%
103Add CESS @ 1%
104Add GST @ 18.00% Please Enable Macros to View BoQ information

Other Detail

Information Source https://eprocure.gov.in/eprocure/app
Download FileName File Description File Size
Download 27fa318b-ca4a-443b-a738-efa6ef92dd93.html Tender Documents 0 KB
Download BOQ_956234.xls Tender Documents 0 KB
Download tenderdocument.pdf Tender Documents 0 KB
Download Tendernotice_1.pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.