| 1 | Supply and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 2 | 185 sq. mm |
| 3 | 300 sq. mm |
| 4 | 400 sq. mm |
| 5 | Supply and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. |
| 6 | 185 sq. mm |
| 7 | 300 sq. mm |
| 8 | 400 sq. mm |
| 9 | Supply and Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. |
| 10 | 185 sq. mm |
| 11 | 300 sq. mm |
| 12 | 400 sq. mm |
| 13 | Supply and Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. |
| 14 | 185 sq. mm |
| 15 | 300 sq. mm |
| 16 | 400 sq. mm |
| 17 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 18 | 3½ X 185 sq. mm (57mm) |
| 19 | 3½ X 300 sq. mm (70mm) |
| 20 | 3½ X 400 sq. mm (82mm) |
| 21 | Supply and making straight through cable jointing for following size of 3.5 core, XLPE aluminum conductor cable of 1.1 kV grade as required. |
| 22 | 185/300/400 sq. mm |
| 23 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required |
| 24 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required |
| 25 | Dismantling of over head lines comprising of aluminium over head 3 phase conductor(R,Y,B and neutral), G.I. wire, cross arms, insulators etc. as required. |
| 26 | Dismantling of pole/ street light standard/ strut embedded in brick ballast foundation etc. as required. |
| 27 | Supply and laying of 4C X 10 sq. mm armoured aluminium cable service line to provide the power supply upto user end. Laying of cable through underground/surface/ trench as per site requirement. |
| 28 | Supply and installation of 3 phase energy meter of rating 10A- 63 A( cable termination and sealing included in the meter) . Make: L&T/Genus/Secure |
| 29 | Trimming of tree branches along the LT overhead distribution line/street light by using self man and machinery(involving 2 unskilled and 1 semi skilled labour) |
| 30 | Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. |
| 31 | 63 A TP&N |
| 32 | 100 A TP&N |
| 33 | 125 A TP&N |
| 34 | 160 A TP&N |
| 35 | 200 A/250 A TP&N |
| 36 | 400 A TP&N |
| 37 | Supply and installation of outgoing/incoming Feeder terminal (Busbar) of rating 125A/250A/400A in existing outdoor feeder pillars. |
| 38 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . |
| 39 | 4 way (4 + 12), Double door |
| 40 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. |
| 41 | 125 A,36KA,FPMCCB |
| 42 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 43 | Triple pole and neutral |
| 44 | Supplying, Installation, Testing & Commissioning of Flood Light in substation premises , powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI>70, under voltage and over voltage protection,EMI-EMC as per CISPR-15, lenses for beamangle 30 deg-120deg as per the application and the project requirement. Make: Phillips/Wipro/Crompton/Polycab |
| 45 | 150 watt Please Enable Macros to View BoQ information |