| 1 | Supply, fabrication, installation in repairs and commissioning of a retro-reflective glow sign board for Complaint cell and electrical installations with respective rating and Area, complete in all respects and as specified and directed by the Engineer-in-Charge. The work comprises providing a double-sided sign board of size 2000 mm × 1500 mm made of 2 mm thick Aluminium Composite Panel with 2 mm aluminium skin, incorporating High-Intensity Prismatic Type IV retro-reflective sheeting conforming to IRC:67–2012, with a green background and white computerized cut vinyl reflective lettering as approved by the Engineer-in-Charge, designed to reflect light when illuminated by external sources such as vehicle headlights. The sign board shall be supported on two 40 mm diameter mild steel (MS) pipes of 3 mm thickness conforming to IS:1239, fixed at a height of 3.5 m above ground level, complete with base plates of size 150 mm × 150 mm × 6 mm and anchor bolts. The MS members shall be finished with two coats of anti-corrosive primer followed by two coats of synthetic enamel paint in green colour. The work includes providing PCC M15 (1:2:4) foundations for each pole measuring 0.40 m × 0.40 m × 0.60 m, including excavation, reinforcement with four numbers of 8 mm diameter MS bars conforming to IS:432, cantering, formwork, backfilling, and curing. The sign board shall be securely fixed using stainless steel bolts, nuts, and washers (M10) conforming to IS:1367. The job includes all labour, materials, tools, plants, transportation, alignment, levelling, erection, and finishing, complete in accordance with relevant IS standards, IRC specifications, MES practices, and as directed by the Engineer-in-Charge. |
| 2 | M&L in replacement for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area laid in trenches / duct or fixed to wall / passing through pipe on pole with suitable size cable glands, crimping type cable lugs for stranded aluminium conductor of size 4C X 10 Sqmm complete all as specified and directedNote: Excavation, earthwork, returning filling and removal of soil shall be measured and paid separately |
| 3 | All as per item No. 2.00 above but 4 Core X 16 Sqmm |
| 4 | All as per item No. 2.00 above but 4 Core X 25 Sqmm |
| 5 | All as per item No. 2.00 above but 3.5 Core X 35 Sqmm |
| 6 | All as per item No. 2.00 above but 3.5 Core X 50 Sqmm |
| 7 | All as per item No. 2.00 above but 3.5 Core X 70 Sqmm |
| 8 | All as per item No. 2.00 above but 3.5 Core X 95 Sqmm |
| 9 | All as per item No. 2.00 above but 3.5 Core X 120 Sqmm |
| 10 | All as per item No. 2.00 above but 3.5 Core 150 Sqmm |
| 11 | All as per item No. 2.00 above but 3.5 Core 185 Sqmm |
| 12 | All as per item No. 2.00 above but 3.5 Core 240 Sqmm |
| 13 | Taking out and Relaying of LT cable of size 10 Sqmm to 50 Sqmm 2/3.5 core after carrying out necessary Repair such as joining with Epoxy joint and laid with sand Cushioning and brick protection and making connection By using Lugs all as specified and directed by Engr in charge.Note: Earthwork, sand cushioning, and brick protection are deemed to be included in the item rates and shall not be measured separately. LT joints shall be measured under the relevant item. |
| 14 | Taking out and Relaying of LT cable of size 70 sq. mm to 150 Sqmm 3.5 core after carrying out necessary Repair such as joining with Epoxy joint and laid with sand Cushioning and brick protection and making connection By using Lugs all as specified and directed by Engr in charge. Note: Earthwork, sand cushioning, and brick protection are deemed to be included in the item rates and shall not be measured separately. LT joints shall be measured under the relevant item. |
| 15 | Taking out and Relaying of LT cable of size 185 sq. mm to 300 Sqmm 3.5 core after carrying out necessary Repair such as joining with Epoxy joint and laid with sand Cushioning and brick protection and making connection By using Lugs all as specified and directed by Engr in charge. Note: Earthwork, sand cushioning, and brick protection are deemed to be included in the item rates and shall not be measured separately. LT joints shall be measured under the relevant item. |
| 16 | Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth, for foundation of PCC/ Steel pole, laying of cable in trenches etc and getting out in hard / dense soil complete all as specified and directed. |
| 17 | All as per item No. 16.00 above but depth exc 1.5 mtr but not exc 3 mtr. |
| 18 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soils complete all as specified and directed. |
| 19 | Removing excavated material (soils) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 20 | M & L filling riddled earth in trenches for cushioning of laying of cables to the full width of excavated trench 8 cm thick before laying the cable and overall 18 cm, gently punned down, stretching and testing of cable on transformer yard etc complete all as specified and directed.Note :- Thickness of riddle earth cushion after punning down only shall be measured for payment. |
| 21 | M & L brick protection with common burnt brick sub class ‘B’ of size 230 x115 x75 mm for cable protection complete all as directed by Engr-in-charge. |
| 22 | Supplying and fixing in replacement of 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat of Size 4 Sqmm complete all as specified and directed. |
| 23 | Supplying, erecting and fixing in replacement of steel tubular swaged poles with cast iron base plate of size 300mm x 300mm x 6mm, finial taper plug, bolts, nuts & screws for type 410 SP-31 (9.0 mtrs long) including painting with two coats of aluminium paint over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2\\" (inch) wide including taking down old unserviceable PCC poles of any type complete all as specified and directed. Note: Excavation, earth work, PCC in foundation and coping shall be measured and paid separately under relevant item of this schedule |
| 24 | M&L PCC 1:4:8 type D2 using 40 mm graded stone aggregate for filling & foundation of pole & mass complete all as directed |
| 25 | M&L PCC 1:3:6 type C2 using 40 mm graded stone aggregate for filling & foundation of pole & stay complete all as directed |
| 26 | M&L PCC 1:2:4 type B1 using 20 mm graded stone aggregate for coping of pole complete all as directed |
| 27 | Supply & fixing in replacement of automatic street light switch using Nature Switch for automatic switching of street lights based on LUX level of natural light the sensor (nature switch) along with suitable power contactors and MCBs (Input-output) should be enclosed in pole/ wall mountable enclosure made of rust proof, Electric shock proof, termite proof and FR grade SMC junction box (sintex make) conforming to IP 54.the contactor, MCBs and copper circuit wiring (min.10sqmm) should enough to take: three-phase load of 12-15KW; contactor Rating 32Amps; MCB (SPN) Rating 32Amps.Make: Healer Enterprises Model no SWADEEP-02EC12KW3P or equivalent in Seimens and Havells. |
| 28 | Disconnecting and taking out unserviceable MCCB and supply and fixing of new MCCB, 630 A, 50 kA, 4 pole, 415 V, 50 Hz (microprocessor-based release), suitable for existing panel, including necessary mounting arrangement, termination of incoming and outgoing cable connections, setting and calibration, testing for protection and operation, and commissioning, complete with removal of old unserviceable unit, as specified and as directed by the Engineer-in-Charge. |
| 29 | All as per item No. 28.00 but adjustable thermal magnetic type suitable for 400 Amps 36 KA |
| 30 | All as per item No. 28.00 but adjustable thermal magnetic type suitable for 315 Amps 36 KA |
| 31 | All as per item No. 28.00 but adjustable thermal magnetic type suitable for 250 Amps 36 KA |
| 32 | All as per item No. 28.00 but adjustable thermal magnetic type suitable for 200 Amps 36 KA |
| 33 | All as per item No. 28.00 but adjustable thermal magnetic type suitable for 160 Amps 36 KA |
| 34 | All as per item No. 28.00 but adjustable thermal type for 100 Amps 25 KA |
| 35 | All as per item No. 28.00 but electro magnetic type suitable for 63 Amps 16 KA |
| 36 | M & L for cross arms, bracing, supports clamps and back plates fabricated from structural steel section incl nuts, bolts washers, welding, bending cold or hot drilling holes for bolts in any shapes or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint including disconnecting/ taking out old existing unsv cross arms complete all as specified and directed. |
| 37 | Supply and fixing in replacement of lantern of dia 60 CM for fixing of flood light, cap type to be fixed on the top of 9m SP-31 Steel pole, made of MS pipe medium grade dia greater than the top dia of the pole of length 0.35 M supported by MS flat iron of size 50X6 mm 8 nos including two coat of aluminium painting over a coat of red oxide primer complete all as directed |
| 38 | M&L for attending, repair and rectification of external LT electric supply complaints on up to 1100 Volts grade, over head/ underground system alongwith necessary T&P, safety devices as per site requirement for the following type of complaints complete all as specified and directed:- |
| 39 | Replacement of worn out jumpers, jointing and tightening with new ACSR conductor.Note:- Single phase/ two wire or 3 phase/ 4 wire system will be considered as one job for payment purpose. Please Enable Macros to View BoQ information |
| 40 | Replacement of worn out jumpers, jointing and tightening with new ACSR conductor.Note:- Single phase/ two wire or 3 phase/ 4 wire system will be considered as one job for payment purpose. Please Enable Macros to View BoQ information |