| 1 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, complete all as specified and directed. |
| 2 | M & L for application of epoxy bonding primer for old to new concrete bonding (Sikadur-32 LP) as per manufacturer instruction complete all as specified and directed. |
| 3 | M & L for rendering 10mm thick internal surfaces on fair faces of brick or concrete surfaces in cement plaster 1:6 and finished even and smooth (without using extra cement) complete all as specified and directed. |
| 4 | M & L for rendering 15mm thick on fair faces of brick or concrete surfaces in cement plaster 1:4 using WPC 3% by weight of cement (WPC to be measured and paid separately) and finished even and smooth (without using extra cement) complete all as specified and directed. |
| 5 | Supply only liquid l water proofing compound |
| 6 | M & L for two coat of Oil bound distemper over applying a thin layer of 0.50mm thick Birla white putty/JK white wall care putty on wall surfaces including removal of existing treatment and making the surface uniform and smooth complete all as specified and directed. |
| 7 | M & L for preparation of new plastered/decorated wall surfaces and applying two coats of distempering with acrylic distemper over a coat of primer as per manufacturer instruction white or tinted complete all as specified and directed. |
| 8 | M & L for preparation of old decorated surfaces including brooming down or steel wire brushing complete of walls and applying one coat of distempering with acrylic distemper as per manufacturer instruction white or tinted complete all as specified and directed. |
| 9 | M & L for preparation of old decorated surfaces including brooming down or steel wire brushing complete of ceiling and applying one coat of distempering with acrylic distemper as per manufacturer instruction white or tinted complete all as specified and directed. |
| 10 | M & L for preparation of new plastered/decoarated wall surfaces and applying two coats of water proof cement base paint over a coat of primer complete all as specified and directed. |
| 11 | M & L for applying two coats of cement base paint on existing old treated surfaces of walls after preparation of surfaces including brooming down or steel wire brushing complete all as specified and directed. |
| 12 | M & L for applying a coat of cement base paint on existing old treated surfaces of walls after preparation of surfaces including brooming down or steel wire brushing complete all as specified and directed. |
| 13 | M & L for preparation of old plastered or un-plastered surface including brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying two coats of white wash on walls complete all as specified and directed. |
| 14 | M & L for one coat of exterior emulsion paint white or tinted on walls of fascia of roof or chajjas on old decorated prepared plastered/painted surfaces of bldg all as specified and directed. |
| 15 | M & L for one coat of exterior weather proof emulsion red apex paint tinted on walls of fascia of roof or chajjas on old painted surfaces brick, stone, concrete, asbestos cement or plaster on old decorated prepared plastered/painted surfaces of bldg all as specified and directed. |
| 16 | M & L One coat of floor guard paint on floor (Chequered tiles surfaces) including brooming down or steel wire brushing, scrapping down smoke root, moulds, moss and efflorescent salts and trading oil and greasy spots complete all as specified and directed. |
| 17 | M & L for preparation of old painted surfaces of brick,kerb stone, concrete, asbestos cement or plaster of any description, not otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paint (first quality) complete all as specified and directed. |
| 18 | M & L for preparation of old painted steel surfaces of any description, not otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paint (first quality) complete all as specified and directed. |
| 19 | M & L for preparation of old painted wooden surfaces of any description, not otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paint (first quality) complete all as specified and directed. |
| 20 | M&L for one coat of glazed lacquer resin and hardener paint (Polyurathene) incl preparation of surfaces of brick,stone,concrete,asbustose ,cement or plaster surfaces of any description over 10CM girth not otherwise described complete all as specified and directed |
| 21 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed. |
| 22 | M & L for taking down & refixing of Precast cement concrete kerbs stone block of size of each kerb stone exc 0.009 Cum and n exc .020 Cum in road kerbs or mud stops, rounded or chamfered on edges, kneelers, apex stones, bed plates, kerbs including weathering, slightly rounded or chamfered angles and throating incl fixing in cement mortar 1:4 and painting as required on site complete all as specified and directed |
| 23 | Dismantling of machine pressed precast concrete interlocking paver block of any shape any size and laid dry or laid dry and pointed in any mortar complete all as specified and directed. |
| 24 | Re-laying for machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 80/60 mm thickness M-40 Grade with grey cement and no pigment complete all as specified and directed. |
| 25 | M & L for hardcore of broken stone or boulders of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface. |
| 26 | Demolition of cement Concrete(unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete. |
| 27 | M & L for 75 mm thick Plain Cement concrete type C- 2, 1:3:6 (40mm graded stone aggregate) as in sub base. |
| 28 | Sand filling under floors for cushioning of including watering and consolidation |
| 29 | M & L for machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade with grey cement and pigment complete all as specified and directed. |
| 30 | M & L for Providing, cement concrete type B1, 1:2:4 (using 20 mm graded stone aggregate) in cills, steps; seismic and other similar bands, plinth courses copings including necessary form work all as specified and as directed |
| 31 | M & L for filling of gaps/joints between tiles, granites or any cemented work etc with pigment and making the surface good complete all as specified and directed. Supply and laying river bed fine sand in trenches/ ducts 15 cm under cable and 8 cm above the cable for cushioning / protection to cable including spreading, levelling and get thick 18cm after hand punning complete all as specified and directed at site. Please Enable Macros to View BoQ information |