| 1 | Supply, installation, commissioning of Water cooler fully stainless steel, electric driven single phase having approx storage and nominal cooling capacity of 40/80 Ltrs complete all as specified and as directed. |
| 2 | Supply, installation, commis-sioning of Metal Top Deep Freezer single phase 240 volt, 50 Hz of capacity 320 Ltrs complete all as specified and as directed |
| 3 | Supply and install hi wall split AC with indoor/ outdoor unit of Capacity 1.5 Ton complete with cordless remote control unit and dust filter for better indoor air quality with minimum 5 star rating and Efficient & Inverter Split AC with Copper condensor equipped with Indoor/ Outdoor, remote etc. complete all as specified and as directed. |
| 4 | Supply and install hi wall split AC with indoor/outdoor unit of Capacity 2 Ton complete with cordless remote control unit and dust filter for better indoor air quality with minimum 5 star rating and Efficient & Inverter Split AC with Copper condensor equipped with Indoor/ Outdoor, remote etc. complete all as specified and as directed. |
| 5 | Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. |
| 6 | Supply and fix desert cooler electric driven (single phase), having nominal air flow capacity of 5000 CuM per hour (or nearest size). Plastic/ PVC Body |
| 7 | S&F and testing of LT cable 1100 volts grade, XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) ISI Marked with aluminium conductor suitable for earthed system of size 35 sq mm 3.5 core in trenches, on poles and in ducts complete all as specified and directed by Engr in charge. |
| 8 | -- do-- but size 16 sq mm 4 core |
| 9 | -- do-- but size 10 sq mm 4 coreNote for Ser Item No 7 to 9 : Excavation & Earthwork, pipe protection shall be measured and paid seprately under the relevant item of this Schedule. |
| 10 | Excavation in trenches nexc 1.5 mtr in depth and not exceeding 1.5 Mtr wide for laying of cable/pipe etc and getting out in any type of soil complete all as specified nad directed. |
| 11 | Returning filling in trenches excavated soil including spreading levelling watering and well ramming in layers n.exc 25 cm thick each layer as in soil complete all as specified nad directed.. |
| 12 | Removing excavated materials n.exc 50 mtr depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified nad directed. |
| 13 | Supply & laying of HDPE pipe ISI mark of outer dia 50 mm polythylene with smooth internal and profiled external surface for non pressure under ground cable icluding coupler and bends etc complete all as specified and directed by Engineer-in-ChargeMake : Supreme / Infra / Astral/ Prince/ jain irrigation |
| 14 | S&F GI Tubes, of size 50mm dia Medium grade, galvanised, with all fitting, laid in trenches for protection of cable in road / drain crossing complete all as specified and as directed. |
| 15 | Supply, installation,testing and commissioining factory made LT feeder pillar panel CPRI approved, size of panel as per CPRI Specification, double door floor mounted outdoor type, as per IP-65 grade,made out of CRCA sheet 3.15 mm thick of outer body of suitable size with Aluminium bus bar 400 Amps,4 strip,(3 phase & Neutral) complete drilled, insulated with colour coaded insulation tape,mounted on insulators etc with RYB indicater,internal wiring with suitable size of copper wire,panel should be dust proof, vermin proof, powder coated, locking should be screw type, mechanical type, inter locking,should have danger notice for 415 volt, AC, mounted on 50 x 50 x 6 mm angle iron frame having minimum 2 feet ground clearance duly embedded in and including PCC block(1:2:4) type B1 foundation for fixing of panel complete including ternination of all incoming and outgoing cables with suitable size thimbles/lugs and stainless steel glands Nuts & Bolts complete all as specifid and directed.(Main Panel) Note: All MCCB Shall be Thermal and Magnetic adjustable type as per IEC 6047-II(i) Incoming MCCB 4P, 200 Amp, 25 KA, thermal and magnetic adjustable -01 No ( Ics = 100% Icu)(ii) Outgoing -Al bus bar 400 Amps(iii) Outgoing MCCB 4P 63 Amp, 25 KA -04Nos ( Ics = 100% Icu)(iv)Change Over Switch 4 Pole 25 KA 160 Amp -01 Nos(iv) Digital voltmeter & Ammeter with necessary CTs(v) Internal wiring with PVC insulated, multi stranded copper conductor cable, 1100 V grade, IS 694 marked of approriate size but not less than 2.5 sqmm(vi) Phase indicating LED lamps (R-Y-B) -01 set(vii) Spare chamber for MCCBs - 01 Nos |
| 16 | M & L for fabrication of bus bar chamber of size not less than 600 x 600 x450 mm suitable for 415 volts 3 phase 4 wire system, outdoor type, double door, with pedestal mounted, weather and vermin proof fabricated out of 3.15 mm thick MS CRCA sheet with anti corrosive coating & finally epoxy polyster powder coating of flint grey shade including 3 nos. phase indicating lamps, insertion of suitable cable glands for all incoming and out going cable including grouting of panel board 60 cm above & 30 cm below ground level duly supported on 50x50x6mm angle iron frame & welding 45 cm long angle iron legs of size 50x50x6mm on all the four corners embedded in PCC 1:2:4 using 20 mm stone aggregate upto 30 cm depth complete all as specified and directed by Engineer-in-Charge.Incoming MCCB : 63 AMps ,4P,16 KA Busbar Capacity : 100 AMps mounted on DMC/ porcelain insulator support with RYB indicator Outgoing provision of upto 8 cable. |
| 17 | Notes:- For Item No 15 to 161. The Panel Should be approved by CPRI. 2. The rates Quoted shall include for earth work,Plinth protection around the panel apprx 75cm and excavation & earthwork for angle iron frame for foundation of panel board up to 0.50 m below GL in any type of soil and PCC 1:4:8 type D2 filling in foundation. The ground clearance of panel board shall be 0.40 M from GL to the bottom of panel board. |
| 18 | M&L for earthing complete with galvanized steel earth plate electrode of size 60cm X 60 cm X 6 mm buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of plate not less than 1.5 m below the normal ground level connected to GI earth strip 25 x4 mm as earth lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel, protected by GI pipe light grade 40mm bore all as shown on electrical plate No 3 of SSR Part-I 2009, connected to earth test point electrode, PCC pit with RCC cover, funnel with wire mesh, watering pipe 20mm dia protection pipe etc and testing on completion complete all as specified and directed.Note No 1 :- The unit rate shall also include for earth work in hard/dense soil, PCC (1:3:6) type C1 chamber, RCC 1:2:4 type B-1 cover 50 mm thick reinforced with 8 mm dia TMT bar @ 150 mm c/c both ways, funnel with watering pipe 20 mm dia medium grade, GI protection pipe light grade 40 mm dia and wire mesh complete in addition to item No 1 (a) to (e) of preamble (Notes) under sub-heading earthing, specified on Serial Page No 389 of SSR Part –I 2009.Note No 2 :- Earthing strip and GI protection pipe beyond 7.5 m will be measured and paid separately if required(iii) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself. Please Enable Macros to View BoQ information |