| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GE(I) Kanpur Name of Work : REPAIR/MAINT OF STREET LIGHTS, PERIMETER LIGHTS, FLOOD LIGHTS, BOLLARED LIGHTS, HIGH MAST LIGHTS AND CONNECTED ITEMS IN CANTT AREA UNDER GE (I) KANPUR Contract No : GE(I)/KAN/T-13 OF 2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of Items/Works Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Conversion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Labour only with necessary T&P such as tool kit/ ladder to attend day to day security light/Flood light related works and repair/ replace the unsv spares such as driver control plate/Fuse assembly /cable from fittings to junction box/ GI pipe bracket/clamps/ kiosk box all other required work for making serviceable to security light fitting etc all street light poles 9 /11 mtr long, carried out all complints secure safety complete all as specified and directed. Note : (i) All required parts for making serviceable shall be measured seprately as supply only and fixing charge shall be deemd to included in quoted rates. (ii) Making serviceable one security light will be consider as single job. 3 Any accessories found unserviceable that shall be replaced & paid under respective items of this Sch. 4. T&P, complaint slip book, complaint register and ladder shall be provided by the contractor 5. Complaints of street/flood lights shall be done on daily bases and after completion the complaint slip deposited to concern JE E/M.)6.Contractor shall depute minimum 2 staff daily to attend and rectify the complaint of street light. if not, Contractor shall have to bear a penalty of Rs 50.00 per complaint or maximum of Rs 500 per day on this account |
| 3 | Supply only Driver cercuit plate of LED security light fitting capacity 25 to 60 Watt in origional suitable for Make/ model suggested by Deppt complete all as specified and directed. |
| 4 | Supply only Driver cercuit plate of LED security light fitting capacity 70 to 120 Watt in origional suitable for Make/ model suggested by Deppt complete all as specified and directed. |
| 5 | Supply onlyDriver cercuit plate of LED security light fitting capacity 150 to 200 Watt in origional suitable for Make/ model suggested by Deppt complete all as specified and directed. |
| 6 | Excavation in trenches in any type of soil n exc 1.5 mtr in width and n. exc 1.5 mtr in depth and getting out all as required for laying of cables, foundation filling of poles or stays and for rerouting of cables complete all as specified and directed. |
| 7 | Returning filling including spreading ,leveling, watering and well ramming in layers not exc 25 cm each all as required complete all as specified and directed. |
| 8 | Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed. |
| 9 | M&L for sand cushioning to under ground cables 8 cm thick before laying the cable and 15 cm, thick after laying, stretching and testing the cable complete all as specified and directed.Note:- Punned thickness shall be measured and paid. |
| 10 | M&L for Sub class ‘B’ bricks old size laid dry flat over the cable abutting each other, length of cable equal to width of brick all as required complete all as specified and directed. |
| 11 | M&L for drilling manually in soft / loose soil under road / hard standing / culvert / nala of suitable bore for cable protection pipe upto 80 mm bore complete all as specified and directed. Note: Depth of bore shall not be more than 1 Mtr from original ground level. |
| 12 | Taking out carefully unserviceable LT UG cable up to 240 Sqmm from trenches and relaying same after repairs in same or other indicated location and testing on completion complete all as specified and directed. Note: Earth work, sand, bricks will be measured and paid separately. |
| 13 | Supply and laying to wall or poles or fixing or passing through pipe, in replacement of 1100 volts grade heavy duty cable with XLPE insulated aluminium multistranded conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or strip and overall PVC sheathed 10 sq. mm nominal cross section 4 core in service connections complete all as specified and directed. (Note : Incl making good all distributed wall surfaces/ flooring/tilling to match with existing specification) |
| 14 | Supply and laying in trenches or fixing to wall/pole or passing through pipe XLPE insulated heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 25 Sqmm 3.5 core. (Note : Incl making good all distributed wall surfaces/ flooring/tilling to match with existing specification) |
| 15 | All as per item No 13 above but cable of size 16 Sqmm 4 core complete all as specified and directed. |
| 16 | All as per item No 13 above but cable of size 35 Sqmm 3.5 core complete all as specified and directed. |
| 17 | All as per item No 13 above but cable of size 50 Sqmm 3.5 core complete all as specified and directed. |
| 18 | S&F in replacement of Cable jointing kit for 1100 volt grade cable for outdoor/indoor termination end joint heat shrinkable type complete with jointing material and accessories with full sleeves and thimbles suitable for XLPE/PVC armoured aluminium conductor cable of size 4 to 16 Sqmm 3.5/4 core complete all as specified and directed. |
| 19 | All as per item No 17 above but for 25 to 50 Sqmm size 3.5 core complete all as specified and directed. |
| 20 | All as per item No 17 above but for 70 to 95 Sqmm size 3.5 core complete all as specified and directed. |
| 21 | S&F in replacement of cable jointing kit for 1100 volt grade cable for straight through termination heat shrinkable type complete with jointing material and accessories with full sleeves and thimbles suitable for XLPE/PVC armoured aluminium conductor cable of size 10 to 16 Sqmm 3.5/4 core complete all as specified and directed. |
| 22 | All as per item No 20 above but for 25 to 50 Sqmm size complete all as specified and directed. |
| 23 | All as per item No 20 above but for 70 to 150 Sqmm size complete all as specified and directed. |
| 24 | Supply & fix in replacement PVC insulated and PVC round sheathed 2 Core 4 sq mm Aluminium conductor for voltage Grade 1100 volt complete all as specified & directed.. |
| 25 | Supply & fix in replacement PVC insulated and PVC round sheathed 2 Core 6 sq mm Aluminium conductor for voltage Grade 1100 volt complete all as specified & directed.. |
| 26 | Supply & fix in replacement PVC insulated and PVC round sheathed 2 Core 10 sq mm Aluminium conductor for voltage Grade 1100 volt complete all as specified & directed.. |
| 27 | Material and labour for GI tubing light grade 50mm bore with fittings laid for protection of cable under road crossing fixed to walls or pole cut to piece complete all as specified and directed.(clamps for fixing pipe, nuts, bolts washers shall be measured separately ) |
| 28 | All as per item No 26 above but pipe of size 40mm bore complete all as specified and directed. |
| 29 | All as per item No 26 above but of size 15 mm bore cut to piece and fixed with PCC/steel pole with suitable size clamps, nut, bolt and washers for cable protection and disconnecting existing wire form light and reconnecting same or new cable by laying in pipe all as required at site complete all as specified and directed. |
| 30 | Supply & fix in replacement PVC insulated and PVC round sheathed 3 Core 1.5 sqmm multicore annealed copper conductor for voltage Grade 1100 volt conforming to IS 694:2010 complete all as specified & directed.. |
| 31 | Supply & fix in replacement PVC insulated and PVC round sheathed 3 Core 2.5 sqmm multicore annealed copper conductor for voltage Grade 1100 volt conforming to IS 694:2010 complete all as specified & directed.. |
| 32 | M&L for making 2 hole of 14 mm dia on the existing LT Steel pole at height of 1.5 mtr from GL and top of the pole near to bracket for inserting 2 core, 4 sqmm cable from junction box to street lights all as specified and directed |
| 33 | S&F in replacement of new generation energy saving and environmental friendly long life LED Street light 45 watt made up of pressure die cast aluminium housing with high efficiency LEDs as lighting source and lens embedded PC Cover having top Opening separate driver compartment with IP66 protection and impact resistence of IK07 Available in CCT 5700 K complete all as specified & directed |
| 34 | Supply and fixing in replacement of LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection complete all as specified & directed. |
| 35 | Supply and fixing in replacement of LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection complete all as specified & directed. |
| 36 | Supply and fixing in replacement of LED street light fitting 100 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified & directed. |
| 37 | S&F in replacement LED flood light 30 watt , die cast aluminium housing with LEDs as light source suitable for highlighting architectural features or area lighting including fixing arrangements i.e suitable clamps, nut, bolt and washers IP66 complete all as specified and directed. |
| 38 | S&F in replacement LED flood light 50 watt , die cast aluminium housing with LEDs as light source suitable for highlighting architectural features or area lighting including fixing arrangements i.e suitable clamps, nut, bolt and washers IP66 complete all as specified and directed. |
| 39 | S&F in replacement LED flood light 100 watt , die cast aluminium housing with LEDs as light source suitable for highlighting architectural features or area lighting including fixing arrangements i.e suitable clamps, nut, bolt and washers IP66 complete all as specified and directed. |
| 40 | S&F in replacement LED flood light 200 watt , die cast aluminium housing with LEDs as light source suitable for highlighting architectural features or area lighting including fixing arrangements i.e suitable clamps, nut, bolt and washers IP66 complete all as specified and directed. |
| 41 | Supply and fix in replacement of LED street light bracket made out of 25/32/40 mm bore (as required at site) GI tubing light grade for LED light bend to shape by welding and including fixing arrangements i.e suitable clamps, nut, bolt and washers complete all as specified and directed. |
| 42 | Disconnecting, dismantling and taking out old steel tubular pole any size/ length and making good all disturbed surface to match with existing specifications and re use within 50 mtrs complete all as specified & directed |
| 43 | Supply, errecting and installation of steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9 metres long) duly painted with two coat of black bituminous paint through out, internally and externally up to planning depth and painting remaining portion of pole with two coat of aluminium paint to the entire exposed surfaces over one coat of red oxide primer making/painting three Nos circular strips each of 30 cm wide with one yellow and 02 Nos black colour strip synthetic enamel paint and marking pole number with black paint complete all as specified and directed. |
| 44 | Supply and errect in true vertical position LT electric pole, Octogonal Pole, hot deep galvanised, with base plate of 220x220x12 mm thick, 07 Mtrs Long, top dia 70mm, bottom dia- 135mm, thickness of sheet- 3 mm, including Single arm GI bracket, inbuilt cable junction box with door, connection plate, MCB 6A, duly connecting existing LT UG cable, cable lugs, work included necessary earth work and RCC foundation as per manifacturers recommendation complete all as specified and directed. Make: Bajaj / Crompton or as approved by GENote: Earth work, PCC foundation as per manufacturer recommendation included in the unit rate. |
| 45 | Supply, errecting and installation of steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-64 (12 metres long) duly painted with two coat of black bituminous paint through out, internally and externally up to planning depth and painting remaining portion of pole with two coat of aluminium paint to the entire exposed surfaces over one coat of red oxide primer making/painting three Nos circular strips each of 30 cm wide with one yellow and 02 Nos black colour strip synthetic enamel paint and marking pole number with black paint complete all as specified and directed. |
| 46 | Supply, fixing, testing and comissioning of automatic street light switch of capacity 8 KW in single phase using nature switch for automatic switching of street lights based on LUX level of natural light. The sensor (nature switch) along with suitable power contactor, MCB and support terminals enclosed in pole / wall mounted enclosure made of rust proof, electric shock proof, termite proof and FR grade SMC junction box (Make: Sintex) conforming to IP54, including mounting arrangement with suitable size of FI clamps 02 Nos with complete acessories as under including taking down old street light switch complete all as specified and directed. (i) Contactor rating (AC3) single phase, 50-63 Amp (ii) MCB 63Amps (SP),10 KA, 240 volts: (iii) NATURESWITCH-01 |
| 47 | S&F in replacement of weatherproof junction box of size 350x250x150 mm outdoor type made out of thermo polycarbonat to accmmodated 04 Nos aluminium bus bar of size 25x6 mm rating 200 Amps and MCB SP 6 Amps IP-65 with hinged door and triangular locks water proof, shocked proof, rust proof, corrosion free, acid resistance/fire retardent and self extinguishing UV resistance complete fixed on pole with flat iron clamps of size 25 x 3mm, nuts, bolts, washers etc., including two coats of synthetic enamel paint over and including a coat of redoxide zinc chrome primer on iron/steel parts complete all as specified and directed. |
| 48 | Disonnecting electrically, dismantling and taking out existing street light junction box any size/type from PCC/steel pole and refixing on same pole with flat iron clamps of size 25 x 3mm, nuts, bolts, washers etc after repair including two coats of synthetic enamel paint over and including a coat of redoxide zinc chrome primer on iron/steel parts and making electrical connection complete all as specified and directed. |
| 49 | M&L for painting of steel pole (swan neck type or straight type) up to 12 mtr height with cross arms, clamp of any length and shape for LT overhead line / for stree light with two coat of aluminium paint after scraching out old paint, cleaning and existing surface rust free, preparation of the existing surface, including marking pole numbers in a 20 cm dia yellow circle with number writting with black syenthic paint & painting strips in alternate from bottom to top with three strips of black syenthatic paint & two strips of yellow fluorescent paint (up to 1.5 mtr height) through out the circumference of pole (width of each strip shall be of 30 cm), including one coat of lime wash on PCC copping of pole complete all as specified and directed. |
| 50 | Demolition & dismantling of cement concrete in ground floors and paving for making trench for laying XLPE cable etc including removing the debris from the site complete all as specified and directed. |
| 51 | Material & labour for plain cement concrete 1:3:6, type C1, using 20 mm grade stone aggregate for filling the pavings / trenches / foot path etc complete all as specified and directed. |
| 52 | S&F in replacement of solar street light 30 watt made with high efficiency Mono crystalline solar PV module , lithium ferro phosphate battery with in- built BMS technology , high efficacy LED, MPPT Solar charge controller and aluminium Extruded body & specially programmed to automatically control the dimming and brightness of light, which increases the backup time complete with clamp nut bolt and pole . |
| 53 | M&L for earthing with GI earth plate electrode of size 60cm X 60cm X 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including GI strip of size 32x6 mm up to 7.5 mtr by means of bolts, nuts, check nuts and washers made of brass and protected by light grade 40mm dia upto 7.5 mtr long GI pipe connected to main control board and GI pipe light grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover 50mm thick and PCC chamber pit with PCC 1:2:4 type C2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 metre) and testing making test point and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 including taking down old unserviceable complete all as specified and directed. |
| 54 | Detection of any type of fault in HT underground Line (laid in soil at plane area or forest area) with the help of Cable fault locator machine. Cable fault locator with carring vehicle will be brought by the cable fault detection agencies. Span of faulty cable will be trace out by the agencies by meggering HT cable. Note : 1. Detection of fault in one span of length will be measured as one Job either machine placed from one side or both side of the cable. 2. Technicians will be employed by the working agencies. 3. Earth work and taking out will be measured and paid seperately. 4. Material for repair and replacement measured and paid saperately. 5. One job shall be measured if the fault has successfully identified by the fault locator machine or removing moisture in the cable if required. |
| 55 | M&L in replacement post top lantern fullycast aluminium body finished with polyurethane paint(with prior treatment)with acrylic window cover total length 900 mm and max breath 360mm, B22 brass holder provided with aluminium cover, spigot entry 78 mm, sitable for 30 to 40 W Led bulb complete all as specified and directed. |
| 56 | S&F fullycast aluminium body finished with polyurethane paint bollard of length 730mm and circular base diameter of 245 mm and max diameter of leg of bollard 115 mm surmounted with fully cast aluminium body finished with PU Paint with acrylic window cover with B22 brass holder and 20 watt white/warm white Bulb all as required complete all as specified and directed. Note- Cost of foundation and fixing charges included in quoted unit rate. |
| 57 | Supply,erecting and fixing pole in replacement cast aluminium EXTRA heavy duty designer leg and broader designer basenfinished with polyurethane paint (with prior treatment) with broader plate 422mmx 422 mm diameter of one leg is approx 88mm,outer dia for spigot entry 75 mm,03 Nos \\"T\\" shaped bolt with nuts washers provided for concrete foundation,total length of the pole including base and legs (base with plate x 4 Nos legs) is 3650 mm (12 feet) complete all as specified and directed. Note : Earth work, cement concrete will be measured and paid separetely. |
| 58 | Supply and fixing in replacement cast aluminium designer pole bracket fully cast aluminium finished with polyurethane paint (with prior treatment)with square junction with max projection breath ,suitable for one numbers post top lanterns for 12 feet poles complete all as specified and directed. |
| 59 | Supply and fixing in replacement led post lantern 40 watt fully cast aluminium body finished with polyurethane paint (with prior treatment) with acrylic window cover, total length of fitting 752mm (30 inches)max breath of fitting 431 mm, spigot entry 78mm complete all as specified and directed. Total in Figures 0.0 23 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |