| 1 | Taking up of unserviceable cable of any size any type i.e laid in trenches or in duct/passed through pipes or fixed to wall/poles structure etc and making good as per existing requirement complete all as specified and directed. |
| 2 | Dismantling concrete poles/struts, any size complete all as specified and directed. |
| 3 | Dismantling of unserviceable cross arm such as MS channel /angle section etc complete all as directed. |
| 4 | Dismantling insulators of any type and size complete all as specified and directed. |
| 5 | Dismantling air break gang operated switches verticle/horizontal mounted with two or three insulators per phase including insulators and operating mechanism for repair/replacement of broken/worn out components complete all as specified and as directed. |
| 6 | Dismantling lightening arresters of any type and size complete all as specified and directed. |
| 7 | Material and Labour for XLPE cable insulated screened, PVC bedded galvanized steel strip of wire armored, electric power cable (Heavy duty) with aluminum conductor 11000 volts grade cross sectional area 300 sqmm 3 core suitable for 11 KV earthed system incl taking down old unsv HT conductor complete all as specified and as directed. |
| 8 | Material and Labour for cable end termination jointing kit HT 11 KV grade earthed system (heat shrinkable) outdoor type complete with jointing material suitable for HT XLPE cable 240 sqmm to 300 sqmm 3 core 11 KV grade earthed system incl taking down old unsv HT joint complete all as specified and as directed. |
| 9 | Excavation in trenches in soft/loose soil n.exc 1.5 Mtr deep and n.exc 1.5 mtr wide for laying of HT cable and getting out including Cum dressing/trimming of sides and leveling, grading and ramming of bottom of excavation complete all as specified and as directed. |
| 10 | Material and Labour for fine and dry sand cushioning to under ground cable including provision of layers of sand 8 cm deep before laying and 15cm Cum deep after laying the cable and stretching of cable complete all as specified and as directed. |
| 11 | Returning, filling, including leveling, watering and well ramming excavated soil in layers n.exc 25cm thick in trenches after cable have been laid complete all as specified and as directed. |
| 12 | Removing of excavated surplus soil obtained from excavation to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr of the starting point complete all as specified and as directed. |
| 13 | Supplying and laying for un-reinforced precast concrete cable cover, class precast concrete cable cover, class HV,Type 1 with peak, size 300mm x 180 mm x 40 mm complete all specified and directed. |
| 14 | Supply and installation of Manual Load break switch encloser outdoor type 12kV, 630A, 21kA-3sec.extensible type |
| 15 | Technical DataMechenical Data :- Metal Enclosed switchgear. IEC 62271-200, General Purpose switches: IEC 60265-1, Disconnectors and Earthing switches: IEC 62271-102, Circuit Breakers: IEC 62271-100, Temperature class: -25 °C+40 °C OUTDOOR, Degree of protection, IP 67, - Front cover: IP 2X, Cable cover. IP 3X, Enclosure IP 54, Busbars: 200 mm 2 Copper,, Earth bar (external): 120 mm 2 Cu - Bolt dimension: M10, Thickness of CRCA Enclosure 2 mm CRCA, Access to cable Front cable access Colours/Paint: 60 to 80 microns, Front cover: RAL 7035/7043, Cable cover: RAL 7035/7043, - Enclosure RAL 7043. Please Enable Macros to View BoQ information |
| 16 | Technical DataMechenical Data :- Metal Enclosed switchgear. IEC 62271-200, General Purpose switches: IEC 60265-1, Disconnectors and Earthing switches: IEC 62271-102, Circuit Breakers: IEC 62271-100, Temperature class: -25 °C+40 °C OUTDOOR, Degree of protection, IP 67, - Front cover: IP 2X, Cable cover. IP 3X, Enclosure IP 54, Busbars: 200 mm 2 Copper,, Earth bar (external): 120 mm 2 Cu - Bolt dimension: M10, Thickness of CRCA Enclosure 2 mm CRCA, Access to cable Front cable access Colours/Paint: 60 to 80 microns, Front cover: RAL 7035/7043, Cable cover: RAL 7035/7043, - Enclosure RAL 7043. Please Enable Macros to View BoQ information |