| 1 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for taking out pipe line etc for repairs / laying cables etc and getting out in soft / loose soil complete all as specified and as directed by the Engineer - in - Charge. |
| 2 | All as per item No 01.00 above but more than 1.5 Mtr and upto 2 mtr depth. |
| 3 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed by the Engineer - in - Charge. |
| 4 | Removal of excavated material [soil] to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed by the Engineer - in - Charge. |
| 5 | Supply, laying, jointing and testing of XLPE insulated, screened, PVC bedded galvanised steel strip armoured electric power cable (heavy duty) with aluminium conductor, 11000 Volts grade lay in trenches, ducts, along pole, along Transformer cross sectional area 95 Sqmm 3 Core complete all as specified and directed. |
| 6 | Supply, fixing and laying in trenches or fixing or passing through pipe, 1100 Volts grade heavy duty LT UG cable, 3.5 core 500 Sqmm, with XLPE insulated stranded Aluminium conductor served with an inner sheathing of PVC tape, Armoured with galvanised steel strip and overall sheathed including cable gland, lugs, jointing material etc, jointing, connecting, testing and commissioning all as specified and directed. |
| 7 | Supply, fixing and laying in trenches or fixing or passing through pipe, 1100 Volts grade heavy duty LT UG cable, 3.5 core 240 Sqmm, with XLPE insulated stranded Aluminium conductor served with an inner sheathing of PVC tape, Armoured with galvanised steel strip and overall sheathed including cable gland, lugs, jointing material etc, jointing, connecting, testing and commissioning all as specified and directed. |
| 8 | Supply, fixing and laying in trenches or fixing or passing through pipe, 1100 Volts grade heavy duty LT UG cable, 3.5 core 185 Sqmm, with XLPE insulated stranded Aluminium conductor served with an inner sheathing of PVC tape, Armoured with galvanised steel strip and overall sheathed including cable gland, lugs, jointing material etc, jointing, connecting, testing and commissioning all as specified and directed. |
| 9 | Supply, fixing and laying in trenches or fixing or passing through pipe, 1100 Volts grade heavy duty LT UG cable, 3.5 core 120 Sqmm, with XLPE insulated stranded Aluminium conductor served with an inner sheathing of PVC tape, Armoured with galvanised steel strip and overall sheathed including cable gland, lugs, jointing material etc, jointing, connecting, testing and commissioning all as specified and directed. |
| 10 | Supply, fixing and laying in trenches or fixing or passing through pipe, 1100 Volts grade heavy duty LT UG cable, 3.5 core 70 Sqmm, with XLPE insulated stranded Aluminium conductor served with an inner sheathing of PVC tape, Armoured with galvanised steel strip and overall sheathed including cable gland, lugs, jointing material etc, jointing, connecting, testing and commissioning all as specified and directed. |
| 11 | Supply, fixing and connecting of Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm complete all as specified and directed. make: Raychem/denson/M-3 |
| 12 | Supply joint and commission in replacement of HT 11 KV cable end termination box heat shrinkable type suitable for 3 core 95sqmm XLPE cable 11 KV outdoor type including aluminium ferrules jointing chemical etc complete make: Raychem/denson/M-3 |
| 13 | M&L for Double Walled Corrugated DWC HDPE Pipe of outer dia 90mm and inner dia 75mm including 90 degree bends with coupler and rubber ring laid in trenches of size 90 mm suitable for cable protection of size 70 sqmm to 240 sqmm cable complete all as specified and directed. |
| 14 | Supply and errect in true vertical of steel tubular swaged pole complete with MS Box plate 6 mm thick of size 300 x 300 mm finial taper plug, cap, bolt, nuts washers & screws as specified type 410-SP-55 (11 mtr long) Made out of ERW MS tubing confirming to IS-2713 Part II complete including painting with two coat of aluminium paint over a coat of red oxide primer. |
| 15 | M&L for PCC 1:4:8 type D2 using 40mm graded aggregate for as base to paver block or pole / struts foundation etc all as specified and directed. |
| 16 | M&L for PCC 1:2:4 type B1 using 20mm graded aggregate for coping including necessary form work and fair finishing of exposed surface of concrete all as specified and directed. |
| 17 | Material and labour for platform suitable for the transformer of capacity 315 KVA with PCC 1:4:8 type D-2 using 40mm graded coarse stone aggregates, 150mm thick in foundation, RR Stone masonry work in CM 1:6, pointing to stone masonry in cement mortar 1:4 on exposed surfaces and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grouting bolts etc for panel over and including moorum filling. The platform shall be of 3.0 mtr x 3.0 mtr x 1.5 mtr height above ground level and of adequate size leaving minimum 300 mm all around the transformer for movements. All as shown on drawing No CEPZ/98/TD/6 sheet No 2/2 of dated 21 Apr 98 except size of Plateform. |
| 18 | Supply only Chain link MS galvanised fencing, any size or type complete all as specified and directed. |
| 19 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and as directed by Engr in Charge. |
| 20 | M&L for angle iron posts for chain link fencing, with holes drilled and grouting in the foundation concrete all as directed (Fe 410W) Quality A complete all as specified and directed by Engr in Charge. Note : Concrete for foundation measured seperately under relevant item. |
| 21 | Supply and fixing of cross arms. Bracings, support channel, backpate hooks etc fabricated from structural steel, sections (MS Channel) of required size and shape including nuts, bolts,washers, welding, bending , cutting cold or hot, drilling holes for inserting bolts as indicated and directed including painting with one coat of red oxide primer and two coats of silver aluminium paint complete all as specified and directed by Engr-in-Charge. |
| 22 | Supply, fixing and testing of air break gang operated device, triple pole mechanically operated outdoor type, mounted on and including 11 KV H.T. porcelain insulators 9 Nos and steel channel frame, GI operating rod, 25mm dia of suitaale length with operating mechanism working from ground level, vertically operated including locking arrangement for operating handle, suitable for current rating upto 200 Amp, 11000 Volts working pressure all as specified and directed by Engr-in -Charge. |
| 23 | Supply and fixing of dropout fuse unit explusion type for outdoor air break swirch (GOD) triple pole, mounted on and including insulators for 11000 Volts working pressure fixed to and including MS channel with nuts, bolts, washers etc. synthetic bounded fuse carrying tube complete with line tabs and suitable for current carrying capacity upto 200 Amps only all as specified and directed. |
| 24 | M&L for Lightening arresters station class complete with all fittings, station class, discharge capacity 65 kilo amps, suitable for 11000 Volts all as directed by Engineer-in-charge. |
| 25 | Supply and fixing of polymer pin insulator including one galvanised mild steel spindle two galvanised iron washres and one galvanised iron nut suitable for 11 KV grade complete all as specified and directed by Engr-in-Charge. |
| 26 | Supply, fixing, connecting and testing of Aluminium conductor, steel reinforced suitable for jump connection complete including suitable size PG clamps, brass nuts, bolts and washers for connecting of conductor for jump connection complete all as specifed and directed by Engr in Charge. |
| 27 | M&L for jump connection by using ACSR conductor weasel, alkathine pipe, aluminium lugs, PG clamps, nuts, bolts etc. for complete 4 pole structure all as directed by Engineer-in-charge. |
| 28 | Supply and fixing of galvanized earth strip 32 mm x 6 mm for earthing from earth plate to equipment complete fixed on porcelain insulator every 1 meter interval all as specified and as directed. |
| 29 | Supply and fixing in replacement of galvannised strip 32x6mm with saddles and fixing screws etc. complete all as specified and directed. |
| 30 | Supply and laying of synthetic rubber insulated mats 2.5 mm thick for voltage upto 11 KV for electrical purpose as per IS-15652-2006 suitable for electrical shock safety of size 2m x 1m complete all as specified and directed. |
| 31 | Material and labour in replacement of danger notice board/plate 1.6 mm thick mild steel viterous enameled white with letters/figures and conventional skull and bones in signal red colour and fixed to HT pole with MSFI clamp 20x3 mm clamp 250 mm x 200 mm size of danger board. |
| 32 | Supply, installation, testing and commissioning of plinth mounted step down outdoor type energy efficient level -2 distribution transformer HT 11 KV, 3 Phase, LT 433 V, 4 wire capacity 800 KVA, copper wound, oil immersed laminated iron core naturally cooled with external cooling tubes, type delta connected on primary HT side and star connected on secondary LT side in accordance with vector symbol group DYN -11 (Vector ground - 4) with natural brought on secondary (LT) side & having tapping in equal steps of 2.5% from (±) 5% to (±) 7.5% to be changed by means of hand operated off load tap changing gear, so as to change/ correct LT voltage on secondary side confirming to IS 1180 Part- I 2014 including provision of all neccessary standard fittings and mainly comprising of the following : (a) One cable box on HT side (Primary side) consisting of 3 Nos porcelain bushing with copper rods complete with nuts & bolts.(b) One cable box on LT side (Secondary side) consisting of 4 Nos porcelain bushing with copper rods complete with nuts & washer.(c) Oil conservator oil level gauge.(d) Dehydrating breather with first fill of dehydrating agent (Silica Gel)(e) Explosion vent, thermometer pocket on tank cover, oil drain filter valve, lifting lugs, oil filling hole with cap/ plug air release valve plug & 4 Nos plain solid cast steel detachable rollers.(f) One 100mm dia dial type thermometer, vapour pressure type, having range 0- 120 degree Celsius having maximum temprature reading indicator with resetting. Continue .... |
| 33 | Continue for above Item No.32.00(g) Two earthing terminals on tank to facilitate fixing of 32x6 mm galvanised iron earth strip for earthing body.(h) Rating plate & terminal marking plate.(j) Extra bushing for neutral, in the LT cable box for providing independant set of earthing for neutral.(k) First filling of transformer oil, IS- 335 Marked within (Make - Savita/ Power link) filter & tested upto 50 KV dielectric strength at 2.5 mm air gap between electrodes.(l) PCC foundation of transformer will be provided as per TD CEPZ/98/TD/6 sheet No.2/2.(m) Supply and fixing chain link fencing including line wires, any mesh, 100mm size and 4mm dia type of standards, rails, straining bolts etc including provision of binding wire and all connected items (As per TD CEPZ/98/TD/6 sheet No.2/2.) |
| 34 | Supply, installation, testing and commissioning of plinth mounted step down outdoor type energy efficient level -2 distribution transformer HT 11 KV, 3 Phase, LT 433 V, 4 wire capacity 315 KVA, copper wound, oil immersed laminated iron core naturally cooled with external cooling tubes/fins, type delta connected on primary HT side and star connected on secondary LT side in accordance with vector symbol group DYN -11 (Vector ground - 4) with natural brought on secondary (LT) side & having tapping in equal steps of 2.5% from (±) 5% to (±) 7.5% to be changed by means of hand operated off load tap changing gear, so as to change/ correct LT voltage on secondary side confirming to IS 1180 Part- I 2014 including provision of all neccessary standard fittings and mainly comprising of the following : (a) One cable box on HT side (Primary side) consisting of 3 Nos porcelain bushing with copper rods complete with nuts & bolts.(b) One cable box on LT side (Secondary side) consisting of 4 Nos porcelain bushing with copper rods complete with nuts & washer.(c) Oil conservator oil level gauge.(d) Dehydrating breather with first fill of dehydrating agent (Silica Gel)(e) Explosion vent, thermometer pocket on tank cover, oil drain filter valve, lifting lugs, oil filling hole with cap/ plug air release valve plug & 4 Nos plain solid cast steel detachable rollers.(f) One 100mm dia dial type thermometer, vapour pressure type, having range 0- 120 degree Celsius having maximum temprature reading indicator with resetting. |
| 35 | Continue for above Item No. 33.00(g) Two earthing terminals on tank to facilitate fixing of 32x6 mm galvanised iron earth strip for earthing body.(h) Rating plate & terminal marking plate.(j) Extra bushing for neutral, in the LT cable box for providing independant set of earthing for neutral.(k) First filling of transformer oil, IS- 335 Marked within (Make - Savita/ Power link) filter & tested upto 50 KV dielectric strength at 2.5 mm air gap between electrodes. |
| 36 | Notes for Item No. 32.00 & 33.00(i) Factory Inspection of transformer shall be carriedout by rep of Accepting Officer(ii) After Installation the transformer shall be inspected by SEI/EI of HQ CESC Pune. |
| 37 | M&L for Earthing complete with galvanized steel earth plate electrode 60 cm X 60 cm X 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level connecting to the GI strip 32 x 6mm, by means nut bolt, nuts, check nuts and washer of the GI Earth wire protected by provision of GI light grade pipe 40 mm incl provision of concrete pit in PCC (1:2:4) type B-1 using 20 mm graded stone aggregated with 40 mm thick cover with RCC (1:2:4) reinforced with XPM (weight not less than 4 Kg / Sqm) and frame with lugs 2 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, taste point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 mtr, all as per electric plate No 3 of SSR Part I 2009 and connection to earth test point all as specified incl testing on completion. |
| 38 | Supply, install, testing and commissioning of outdoor type cubical panel board suitable for 3 phase 4 wire 415 Volt, 50 Hz and type tested at CPRI at 415 Volt factory fabricated in an approved factory having modern fabrication process powder coated in approved shard having thickness not less than 100 mircrons provided with suitable gasket to make it dust /vermin proof and general construction confirming to IS 8623793 comprising of the following :- OUTER SHELL : The outer shell shall be made out of 3.15mm thick CRCA Sheet and MS angle section 50x50x6mm frame, factory fabricated with front and back openable double door system locable / openable by keys from both side having chromium plated 19 mm dia fancy lock, louvers and air vent gasket for natural flow of air. The bottom of the outer shell contains a ditachable plate having provn for entry of armoured cable of adequate size with glands. The dimension of the shell should be adequate to accomodate inner shell described below giving minimum 75 mm space all round. Provision of threaded earthing stud at bottom & lifting lugs of suitable size at top to lift the panel safely shall be made. The degree of protection of outer shell shall be IP-54. |
| 39 | Continued from Item No. 35.00 above...INNER SHELL : Inner shell shall be made out of 2 mm thick CRCA sheet duly compartmentalized for each control gears, front & back openable single door system by keys. To accomodate incomer / outgoing MCCBs and TPN copper busbar of rating not less than 1.5 times the rated capacity of the incomer MCCB. The TPN busbar shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size 'F' class insulators. The degree of protection for inner shell shall be IP-42 & carry the following items :- (a) Incoming and outgoing :MCCB 630 Amps, 4 pole, 50 KA, 415 volts - 01 Nos(c) Instrumentation : The inner cubical shall carry the following : (i) Digital panel multifunction meter to measure current, voltage, frequency & power factor having programmable CT ratio (CT ration should be equal to the rated current carrying capacity of incommer MCCB) & built in selector switch of size 96 mm x 96 mm accuracy class 1.0 suitable to work on auxiliary power supply of 240 volts AC with backup protection by 2 Amp MCB. (ii) Indication lamp 22.5 mm dia LED type, 240 Volts AC at the incommer of the unit to show 3 phase availability at the outgoing of incommer with back up protection by 2 Amp MCB. (iii) Inspection LED invertor lamp 12 Watt with movable non ferrous chromium plated arm fitted on topside of inner shell. |
| 40 | M&L for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure. |
| 41 | Supply, install, testing and commissioning of outdoor type cubical panel board suitable for 3 phase 4 wire 415 Volt, 50 Hz and type tested at CPRI at 415 Volt factory fabricated in an approved factory having modern fabrication process powder coated in approved shard having thickness not less than 100 mircrons provided with suitable gasket to make it dust /vermin proof and general construction confirming to IS 8623793 comprising of the following :- OUTER SHELL : The outer shell shall be made out of 3.15mm thick CRCA Sheet and MS angle section 50x50x6mm frame, factory fabricated with front and back openable double door system locable / openable by keys from both side having chromium plated 19 mm dia fancy lock, louvers and air vent gasket for natural flow of air. The bottom of the outer shell contains a ditachable plate having provn for entry of armoured cable of adequate size with glands. The dimension of the shell should be adequate to accomodate inner shell described below giving minimum 75 mm space all round. Provision of threaded earthing stud at bottom & lifting lugs of suitable size at top to lift the panel safely shall be made. The degree of protection of outer shell shall be IP-54. Continue.... |
| 42 | Continued from Item No. 37.00 above...INNER SHELL : Inner shell shall be made out of 2 mm thick CRCA sheet duly compartmentalized for each control gears, front & back openable single door system by keys. To accomodate incomer / outgoing ACB & MCCBs and TPN copper busbar of rating not less than 1.5 times the rated capacity of the incomer ACB. The TPN busbar shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size 'F' class insulators. The degree of protection for inner shell shall be IP-42 & carry the following items :- (a) Incoming :ACB 1250 Amps, 4 pole, 50 KA, 415 volts - 01 Nos(b) Outgoing :- (i) MCCB 500 Amps, 4 pole, 36 KA, 415 volts - 03 Nos (ii) MCCB 100 Amps, TPN, 16 KA - 01 Nos (iii) MCB 32 Amp TPN 10 KA - 01 No.(ii) MCB 32 Amps, Triple pole & Neutral, 415Volts, 50 Hz ICU 10 KA - 01 No.(c) Instrumentation : The inner cubical shall carry the following : (i) Digital panel multifunction meter to measure current, voltage, frequency & power factor having programmable CT ratio (CT ration should be equal to the rated current carrying capacity of incommer MCCB) & built in selector switch of size 96 mm x 96 mm accuracy class 1.0 suitable to work on auxiliary power supply of 240 volts AC with backup protection by 2 Amp MCB. (ii) Indication lamp 22.5 mm dia LED type, 240 Volts AC at the incommer of the unit to show 3 phase availability at the outgoing of incommer with back up protection by 2 Amp MCB. (iii) Inspection LED invertor lamp 12 Watt with movable non ferrous chromium plated arm fitted on topside of inner shell. Please Enable Macros to View BoQ information |
| 43 | Continued from Item No. 37.00 above...INNER SHELL : Inner shell shall be made out of 2 mm thick CRCA sheet duly compartmentalized for each control gears, front & back openable single door system by keys. To accomodate incomer / outgoing ACB & MCCBs and TPN copper busbar of rating not less than 1.5 times the rated capacity of the incomer ACB. The TPN busbar shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size 'F' class insulators. The degree of protection for inner shell shall be IP-42 & carry the following items :- (a) Incoming :ACB 1250 Amps, 4 pole, 50 KA, 415 volts - 01 Nos(b) Outgoing :- (i) MCCB 500 Amps, 4 pole, 36 KA, 415 volts - 03 Nos (ii) MCCB 100 Amps, TPN, 16 KA - 01 Nos (iii) MCB 32 Amp TPN 10 KA - 01 No.(ii) MCB 32 Amps, Triple pole & Neutral, 415Volts, 50 Hz ICU 10 KA - 01 No.(c) Instrumentation : The inner cubical shall carry the following : (i) Digital panel multifunction meter to measure current, voltage, frequency & power factor having programmable CT ratio (CT ration should be equal to the rated current carrying capacity of incommer MCCB) & built in selector switch of size 96 mm x 96 mm accuracy class 1.0 suitable to work on auxiliary power supply of 240 volts AC with backup protection by 2 Amp MCB. (ii) Indication lamp 22.5 mm dia LED type, 240 Volts AC at the incommer of the unit to show 3 phase availability at the outgoing of incommer with back up protection by 2 Amp MCB. (iii) Inspection LED invertor lamp 12 Watt with movable non ferrous chromium plated arm fitted on topside of inner shell. Please Enable Macros to View BoQ information |