| 1 | Taking Dawn , asbestos cement, corrugated or semi-corrugated sheets in roofs, walls etc complete all as specified and directed. |
| 2 | S&F in Repair /Replacement Pre-painted galvalume aluminum zinc coating GI based Corrugated steel sheet 0.47-0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 3 | S&F in Repair /Replacement Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.47-0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 4 | Dismantling timber scantling 40 sqcm and over in section in any position in framed work complete all as specified and directed. |
| 5 | S&F Roof trusses (framed), trussed,purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channelor flat sections) including distance pieces, cleats etc complete all as specified and directed. |
| 6 | S&F Plates (plain or chequered)(Fe 410-W (Gde- E- 250) )channels, square cut or notched(ordinary and counter sunk) with riveted, bolted or welded attachment complete all as specified and directed. |
| 7 | M&L for preparation of new or previously untreated surface of steel or iron surfaces of any description over 10cm width or grith and applying two coats of synthetic enamel paint over a coat of red oxide primer all complete all as specified and directed. |
| 8 | M&L for Machine cut kota stone slab flooring16-18 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over and including screed bed or bedding layer of mortor 15mm thick in CM 1:6 including dismantling of existing Stone slabs and tiles of any description or thickness in floors, aprons etc incl cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises . complete all as apecified and as directed |
| 9 | M&L for kota stone floor 16-18 mm thick,in skirting,set and jointed in neat cement slurry and pointed in white or coloured cement to match including rendering 10 mm thick Cement plaster 1:4 on brick or concrete surfaces including dismantling of existing Stone slabs and tiles of any description or thickness in floors, aprons etc incl cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises . complete all as apecified and as directed |
| 10 | Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed. |
| 11 | S&F Aluminium snap grid frame work for false ceiling of size of grid 605 x 605 mm including hangers 6mm dia, GI (upto 1200mm length) adjusting levels fixed to roof slab by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expension hold fasteners 12.5mm dia, 40mm long complete all as specified. |
| 12 | Material and labour for fixed in repair 6 mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Alumi nium framework with screws as in ceiling all as per specified and directed. |
| 13 | Dismantling of Bricks (laid flat or on edge) or brick tiles/cemented tiles in floors,roof,terrace, channels,kerbs, aprons, etc. (each layer) laid bedded and pointed in any mortar complete all as specifred and as directed. |
| 14 | Complete removal of existing water proofing treatment of any description incl under layer, taking down of cement plaster/demolition of cement concrete any thickness and removal of debris off the premises including grubbing up of trees and preparation of concrete surfaces by scrubbing down with steel brushes and cleaning with water to remove all loose dirt/dust complete all as specified and as directed. |
| 15 | M&L for P.C.C 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in padding over roof including mixing of water proofing compound as per manuacture instruction finished and laid to required slope complete all as specified and as directed. (WPC shall be measured and paid separately) |
| 16 | M&L Rendering 5 mm thck in CM 1:4 on Concrete surfaces of roof finished fair & even and including mixing of water proofing compound (WPC shall be measured and paid separately) complete all as specified and as directed. |
| 17 | supply only Liquid water proofing compound complete all as specified and directed |
| 18 | M&L APP based polymeric membrane minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application incl Applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sq.m, including cleaning surfaces complete all as specified & laying should be asper SSR Part I . |
| 19 | Demolition of brick or stone/boulder masonery, built in cement mortar, including all quoins, arches, pillars, etc. and removing unserviceable material from the work site complete all as specified and as directed. |
| 20 | Brick work with subclass 'B' bricks, old size bricks, straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6, complete all as specified and directed. |
| 21 | Brick work with subclass 'B' bricks, old size bricks,, straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6, using old serviceable bricks obtained from demolition, complete all as specified and directed. |
| 22 | M&L Providing, cement concrete 1:2:4 Type B-1(20mm graded aggregate)including for use of formwork in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands,plinth courses, string courses,lacing courses, parapets and railings upto 60 cm in height,copings, kneelers, apex stones,bed plates, kerbs include for use of formwork complete all as specified and directed. |
| 23 | M&L Rendering 15 mm thick in two layers i. e. (10+5 mm) on fair faces of brick or concrete surface walls in cement mortar 1:4 , rendering is to be finished even and smooth without using extra cement, including mixing WPC in 5mm th second layer of plaster, complete all as specified and as directed. (External surface of walls). Note :- WPC will be measured and paid separetly. |
| 24 | M&L Rendering 10 mm thick on fair faces of brick or concrete surface walls in cement mortar 1:6 , rendering is to be finished even and smooth without using extra cement complete all as specified and as directed. (Internal surface of walls). |
| 25 | Taking down cement plaster on brick or stone walls etc including raking out joints hacking for key scrubbing down with water etc. |
| 26 | M&L 10 thick internal plastering on fair faces of bricks or cone surfaces finished even and smooth w/o using extra cement in cm1:6. |
| 27 | M&L 15mm thick external plastering in two layers (10+5mm) in cm (1:4) mixing with water proofing compound on fair faces of bricks or cone surfaces finished even and smooth w/o using extra cement |
| 28 | Material ad labour for preparation of new plastered surfaces of walls & applying two coats of oil bound distemper by using rollers over 3mm thick wall care putty for smoothning of surface complete all as specified and directed. |
| 29 | Preparation of new plastered/ concrete surfaces of walls and applying two coats of cement based paint by using rollers, including one coat of primer (up to 2nd storey with necessary/scaffolding) complete all as specified and asdirected. |
| 30 | Supply and fixing fixed in repairs Gun-metal, globe or gate valves, (with half turn) ,screwed both ends for iron pipe of 20 mm bore pipe, including making connections complete all as specified. |
| 31 | Disconnecting of existing water tanks exc. 250 Ltrs but not exc 500 Ltrs capacity, setting aside (or lowering if required) for repairs, cleaning, etc and hoisting if required reconnecting and refixing in position incl cleaning and removing all scale and dirt etc complete all as specified and directed. |
| 32 | Disconnecting of existing water tanks exc. 500 Ltrs but not exc 1000 Ltrs capacity, setting aside (or lowering if required) for repairs, cleaning, etc and hoisting if required reconnecting and refixing in position incl cleaning and removing all scale and dirt etc complete all as specified and directed. |
| 33 | Supply and fixing tubes 'medium grade' galvanised, 15 mm bore, ISI marked with all fitting such as bends, tees,elbows, unions,short pieces, connectors, back nuts etc and fixed complete to walls and ceilings or laid in floors,Including Taking up or down steel tubing pipe and connections,including cleaning for re-fixing or removal to store,complete all as specified and directed. |
| 34 | Supply and fixing tubes 'medium grade' galvanised, 20 mm bore, ISI marked with all fitting such as bends, tees,elbows, unions,short pieces, connectors, back nuts etc and fixed complete to walls and ceilings or laid in floors, Including Taking up or down steel tubing pipe and connections,including cleaning for re-fixing or removal to store,complete all as specified and directed. |
| 35 | S&F for PVC (SWR) bends any radius (110 mm ) complete all as specified and directed. |
| 36 | S&F for PVC (SWR) pipes 110 mm single socketed in any length with rubber ring joints fixed to wall complete all as specified and directed. |
| 37 | M&L for preparation of old decorated surfaces of wall, washing, rubbing down and stopping of distempered and painted surfaces and applying one coat of Oil emulsion distemper (white/tinted) over putty filling etccomplete all as specified and directed. |
| 38 | M&L for preperation of old decorated surface of wall washing rubbing down and stopping of distempered and painted surfaces and applying two coat of oil bound distemper on 03 mm thick wall care putty on wall complete all as specified and directed. |
| 39 | Preparation of old decorated brick/concrete/ plastered/unplastered surfaces of walls, Pillars, cornices etc by booming down with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts, trading oil and greasy spots, rubbing with sand paper and applying one coat of cement base paint on walls, pillars, cornice etc (upto 2nd storey with necessary scaffolding complete all as specified and directed. |
| 40 | M&L for preparation of old painted wooden surfaces of any description not other wise described over 10cm width or girth and applying one coat (finishing coat) of synthetic enamel paint complete all as specified and directed. |
| 41 | M&L for preparation of old painted steel surfaces of any description not other wise described over 10cm width or girth and applying one coat (finishing coat) of synthetic enamel paint complete all as specified and directed. |
| 42 | Note:- The contract sum arrived after deduction of amount of Sch of credit as listed in tender Documents. Please Enable Macros to View BoQ information |