| 1 | Rendering 10+5 mm thick on fair faces of brick or concrete surface walls in two layers, in cement mortar 1:4 , rendering is to be finished even and fair without using extra cement (up to 3rd storey with necessary scaffolding) including taking down old cement plaster of any description on brick or stone walls or from concrete surface including raking out joints, hacking for key, scrubbing down with water etc, and removing unserviceable material outside cantt area complete all as specified and as directed. |
| 2 | M&L Rendering cement plaster, 10 mm thick on fair faces of brick/concrete surfaces of wall in cement mortar 1:6 finished even and smooth w/o using extra cement including taking down old cement plaster of any description on brick or stone walls or from concrete surface including raking out joints, hacking for key, scrubbing down with water etc, and removing unserviceable material outside cantt area complete all as specified. |
| 3 | Rendering 5 mm thick on fair faces of brick or concrete surface ceilings, in cement mortar 1:3 , rendering is to be finished even and smooth without using extra cement including taking down old cement plaster of any description on brick or stone walls or from concrete surface including raking out joints, hacking for key, scrubbing down with water etc, and removing unserviceable material outside cantt area complete all as specified and as directed. |
| 4 | Material and labour Ceramic coloured tiles 10 mm thick (square/ rectangular) polished area of each tiles exceeding 0.18 sqm but not exceeding 0.38 sqm , in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match and set in neat cement slurry and pointed with coloured/white cement to match over and including 15 mm thick screed bed in CM 1:4 including dismantling floor, hearth or wall tilling incl cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises.complete all as specified and directed. |
| 5 | M&L non skid coloured ceramic tiles 7 to 8mm thk(square/rectangular joint free) area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed or bedding layer of mortor 15mm thick in CM 1:6, including dismantling floor, hearth or wall tilling incl cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises.complete all as specified and directed. |
| 6 | M&L glazed coloured ceramic tiles joint free in vertical surfaces of wall of size 450x350x7mm/450 x300 x 7mm thick set & jointed in neat cement slurry and pointed in white or coloured cement to match over 10 mm thick rendering in CM 1:4 on brick /concrete surfaces including dismantling floor, hearth or wall tilling incl cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises.complete all as specified and directed. |
| 7 | Demolition of cement concrete (unreinforced) ground floor to second floors and pavings n exc 15 cm thickness (below or above ground level ) and removing the rubbish from the work site out side defence premises complete all as specified. |
| 8 | Rendering 15mm thck in CM 1:3 or Plain Cement Concrete as in sunken floors without extra cement on walls/floors and including mixing of water proofing compound (WPC shall be measured and paid separately) |
| 9 | M & L for sunken floor water proofing treatment as follows:- (a)Complete removing of existing tretment and Cleaning of dust removal to all loose existing sunken floor any material manually and with heat task gun to get smooth plain finished surface including removing of vegetation/plantation with no loose material on surface. (b) Repair all joints and cracks with highly elastic bituminous cold applied putty of tarplastic having penetration after setting upto 8mm thick. (c) Levelling of surface to give proper slope will be done as per site requirements with Shalipatch or equivalent make as approved by GE (d) Apply cold. Bituminous mortar and cold emulsion cum water proofing liquid of Shalikote-T-10 or equivalent make as approved by GE, to create SSD condition on surface with water. (e) Prime the surface with Tarfelt LM or equivalent make as approved by GE mixed with portable water in the ratio of 1:1 and apply @ 400gm per Sqm (as per surface condition). (f) Apply first coat of Tarfelt LM or equivalent make as approved by GE having alongwith 200% conforming to ASTM-C-412 & having crack bindging of 8mm conforming to ASTM-C-836 with tensile strength (g) After 7 days apply 0.50mm conforming to ASTM-C-412 with no diluation water on primed surface while the surface is still tacky with consumption of 700gm /Sqm. Lay Geotex of 45 GSM/fiber mesh simultaneously and paste it properly with overlap of 50mm. |
| 10 | (h) Allowed first coat to dry for 10 to 12 hrs. (i) Apply 2nd coat on cured first coat with consumption @ 700gm/Sqm in opposite direction of 1st coat by brush or roller. (j) Allow it to dry for 10-12 hrs (k) Apply 3rd coat with consumption @ 700gm/Sqm. (l) Ensure final curing time of 36 hrs before allowing/carrying out any further work. (m) Conduct ponding test after minimum 7 days (n) Apply 2 coats of U V Resistand Elastomeric Exterior Axcrylic weather resistant water proof coating of Shalicryl - 215 or eauivalent make as approved by GE having elongation of 300% (p) After, curing of 14 days conforming to ASTM D-6083, for U V protection of bituminous Elastomeric Acrylic emulsified liquid membrance of Tarfelt LM or equivalent make as approved by GE to give long life and prevent its deterioration from sunlight. Note : Application of water proofing treatment will be done by authorised applicator only. |
| 11 | M&L Cement concrete type E-2, 1:5:10 ( 40 mm graded agregate) in Sunkan filling and mass concrete complete all as specified and directed by Engr-in-charge. |
| 12 | M&L 40 mm dia G I tubing heavy grade galvanised laid over floors as a spout pipe in sunken floors all as specified. |
| 13 | Supply only Water proofing compound liquid. |
| 14 | M&L for repairing of concrete surfaces such as balcony, chajjas, upward or downward facias ,column, pillar, ceiling and similar items with plain cement concrete 1:2:4 type B-0 including minimum reinforcement or rendering 10-15mm thick as per site requirement in CM 1:3 without using extra cement finished even and fair complete all as specified and directed (Up to second storey bldgs and including necessory formwork and scaffolding and provision of minimum reinforcement required as per site condition also taking down or dismantling as required at site). |
| 15 | M&L for RCC M-15, nominal mix, type B-1(1:2:4), using 20mm graded crushed stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, including demolition of reinforced cement concrete of any discription ground to 3rd floors and removing the rubbish from the work site out side defence premises complete all as specified and directed. |
| 16 | M&L for TMT mild steel bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for column, hooking end and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed. |
| 17 | M&L for use and waste form work to soffits of suspended slabs such as roof slabs, floor slabs landings and similar work, not exceeding 200mm thick (horizontal or sloping) for rough finished surfaces of concrete, complete all as specified and directed. |
| 18 | M&L for use and waste form work to edges of concrete flats, treads, break in floors, window cills, concrete railings, openings in concrete walls, floor and roof and not exc. 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc. 10cm but n.exc. 20cm wide for fair finished surfaces of concrete, complete all as specified & directed |
| 19 | Complete removal of existing water proofing treatment of any description incl under layer, taking down of cement plaster/demolition of cement concrete any thickness and removal of debris off the premises including grubbing up of trees and preparation of concrete surfaces by scrubbing down with steel brushes and cleaning with water to remove all loose dirt/dust. |
| 20 | M&L for P.C.C 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in padding over roof finished and laid to required slope complete all as specified and as directed. |
| 21 | M&L Rendering 15mm thck in CM 1:4 on Concrete surfaces of roof finished fair & even and including mixing of water proofing compound (WPC shall be measured and paid separately) |
| 22 | M&L for water proofing treatment in the following sequences:-(a) Applying 1st course of bituminous primer conforming to IS -3384 @ 0.4 Kg/Sqm cover the surface till the surface properly impregnated and insolvent oil primer evoporate completely (bi) Applying 2nd coat of blown 85/25 graded bitumen confirming to IS 702 @ 1.2 Kg/sqm. (C) Applying 3rd course of APP (Atactic Polypropylene) modified polymeric membrane 3 mm thick weight not less than 3.6 Kg/Sqm with 160 Grams/Sqm non woven polyester made at centre core reinforced laid with 75 mm side overlap and 100 mm overlap. The membrane has to be laid with LPG torch and overlap sealed and finished neat complete all as specified and as directed . |
| 23 | M&L for preparation of newly sufrace of APP Membrane and applying two coats of water based bituminious alumunium paint @ 200 ml per sqm etc |
| 24 | M&L Cutting grooves in brick wall, 75 mm wide and 65 mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and as directed by Engineer-in-charge. |
| 25 | Brick work with subclass 'B' bricks, old size bricks, straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6, including demolition of brick work built in cement mortar or cement lime mortar incl all quoins, arches pillars etc and removing unserviceable material from the work site ouside defence premises complete all as specified and as directed. |
| 26 | Brick work with subclass 'B' bricks, old size bricks, straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6 but except bricks 6, including demolition of brick work built in cement mortar or cement lime mortar incl all quoins, arches pillars etc and removing unserviceable material from the work site ouside defence premisescomplete all as specified and as directed. |
| 27 | M&L Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4, including demolition of brick work built in cement mortar or cement lime mortar incl all quoins, arches pillars etc and removing unserviceable material from the work site ouside defence premises complete all as specified. |
| 28 | Supply and fixing Rotational moulded polyethylene water storage tanks of 1000 litres capacity,(cylindrical vertical with closed top) with plastic lid cover, triple layered, white, hoisted and fixed in position all as specified in SSR Part-I including PTMT Ball valves high pressure with epoxy coated Aluminium rod & high density plastic ball complete, screwed for iron pipe or brass ferrule and fixed for 20 mm bore pipe, including making connections, including dismantling water tanks and removing to store of water storage tanks (Cap. 500 ltr to 1000 ltr ) complete all as specified. |
| 29 | Supply and fixing Rotational moulded polyethylene water storage tanks of 500 litres capacity,(cylindrical vertical with closed top) with plastic lid cover, triple layered, white, hoisted and fixed in position all as specified in SSR Part-I including PTMT Ball valves high pressure with epoxy coated Aluminium rod & high density plastic ball complete, screwed for iron pipe or brass ferrule and fixed for 20 mm bore pipe, including making connections, including dismantling water tanks and removing to store of water storage tanks (Cap. 250 ltr to 500 ltr ) complete all as specified |
| 30 | Cleaning and removing all scale and dirt etc, from exc 250 & n exc 500 litres capacity tanks in any position and from mouths of circulating pipes etc, and disinfection completely by making all the arrangements and writing date of cleaning on side of tanks also containing completion from user , including disconnecting of water tank of 500 ltr capacity setting aside (or lowering if required) for repairs, cleaning etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing,etc. measured separately). complete all as directed. |
| 31 | Cleaning and removing all scale and dirt etc, from exc 500 & n exc 1000 litres capacity tanks in any position and from mouths of circulating pipes etc, and disinfection completely by making all the arrangements and writing date of cleaning on side of tanks also containing completion from user complete, including disconnecting of water tank of 1000 ltr capacity setting aside (or lowering if required) for repairs, cleaning etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing,etc. measured separately).all as directed. |
| 32 | Supply and fixing in repair Gun-metal, globe or gate valves, with iron wheel head,screwed both ends for iron pipe of 20 mm bore pipe, including making connections complete all as specified and fixed. |
| 33 | Supply and fixing in repair Gun-metal, globe or gate valves, with iron wheel head,screwed both ends for iron pipe of 15 mm bore pipe, including making connections complete all as specified and fixed. |
| 34 | Supply and fixing in repair Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe of 20 mm bore pipe including making connections complete all as as specified and fixed (Minimum weight 20mm-210 gms). |
| 35 | S&F in repair PVC tank covers required for 500 ltr to 1000 ltr PVC water tanks complete all as specified and fixed |
| 36 | Supply and fixing 16 mm nominal outer dia Chlorinated Polyvinyl Chloride (CPVC) pipes SDR 11, having thermal stability for hot & cold water supply, including all Plain CPVC SDR 11 fittings & brass threaded fittings on walls/ceiling or laying in floors,including fixing the pipe with clamps. This includes jointing of pipes & fittings with one step CPVC solvent cement, complete, including taking up or down steel tubing of 15 mm bore pipe and connections,including cleaning for re-fixing or removal to store, as per direction of Engineer in Charge. |
| 37 | Supply and fixing 20 mm nominal outer dia Chlorinated Polyvinyl Chloride (CPVC) pipes SDR 11, having thermal stability for hot & cold water supply, including all Plain CPVC SDR 11 fittings & brass threaded fittings on walls/ceiling or laying in floors,including fixing the pipe with clamps. This includes jointing of pipes & fittings with one step CPVC solvent cement, including taking up or down steel tubing of 20 mm bore pipe and connections,including cleaning for re-fixing or removal to store complete as per direction of Engineer in Charge. |
| 38 | S&F in repair 15mm bore CP Bib taps, fancy type, with crutch or butterfly handle, Long Body, screwed down, screwed for iron pipe or for brass ferrule and fixed all as specified complete all as specified. |
| 39 | S&F in repair Exposed Part Kit of Concealed Stop Cock with Fitting Sleeve, Operating Lever & Adjustable Wall Flange (Compatible with ALD-069) complete all as specified and directed. |
| 40 | S&F in repair 15mm bore angle valve with wall flange , chromium plated fancy type screwed for 15 mm iron pipe, complete all as specified and directed. |
| 41 | S&F in repair PVC valveless,syphonic action type, flushing cistern, low level,white with inlet, ball valve, float and handle including brackets, PVC 32 mm 'L' bend of capacity 10.0 litres and making good to dismantled/damaged floor/surfaces, fixing in repair, complete all as specified and as directed. |
| 42 | S&F in repair WC Orissa pattern white with integral foot rest 580x 440 mm including L bend, & PCC bedding in 1:2:4 and making good disturbed floor connecting to trap and flush pipe compete all as specified and directed. |
| 43 | Repair to existing PVC pipe/CI pipe including making the joints water tight by using suitable material including cleaning if required and refixing of any dia. Note : Work to be carried out up to 2nd storey bldg in any condition of working place/area |
| 44 | Material and labour for Sealing of WC/Floor traps joint and joints between rain water pipe and roof by using neat white cement paste or leak proof material and making the joint leakproof in case seepage is observed from WC/Floor trap and joint of rain water pipe and roof slab. Note : Work to be carried out up to 2nd storey bldg in any condition of working place/area |
| 45 | Taking down shutters of any description n.exc 1.00 Sqm each and removing from the site all as specified & directed. |
| 46 | Taking down shutters of any description exc 1.00 Sqm and n.exc. 2.00 sqm each and removing from the site all as specified & directed. |
| 47 | Taking down chowkats or frames with shutter (without taking off shutter from the frame) n.exc 1.5 Sqm each including cutting holes for taking out hold fast or dismantling brick work and removing from site all as specified. |
| 48 | Taking down chowkats or frames with shutter (without taking off shutter from the frame) exc 1.5 Sqm & n.exc 4 Sqm each including cutting holes for taking out hold fast or dismantling brick work and removing from site all as specified. |
| 49 | S&F pressed steel frames of size 125mm x 60mm made out of size 1.25mm thick MS sheet for doors single rebated including mild steel hinges medium weight 100 mm long and 25mm x 3mm flat iron in holdfast,tie bar including necessary fixing lugs, hold fast, lock strike plate and fixing arrangement etc complete as specified and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-1 including PCC 1:3:6 as in back fill to chowkats all as Specified. Make:- Shivam Steel, Jammu |
| 50 | S&F pressed steel frames of size 105mm x 60mm made out of size 1.25mm thick MS sheet for doors double rebated including mild steel hinges medium weight 100 mm long and 25mm x 3mm flat iron in holdfast,tie bar including necessary fixing lugs, hold fast, lock strike plate and fixing arrangement etc complete as specified and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-1 including PCC 1:3:6 as in back fill to chowkats all as Specified and directed. |
| 51 | Supply and fixing Factory made, plain framed, panelled shutter (two Panel) 35mm thick, 2nd class Hardwood with lock rail and panel of 9 mm B.W.P commercial ply. The size of rail and stiles as per as per IS:1003 (Part-I),kiln seasoned and chemically pressure treated complete all as specified and directed. |
| 52 | Supply and fixing 35mm thick 2nd Class hard wood glazed,gauzed and skelton shutters open rebated and prepare to receive glass, gauge etc but divided into squares with plain chamfered or rounded mitred and rebated sash bars,stiles and rails as specified in SSR Part-I Sec 8 clause 8.24 (a) complete all as specified |
| 53 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm Plain colour PVC sheet reinforced with mild steel square tube, supplying and fixing in opening as per specifications and drawing including making good to disturbed surface of walls, complete all as specified and as directed. |
| 54 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppplying and fixing in the frame at site as per specification & drawing complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 55 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppplying and fixing in the frame at site as per specification & drawing complete all as specified and as directed. Please Enable Macros to View BoQ information |