| 1 | Dismantling of wall and ceiling boards, any thickness including cover fillets complete. |
| 2 | M & L for anodised aluminium snap grid frame work for false ceiling complet all as specified and directed. |
| 3 | S&F 4mm thick HSPC non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws as in ceiling. |
| 4 | Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quions, arches, pillars, etc, dressed stone work and precast concrete article |
| 5 | M & L for Brick work with subclass 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complet all as specified and directed. |
| 6 | Taking down cement plaster any description on brick or stone walls or wall tiles etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed. |
| 7 | M&L for rendering 10mm thick in ceiling on brick work or concrete surfaces in CM 1:3, finished even and smooth without using extra cement all as specified and directed. |
| 8 | M&L for rendering 10mm thick internal wall surfaces on fair faces of brick work or concrete in CM 1:6 complet all as specified and directed. |
| 9 | M & L for preparation of new plastered/decorated wall surfaces and applying two coats of distempering with oil bound distemper as per manufacturer instruction white or tinted complete all as specified and directed. |
| 10 | M&L for two coats of oil bound distemper on newly plastered surfaces of celling including prepration of surfaces complete all as specified and directed. |
| 11 | M & L for applying a thin layer of 0.50mm thick white wall care putty over newly plastered surface to prepare the surface even and smooth complete all as specified and directed. |
| 12 | M & L for rendering 15mm thick on fair faces of brick or concrete surfaces in cement plaster 1:4 using WPC 3% by weight of cement (WPC to be measured and paid separately) and finished even and smooth (without using extra cement) complet all as specified and directed. |
| 13 | Supply Only integral water proofing compound |
| 14 | M & L for preparation of new plastered/decoarated wall surfaces and Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and directed. |
| 15 | M&L for one coat of exterior weather coat paint white or tinted on walls or fascia of roof or chajjas on old decorated prepared plastered/painted surfaces of bldg all as specified & directed. |
| 16 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for and removing from the site. |
| 17 | M & L for providing 75mm thick PCC 1:3:6, type C-1, (using 20 mm graded aggregate) as sub base flooring complete and finishing surfaces even and smooth without using extra cement complet all as specified and directed.. |
| 18 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises. |
| 19 | M&L for vitrified Ceramic tiles light shed 8 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and incl 15mm thick screed bed or bedding layer with CM 1:6 complet all as specified and directed. |
| 20 | All as per ser item No 19 above but as in vertical surfaces in skirting and dado including rendering/screeding including cement mortar1:4 , 10mm thick complet all as specified and directed. |
| 21 | S & F sandwiched hollow PVC wall Lining/panelling consisting of 5mm thick Plain designer colour PVC sheet but single side prelam PVC sheet used instead of plain colour sheet inclusive of solvent cement and fixing at site on wall/PVC frame etc complete all as per specified and directed. |
| 22 | M & L for preparation of old decorated surfaces including brooming down or steel wire brushing complete of walls and applying one coat of distempering with oil bound distemper as per manufacturer instruction white or tinted complete all as specified and directed. |
| 23 | M & L for applying a thin layer of 0.50mm thick Birla white putty/JK white wall care putty on wall surfaces including removal of existing treatment and making the surface uniform and smooth complete all as specified and directed. |
| 24 | M & L for Preparation of old decorated surfaces of ceiling and applying one coat of distempering with oil bound distemper as per manufacturer instructions white or tinted complete all as specified and directed. |
| 25 | M & L for Cement concrete type B-0, 1:2:4 (12.5 mm graded aggregate), 25 mm thick in flooring etc complete all specified and as directed |
| 26 | M&L for preparation and filling of pitting/cracks (including V groove cutting of cracks/deepening) on surfaces with crack seal and finishing the surfaces as per existing treatment complete all as specified and directed. |
| 27 | Demolition of cement Concrete(unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) or as in sunken |
| 28 | M & L PCC 1:3:6, type C-2, 50mm thick as in plinth protection, Surface finished fair and smooth without using extra cement. |
| 29 | M & L for providing PCC 1:3:6, type C-1, (using 20 mm graded aggregate) for saucer drain etc complete and finishing surfaces even and smooth without using extra cement complete. |
| 30 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 31 | M & L for Reinforced cement concrete (nominal mix) Type B1 1:2:4 (20 mm graded stone aggregate) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like. |
| 32 | M & L for use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) rough finished flat surface of concrete complete all as specified and directed. |
| 33 | M&L for Mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complet all as specified and directed. |
| 34 | Taking down chowkhats or frames not exc 1.5 Sqm (without taking shutters from the frame). |
| 35 | Taking down chowkhats or frames exc 1.5 Sqm but exc 4.0 Sqm (without taking shutters from the frame). |
| 36 | S&F aluminum frame powder coated for doors, windows, ventilators with one or more rebates including jointing cleat for fixing etc. complete all as specified and directed. |
| 37 | S&F anodised aluminium door shutter with powder coating (minimum thickness of powder coating 50 micron) aluminium sections weighing not less than 1.0 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, anodised aluminium hinges, snap beading, screws,etc complete all as specified |
| 38 | S&F any colour, aluminum window and ventilator shutters, powder coated sliding/side hung type with sash bars, aluminium section weighing not less than 0.55 Kg/ Sqm including necessary jointing cleats, glazing clips, ruber packing, anodised aluminium snap beading, screws etc. complete all as specified and directed. |
| 39 | S & F in repairs Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty complete all as specified. |
| 40 | S&F in replacement aluminium (die cast body) door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and weight between 61 to 80 Kg complete all as specified as directed. |
| 41 | S & F 100 mm long mortice latch with two levers (vertical type), mild steel body complete all as specified and directed. |
| 42 | S&F galvanised stainless steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks, or galvanised wire staples or screw complete all as specified and directed. |
| 43 | S & F 4 mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads or rubber beading in squares of any size complete all as specified and directed |
| 44 | S&F in repair galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks, or galvanised wire staples or screw complete all as specified and directed. |
| 45 | S&F in repair 4mm thick sheet glass, pin head type and glazing with oil putty or wooden beads or rubber beading in a square n exc 0.5 Sq m in each pane (to be fixed upto four storey of bldgs) |
| 46 | S&F Sheet glass 5.5 mm thickness, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complet all as specified and directed. |
| 47 | M&L 6 mm thick prelaminated particle board, interior grade, prelaminated both side with decorative choice lamination fixed with screws/beading to timber/aluminium frame work or as required on site including fixing arrangement complete all as specified |
| 48 | Taking down existing door shutter with frame area exceeding 1 Sqm & n exc 2.5 sqm and re-fixing in same opening after repair/replace the defective jointing cleats/screws all as specified and directed |
| 49 | S & F in repair 20mm bore cut to length as required stainless steel decorative draphery rods with brackets and decorative finails as required colour complete all as specified and directed. |
| 50 | Roughning for old concrete surface/floor by picking, weeping clean and washing with down with water to remove dust or complete removal of existing roof treatment including brushing neat cement slurry with 3.00 Kg of cement per sqm etc. |
| 51 | M &L for Surface Preperation - Removal of all loose particles, dust,dirt,oil , grease,algae and fungus use wire mesh . Clean the surface and allow it to dry completely indetify and mark all visible cracks . Fill hairline cracks with smartC are crackseal . for wider cracks , use polymer modified mortar allow sufficient curing time as per product guidelines. Supply and application of smartcare PU infinia in three coats, with a minimum coverage of 1.8 kg / sqm, incorporating a fleece layer sandwiched between the first and second coats. the application is to be carried out over a surface primed with smartcare PU infinia primer , applied at a minimum coverage of 0.2 kg/sqm . The membrane exhibits the following properties elongation with fleece : 80% elongation without fleece : 400% crack bridging capability : upto 6.5 mm pull off strength : 1.5 mpa puncture resistance : greater than 200 N |
| 52 | M & L for Formation of coving using cement mortar (1:3) or approved material . Coving shall be semicircular or triangular in shape with a redius /height of 75 mm . Ensure proper bonding with the terrace surface and adjoining walls to ensure durability. |
| 53 | Taking down copper /aluminium point wiring (light, fan, bell, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendent, regulators, sockets, light fitting etc. Removing materials to store for keeping in safe custody or for taking credit (credit a for above items should be made as per condition seperately) and making good distrubed surfaces of walls, floors etc complete all as specified and directed at site. |
| 54 | Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main Switch/Busbar including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface complete all as specified and directed. |
| 55 | Taking down carefully copper/aluminium Sub main wiring of any size from surface/concealed /existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed. |
| 56 | Taking down ceiling fan/ exhaust fan of any sweep after disconnecting all necessary electrical connections from ceiling rose to fan, fan blades and deposit to MES store yard of AGE E/M complete all as specified and as directed. |
| 57 | M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after chasing in wall/ceiling etc, heavy duty ISI marked, with GI sunken boxes 1.2 mm thick, 60 mm deep with earth dolly duly, covered with modular white cover plate with inner frame suitable for modular switches, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed for the following :- |
| 58 | (a) One light point controlled by one, one way switch 5 Amps |
| 59 | (b) One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator |
| 60 | (c) One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board. |
| 61 | (d) One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad. |
| 62 | Description all as per item No 57 here in before but using 2.5 sq mm single core copper conductor cable of multistranded FRLSH insulated unsheathed 1100 volts grade for 5/15 amps point including necessary running of 2.5 sq mm copper FRLSH wire as earth continuity conductor along with wiring and connecting to the common earth dolly. |
| 63 | Description all as per item No 57 here in before but using 4 sq mm single core copper conductor cable of multistranded FRLSH insulated unsheathed 1100 volts grade for 5/15 amps point controlled with modular motor starter for air conditioner including necessary running of 4 sq mm copper FRLSH wire as earth continuity conductor along with wiring and connecting to the common earth dolly. |
| 64 | S & F modular switch piano flush type, single pole, one way, and 5/6 Amp single module complet all as specified and directed. |
| 65 | S & F modular switch piano flush type, single pole, one way, and 15/16 Amp single module complet all as specified and directed. |
| 66 | S & F modular socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, 5/6 Amp, 2 module piano flush type complet all as specified and directed. |
| 67 | S & F modular socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, 2 module piano flush type complet all as specified and directed. |
| 68 | S & F modular motor starter 32 A capacity 2 module complete all as specified. |
| 69 | S & F for Ceiling rose, surface Bakelite with 3 terminals, ISI marked for batten fitting complete all as specified |
| 70 | S & F Fan step regulator, 120W - 2 module complete all as specified. |
| 71 | M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable,one run of 6 sqmm cable and one run of PVC conduit will be measured as one unit |
| 72 | S & F for sheet metal enclosure MCB DB vertical TPN 4 way suitable for MCCB with 200 Amps rated bus bar 240 volts double door with locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of disturbed surface to mtch with existing colour of wall complete all as specified and as directed. |
| 73 | S & F for sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of disturbed surface to mtch with existing colour of wall complete all as specified and as directed. |
| 74 | S & F for MCB Single pole and neutral rated capacity 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed. |
| 75 | S & F for MCB Single pole rated capacity 5 to 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed. |
| 76 | S & F for MCCB four pole rated capacity 100 Amps, 415 Volts breaking capacity 16 KA complete all as specified and as directed. |
| 77 | Hanging only ceiling fan including provision of fastner, cable from ceiling rose or connector to fan |
| 78 | S & F LED lights fitting 1x 20 W, 220V,AC Polycarbonate body with driver, holder including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complet all as specified and directed. |
| 79 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complet all as specified and directed.. |
| 80 | Taking down carefully Split type AC of any capacity with all accessories such as indoor unit, out door unit, copper pipe inlet outlet, flair nut etc. and shifting to new position including minor accessories, and making good the opening of old location with cement mortor 1:3, treating the wall to matching with existing surface finish and making opening holes on brick wall at new location and gap well finish with cement mortor 1:3, making good the wall surface to match with existing surface, installation and commissioning with replacement of insulation of suction & discharge line complete all as directed.complete all as specified and directed. |
| 81 | M & L for earthing complete with galvanized earth plate electrode 600mmx 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5mtr below ground level connected to galvenised earth lead wire of 4 mm dia by means of nuts, bolts, washes of galvanized iron or steel all as shown in electrical plate No 5 and testing on completion including adequate charcoal dust comman salt necessary excavation & earth work PCC(1:3:6) type C-1 pit with precast RCC Cover slab 40 mm thick in PCC(1:2:4) type B-1 reinforced with 6 mm dia MS bars @ 100 mm c/c both ways with funnel wire mesh and 20 mm dia GI pipe medium grade as watering pipe and connected to earthing point complete all as specified and as directed. |
| 82 | Taking up/down XLPE aluminium conductor cable of any size all as specified and diected |
| 83 | M&L for laying, comnecting and testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 1100 volts Earthed, grade cross sectional area 50 sq. mm. of 4 core all as specified and directed |
| 84 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5m in depth for laying of pipe, cable, foundation of electric pole etc and getting out in soft/loose soil, complet all as specified and directed. |
| 85 | Supply and laying river bed fine sand in trenches/ ducts 15 cm under cable and 8 cm above the cable for cushioning / protection to cable including spreading, levelling and get thick 18cm after hand punning complete all as specified and directed |
| 86 | Returning, filling in including spreading leveling watering and well ramming in layers not exc. 25 cm thick complete all as specified and directed. |
| 87 | Removing surplus soil to a distance not exc. 50 M and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed. |
| 88 | Supply and laying for brick of common burnt clay, sub class 'B' old size laid flat and dry on cables as in cable protection in trenches over cables perpendicular to direction of cables abutting each other complete all as specified and directed. note :-all measurement in meter |
| 89 | Supply,laying galvanised steel tubing light grade complete with all fitting of size 50 mm dia for cable protection along with pole across road etc. Complete all as specified and directed Supply and laying river bed fine sand in trenches/ ducts 15 cm under cable and 8 cm above the cable for cushioning / protection to cable including spreading, levelling and get thick 18cm after hand punning complete all as specified and directed at site. Please Enable Macros to View BoQ information |