| 1 | Safe Carriage of other line material from PVVNL, Store to site including loading & unloading both ends. |
| 2 | Safe Carriage of 11 KV Bus Cuppler/33 KV Control pannel from PVVNL, Store to site including loading & unloading both ends. |
| 3 | Installition & reconnection of 11 KV Bus Coupler as per Respo norms |
| 4 | Installition & reconnection of 33 KV Control pannel for Double T/f as per Respo norms |
| 5 | Safe Carriage of ACSR Panther conductor from PVVNL, Store to site including loading & unloading both ends. |
| 6 | Replacemt of existing 33 KV Bus bar from dog conductor to Panther conductor |
| 7 | Safe Carriage of 33KV XLPE cable 3x300 sqmm from PVVNL, Store to site including loading & unloading both ends. |
| 8 | 33KV XLPE cable (3x300sqmm) layiing along with cost of digging bricks & sand as per Respo norms |
| 9 | Errection of 11 kv XLPE cable (3x300) sqmm in AIR on D/P & make looping including fixing with clamp as per resspo norms. |
| 10 | Laying, lifting & Stringing of 33KV XLPE cable (3x300sqmm) in Air as per Resspo norms. |
| 11 | Safe Carriage of 11KV XLPE cable 3x300 sqmm from PVVNL, Store to site including loading & unloading both ends. |
| 12 | 11 KV XLPE cable (3x300sqmm) layiing along with cost of digging bricks & sand as per Respo norms |
| 13 | Safe Carriage of 11KV XLPE cable 3x185 sqmm from PVVNL, Store to site including loading & unloading both ends. |
| 14 | 11 KV XLPE cable (3x185sqmm) layiing along with cost of digging bricks & sand as per Respo norms |
| 15 | Errection of 11 kv XLPE cable (3x185) sqmm in AIR on D/P & make looping including fixing with clamp as per resspo norms. |
| 16 | Laying, lifting & Stringing of 11KV XLPE cable (3x300sqmm) in Air as per Resspo norms. |
| 17 | Laying, lifting & Stringing of 11KV XLPE cable (3x185sqmm) in Air as per Resspo norms. |
| 18 | Providing & Fixing of MS Channel 100x50x6 mm as per Resspo norms. |
| 19 | Filling of 11 KV XLPE cable O/D & I/D Jointing Kit (3x300/3x185) sqmm as per Resspo norms. |
| 20 | Filling of 33 KV XLPE cable O/D & I/D Jointing Kit (3x300) sqmm as per Resspo norms. |
| 21 | Fixing of 33 KV Fuse set with making structure, plint & painting (Channel Angle paint provided by contractor) |
| 22 | Providing & Fixing MS Holding Clamp with nut bolts as per Resspo norms. |
| 23 | Providing & Fixing PG Clamp Panther to Panther |
| 24 | Providing & Fixing Lug for Panther conductor |
| 25 | Providing & Fixing nut bolts as per Resspo norms. |
| 26 | Providing & Fixing of GI Pipe 6\\" Dia as per Resspo norms. |
| 27 | Providing & Fixing of copper Bus Bar 2.4 meter Long |
| 28 | Fixing of 11kv polymeric Pin insulator as per Resspo norms. |
| 29 | Installation of 33 KV main isolator as per resspor |
| 30 | Outdoor bus line and 11 KV VCB overhauling |
| 31 | Delta Earthing of 33 KV Fuse Set |
| 32 | Work of swich yard earth filling/stone turfing/trunch repairing |
| 33 | Dismentling of ST Pole/line/conductor & other equipment etc. |
| 34 | Carriage of dismentling line meterial form site to PVVNL Sotre |
| 35 | Water level Earthing of equipment by boaring & fixing of 60 ft. deep G.I. Pipe of class 'B' 1.5 dia and connected with G.I. strip of size 30x5 mm including providing required charcoel & salt as per Respo norms. Please Enable Macros to View BoQ information |