Tendering Authority Hll Lifecare Limited
Tender No HLL/CMO/HCD/MPB/AP/26-27
Tender ID 2026_HLL_278494_1
Tender Brief Tender For Civil & Electrical - Estimate For The Construction Of Multi Purpose Building At Aiims Mangalagiri
City Guntur
State Andhra Pradesh
Document Fees INR 2950 /-
EMD INR 1005600.0 /-
Tender Value INR 4.02 Crore /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Civil & Electrical - Estimate For The Construction Of Multi Purpose Building At Aiims Mangalagiri

Key Dates

Publish Date 22-05-2026
Last Date of Bid Submission 30-05-2026
Tender Opening Date 01-06-2026

Contact Information

Company Name Hll Lifecare Limited
Contact Person ASSOCIATE VICE PRESIDENT
Address HLL Lifecare Limited, HLL Bhavan, No26/4, Tambaram-Velachery Main Road, Pallikaranai, Chennai 600 100, Tamilnadu

BOQ Items

Name of Work:- Civil & Electrical - ESTIMATE FOR THE CONSTRUCTION OF MULTI PURPOSE BUILDING AT AIIMS MANGALAGIRI
Sl. No. Item Description
1Civil Work
2SITE CLEARENCE
3Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared.
4EARTH WORK EXCAVATION
5Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
6Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m
7Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge
8Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil
9PLAIN CEMENT CONCRETE
10Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
11Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work above plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
12Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
13RCC WORK
14Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge.All work upto plinth level.
15Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 400 kg/ cum.All work above plinth level upto floor V level
16Providing concrete grade 1:5:10 upto floor V level to cast Dummy columns to cover the projecting reinforcement of columns just below finished floors (for a length equal to lap length in compression but not less than 24d) to lap reinforcement for future vertical extension of columns for subsequent floors so as to prevent rusting/corrosion of bars due to environmental influences. It should be ensured that the columns so casted will cover the full height of projecting bars and no part shall left uncovered. The concrete in Dummy columns so casted will be demolished prior to vertical extension of columns is susequent floors.
17Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size).
18Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete below plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
19Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
20FORM WORK
21Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete
22Centering and shuttering including strutting, propping etc. and removal of form for Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
23Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform
24Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers
25Centering and shuttering including strutting, propping etc. and removal of form for : Edges of slabs and breaks in floors and walls Under 20 cm wide
26Centering and shuttering including strutting, propping etc. and removal of form for : Stairs, (excluding landings) except spiral-staircases
27Centering and shuttering including strutting, propping etc. and removal of form for : Edges of slabs and breaks in floors and walls Under 20 cm wide
28Centering and shuttering including strutting, propping etc. and removal of form for : Weather shade, Chajjas, corbels etc., including edges
29STEEL WORK
30Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
31Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
32Providing at all heights, levels and locations Aluminium profile industrial troughed sheet of Alloy 31500/31000/40800, conforming to IS 1254, IS 737, IS 2676. The sheet shall be fixed using self drilling/ self tapping SS screws of size 5.5x65 mm with EPDM seal complete upto required pitch in horizontal, vertical or curved surfaces i/c cutting to size and shape where required as per specifications, detail drawings and direction of Engineer-in-Charge. The rate shall be inclusive of all screws, seal, ridge, labour, scaffolding, machinery for fixing and approved sealent where required etc. but excluding the cost of purlins, rafters and trusses 0.71 mm thick, the profile detail width 1044/920 mm, cover width 1000/875 mm.
33Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces
34STONE WORK
35Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
36MASONRY WORK
37Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
38Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:4 (1 cement : 4 coarse sand)
39Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand)
40PLASTERING
4112 mm cement plaster of mix 1:4 (1 cement: 4 fine sand)
426 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand)
43DOORS & WINDOWS
44Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Sal wood or other similar quality wood
45Providing 40x5 mm flat iron hold fast 400 mm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 300x100x150 mm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
46Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.
4730 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required Colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames.
48Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
49Extra for providing ISI marked Stainless Steel butt hinges instead of M.S. pressed butt hinges bright finished of required size with necessary screws. (Shutter area to be measured)
50Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 150x10 mm
51Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 200x10 mm
52Providing and fixing bright finished brass handles with screws etc. complete: 125 mm
53Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.
54Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm) with double speed adjustment with necessary accessories and screws etc. complete.
55Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality for aluminium door, with necessary screws etc complete as per direction of Engineer- in-charge.
56Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerancein dimension i.e. in depth & width of profile shall be acceptable.Casement window double panels with S.S. friction hinges (300 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window above 0.75 sqm upto 1.50 sqm).
57Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm)
58Providing and fixing casement handle made of zinc alloyed (white powder coated) for uPVC casement window with necessary screws etc. complete.
59Providing and fixing of vertical/roller blinds width 100 mm regular quantity made from 100 % polyster/Fibre yarn coated with fade resistant polymer to ensure complete opaquety with zero light transmittance, having suitable coating on exterior, including all fixtures and fittings complete in all respect as per design and instruction of Engineer in-charge and as per site conditions. The colour will be approved by the competent authority Make-MAC/VISTA/NOVA or any equivalent make.
60Providing and fixing of glass door SS Patch Lock with out handle in toughened glass door including all necessary screws etc. complete.
61Providing and fixing Steel S.S- 304 (D) Door Pull Both Side Handle of 12 inch, one Set (2 Handles) ( best make of approved quality ) for Glass, Wooden or similar doors including necessary cutting and making good etc. complete
62Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double action hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-incharge (Door handle, lock and stopper etc.to be paid separately).
63Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc
64Providing and fixing glazing in door, window, ventilator shutters and partitions etc. with EPDM rubber /neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): toughened glass of 6 mm thickness.
65Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free,straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron)
66WALL TILE
67Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600mm
68Providing and fixing first-quality vitrified glazed wall tiles of approved make and size 300 × 600 mm, as approved by the Engineer-in-Charge, in skirting, step risers, and dado areas. The tiles shall be laid over a 12 mm thick cement mortar bed in the proportion of 1:3 (1 cement : 3 coarse sand). Joints shall be filled using grey cement slurry at the rate of 3.3 kg per sqm, and finished with white cement pointing mixed with matching pigment, complete in all respects.
69FLOORING
70Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm
71Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 600x600 mm
72Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of size of Tile 600 x 600 mm
73Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joint treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade. Area of slab over 0.50 sqm
74Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/ Granite/ stone work including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
75Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.
76Chequered terrazo tiles 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) : Dark shade pigment using ordinary cement
77FALSE CEILING & CLADDING
78Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer’s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made withframe of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with 12.5 mm thick tapered edge gypsum moisture resistant board
79Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer’s ecification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks)
80Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.
81PAINTING
82Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
83Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
84Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
85Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm
86Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
87Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm)
88PLUMBING & SANITARY FITTINGS
89Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
90Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms
91Providing and fixing PTMT liquid soap container 109mm wide, 125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour. weighing not less than 105 gms.
92Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 10 Kgf/cm2- External work - Exposed on wall
93Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10 Kgf/cm2 - External work- Exposed on wall
94Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 10Kgf/cm2 - External work - Exposed/ Concealed on wall
95Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 :15mm nominal bore
96Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid
97Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap
98Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour.
99Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Flexible pipe 40 mm dia
100Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge
101Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 15 mm nominal bore
102Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 15 mm nominal bore
103Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :15 mm nominal bore
104Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690gms. 15 mm nominal bore
105Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal outer dia Pipes
106Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal outer dia Pipes
107Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.50 mm nominal dia Pipes
108Constructing masonry chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C.I. surface box 100x100x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design: 18.32.1 With common burnt clay F.P.S. (non modular ) bricks of class designation 7.5
109Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
110Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour.20 mm nominal bore, weighing not less than 40 gms
111Providing and fixing CP grating of 6mm thick with rim including setting in floor with white cement mortar and making good the floor :125 mm dia
112Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall
113Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2
114Supplying and placing of 5000 Litre 1mm thick stainless steel water tank of 1750mm dia , 2600mm height, Stainless steel mounted stand around 180kg and grade of ASTM A240 gr.304/ SS316 BA/2B as per the direction of Engineer in-charge. The rate inclusive of all the transportation, Steel stand support, loading and unloading charges, fixing charges, Labour charges, etc. Nothing shall be additionally paid in this item.
115SIGNAGES
116Design, providing and fixing Digital Printed vinyl signage boards with transparent 3mm acrylic Sheet with 4 nos. SS Studs of Size 16\\" x 10\\". Complete as per the per the direction of Engineer in charge.
117Design, providing and fixing Acrylic LED Sign Board of 5cm Letter Thickness 20 - 30cm Letter Height. Complete as per the direction of Engineer in charge.
118ELECTRICAL WORKS
119Point wiring in PVC conduit with modular type switch:
120Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group B
121Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group C
122Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group C
123Wiring for twin control light point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
124Wiring through PVC conduit:
125Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
126Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
127Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
128Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
129S/F PVC Conduit:
130Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm
131Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
132Modular boxes, bases & cover plate:
133Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm)
134Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 3 Module (100mmX75mm)
135Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 6 Module (200mmX75mm)
136Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )1 module moulded plastic box on surface
137Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 1 or 2 Module
138Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant ) 3 module moulded plastic box on surface
139Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 3 Module
140Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant ) 6 module moulded plastic box on surface
141Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 6 Module
142Supply, Fixing, testing and commisisoning of 4 module Matt black finish pop up box with slim design for perfect integration into furniture equipped with three number 6A socket and one number CAT 6 data socket and one number HDMI socket supplied along with installation kits for table tops and all accessories as required for complete installation including making good any damages made, as instructed by engineer in charge, providing connections etc as required. (Legrand Arteor or equivalanet)
143Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
144Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
145Modular type switch/socket:
146Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch
147Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 A socket outlet
148Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 A switch
149Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 A socket outlet
150Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A SP switch with indicator
151Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket
152DB Accessories:
153Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 6 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)
154Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used (where 3 phase outlets are required.) 4 way (4 + 12), Double door
155Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 8 way (4 + 24), Double door
156Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 6 way (4 + 18), Double door
157Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 4 way (4 + 12), Double door
158Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 16 way, Double door
159Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way , Double door
160Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 16 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL
161Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A
162Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A
163Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker with overcurrent protection (RCBO), having a sensitivity current up to 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25A-40A, 4P, 30mA.
164Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole
165Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 A
166Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole
167Supplying and fixing 40A / 63A, TP MCB, 415 Volts, \\"C\\" curve, miniature circuit breaker in the existing MCB DB complete with connections, testing and commissioning etc as required.
168Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
169Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25 amps 415 volts \\"C\\" curve DP Isolator complete with connections, testing and commissioning etc. as required.(for UPS IN AND OUT)
170Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.32/40 Amps
171Supplying and fixing FP CRCA sheet steel enclosure with provision to mount MCB/Isolator/RCCB/RCBO and other modular devices on surface/ recess complete with connections, testing and commissioning etc. as required.
172Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
173PANEL:
174Metering Panel :-Supply, Installation, Testing and Commissioning of 415 V 50Hz OEM design verified LT Switch board complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet,Ingress Protection rating shall be IP42, Impact protection shall be IK10 & form of construction 3B or better. Cable entry facility shall be at top or bottom (as per site condition) with necessary cable alleys, switchgear compartments, meter chambers, C.T chambers, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with appropriately rated HRC fuses. Doors shall be earthed as per standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Gland plates shall be 3mm thick and knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum up to 1800mm from the finished floor level. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. OEM certification is also mandatory. Incomers - 160A TPN Isolator - 1No. 25 x 10 Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. RYB phase indicating LED lamps with control fuses and switches - 1 set. Outgoing Consumer service unit consisting of 1 Nos. 100A FP MCB, 2 Nos. 63A FP MCB & 5 Nos. 40A FP MCB. 100A, 63A and 40A fuse unit & eight numbers three phase energy meter and the meter shall be tested and approval shall be taken from EB/EI including all accessories required for complete installation and its inter connections etc
175EARTHING:
176Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required.
177Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
178Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
179Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 6 SWG)
180Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG)
181Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 10 SWG)
182Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required.
183SUPPLY AND LAYING OF LT CABLES:
184Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 185 sq mm
185Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3.5 core 185 sq mm
186Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp
187Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp
188Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp
189Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 10 sq mm with factory made clamp
190LT CABLE TERMINATION:
191Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 185 sq. mm (57mm)
192Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 35 sq. mm (32mm)
193Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 16 sq. mm (28mm)
194Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 10 sq. mm (25mm)
195Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 2 X 10 sq. mm (19mm)
196CABLE TRAYS
197Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers GI Suspenders i/c base of suitable size GI angle, GI bolts & nuts, fastner etc as required. 100 mm width X 50 mm depth X 1.6 mm thickness
198Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"bends\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers GI Suspenders i/c base of suitable size GI angle, GI bolts & nuts, fastner etc as required. 100 mm width X 50 mm depth X 1.6 mm thickness
199Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"Tee\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers GI Suspenders i/c base of suitable size GI angle, GI bolts & nuts, fastner etc as required. 100 mm width X 50 mm depth X 1.6 mm thickness
200Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"Cross member\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers GI Suspenders i/c base of suitable size GI angle, GI bolts & nuts, fastner etc as required. 100 mm width X 50 mm depth X 1.6 mm thickness
201LIGHT FITTINGS & FANS:
202LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operatingvoltage AC 140-270 Volt, frequency 50/60 hz,Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuitprotection, THD < 10% , P. F.≥0.95, IP20, CRI >80,UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained tilllife ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum powerconsumption should not more than the specifiedrating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housingsuch that LED junction temperature shall not riseabove 90°C).Powder coated die cast /Extruded aluminiumBody (Thickness > 1.20 mm) 36 watt
203LED Down lighter (SMD Type) (System lumen efficacy ≥ 105 < 120 lm/Watt ) Supplying, Installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -50C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim Powder coated die cast /Extruded aluminium Body including trim .18 watt
204LED Down lighter (SMD Type) (System lumen efficacy ≥ 105 < 120 lm/Watt ) Supplying, Installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -50C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim 8 - 10 watt
205LED Batten light (System lumen efficacy ≥105 <120 lm/Watt). Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till lifeends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation 45 DELHI SCHEDULE OF RATES (E&M)-2025 Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) 18- 22 Watt
206SITC of 2 feet surface/suspended mounted LED batten type luminaire with a power consumption not more than 10 W, luminaire lumen output of 1100 lumens, luminaire efficacy > 110 lm/W with an operating voltage range from 140 V - 270 V. The luminaire shall have a sleek design with extruded aluminum section, white CRCA housing with optically efficient poly carbonate diffuser to provide uniform illumination and wider light distribution. The luminaire shall have a CCT of 4000K /6500 K, CRI > 80, power factor >0.95, SDCM < 5, THD <10%. The luminaire shall be EMI/ EMC compliant and shall have an internal surge protection of 3 kV with 50,000 burning hours as per L70B50 criteria. The luminaire and driver shall be BIS approved and test certificates of LM79 and LM80 reports from NABL accredited labs. The luminaire shall have flicker content <5% and shall have high and low cut off with auto restart feature, including all accessories necessary as required to complete installation.
207SITC of 10W LED BULKHEAD LIGHT fixture , System efficacy>=100 lm/W and system lumen output not less than 1000 lm. , driver with minimum 2.50 KV internal surge protection with electronic drive system, power factor >0.95, THD<10%, rated life of 50,000 hours at L70 with a CRI > 80, SDCM<5 and CCT in between 4000K to 5700K. ANSI rated LEDs from reputed makes should be provided and including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. all necessary accessories as required for the light fixture.LM79, LM80, type test certificate & BIS certificate shall be submitted, Luminaire/Drive shall be BIS approved of same make
208SITC of 30 Watts Ip-65 Bis Approved Waterproof Rectangular Outdoor Arm Light,Shape Rectangular.Material-Aluminium,Finish Type-Powder Coated,,IP65 Rating (Waterproof), CRI : >80%, Premium quality, LED : 100-120lm/w, CCT - 6000-6500K (Cool White)
209Supplying and fixing of required length 32 mm dia G.I. Pipe (light class) including painting etc. as required.
210Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
211SITC of Exhaust Fan Celling mounted type with flexible horse of required length and vent cowl as bird net,Tubular Ventilating Ceiling Mounted Fan or equivalent with its all accessories including mounting accessories.
212SITC of 250mm sweep Exhaust Fan, 900rpm light duty exhaust fan shutter type white colour, 9\\" or 10\\" star rated as per BEE, with its all accessories including mounting as required for complete installation.
213PUMP SET
214Supply & Installation of Open well water pump and control panel of approved make including cost of labour, and material required for completion of work, capacity 3 HP
215S & F Motor starters of the following ratings Three phase DOL starters for 0.25HP to 7.5 HP motor
216Supply installation, testing and commissioning of following single phase to single phase UPS with battery backup, indoor (IP20) in stand alone configuration, true online double conversion DSP based UPS system, with 30 min backup battery with, input pf>.9, less input current consumption, with input 230V single phase, output 230V single phase , IGBT rectifier and IGBT inverter. It shall be 100% generator compatabile with efficiency > 90% and output power factor > 0.8 and including all accessories etc as required. The UPS system shall be with manual maintenance bypass switch facility. The system shall comply to IEC /EN 62040-1 and relevant IS standard and.The acoustic noise of the system should be less than 58dB. The system shall comply to IEC /EN 62040-1, EN/IEC 62040-2, EN/IEC 62040-3 and relevant IS standard. 2kVA UPS - 1 Nos, Battery Circuit Breaker-1 nos, Battery Required nos. of SMF for providing 30Minutes Backup and Battery Accessories like battery rack, interconnecting cables etc.
217Supply installation, testing and commissioning of following single phase to single phase UPS with battery backup, indoor (IP20) in stand alone configuration, true online double conversion DSP based UPS system, with 30 min backup battery with, input pf>.9, less input current consumption, with input 230V single phase, output 230V single phase , IGBT rectifier and IGBT inverter. It shall be 100% generator compatabile with efficiency > 90% and output power factor > 0.8 and including all accessories etc as required. The UPS system shall be with manual maintenance bypass switch facility. The system shall comply to IEC /EN 62040-1 and relevant IS standard and.The acoustic noise of the system should be less than 58dB. The system shall comply to IEC /EN 62040-1, EN/IEC 62040-2, EN/IEC 62040-3 and relevant IS standard. 3kVA UPS - 1 Nos, Battery Circuit Breaker-1 nos, Battery Required nos. of SMF for providing 30Minutes Backup and Battery Accessories like battery rack, interconnecting cables etc.
218Supply installation, testing and commissioning of following single phase to single phase UPS with inbuilt battery backup, indoor (IP20) in stand alone configuration, true online double conversion DSP based UPS system, with min 15 min backup battery with, input pf>.9, less input current consumption, with input 230V single phase, output 230V single phase , IGBT rectifier and IGBT inverter. It shall be 100% generator compatabile with efficiency > 90% and output power factor > 0.8 and including all accessories etc as required. The UPS system shall be with manual maintenance bypass switch facility. The system shall comply to IEC /EN 62040-1 and relevant IS standard and.The acoustic noise of the system should be less than 58dB. The system shall comply to IEC /EN 62040-1, EN/IEC 62040-2, EN/IEC 62040-3 and relevant IS standard. 5kVA UPS - 1 Nos, Battery Circuit Breaker-1 nos, Battery Required nos. of SMF for providing 15Minutes Backup and Battery Accessories like battery rack, interconnecting cables etc.
219DOCUMENTATION AND APPROVAL:
220DOCUMENTATION AND APPROVAL - \\"Charges for Preparation of all drawings submitting and getting approval from EB, submitting of Completion certificates and arranging inspection, getting sanction from EB/EI, obtaining power allocation if necessary & power connection etc. for commissioning of the whole installation in the premises. All statutory payments will be reimbursed on production of the original receipts
221ELV WORKS
222CCTV:
223Supplying Installation Testing and Commissioning of 2MP Fixed Lens IP IR Outdoor Bullet Camera havingfollowing specifications and features etc :-1) Signal System: PAL/NTSC, Signal to Noise Ratio: >50 dB,Camera should display Camera title, Date &Time in live & recorded video 2)Image Sensor: 1/2.8\\" or better progressive Scan CMOS to get color image even at nightcondition(Minimum Illumination: 0.006 Lux@ F1.4,AGC ON, 0 lux with IR or better) True Day & NightHigh Performance Mechanical IR cut filter with autoswitch, Integrated IR Source (Auto, Manual)- InbuiltSmart IR LED's with effective distance upto 50 meteror better and 30 meter for colour view in night,Imaging: 1/3s to 1/30000s electronic shutter support,Auto Gain Control , White Balance- Auto, Back LightCompensation, Multi zone Privacy Masking, HLC,Digital Watermarking.3) Compression (Minimum):-Video:- H.265 or better,H.264H, H.264, Audio:- G.711U/A, G.711Mu, G.726,AAC, G.7234) Wide Dynamic Range:- WDR (120db or more)5) Digital Noise Reduction:- DNR (3D) On/Off6) Video Streaming & Frame Rates :- Triple streaming, configurable(Main stream: 2MP (1920 ×1080)@25/30 fps Sub streams minimum:720P@25/30 fps).7) Image Setting: Rotate Mode, saturation, brightness,contrast, sharpness adjustable through client softwareor web browser, Edge Analytics: Tripwire, Intrusion,Motion Detection8) Cyber Security: AES 256-bit Encryption,Configuration encryption, trusted execution, Digest,security logs, account lockout, syslog, videoencryption, IP/MAC filtering, HTTPS, trusted upgrade,trusted boot.9) Onboard Storage: Camera should support built-inMicro SD/SDHC/SDXC Card slot upto 512 GB. Itshould be supplied with minimum 128GB memoryCard.10) Recording Management: Format SD, overwrite,storage management, video to NAS device,11) Alarm Trigger : Motion/tampering detection; audiodetection; network disconnection detection; IP conflictdetection; memory card state detection; memoryspace detection12)Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP,NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE,NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS,unicast,13) System Capability: ONVIF, Camera shall supportopen source VMS 2MP @ 25/30fps@1080P (1920×1080) Outdoor Bullet Camera with 2.8/ 3.6mm fixed lens
224Supplying Installation Testing and Commissioning of 2MP IP IR Dome Camera having followingspecifications, type of lens and features etc :-1) Signal System: PAL/NTSC, Signal to Noise Ratio:>50 dB, Camera should display Camera title, Date &Time in live & recorded video2)Image Sensor: 1/2.8\\" or better progressive ScanCMOS to get color image even at night condition(Minimum Illumination: 0.006 Lux@ F1.4, AGC ON, 0 lux with IR or better) True Day & Night High Performance Mechanical IR cut filter with auto switch, Integrated IR Source (Auto, Manual)- Inbuilt IR LED's with effective distance upto 50 meter or better and 30 meter for colour view in night, Imaging: 1/3s to 1/30000s electronic shutter support, Auto Gain Control , White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking. 3) Compression (Minimum):-Video:- H.265 or better,H.264H, H.264, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.723 4) Wide Dynamic Range:- WDR (120db or more)5) Digital Noise Reduction:- DNR (3D) On/Off6) Video Streaming & Frame Rates :- Triple streaming, configurable (Main stream: 2MP (1920×1080)@25/30 fps,Sub streams minimum:720P@25/30 fps).7) Image Setting: Rotate Mode, saturation, brightness,contrast, sharpness adjustable through client softwareor web browser, Edge Analytics: Tripwire, Intrusion,Motion Detection8) Cyber Security: AES 256-bit Encryption,Configuration encryption, trusted execution, Digest,security logs, account lockout, syslog, videoencryption, IP/MAC filtering, HTTPS, trusted upgrade,trusted boot.9) Onboard Storage: Camera should support built-inMicro SD/SDHC/SDXC Card slot upto 512 GB. Itshould be supplied with minimum 128GB memoryCard.280 10) Recording Management: Format SD, overwrite, storage management, video to NAS device 11) Alarm Trigger : Motion/tampering detection; audio detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection 12)Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE,NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS,unicast13) System Capability: ONVIF, Camera shall supportopen source VMS14) Ethernet: 1 RJ 45 10/100 Ethernet port15) Audio : It should support 1 x Built-In Mic and 1/1Alarm In/ Out for External Mic. and Speakers as persite requirement.16) Power Input: The camera should supportsimultaneous dual power input—12 VDC (via poweradapter) and PoE (802.3af)—to ensure continuousoperation in the event of a failure in one power source.17) Power Requirement: 12VDC/24 VAC/PoE(802.3af)/ePoE18) Housing/ Enclosure:- IP67 weather proof, IK10, Metallic body 19) Operating Condition:- Ambient Temperature:- (- )05°C to 50°C, humidity 95% (max) (non-condensing) 20) IR life: 40000 hours or higher 21) Video Bit rate: 32 KBPS - 8 MBPS or better22) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS 2MP (@ 25/30fps@1080P (1920×1080)) IP IR Dome Camera with 2.8/ 3.6mm fixed lens
225SITC Of Finolex co-axial 3+1 Copper CCTV Cable with more than 100% conductivity,with low signal loss, sharp picture & clear sound. In-House formulated & manufactured special grade FR PVC compound. (Brand Finolex)
22616 Channel Network Video Recorder (NVR) having display split :- Main screen: 1/4/8/9/16, 2nd screen: 1/4/8/9/16
227Supplying, Installation, Testing and Commissioning following capacity Serveillance grade Hard Disk with upto 256MB/s Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3.5 inch form factor, SATA Interface, BSMI, ICES-003/NNB-003, CE, FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL Certifications.
228SITC Of 16 Channel Power Supply with Input of 200-240VAC 50-60Hz, 3.5A Max and Output Voltage 12VDC 20A with metal Housing Desktop/Wall Hanging
229SITC OF 4U Rack with PDU unit with Suitable for all type of DVR Box & Double DVR / Network Switch / Server Rack with 4 Power Socket & Cable , Tray (1No) - 1 Cooling Fan Lock & Key.
230DC Connector Screw Type
231NETWORK:
232Supplying, Installation, Testing and commissioning of CAT6A Copper Information Outlet (IO) with face plate of color as per site requirement, should have ETL/ULverification program certificate for compliance with ANSI/TIA-568.2-D. All copper Cable and Components should be from same OEM to maintain compatibility and interoperability etc. complete as required.
233Supplying, drawing, Testing and commissioning of Cat6A UTP 4 pair, 23 AWG solid copper cable in existing conduit/ on surface, U/FTP, LSZH, Non- Plenum, Horizontal (solid) Cable suitable for high speed data networking application supporting upto 10Gbps over a 100 meter channel. The 4 Unshielded Twisted Pairs (UTP) cable with color coded insulation for easy indentification should have FLAME PROPERTIES i.e. Flammability Test - IEC 60332-1, Smoke Density - IEC 61034, LSZH standards compliance: ANSI/TIA-568 C.2, ISO/IEC 11801, IEEE 802.3an, RoHS. Delay Skew should be < 45NS. The outer Cable Diameter should be 7.5 + 2 mm. Cable should have been tested and verified by UL/ ETL etc. complete as required. 1 Run of cable
234Supplying, Installation, Testing and commissioning of RJ45 Connector for CAT 6/6A Cables. RJ45 modular plug supports 4 twisted pairs, 8 positions, 8 connectors. Housing: PC, UL94V-2, transparent color, Use for 24- 26 AWG stranded wires etc. complete as required.
235Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm ToughenedGlass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required. 6U rack
236Supply, Installation, Testing & Commissioning of 16 Port Network Switch with 16 No's of 10/100/1000 ports and 2 Gigabit Copper/ SFP Combo ports for uplink
237Providing, laying, testing and commissioning of 15 meter long High Speed HDMI Cable conforming to HDMI 2.0/2.1 standards, capable of transmitting Ultra HD 4K video and digital audio signals, supporting minimum 18 Gbps bandwidth, Ethernet, ARC and HDR features, with male HDMI connectors at both ends, suitable for connection between computer/laptop/media source and LED display/projector/TV, complete with all accessories as required.
238TELEPHONE
239Supply of User Phone- Analog phone
240SITC Of EPABX System of 16 lines extendable to 24 lines, No. of Junctions -4, Console Operator-1, ISDN Compatible. Extendable to 24 intercom connection; Internal/External Music on Holding, Operator/Auto-attendant, Mode, Remote Programming, Day/Night Mode (Manual), Music and Ringing Recordable, OGM (outgoing message), Music Duration 20 Seconds, Caller ID, Call Transfer, Call Forwarding Manually, Outgoing. Call Transfer, Power Failure Transfer, Specific Main Line. (CO/Trunk Line) Dialing, Three Way Conference, Do Not Disturb, Auto/Manual Dial-Out Mode, Type: Digital, Analog, Temperature Range : 0-50, Operating Humidity: 0-95%, Non Condensing
241Supplying and drawing following pair 0.5 mm dia FRLS/HFFR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair
242Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet
243FIREFIGHTING WORKS
244TERRACE PUMP AND AIR VESSEL
245Supplying, installation, testing and commissioning of electric driven terrace pump conforming to IS 12469: 2019 suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)(b) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal as required.(c) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-12615: 2018.(d) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. (e) Suitable cement concrete foundation dulyplastered and with anti vibration pads.450 lpm at 35m Head
246supplying and fixing air vessel made of 250 mm dia 8 mm thick MS sheet , 1200 mm in height with Air release valve on top and flanged connection to riser , drain arrangement with 25 mm dia Gun metal wheel valve with required accessories , pressure guage and painting with synthetic enamel paint of approved shade as required.
247Power Control Panel- Supply, Installation, testing and commissioning of combined type automatic motor control panel with necessary star delta starters, indication lamps etc. for terrace fire pumps
248PIPE AND ACCESSORIES
249Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.a) 20 mm nominal Internal dia water hose thermoplastic(Textile reinforced) type-2 as per IS:12585b) 20 mm nominal internal dia gun metal globe valve &nozzlec) Drum and brackets for fixing the equipments on wall.d) Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.30 m
250Providing, laying, testing and commissioning of C class heavy duty M S Pipe conforming to IS 3589,IS 1239 i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required:50 mm dia
251Providing, laying, testing and commissioning of C class heavy duty M S Pipe conforming to IS 3589,IS 1239 i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required:100mm dia
252VALVES ,SWITCHES AND GAUGES
253Supplying, fixing, testing and commissioning of Butterfly Valve of PN 1.6 rating with bronze or gun metal seat duly ISI marked complete with nuts, bolts ,washers,gaskets conforming to IS 13095 of following sizes as required:100 mm dia
254Providing,installation,testing and commissioning of non-return valve of following sizes conforming to IS :5312 complete with rubber gasket, GI bolts , nuts, washers etc as required.100 mm dia
255Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required
256Providing, installation ,testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel , Grade 304,sheet with3 mm dia holes with stainless steel flange.100 mm dia
257Providing and fixing of pressure switch in MS pipeline including connection etc as required:
258Providing and fixing of flow switch in MS pipe including connection etc as required:100 mm dia
259Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required:Single headed Stainless steel
260Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Stainless Steel (Grade 304)
261Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :Stainless Steel (Grade 304)
262Supply, installation, testing and commissioning of weather proof hose boxes wall/pedestal type of size 600 x 250 x 400 mm made out of 18 gauge MS sheet steel with front side glass, locking arrangement and painted with approved colour completed as required and as per specifications.
263FIRE EXTINGUISHERS
264Supplying, installing and commissioning Portable Fire extinguishers of following type & capacity.Co2 type Fire Extinguisher, made from brand new seamless Steel cylinder, as per IS: 7285 and CCE approval, fitted with Discharge hose and horn and Wheel type valve with initial Charge and mounted on Rubber Wheels / wall mounted brackets as per IS: 16018 specification, bearing ISI Mark. 4.5 Kgs
265Supply and installation of ABC Stored pressure type Fire Extinguisher 6 Kgs Capacity Mono Ammonium Phosphate based Dry Chemical Powder as per IS 14609 with ISI Mark for Fighting ABC Class of Fire, stored Pressure type of Mild steel body pressurized by Nitrogen Gas. The Extinguisher shall have pressure gauge for indicating inside pressure with opening and closing lever of squeeze grip type with tamper proof seal, complete with wall bracket. The Extinguisher should be manufactured strictly as per IS: 15683:2006 with ISI mark
266SIGNAGES
267SITC of self glowing \\"FIRE EXTINGUISHER\\" sign boards of size (150 X 150 mm) in triangular shape fixed on the wall and shall be as per IS code 9457:2005, IS 12349, IS 12407.
268Supply, installation, testing and commissioning of Fire Exit Light, Laser type, with High Glow LED, size:300x 178 x 32 mm. or 390 x190 x 60mm, Ceiling Mounting type with hanging clamps, on/off switch, Red /Green Colour option with minimum of 25 Mtr. viewing distance, power consumption: 5.0 Watt per face (maximum), with Single Side Display and shall be as per IS code 9457:2005, IS 12349, IS 12407.
269Providing and fixing in position the signage \\" FIRE ORDER\\" on 3mm thick \\"Opaque\\" PVC foam board of computerized cut, PVC non- reflective self adhesive vinyl painted foam board of 2' x 3' and shall be as per IS code 9457:2005, IS 12349, IS 12407
270Providing and fixing of Floor Identification Signage (MAIN STAIRCASE, FIRE STAIRCASE, FIRE ASSEMBLY POINT, PUMP ROOM, FIRE CONTROL ROOM, ELECTRICAL ROOM, FIRE LIFT, PASSENGER LIFT Etc.) on every floor,lettering size shall be 5 Cm. with contrasting colour from background. Size shall be 15cm x 30cm and shall be as per IS code 9457:2005, IS 12349, IS 1240
271Providing and fixing of Floor identification signage (e.g., GROUND FLOOR, FIRST FLOOR, etc.) will be placed at each stair enclosure on every floor, displaying the floor number in words. The letter size will be 5 cm, with a contrasting color to the background. The dimensions of the signage will be 15 cm x 30 cm, and it will comply IS Code 9457:2005, IS 12349, and IS 12407.
272Providing and fixing of signage : \\"IN CASE OF FIRE, USE STAIRS UNLESS INSTRUCTED OTHERWISE\\" with red letters, each 1.25 cm in height, on a white background. The board dimensions will be 25 cm x 30 cm and will be mounted at a height of 2 meters from the finished floor, positioned near manual call points. The signage will comply with IS Code 9457:2005, IS 12349, and IS 1240 standards.
273FIRE BRIGADE
274FIRE BRIGADE INLET : Supply, installation, testing and commissioning of 3 way tank filling Inlet connection of 63 mm dia. valves instantaneous coupling type arrangement to be connected to wet riser main.
275FIRE ALARM SYSTEM
276FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL)Supplying,installation, testing & commissioning of manual call boxes of MS Construction in surface/recess with stainless steel chain & hammer assembly Complete with glass and push button etc. as required.
277FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL)Supplying,installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required.
278Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required.4 Zone
279Supplying & laying of 2x1.5 sq mm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
280HVAC WORKS
281Supply, Installation, Testing and Commissioning of aircooled VRV (Variable Refrigerant Volume) / VRF (Variable Refrigerant Flow) outdoor units (ODUs) equipped with highly efficient, full DC inverterdriven scroll compressors only, aircooled heat exchangers having internally grooved copper tubes, and lownoise condenser fans. The units shall have autoaddressing, an autocheck function for connection errors, and operate with R410A or equivalent refrigerant gas. Each unit shall be fitted with a noise filter, highpressure switch, fan motor overload protector, overcurrent relay, inverter overload protector, and other necessary protective devices. Power failure of one or more IDU shall not affect operation of other units / circuit. The units shall deliver the rated capacity in accordance with IS 18728:2024 and CPWD specifications. The efficiency of the ODUs shall meet the latest ECSBC/ASHRAE standards. Suitable vibration isolators shall be provided with the ODUs. The system shall operate at outdoor conditions up to a minimum ambient drybulb temperature of 50°C. Each unit shall be equipped with an oil recovery system to ensure stable operation with long refrigeration piping lengths, and provided with an oilbalancing circuit to prevent inadequate lubrication. Compatibility with centralized control systems such as BACnet, LonWorks, and Modbus is required. The ODUs shall be suitable for a 3phase, 415V, 50Hz power supply, with suitable interconnecting control cabling between IDUs, ODUs, and the central controller. All necessary power cabling up to the ODU electrical panel, pressure testing, additional refrigerant charging for commissioning, and all associated accessories required for commissioning shall be included in the scope of work. The VRF outdoor unit circuit schedule shall be as per the tender drawings/specifications.
282Supply, Installation, Testing, and Commissioning of VRV/VRF 2.0 TR Cassette Type Indoor Ceiling Mounted Units along with a Cordless Remote. The machine should be equipped with a synthetic washable media pre-filter, a multi-speed motor, a DX copper coil, an electronic expansion valve, and an insulated drain pan as required. The unit is to be enclosed in a powder-coated cabinet. The blower shall be dynamically balanced and designed for silent operation. The address of the indoor unit shall be set automatically in case of individual and group control. The units should be suitable for operation on a single-phase, 230V, 50Hz supply. The machine should include a high-lift drain pump as necessary, a drain connection with a U-trap, and all necessary fittings, elbows, electrical cabling from the power plug, and structural supports, etc
283Supply, Installation, Testing, and Commissioning of VRV/VRF 3.2TR Cassette Type Indoor Ceiling Mounted Units along with a Cordless Remote. The machine should be equipped with a synthetic washable media pre-filter, a multi-speed motor, a DX copper coil, an electronic expansion valve, and an insulated drain pan as required. The unit is to be enclosed in a powder-coated cabinet. The blower shall be dynamically balanced and designed for silent operation. The address of the indoor unit shall be set automatically in case of individual and group control. The units should be suitable for operation on a single-phase, 230V, 50Hz supply. The machine should include a high-lift drain pump as necessary, a drain connection with a U-trap, and all necessary fittings, elbows, electrical cabling from the power plug, and structural supports, etc
284Supply, Installation, Testing, and Commissioning of VRV/VRF 4.0 TR Cassette Type Indoor Ceiling Mounted Units along with a Cordless Remote. The machine should be equipped with a synthetic washable media pre-filter, a multi-speed motor, a DX copper coil, an electronic expansion valve, and an insulated drain pan as required. The unit is to be enclosed in a powder-coated cabinet. The blower shall be dynamically balanced and designed for silent operation. The address of the indoor unit shall be set automatically in case of individual and group control. The units should be suitable for operation on a single-phase, 230V, 50Hz supply. The machine should include a high-lift drain pump as necessary, a drain connection with a U-trap, and all necessary fittings, elbows, electrical cabling from the power plug, and structural supports, etc
285Supply, Installation, Testing, and Commissioning of VRV/VRF 1.0TR high-wall type indoor unit complete with a corded/cordless remote (subject to consultant's approval). The machine shall be suitable for operation on 230 V, 50 Hz, single-phase AC supply, including all power cabling to the nearest power socket. The unit shall include a washable synthetic media pre-filter, DC fan section with a low-noise fan/dynamically balanced blower, multi-speed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, drain pan, and necessary accessories, etc..
286Supply, Installation, Testing, and Commissioning of VRV/VRF 1.6TR high-wall type indoor unit complete with a corded/cordless remote (subject to consultant's approval). The machine shall be suitable for operation on 230 V, 50 Hz, single-phase AC supply, including all power cabling to the nearest power socket. The unit shall include a washable synthetic media pre-filter, DC fan section with a low-noise fan/dynamically balanced blower, multi-speed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, drain pan, and necessary accessories, etc..
287Supply and Installation of INDOOR Refnet / Y-joint separation tubes for refrigeration pipe joints and headers in appropriate orientation to enable proper distribution of refrigerant. The distribution joints should be factory insulated with pre- formed section of expended polystyrene / equivalent.
288Supply, Installation, Testing, and Commissioning of Soft drawn Copper Pipe 19/20 Gauge with 19mm thick Insulation:1/4 inch (6.35 mm) gas/liquid copper insulated piping. The insulation for copper lines shall be round, closed-cell, antimicrobial nitrile rubber sleeve insulation. The minimum R-values of pipes shall be 0.4 for pipe sizes less than 40 mm and 0.7 for pipe sizes 40 mm and above. Insulation shall be finished with 7 mils of FACTORY LAMINATED FIBRE GLASS CLOTH. The thermal conductivity of the insulation material shall not exceed 0.035 W/(m·K) at a mean temperature of 0°C as per EN ISO 8497. The installation includes suction filters for the gas line, a filter drier, and a sight glass for the liquid line as per the specifications between each indoor and outdoor unit. The scope of work shall include chasing, drilling, core cutting, and concealing on walls, etc., as per site conditions, along with the required pipe fittings and accessories such as bends, tees, reducers, Y-joints, supports, refnets, and wall clamps, etc., for the proper commissioning of the VRF/VRV circuit. The thickness of the fittings should match the pipe thickness. PVC SLEEVES shall be securely fixed over the copper pipes to provide a protective barrier at all wall openings and along support channels. The work shall be completed in all respects as per the consultants approval. The contractor shall ensure that the pipe size and thickness of all the refrigerant pipes installed are in accordance with the Original Equipment Manufacturers (OEM) technical/recommended specifications.
289Supply, Installation, Testing, and Commissioning of Soft drawn Copper Pipe 19/20 Gauge with 19mm thick Insulation:3/8 inch (9.52 mm) gas/liquid copper insulated piping. The insulation for copper lines shall be round, closed-cell, antimicrobial nitrile rubber sleeve insulation. The minimum R-values of pipes shall be 0.4 for pipe sizes less than 40 mm and 0.7 for pipe sizes 40 mm and above. Insulation shall be finished with 7 mils of FACTORY LAMINATED FIBRE GLASS CLOTH. The thermal conductivity of the insulation material shall not exceed 0.035 W/(m·K) at a mean temperature of 0°C as per EN ISO 8497. The installation includes suction filters for the gas line, a filter drier, and a sight glass for the liquid line as per the specifications between each indoor and outdoor unit. The scope of work shall include chasing, drilling, core cutting, and concealing on walls, etc., as per site conditions, along with the required pipe fittings and accessories such as bends, tees, reducers, Y- joints, supports, refnets, and wall clamps, etc., for the proper commissioning of the VRF/VRV circuit. The thickness of the fittings should match the pipe thickness. PVC SLEEVES shall be securely fixed over the copper pipes to provide a protective barrier at all wall openings and along support channels. The work shall be completed in all respects as per the consultants approval. The contractor shall ensure that the pipe size and thickness of all the refrigerant pipes installed are in accordance with the Original Equipment Manufacturers (OEM) technical/recommended specifications.
290Supply, Installation, Testing, and Commissioning of Soft drawn Copper Pipe 19/20 Gauge with 19mm thick Insulation:1/2 inch (12.7 mm) gas/liquid copper insulated piping. The insulation for copper lines shall be round, closed-cell, antimicrobial nitrile rubber sleeve insulation. The minimum R-values of pipes shall be 0.4 for pipe sizes less than 40 mm and 0.7 for pipe sizes 40 mm and above. Insulation shall be finished with 7 mils of FACTORY LAMINATED FIBRE GLASS CLOTH. The thermal conductivity of the insulation material shall not exceed 0.035 W/(m·K) at a mean temperature of 0°C as per EN ISO 8497. The installation includes suction filters for the gas line, a filter drier, and a sight glass for the liquid line as per the specifications between each indoor and outdoor unit. The scope of work shall include chasing, drilling, core cutting, and concealing on walls, etc., as per site conditions, along with the required pipe fittings and accessories such as bends, tees, reducers, Y- joints, supports, refnets, and wall clamps, etc., for the proper commissioning of the VRF/VRV circuit. The thickness of the fittings should match the pipe thickness. PVC SLEEVES shall be securely fixed over the copper pipes to provide a protective barrier at all wall openings and along support channels. The work shall be completed in all respects as per the consultants approval. The contractor shall ensure that the pipe size and thickness of all the refrigerant pipes installed are in accordance with the Original Equipment Manufacturers (OEM) technical/recommended specifications.
291Supply, Installation, Testing, and Commissioning of Hard drawn Copper Pipe 18/19 Gauge with 19mm thick Insulation:5/8 inch (15.88 mm) gas/liquid copper insulated piping. The insulation for copper lines shall be round, closed-cell, antimicrobial nitrile rubber sleeve insulation. The minimum R-values of pipes shall be 0.4 for pipe sizes less than 40 mm and 0.7 for pipe sizes 40 mm and above. Insulation shall be finished with 7 mils of FACTORY LAMINATED FIBRE GLASS CLOTH. The thermal conductivity of the insulation material shall not exceed 0.035 W/(m·K) at a mean temperature of 0°C as per EN ISO 8497. The installation includes suction filters for the gas line, a filter drier, and a sight glass for the liquid line as per the specifications between each indoor and outdoor unit. The scope of work shall include chasing, drilling, core cutting, and concealing on walls, etc., as per site conditions, along with the required pipe fittings and accessories such as bends, tees, reducers, Y- joints, supports, refnets, and wall clamps, etc., for the proper commissioning of the VRF/VRV circuit. The thickness of the fittings should match the pipe thickness. PVC SLEEVES shall be securely fixed over the copper pipes to provide a protective barrier at all wall openings and along support channels. The work shall be completed in all respects as per the consultants approval. The contractor shall ensure that the pipe size and thickness of all the refrigerant pipes installed are in accordance with the Original Equipment Manufacturers (OEM) technical/recommended specifications.
292Supply, Installation, Testing, and Commissioning of Hard drawn Copper Pipe 18/19 Gauge with 19mm thick Insulation:3/4 inch (19.05 mm) gas/liquid copper insulated piping. The insulation for copper lines shall be round, closed-cell, antimicrobial nitrile rubber sleeve insulation. The minimum R-values of pipes shall be 0.4 for pipe sizes less than 40 mm and 0.7 for pipe sizes 40 mm and above. Insulation shall be finished with 7 mils of FACTORY LAMINATED FIBRE GLASS CLOTH. The thermal conductivity of the insulation material shall not exceed 0.035 W/(m·K) at a mean temperature of 0°C as per EN ISO 8497. The installation includes suction filters for the gas line, a filter drier, and a sight glass for the liquid line as per the specifications between each indoor and outdoor unit. The scope of work shall include chasing, drilling, core cutting, and concealing on walls, etc., as per site conditions, along with the required pipe fittings and accessories such as bends, tees, reducers, Y- joints, supports, refnets, and wall clamps, etc., for the proper commissioning of the VRF/VRV circuit. The thickness of the fittings should match the pipe thickness. PVC SLEEVES shall be securely fixed over the copper pipes to provide a protective barrier at all wall openings and along support channels. The work shall be completed in all respects as per the consultants approval. The contractor shall ensure that the pipe size and thickness of all the refrigerant pipes installed are in accordance with the Original Equipment Manufacturers (OEM) technical/recommended specifications.
293Supply, Installation, Testing, and Commissioning of Hard drawn Copper Pipe 18/19 Gauge with 19mm thick Insulation:7/8 inch (22.2 mm) gas/liquid copper insulated piping. The insulation for copper lines shall be round, closed-cell, antimicrobial nitrile rubber sleeve insulation. The minimum R-values of pipes shall be 0.4 for pipe sizes less than 40 mm and 0.7 for pipe sizes 40 mm and above. Insulation shall be finished with 7 mils of FACTORY LAMINATED FIBRE GLASS CLOTH. The thermal conductivity of the insulation material shall not exceed 0.035 W/(m·K) at a mean temperature of 0°C as per EN ISO 8497. The installation includes suction filters for the gas line, a filter drier, and a sight glass for the liquid line as per the specifications between each indoor and outdoor unit. The scope of work shall include chasing, drilling, core cutting, and concealing on walls, etc., as per site conditions, along with the required pipe fittings and accessories such as bends, tees, reducers, Y- joints, supports, refnets, and wall clamps, etc., for the proper commissioning of the VRF/VRV circuit. The thickness of the fittings should match the pipe thickness. PVC SLEEVES shall be securely fixed over the copper pipes to provide a protective barrier at all wall openings and along support channels. The work shall be completed in all respects as per the consultants approval. The contractor shall ensure that the pipe size and thickness of all the refrigerant pipes installed are in accordance with the Original Equipment Manufacturers (OEM) technical/recommended specifications.
294Supply, Installation, Testing, and Commissioning of Hard drawn Copper Pipe 18/19 Gauge with 19mm thick Insulation:1.0 inch (25.4 mm) gas/liquid copper insulated piping. The insulation for copper lines shall be round, closed-cell, antimicrobial nitrile rubber sleeve insulation. The minimum R-values of pipes shall be 0.4 for pipe sizes less than 40 mm and 0.7 for pipe sizes 40 mm and above. Insulation shall be finished with 7 mils of FACTORY LAMINATED FIBRE GLASS CLOTH. The thermal conductivity of the insulation material shall not exceed 0.035 W/(m·K) at a mean temperature of 0°C as per EN ISO 8497. The installation includes suction filters for the gas line, a filter drier, and a sight glass for the liquid line as per the specifications between each indoor and outdoor unit. The scope of work shall include chasing, drilling, core cutting, and concealing on walls, etc., as per site conditions, along with the required pipe fittings and accessories such as bends, tees, reducers, Y- joints, supports, refnets, and wall clamps, etc., for the proper commissioning of the VRF/VRV circuit. The thickness of the fittings should match the pipe thickness. PVC SLEEVES shall be securely fixed over the copper pipes to provide a protective barrier at all wall openings and along support channels. The work shall be completed in all respects as per the consultants approval. The contractor shall ensure that the pipe size and thickness of all the refrigerant pipes installed are in accordance with the Original Equipment Manufacturers (OEM) technical/recommended specifications.
295Supply, Installation, Testing, and Commissioning of Hard drawn Copper Pipe 18/19 Gauge with 19mm thick Insulation:1-1/8 inch (28.6 mm) gas/liquid copper insulated piping. The insulation for copper lines shall be round, closed-cell, antimicrobial nitrile rubber sleeve insulation. The minimum R-values of pipes shall be 0.4 for pipe sizes less than 40 mm and 0.7 for pipe sizes 40 mm and above. Insulation shall be finished with 7 mils of FACTORY LAMINATED FIBRE GLASS CLOTH. The thermal conductivity of the insulation material shall not exceed 0.035 W/(m·K) at a mean temperature of 0°C as per EN ISO 8497. The installation includes suction filters for the gas line, a filter drier, and a sight glass for the liquid line as per the specifications between each indoor and outdoor unit. The scope of work shall include chasing, drilling, core cutting, and concealing on walls, etc., as per site conditions, along with the required pipe fittings and accessories such as bends, tees, reducers, Y- joints, supports, refnets, and wall clamps, etc., for the proper commissioning of the VRF/VRV circuit. The thickness of the fittings should match the pipe thickness. PVC SLEEVES shall be securely fixed over the copper pipes to provide a protective barrier at all wall openings and along support channels. The work shall be completed in all respects as per the consultants approval. The contractor shall ensure that the pipe size and thickness of all the refrigerant pipes installed are in accordance with the Original Equipment Manufacturers (OEM) technical/recommended specifications.
296Supply, Installation, Testing, and Commissioning of Hard drawn Copper Pipe 18/19 Gauge with 19mm thick Insulation:1-1/4 inch (31.8 mm) gas/liquid copper insulated piping. The insulation for copper lines shall be round, closed-cell, antimicrobial nitrile rubber sleeve insulation. The minimum R-values of pipes shall be 0.4 for pipe sizes less than 40 mm and 0.7 for pipe sizes 40 mm and above. Insulation shall be finished with 7 mils of FACTORY LAMINATED FIBRE GLASS CLOTH. The thermal conductivity of the insulation material shall not exceed 0.035 W/(m·K) at a mean temperature of 0°C as per EN ISO 8497. The installation includes suction filters for the gas line, a filter drier, and a sight glass for the liquid line as per the specifications between each indoor and outdoor unit. The scope of work shall include chasing, drilling, core cutting, and concealing on walls, etc., as per site conditions, along with the required pipe fittings and accessories such as bends, tees, reducers, Y- joints, supports, refnets, and wall clamps, etc., for the proper commissioning of the VRF/VRV circuit. The thickness of the fittings should match the pipe thickness. PVC SLEEVES shall be securely fixed over the copper pipes to provide a protective barrier at all wall openings and along support channels. The work shall be completed in all respects as per the consultants approval. The contractor shall ensure that the pipe size and thickness of all the refrigerant pipes installed are in accordance with the Original Equipment Manufacturers (OEM) technical/recommended specifications.
297Supply, Installation, Testing, and Commissioning of Hard drawn Copper Pipe 18/19 Gauge with 19mm thick Insulation:1-3/8 inch (34.9 mm) gas/liquid copper insulated piping. The insulation for copper lines shall be round, closed-cell, antimicrobial nitrile rubber sleeve insulation. The minimum R-values of pipes shall be 0.4 for pipe sizes less than 40 mm and 0.7 for pipe sizes 40 mm and above. Insulation shall be finished with 7 mils of FACTORY LAMINATED FIBRE GLASS CLOTH. The thermal conductivity of the insulation material shall not exceed 0.035 W/(m·K) at a mean temperature of 0°C as per EN ISO 8497. The installation includes suction filters for the gas line, a filter drier, and a sight glass for the liquid line as per the specifications between each indoor and outdoor unit. The scope of work shall include chasing, drilling, core cutting, and concealing on walls, etc., as per site conditions, along with the required pipe fittings and accessories such as bends, tees, reducers, Y- joints, supports, refnets, and wall clamps, etc., for the proper commissioning of the VRF/VRV circuit. The thickness of the fittings should match the pipe thickness. PVC SLEEVES shall be securely fixed over the copper pipes to provide a protective barrier at all wall openings and along support channels. The work shall be completed in all respects as per the consultants approval. The contractor shall ensure that the pipe size and thickness of all the refrigerant pipes installed are in accordance with the Original Equipment Manufacturers (OEM) technical/recommended specifications.
298Supply, laying, and testing of shielded copper flexible communication/transmission cabling between VRF indoor units and outdoor units. The communication cable must be routed through PVC conduit. The sizing of the cable to be 2 Core x 1.5 SQMM (or) as per VRF-OEM's technical/recommended specification.
299Supply, Installation, testing and commissioning of 25mm dia rigid UPVC condensate drain pipes duly insulated with 9mm thick closed cell nitrile finished with 7mils FACTORY LAMINATED GLASS CLOTH along with necessary U-trap,clamps, fittings such as bends, tees etc. adequately supported complete as required confirming to specification.
300Supply, Installation, testing and commissioning of 32mm dia rigid UPVC condensate drain pipes duly insulated with 9mm thick closed cell nitrile finished with 7mils FACTORY LAMINATED GLASS CLOTH along with necessary U-trap,clamps, fittings such as bends, tees etc. adequately supported complete as required confirming to specification.
301Supply, Installation, testing and commissioning of 40mm dia rigid UPVC condensate drain pipes duly insulated with 9mm thick closed cell nitrile finished with 7mils FACTORY LAMINATED GLASS CLOTH along with necessary U-trap,clamps, fittings such as bends, tees etc. adequately supported complete as required confirming to specification.
302HIWALL SPLIT AC FOR ATM
303Supply, Installation, Testing and Commissioning of 1.0TR BEE 3 STAR rated INVERTER-Type Air-Cooled Hi-Wall Split-Type Air Conditioners, complete with Indoor Unit (IDU), Outdoor Unit (ODU), surface/concealed copper refrigerant piping with insulation (closed-cell elastomeric nitrile rubber tubular pipe section) up to 3 meters (IDU to ODU), copper power cable up to 3.5 meters (IDU to ODU), including drain pipe, R-32/R-410A/R-407C green refrigerant, wireless remote control, suitable for working between 180–260V with low & high voltage cutoff and 50 Hz, single-phase AC supply, capable of performing cooling, dehumidification, and air circulation of the following capacity with scroll/rotary compressor—the system shall be able to deliver 100% of the rated capacity up to 42°C. The unit must be able to operate up to 50°C (outdoor ambient temperature).WARRANTY: The system must include a MINIMUM 5-year Original Equipment Manufacturer (OEM) warranty for PCB, 10-year warranty on compressor, and 1-year warranty for the total machine. Warranty Certificate to be submitted for approval.Approved Make : Hitachi, Daikin, Toshiba, Trane, O-General, Mitsubishi Electric, Voltas, Bluestar, Carrier
304Supply and installation of automatic voltage STABILIZERS suitable for 1.0TR/1.5TR split AC units, complete with all necessary wiring, connectors, and wall mounting hardware. The stabilizer shall feature intelligent microprocessor-based control with SMT/PTH IC technology, ±1% output voltage accuracy, and startup time delay protection. It shall operate within 170V-270V AC input range (50Hz) with auto-reset low/high voltage cut-off, manual-reset thermal overload protection, short-circuit and surge protection
305Supply and installation of heavy-duty mild steel (M.S) OUTDOOR STAND for split AC units, comprising of powder-coated mounting brackets with anti-corrosion treatment including all necessary galvanized mounting bolts, nuts, washers, and anchor fasteners. Installation shall be as per manufacturer guidelines and Engineer-in-Charge’s directions, ensuring level alignment with wall/floor mounting options
306Supply and installation of insulated PVC condensate DRAIN PIPING for split AC units including wall chasing, solvent-welded joints, and complete with clamps at regular intervals. Installation shall be with adequate slope towards drainage point. Work includes all necessary bends, couplings, P-traps and termination into designated drainage system.
307Supply and installation of ADDITIONAL REFRIGERANT PIPING KIT for split AC units, comprising of Seamless copper tubing with wall thickness as per AC manufacturer's specifications, flame retardant elastomeric nitrile rubber insulation of minimum 13mm thickness all including necessary power and control cabling. Please Enable Macros to View BoQ information

Other Detail

Information Source https://etenders.gov.in/eprocure/app
Download FileName File Description File Size
Download 7e6a7e75-03f0-4f67-86a0-ae550eb42ba8.html Tender Documents 0 KB
Download BOQ_325142.xls Tender Documents 0 KB
Download TEDOMULTI1.pdf Tender Documents 0 KB
Download Tendernotice_1.pdf Tender Documents 0 KB