Indian Tenders

Tender Notice

TDR 55636159
Tendering Authority Road And Building Department
Tender No SE (R AND B) BGR/ 01/ 2026-27
Tender ID 2026_EICCL_129701_1
Tender Brief Tender For Special Repair To Laxmijore Police Station, Balangir Such As Gci Roof Top, Parking Shed And Colouring Of P.S. Building Etc For The Year 2026-27
City Balangir
State Odisha
Document Fees INR 6000 /-
EMD INR 21600.0 /-
Tender Value INR 21.56 Lakhs /-
Tender Type Tender
Bidding Type National Competitive Bid
Competition Type Indian

Tender Details

Tender for Special Repair To Laxmijore Police Station, Balangir Such As Gci Roof Top, Parking Shed And Colouring Of P.S. Building Etc For The Year 2026-27

Key Dates

Publish Date 23-05-2026
Last Date of Bid Submission 01-06-2026
Tender Opening Date 02-06-2026

Contact Information

Company Name Road And Building Department
Contact Person S.E,Balangir (R and B) Division,Balangir
Address O/o. S.E, Balangir (R and B) Division, Balangir

BOQ Items

Name of Work:- Special Repair to Laxmijore Police Station, Balangir such as GCI roof top, parking shed and colouring of P.S. Building etc for the year 2026-27
Sl. No. Item Description
1Civil Portion of Work : Earth work in excavation of foundation teachers/in all kinds of soil including moorum, stoney earth and earth mixed with boulder except sheet rocks and boulders requiring blasting including dressing and leveling the bed up to the required depth & depositing the excavated materials away from the work site with all leads & lefts top shorting & strutting if required etc. complete as directed by the Engineer-in-charge.
2Supplying and filling in foundation and plinth with sand including watering, ramming cost, conveyance & taxes materials & cost of labour with T&P required for the works etc. complete. (measurement will be taken on finished completed section only)
3Cement concrete (1:3:6) in foundation and floors using 20 mm. size black hard hand broken granite metals of approved quality and from approved quarry including lowering, laying concrete watering & curing etc. complete to required level including cost, conveyance royalties & taxes of all materials & cost of all labour with T&P required for work complete.
4Supplying fitting and fixing W.I. grills, Grills gates, M.S. gates as per approved drawing & designed including marking holes in brick & R.C.C. structures, wood work etc. and marking good to the damages to walls with cement concrete of prop 1:2:3 with black hard crusher broken granite stone chips of 12mm to 20mm size (20mm size not to exceed 25%) complete in all respects W.I. grills, gates M.S. gates screws & other required materials of approved quality will be supplied by the contractor at his own cost.
5Painting three coats in all floors (two coats with paints of approved shade and base coat with primer) to new wood /iron work including sand papering, polishing the surface with cost conveyance cost of all materials and T&P required for the work but including cost of paints and primer complete, in all respect (paints and primer to be supplied by the contractor of his own cost.)
6Supplying, fitting and fixing of G.C.I sheet in roof including, fixing of ridges, windties etc. complete including cost of G.C.I sheet and ridges of approved quality as necessary for the work including drilling holes in windties but excluding cost L-hook and washer etc. complete. G.C.I sheet and ridges of approved quality to be supplied by the contractor at his own cost.
7Supplying fitting and fixing of P.V.C Rain water drain pipe
8Supplying fitting and fixing vitrified tile in floors of size 600mm x 600mm of approved make with application of polymer modified cement based water resistant adhesive bed of required thickness of 10mm and filing joints with epoxy grout of approved quality including cost of all material taxes labour T&P etc. required for the work complete
9Providing fitting fixing of false ceiling with Aluminium anodised T section No.3215 with 2'0\\" center to center, L section No.1705 on 4 walls to be fixed by means of steel screw and P.V.C. plug and the Aluminium grid 2'0\\"x2'0\\" with water proof Gypsum board suspended from ceiling including cost of all materials, labour T&P etc required for the work all complete as per direction of the Engineer-in-charge
10Finishing surface of walls with cement based wall putty (water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials labour T & P etc. as per direction of Engineer -In -charge. in Ground Floor
11Wall painting 2 coats with plastic emulsion paint of approved shade on new work to given an even shade including cost of paint.
12Painting three coats in all floors (two coats with paints of approved shade and base coat with primer) to new wood /iron work including sand papering, polishing the surface with cost conveyance cost of all materials and T&P required for the work but including cost of paints and primer complete, in all respect (paints and primer to be supplied by the contractor of his own cost.)
13Providing, fitting and fixing of Al door with anodized Al. door section of 9202 as vertical member, 9201 as top and 9200 as middle and bottom member with frame section No.9221 and tapered clip no. 4660 and the frame to be completed by means of jointing angle no. 1855 including all cost of labour, T&P, hire charges of drilling machine, labour charges , etc. complete as per direction of the Engineer-in-charge
14Supplying, fitting fixing of 5 mm thick Plain glass in position in wooden, steel/ Aluminum frame of door, window & ventilator including cutting to size with cost of all material ,labour, T&P etc complete as per direction of E.I.C.
15Supplying Fitting, fixing up fully glazed aluminium framed window (sliding type) made up aluminium section 9778 as window frame, section 4095, 4096 and 9777, 3994 as shutter frame with 5mm black glass as panel fitted with rubber beading including locking arrangement including all fitting including cost of all materials, all taxes, labour, T&P excluding cost of glass etc. complete as per direction of the Engineer-in-charge
16Painting two coats with weather coat paint over a coat of primer of approved shade by means of brush after cleaning the surface including watering and curing etc. complete using weather coat paint to be supplied by the contractor of his own cost, including cost of weather coat paint and all materials with all taxes, royalty, labour and T&P required for the work etc. complete.
17Distempering two coats with any approved shade in all floors including cost conveyance taxes of all materials and T&P required for the work etc. complete including cost of distemper (Distemper of approved quality will be supplied by the contractor at has own cost)
18Supplying, fitting & fixing Big Six or Trafford A.C. sheet in roof, including fixing of ridges wind ties etc. complete including cost of A.C. sheet and ridges of approved quality as necessary for the work including drilling holes in wind ties but excluding cost of L-hook and washer etc. complete (A.C. sheet & ridges of approved quality to be supplied by the contractor at his own cost.)
19Fly ash brick masonry in cement mortar (1:6) in superstructure using of (23cm x 11cm x 8 cm) size having minimum crushing strength not less than 75 kg.per.sq.cm. including splays cutting, circular moulding, chamfering, corbelling and similar such type of woks with all necessary projections. Watering and curing for 7 days and immersing the bricks in water for six hours before use etc. complete including cost and conveyance of all materials, labour with T&P required for the work with all taxes and royalties etc. complete in all respect as per direction of Engineer in charge.
2012 mm(½”) thick cement plaster (1:6) finished smooth to out side smooth surface of brick wall after racking out the joints including watering wall curing, etc. complete with cost conveyance royalties & taxes of all materials and cost of all labour with T&P required for the work etc.complete.
2116mm thick cement plaster (1:6) in all floors finished smooth to inside rough surface of 10 thick brick walls after rocking out the joints including watering and curing with cost conveyance, royalty and taxes of all materials and cost of all labour with T&P required for the work etc complete.
22R.C.C. work (1:1½:3)) in lintels, bearing of Chajja and bad blocks in all floor having minimum compressive strength (in work test) 150 kg / cm2 in 5 cm cubes at 28 days after mixing & test conducted in accordance with I.S. 456 & I.S. 516 using 12 mm to 20 mm size black hard crusher broken / granite chips (20 mm size not to exceed 25%) including hoisting lowering, laying and compacting concrete watering & curing for 28 days centering and shuttering and finishing the exposed surface smooth providing groves or beads wherever necessary including cost, conveyance, royalty & taxes of all materials & cost of all labour with T&P required for the work etc. complete in all respect but excluding cost MS Rods or Tor steel & binding wires and labour charges for bending and tying the grills.
23Cutting straightening coiled or bent up MS Rods or Tor steel bending, binding welding and joining if necessary and tying the grills and placing in position as required for RCC work and of providing fan hook hoisting, lowering & laying including cost conveyance & taxes of MS Rod or Tor steel & binding wire of 18 to 20 guage required for the work for bending, binding & tying the grills (payment will be made on weight of MS Rods or Tor steel only & no separate payment will be made towards the weight of binding wires).
24Cement concrete (1:4:8) in foundation and floors using 4 cm. size black hard hand broken granite metals of approved quality and from approved quarry including lowering, laying concrete watering & curing etc. complete to required level including cost, conveyance royalties & taxes of all materials & cost of all labour with T&P required for work complete
25Dismantling and removing cement concrete including stacking the useful materials for reuse and removing the debris within 50m lead.Per 1 cum
26Dismantling brick or stone masonry in lime or cement mortar under 3mtr height including stacking the useful materials for reuse and removing the debris within 50m lead. Per 1 cum
27R.C.C. work (1:1½:3) in Plinth Bend in all floors having a minimum compressive strength (in work test) 200 kg per cm2 in 15 cm cubic at 28 days after mixing and tests conducted accordance with I.S.456 and I.S.456 and I.S.516 using 12mm to 20mm size black hard crusher broken granite chips (20mm size not to exceed 25%) including hoisting, lowering, laying and compacting concrete watering and curing for 28 days centering, shuttering and finishing the exposed surface including finishing of the selling smooth providing grooves or beads where necessary and providing required number of fan hooks as directed by the Engineer-in-charge including cost, conveyance, royalties taxes of all materials and cost of all labour with T&P required for the work etc. complete in all respects but excluding cost of M.S.Rods or Tor steel & binding wires and labour charges for bending and tying the grills.
28Supplying fitting & fixing tiles in dado, skirting and risers of steps on 12mm thick cement plaster (1:3) joined with neat cement slurry mixed with pigments to match the shade of the tiles including rubbing and polishing compete including cost of pre-cast tiles.
29P.C.C. work of M-20 grade with 20mm and down grade black hard granite (crusher broken) stone chips including hoisting and laying as per the direction of EIC
30Carriage of excavated earth by mechanical means within 5 K.M. lead with loading including transportations with initial lead with spreading & leveling the earth etc. complete as per the direction of the Engineer-in-charge.
31E.I. Portion of work : Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type (anti bactorial & flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) (anti bactorial & flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.
32GROUP-A
33GROUP-B
34GROUP-C
35Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( (anti bactorial & flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
36Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( (anti bactorial & flame retradant type)) with suitable size modular box & cover(anti bactorial & falme retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
37Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)((anti bactorial & flame retradant type)) with suitable size modular box & cover(anti bactorial & flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN)/Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
38Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5)
39Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5)
40Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5)
41Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit. (4X6+2X4)
42Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 6 sq. mm copper wire for earth continuty conductorin 32 mm dia non metallic heavy duty conduit . (4X10+2X6)
43S/F of Bakelite angle holder/batten holder (make-Anchor/Havells or equievalant reputed make A catagory ISI marked as approved )of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
44S/F of 9 watt LED bulb of an approved ISI Make (Crompton/Havells/Bajaj)
45S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge (Make: legrand (Myrius) /Schneider(Zencelo)/Panasonic(Vision)
46Sub-Head II (Light fitting Fixture & Fan)
47Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour BLDC copper winding ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix/Bajaj Turbo Pro 12DC5 ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.(With fan Regulator)
48Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years
49SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years .
50S/F of 400mm Wall fan with all accessories and connections (Make-Usha-Maxx Air Ultra/Polycab-Arey HS/Cropmton-WM Hiflowave/ Havells-Accelero HS/ Anchor-Altrix HS-OWH/ Orient-Wall43
51BDBS,DB,AC DB,FLOOR PANELS,MCBS
52Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ABB ITUS as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years.
53S/F of 4 way (4+12) TPN MCB DB double door with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 2 years
54S/F of MCB 4 way Double Door SPN MCB DB of an approved ISI Make
55Supplying and fixing 6-32 Amps rating, C series,10KA breaking capacity,SP, 240 volts, MCB . Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .. The MCB should be Replacement Warranty will be 1 years..
56Supplying and fixing 32 Amps rating,C series,10KA breaking capacity, 2P, 415 volts, MCB 30mA . Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .
57Supplying and fixing 63 amps rating, 415 volts, C series,10KA breaking capacity, FOUR poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 years.
58AC Machine & Stabilizer
59S/F of Copper 5 Star Rated 1.5 Ton Split type AC.Machine(LG-AS-Q20JWZE/ O-General-ASGG18CGWA-B/ Daikin-FTKU50XV16) make of LG/Daikin/O-General of ISI make.
60Installation charges of 1.5 ton AC.machine.(As per Finalised Location)
61S/F of 5KVA Voltage stabiliser having digital display ,intial time delay system i.e certified with ISO 9001:2008 with working range of (90-300)V of make V.guard/Autotake/Luminous.
62(Earthing) INSTALLATION
63Earthing with G.I earth pipe 3 meter long 40 mm dia ISI marked including accessories and providing masonary enclosure with cover plate having locking arrangment and watering pipe etc with charcoal and salt as required ( 4 no of earthing required For DG Set)
64Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge.
65S/F of 100 Amp 4 pole TPN MCCB in sheet steel enclosure (Havells/L&T)
66S/F of 100 Amp 6 way TPN copper bus-bar (Havells/L&T)
67Solar Light
68Supply of Elegant look 60 W (+/-10%) AIO LED Solar Street lights having extruded alluminium housing, 180Wp or more Mono Crystalline Panel/Laminates fixed on the top of the luminaire housing, maintenance free 12.8 volts 78 Ah or more LiFePO4 battery(BIS certified) , BMS, MPPT charge controller, PIR sensor to provide 2 days (24 hrs ) back up . The luminaire is having IP 65 protection for critical components, IK 07 and having lumen output of > 10000 lumen and having minimum lumen efficacy >160 lm/w) as per LM 79 report third party NABL lab to justify the lumen output & lumen efficacy . Lenses should be provided on the LED chip for better lighting dstribution to avoid glare on human eyes. Both the luminaire and Mono Crystalline Panel must be manufactured in India. The Solar lighting company must submit the third party NABL lab reports to justify the luen efficacy,luminaire output , IK 07 and IP 65 protection ( In house NABL lab reports will not be acceptable).The Solar Street light and solar panel having capacity of 180 Wp or more must be designed to take the wind load at 180 KM/HR wind speed (As per wind load test report ) .The Solar lighting companies should submit the lighting design report prepared by their in house lighting design for achieveing desired lux level if required as per the direction of engineer in charge . The Scope of work includes 5 years comprehensive maintainace work including repair /Maintainance/Replacement of the product in case of any defect including labour/The following test reports must be submitted for the technical acceptance of the products.1.LM 79 REPORT (Third party NABL lab only) , 2. IK 07 (Report of Third party NABL lab only for any wattage of AIO solar light ) , 3. IP 65 (Report of Third party NABL lab only , 4. Wind load test report of AIO Street light having 180 Wp or more capacity Solar Mono Panel suitable for 180 KM/Hr wind Speed.The AIO solar street light must complies to the following :1. EN50530 – MPPT Efficiency , 2.. IEC61547 , 3. IEC61000-3-2 – EMC , 4. IEC 60598-2-3 ,5. IEC 62109-1, ( The necessary test reports of third party NABL lab against the above must be submitted for any wattage of AIO Solar street lights for acceptance of product/TDS approval prior to start of the work. All the test reports must be in the name of solar lighting company )Make- (Philips/Panasonic/Wipro/Bajaj/Crompton )
69Supply of 8 mtr long hot dip galvanized Octagonal pole having base dia of 155 mm and top dia of 70 mm and plate thick ness of 4 mm or more. complete with base plate and 4 nos. Jtype En 8 grade foundation bolts to withstand 180 KM / HR or more wind speed considering the weight & dimension of 1 nos 60 W AIO Solar light to be fitted in the pole at two diffrent heights ( One light on Pole Top and second light on the differential bracket)(Make - Bajaj/Vakrangee/Valmont /RR Ispat/ Utkarsh)
70Construction of RCC foundation by using M20gradeRCC and Fe415 grade reinforcementin the foundation by considering the SBC as 10 T per sq mtr and fixing 4 nos. EN8 grade foundation bolts in that foundation for installation of pole with solar lighton that foundation.The work shall be executed as per the instruction of EIC .
71Installation of 8 mtr pole on the adaptor plate after fixing the 60 W AIO Light in the pole by using suitable machinery by taking all safety precautions as per the direction of EIC. (make- as approved by PWD Odisha)
72Battery & UPS :-
73S/F of 2300 VA UPS( Microtake/Luminous/EXIDE) with 2nos 160 AH Sine Wave inverter battery & trolley set. (make:- Exide/Amaron/Luminous(Inverlast)/V Guard
74S/F of 6/16 amp top of approved ISI Make Please Enable Macros to View BoQ information

Other Detail

Information Source http://tendersodisha.gov.in/nicgep/app
Download FileName File Description File Size
Download BOQ_592363.xls Tender Documents 0 KB
Download d8766dbc-4316-44ad-b2e7-2e1c3371fd0b.html Tender Documents 0 KB
Download DTCN3.pdf Tender Documents 0 KB
Download Tendernotice_1.pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.