| 1 | Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc casing and capping complete with wooden switch board with bakelite cover and piano type switch including connection etc as required:- |
| 2 | Short Point :- |
| 3 | Medium Point :- |
| 4 | Long Point :- |
| 5 | Providing and fixing of 3 pin 5/6 amps plug point with piano type 5/6 amps switch and socket including connection with 2x1.5 sq. mm PVC insulated Copper conductor cable (FR) on switch board, earthing the 3rd pin etc. as required:- |
| 6 | Wiring for circuit /Sub-main with following sizes PVC insulated copper conductor cable (FR) in PVC casing and capping etc. as required. |
| 7 | 2 x 1.5 sq.mm:- |
| 8 | 2 x 2.5 sq.mm:- |
| 9 | 2 x 4 sq.mm:- |
| 10 | 2 x 6 sq.mm:- |
| 11 | 4 x 6 sq.mm:- |
| 12 | 4 x 10 sq.mm:- |
| 13 | Wiring for Circuit/Sub-main with the following sizes of PVC insulated Copper conductor cable (FR) in existing PVC casing capping/ conduit in recess/ surface including connection etc. as required. |
| 14 | 1 x 1.5 sq.mm:- |
| 15 | 1 x 2.5 sq.mm:- |
| 16 | 2 x 1.5 sq.mm:- |
| 17 | 2 x 2.5 sq.mm:- |
| 18 | 4 x 6 sq.mm:- |
| 19 | 4 x 10 sq.mm:- |
| 20 | Earthing with 40 mm dia G.I. Earth pipe (medium gauge) 4.5 m. long complete with masonry enclosure on top CI cover plate size 12\\"x 12\\" having locking arrangement including CC work, holes on earth pipe etc. as required:- |
| 21 | Extra for using salt (5 kg) and charcoal (46kg) for pipe earth electrode as required. |
| 22 | Proving and fixing / Drawing 4.06 mm dia (8 SWG) Copper wire on surface or in existing G.I / PVC / Polythene pipe for loop earthing as required. |
| 23 | Providing and laying of 15 mm dia(medium guage) G.I Pipe for drawing of 4.06 mm (8SWG) dia copper wire for earth connection from earth electrodes etc as required |
| 24 | Providing andfixing of following sizes PVC Conduit (medium guage) on surface with all accessories etc. as required. |
| 25 | 19/20 mm dia |
| 26 | Supplying & fixing of 1200 mm sweep white color AC ceiling fan capacitor type double ball bearing complete with 300 mm down rod,canopies,shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated Copper conductor cable(FR) (ISI marked, BEE 1 star/minimum service value 4.0 m3/min/W). |
| 27 | Supplying and fixing of the following electrical accessories including necessary connection etc. as required. |
| 28 | Electronic 5 step fan regulator:- |
| 29 | Supplying & fixing of 40 mm dia G.I pipe (medium gauge) cross bar for fixing of ceiling fan/luminaries including painting & necessary accessories etc as required. |
| 30 | Supplying & fixing of 40mmX6mm MS clamp for installation of ceiling fan/luminaries on cross bar including necessary accessories etc. as required. |
| 31 | Supplying and fixing of following surface/recess mounted LED luminaries in powder coated die cast housing complete with high efficiency polycarbonate diffuser and necessary connection etc. as required (with 50000 burning hours and minimum lumen output of 100 lm/watt):- |
| 32 | Surface mounted integrated 20 watt LED batten with polycarbonate diffuser:- |
| 33 | Excavation of earth for cable trench of 800mm depth & 300mm width in all kinds of soil including back filling of cable trench with the excavated soil with 20cm layer of sand, 3.5 nos bricks per metre for protection including ramming, consolidating to the original shape as per direction of Site Engineer : |
| 34 | Supplying and laying of the following sizes XLPE insulated PVC sheathed aluminium conductor armoured cable with necessary connection etc as required:- |
| 35 | 3 core 6 sq mm:- |
| 36 | Drawing of armoured/un-armoured cable with proper saddling etc as required:- |
| 37 | Supplying and fixing of powder coated sheet steel enclosure on surface/recess, suitable for 240/415 volts MCB/ Isolator/ RCCB (SP/ SPN/ DP/ TP/ TPN/FP) complete with necessary bus bar, neutral link,din rail ,earth bar, etc. i/c connection as required . |
| 38 | (2+6)/8 way MCB DB (single door):- |
| 39 | (2+4)/6 way MCB DB (single door):- |
| 40 | Supplying & installation of isolators of following ratings in the existing MCB DB including connection etc as required: |
| 41 | 40 amps DP isolator:- |
| 42 | Supplying & installation of 10 KA breaking capacity, B/C curve MCB of following ratings in the existing MCB DB including connection as required: |
| 43 | 6 to 32 amps SP MCB:- |
| 44 | Supplying and fixing of the following ratings switch disconnector fuse unit(main switch) made of sheet steel enclosure with all accessories including drilling holes on the board/MS clamp and necessary connection etc. as required |
| 45 | 63 amps 415 volts TPN main switch (rewireable):- |
| 46 | 32 amps 240 volts DP main switch (rewireable):- |
| 47 | Supplying and installation of Bus bar chamber of the following ratings and sizes made of steel sheet enclosure with all accessories including necessary connection etc. as required:- |
| 48 | 63 amps 415 volts four strip Copper busbar chamber 4 ways of size (455mmx330mmx120mm):- |
| 49 | Supplying and fixing of following copper terminal ends. |
| 50 | 4 sqmm |
| 51 | 6 sqmm |
| 52 | 10 sqmm |
| 53 | Supplying and fixing of MS frame made of (25mm x 25mm x 5mm) MS angle with necessary support by (40mm x 6mm) MS flat and 12 mm thick marine plywood on top, grouted on wall with 4 nos legs (25mmx25mmx5mm MS angle 20 cm long) finished with red oxide and 2 coat synthetic enamel paint including necessary cc work, mending the damages & painting etc as required:- Please Enable Macros to View BoQ information |