| 1 | Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc casing and capping complete with 6/10 amps modular type switch, cover plate, surface modular switch board including connection etc as required:- |
| 2 | Short Point :- |
| 3 | Medium Point :- |
| 4 | Long Point :- |
| 5 | Providing and fixing of 3 pin 5/6 amps plug point with piano type 5/6 amps switch and socket including connection with 2x1.5 sq. mm PVC insulated Copper conductor cable (FR) on switch board, earthing the 3rd pin etc. as required:- |
| 6 | Providing and fixing of 3/6 pin 16/20 amps plug point with modular type 16/20 amps switch and socket including connection with 2x2.5 sq. mm PVC insulated Copper conductor cable(FR) on surface modular switch board, earthing the 3rd pin etc. as required:- |
| 7 | Wiring for circuit /Sub-main with following sizes PVC insulated copper conductor cable (FR) in PVC casing and capping etc. as required. |
| 8 | 2 x 1.5 sq.mm:- |
| 9 | 2 x 2.5 sq.mm:- |
| 10 | 2 x 4 sq.mm:- |
| 11 | 4 x 6 sq.mm:- |
| 12 | 4 x 10 sq.mm:- |
| 13 | 4 x 16 sq.mm:- |
| 14 | Wiring for Circuit/Sub-main with the following sizes of PVC insulated Copper conductor cable (FR) in existing PVC casing capping/ conduit in recess/ surface including connection etc. as required. |
| 15 | 1 x 1.5 sq.mm:- |
| 16 | 1 x 2.5 sq.mm:- |
| 17 | 1 x 4 sq.mm:- |
| 18 | 1 x 6 sq.mm:- |
| 19 | 2 x 1.5 sq.mm:- |
| 20 | 2 x 2.5 sq.mm:- |
| 21 | 2 x 4 sq.mm:- |
| 22 | 4 x 6 sq.mm:- |
| 23 | 4 x 10 sq.mm:- |
| 24 | 4 x 16 sq.mm:- |
| 25 | Earthing with 40 mm dia G.I. Earth pipe (medium gauge) 4.5 m. long complete with masonry enclosure on top CI cover plate size 12\\"x 12\\" having locking arrangement including CC work, holes on earth pipe etc. as required:- |
| 26 | Extra for using salt (5 kg) and charcoal (46kg) for pipe earth electrode as required. |
| 27 | Proving and fixing / Drawing 4.06 mm dia (8 SWG) Copper wire on surface or in existing G.I / PVC / Polythene pipe for loop earthing as required. |
| 28 | Supplying and fixing of the following modular accessories including necessary connection etc. as required. |
| 29 | 5 step fan regulator (2M):- |
| 30 | Blank plate (1M):- |
| 31 | Supplying and installation of powder coated steel sheet enclosure (MCB DB) suitable for 240/ 415 volts MCB/ Isolator/ RCCB (SP/ SPN/ DP/TP /TPN /FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connection as required. |
| 32 | 2 way SPN MCB DB (Single door):- |
| 33 | 6 way horizontal TPN MCB DB (Double door):- |
| 34 | Supplying, installation, testing & commissioning of powder coated prewired panel board suitable for 415 volts TP MCCB as incomer & outgoing including busbar & connection as required of the following ratings & sizes:- |
| 35 | 6 way TP MCCB outgoing & TP MCCB incomer upto 400 amps:- |
| 36 | Supplying, installation, testing & commissioning of powder coated prewired digital meter module complete with ammeter, voltmeter, phase indicator lamp, control fuses, CTs, in the existing panel board including connection etc. as required:- |
| 37 | Supplying and fixing of following ratings MCB B/C curve having breaking capacity 10 KA in the existing MCB, DB including connection as reqd. |
| 38 | 6 to 32 amps SP MCB:- |
| 39 | 6 to 32 amps DP MCB:- |
| 40 | 40/50/63 amps TPN MCB:- |
| 41 | Supplying & installation of TP/FP MCCB of following ratings in the existing MCCB enclosure/ panel board including connection etc as required (Ics=100% of Icu with adjustable settings):- |
| 42 | 16 to 100 amps FP MCCB, Breaking capacity 16/18KA (Thermal Magnetic):- |
| 43 | 16 to 100 amps TP MCCB, Breaking capacity 16/18KA (Thermal Magnetic):- |
| 44 | Supplying and fixing of the following ratings switch disconnector fuse unit(main switch) made of sheet steel enclosure with all accessories including drilling holes on the board/MS clamp and necessary connection etc. as required |
| 45 | 32 amps 415 volts TPN main switch (rewireable):- |
| 46 | Supplying and installation of Bus bar chamber of the following ratings and sizes made of steel sheet enclosure with all accessories including necessary connection etc. as required:- |
| 47 | 32 amps 415 volts four strip Copper busbar chamber 4 ways of size (300mmx240mmx80mm):- |
| 48 | Supplying and fixing of following surface/recess mounted LED luminaries in powder coated die cast housing complete with high efficiency polycarbonate diffuser and necessary connection etc. as required (with 50000 burning hours and minimum lumen output of 100 lm/watt):- |
| 49 | Surface mounted box type batten suitable for single 18/20 watt integrated LED tube lamp (without lamp):- |
| 50 | Surface mounted round/Square shaped 12 watt LED downlight with integral driver and high quality polycarbonate diffuser:- |
| 51 | Supplying and fixing of following LED Tubes, retrofit bulbs/lamps for LED luminaries including necessary connection etc. as required:- |
| 52 | 18/20 watt LED tube with integral driver and polycarbonate diffuser (50000 burning hours and minimum lumen output of 100lm/watt):- |
| 53 | 9 watt LED retrofit lamp with polycarbonate body and aluminium heatsink :- |
| 54 | Supplying and fixing of following outdoor LED luminaries in powder coated die cast housing complete with heat resistant tempered glass/diffuser including necessary connection etc. as required (50000 burning hours and minimum lumen output of 100 lm/watt):- |
| 55 | 60 watt LED street light fixture with integral driver and secondary lens (IP 66):- |
| 56 | 6 watt/10 watt LED Bulkhead light with high quality polycarbonate diffuser (IP 65):- |
| 57 | Supplying & installation of 300 mm sweep metalic body exhaust fan including connection etc as required:- |
| 58 | Supplying & installation of shutter for 225/230/300 mm sweep metalic body exhaust fan in the existing hole as required:- |
| 59 | Making different sizes of hole in the wall for fixing of exhaust fan including finishing the same with cement plastering and painting etc as required: |
| 60 | Supplying & fixing of 1200 mm sweep white color AC ceiling fan capacitor type double ball bearing complete with 300 mm down rod,canopies,shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated Copper conductor cable(FR) (ISI marked, BEE 1 star/minimum service value 4.0 m3/min/W). |
| 61 | Supplying and fixing of MS frame made of (25mm x 25mm x 5mm) MS angle with necessary support by (40mm x 6mm) MS flat and 12 mm thick marine plywood on top, grouted on wall with 4 nos legs (25mmx25mmx5mm MS angle 20 cm long) finished with red oxide and 2 coat synthetic enamel paint including necessary cc work, mending the damages & painting etc as required:- |
| 62 | Supplying, installation, testing & commissioning of powder coated side cable module (1 pair) in the existing panel board including connection etc. as required suitable for the following sizes and ratings:- |
| 63 | 4/6 way outgoing and incomer upto 400 amps :- |
| 64 | Supplying and laying of the following sizes XLPE insulated PVC sheathed aluminium conductor armoured cable with necessary connection etc as required:- |
| 65 | 3 core 4 sq mm:- |
| 66 | Drawing of armoured/un-armoured cable with proper saddling etc as required:- |
| 67 | Supplying & fixing of G.I. pipe (medium gauge) bracket fabricated at suitable angle for fixing of outdoor light on wall/ RCC base with necessary MS clamp, nut, bolt etc as required:- |
| 68 | 40 mm dia:- |
| 69 | Supplying and installation of fuse unit kitkat/HRC/HBC of the following ratings in existing main switch/panel board including necessary connection etc as required:- |
| 70 | 100 amps kitkat porcelain fuse unit with base(rewireable):- |
| 71 | Supplying and fixing of M.S Box size (12\\"x8\\"x6\\") made of 3 mm size MS sheet with an arrangement of fittingMCB SP and Neutral link i/c rubber Gasket to the cover, water outlet duct to the below and locking arrangement. Please Enable Macros to View BoQ information |