| 1 | Supply and Fixing on load change over switch SS enclosure complete with capacity 200 Amp, 415 Volt, 4 pole, 50 Hz. | Complete all as specified and directed |
| 2 | Supply and Fixing sheet metal enclosure SPN DB double door having facility to fix MCB SPN as incomer and MCBs as outgoing, SPN 4 ways, IP-43 | with metal door complete fitted with bus bars, neutral link, blinking plates including making good surfaces complete all as specified and directed Note MCB SPN and MCB SP will be measured and paid seperately. |
| 3 | Supply and Fixing sheet metal enclosure TPN DB double door having facility to fix MCB TPN as incommer and MCBs as outgoing TPN 4 ways, IP-43 | with metal door type complete all as specified and directed. Note MCB TPN and MCB SP will be measured and paid seperately. |
| 4 | Supply and fixing bus bar chamber 100 amp, 4 way, 415 volts enclosurre is made from CRCA sheet of thickness 3.15mm CRCA sheet cover | copper strip busber, embosed earthing terminals on both sides, removale top and bottom gland plates with conduit knockout with sufficient spaces for different cable sizes complete all as specified and directed |
| 5 | Supply and Fixing of straight Through epoxy cable joint kit incl jointing materials making joints of UG electric cable 1100 V grade Nominal cross sectional area not exc.50 sqmm, 3.5 by 4 core | heavy duty with PVC by XLPE insulated aluminium stranded conductor, and testing complete all as specified and directed. |
| 6 | Supply and Fixing Straight through epoxy cable joint kit incl jointing materials making joints of UG electric cable 1100 V grade cross sectional area 240 sqmm to 300 sqmm, 3.5 core. | heavy duty with PVC by XLPE insulated aluminium stranded conductor, and testing complete all as specified and directed |
| 7 | Supply and Fixing End termination epoxy cable joint kit including jointing materials for making joints of UG electric cable 1100 V grade nominal cross sectional area 240 sqmm to 300 sqmm, 3.5 core | heavy duty, with PVC by XLPE insulated aluminium stranded conductor and testing complete all as specified and directed. |
| 8 | Supply and Fixing of Galvanised iron pipe 100 mm bore dia light grade for protection of UG cable | laid in floors by road crossing fixing to pole with Mild Steel Clamps clamps, nuts, bolts etc., complete all as specified and directed |
| 9 | Supply of digging nad layingg in excavation trenches not exc. 1.50 m wide and not exc. 1.50 m in depth, complete all as specified and directed. | taking out and Laying of Cables etc and getting out in soft by loose soil |
| 10 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exc. 250 mm in soft loose soil | complete all as specified and directed. |
| 11 | Supply and Fixing of Galvanised iron pipe 40 mm bore dia light grade for protection of UG cable | laid in floors by road crossing fixing to pole with mild steel clamps, nuts, bolts etc. complete all as specified and directed |
| 12 | Supply, installation, commissioning and testing including providing all necessary electrical connection,LT feeder panel board of size 1.0 m X 0.6 m X 0.5 m | CPRI Approved,outdoor typedouble door, factory made out of 3 mm thick MS sheet,deep having hinged opening arrangement in front and back side and bottom frame made out of angle iron size 50x50x6mm thick and complete all specified and directed |
| 13 | Supply, installation, commissioning and testing including providing all necessary electrical connections LT feeder panel board of size 0.6 m X 0.6 m X 0.5 m | CPRI approved,outdoor type, double door factory made out of 3 mm thick MS sheet, deep having hinge opening arrangement in front and back side and bottom frame made out of angle iron of size 50x50x6mm thick and complete all as specified and directed |
| 14 | Supply and Fixing earhing complete with GI earth plate electrode of size 600x600x6mm thick.Complete all as specified and directed in BoQ spec file | buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of the plate not less than 1.5 meter below normal ground level connected to GI earth strip of size 32x6mm earth and complete all as specified and directed |
| 15 | Supply and Fixing earhing complete with GI earth plate electrode of size 600X600X6mm thick. Complete all as specified and directed in BoQ spec file | buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of the plate not less than 1.5 meter below normal ground level connected to GI earth lead wire by means of nuts, bolts, check nuts, wasjhers of galvanised iron as steel, protected by GI pipe minium grade 40mm bore and complete all as speciifed and directed |
| 16 | Supply and Fixing of Sub-Class B brick, well burnt, laid breadth-wise along the axis of cable laid in trenches over sand cushion laid for UG cable protection, complete all as specified and directed. | Supply and Fixing of Sub-Class B brick, well burnt, laid breadth-wise along the axis of cable laid in trenches over sand cushion laid for UG cable protection, complete all as specified and directed. |
| 17 | Supply and Fixing horizontal boring under a depth of 0.65 m from the GL for passing pipe upto 40 mm bore dia | under road by footpath complete all as specified and directed |
| 18 | Supply of Digging and Laying of Removing excavated materials soils not exc. 50 m and depositing where directed at a level not exc.1.50 m | above the starting point in soil complete all as specified and directed. |
| 19 | Taking down out unserviceable or serviceable LT UG cables of nominal cross-sectional area 300 sqmm including bricks, GI pipes etc. | of any descriptions, laid in Trenches and by or fixing with Walls BY poles including Segregating of Serviceable Meterials viz Bricks, cables, GI Pipes etc and keep in safe custody for reuse complete all as specified and directed. |
| 20 | Taking down out unserviceable or serviceable LT UG cables of nominal cross-sectional area 50 sqmm 3.5 core including bricks, GI pipes etc. | of any descriptions, laid in Trenches and BY or fixing with Walls by poles including Segregating of Serviceable Meterials viz Bricks, cables, GI Pipes etc and keep in safe custody for reuse complete all as specified and directed. |
| 21 | Supply of Digging and Laying of Sand cushioning dry in trenches for protection of UG cables below, above and around the UG cable laid in trenches of 230 mm spread thickness | and consolidated thickness 180 mm, complete all as specified and directed. NOTE- For the purpose of payment Punned thickness of Stand Cashioning only shall be Measured and Paid for |
| 22 | cutting road by hard standing and making good disturbed surfaces by using PCC type-C2,1-3-6 by using 40 mm graded stone aggregate | for the fixing the pipe complete all as directed by Engineer-in-charge. |
| 23 | Boring of holes under road,pavement,hard standing by trenchless technology using ultra sounding technique including HDPE pipe 150 mm dia suitable for 0.4 MPa working pressure | Boring of holes under road,pavement,hard standing by trenchless technology using ultra sounding technique including HDPE pipe 150 mm dia suitable for 0.4 MPa working pressure. Complete all as specified and directed |
| 24 | cutting chases, chipping in making good to facings, where required and pointing in cement mortar 1-3 to ends or edges of landings, steps, sills, sunshades, shelves, lintels etc. | cutting for concealed wiring etc and making oood cutting not exc 10cm grith in brick walls complete all as directed by Engr-in-charge. |
| 25 | submain wiring comprising single core 2 runs of 6 Sqmm nominal coss sectional area FRLH multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade | drawing in and including appropriate dia in PVC conduit and its fittings complete surface by concealed incuding provision of 1x6 Sqmm nominal cross secional area multistranded copper conductor cable PVC insulated unsheathed 1100 volts grade as earth wire complete all as specified and directed |