Tender Brief Tender For maintenance of electrical installation & Fans, repair maintenance Pump Set, Street / Compound Light At Udyog Sadan, Qutub Institutional Area, New Delhi During The Year 2026-27 (Sh- Supply Installation Testing and Commissioning of Fire Figh
City Delhi
State Delhi
Document Fees Refer document
EMD INR 35752.0 /-
Tender Value INR 17.87 Lakhs /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for maintenance of electrical installation & Fans, repair maintenance Pump Set, Street / Compound Light At Udyog Sadan, Qutub Institutional Area, New Delhi During The Year 2026-27 (Sh- Supply Installation Testing and Commissioning of Fire Fighting & Fire Alarm System At Udyog Sadan Building).Maintenance Of Street Lights, High Masts On Delhi Pwd Roads Under Pwd M-South Division During 2026-27 (Sh : Replacement Of Accidental Poles, Led Fitting, Earthing And Cabling Work At Various Roads Under M-South Division)

Key Dates

Publish Date 21-05-2026
Last Date of Bid Submission 28-05-2026
Tender Opening Date 28-05-2026

Contact Information

Company Name Public Works Department
Contact Person Executive Engineer (E)
Address O/o The Executive Engineer (E) South Elect. Div., PWD, Sukhdev Vihar, Mathura Road, Near Okhla Flyover, New Delhi

BOQ Items

Name of Work:- MOEI & Fans, RMO Pump Set, Street / Compound light at Udyog Sadan, Qutub Institutional Area, New Delhi during the year 2026-27 (SH- SITC of Fire Fighting & Fire Alarm System at Udyog Sadan Building).Maintenance of Street Lights, High Masts on Delhi PWD Roads under PWD M-South Division during 2026-27 (SH : Replacement of Accidental Poles, LED Fitting, Earthing and Cabling Work at Various Roads under M-South Division)
Sl. No. Item Description
1Replacement of old rusted/accidental of street light poles with new flange mounted hot dip Galvanized Octagonal Poles of 10 mtrs. height made from 4 mm thick HT Steel plate, having bottom dia of 200 mm. & top dia of 100 mm. complete with window with flash cover at a height of 0.5 mtrs from the base for cable termination block etc. and galvanized base plate of size 320mm x 320mm x 20mm thick on existing cement concrete pedestal as required i/c supplying and fixing of the following in the window box provided for cable termination:- a) 6 mm thick laminated sheet mounted inside the window i/c providing and welding 3 Nos. GI flat strip 4 mm thick of suitable length and having suitable size tapped holes - 2 Nos on each strips.b) 63 amps. terminal block suitable for 25 sq. mm conductor- 4 Nos. & shorting links as required. on DIN channel i/c pdg. and fixing DIN channel of suitable length - 1 No. on the existing laminated sheet. c) 6 amp. SP MCB 'C' characteristics Curve - 1 Nos, earth stud - 1 Nos, welded at suitable height two nos washers, springs washers & nuts. d) Cable support clamp sutiable for 4 Nos. of 4 x 25 sqmm cable. i/c less Credit of old dismental material
2Providing and laying in position 1:1½:3 reinforced cement concrete foundation made out of ready mix M-20 grade concrete of size 600mm (L) X 600mm (B) wide and 1500mm deep i/c excavation of earth/WBM Road/CC Road, providing , cutting, bending and placing in position, reinforcement of cold twisted bars of 12mm dia - 1600mm long (approx)-8 Nos. and reinforcement ring of cold twisted bar of 8mm dia - 2800mm (approx) - 10 nos. (with 150mm spacing) as required with positioning of foundation bolts and providing 90 mm. (O.D.) DWC, HDPE pipe for cable entry & exit etc complete as reqd. (Only RMC shall be used at site in presence of Engineer-In-Charge or his authorized representative)
3Supplying and fixing 4 Nos. M-24mm dia X 750mm long Gl foundation bolt (EN8 grade) with nuts. washer including 2 Nos. template of 3 mm thick size 320 x 320 mm with 4 nos. 28 mm dia holes, to match with PCD of Pole base plate as reqd
4Fabrication, supplying & fixing of Single/Double/Triple/Quadruple armed galvanized iron bracket of 1.0 mtr long arm of suitable dia on top/in between on suitable height in the existing pole as directed by Engineer-in-charge with the help of drilling, cutting, tightening bolts etc complete as reqd.(Sample must be approved by Engineer-in-Charge before installation at site)
5Supplying and fixing of Following sizes PVC Round Sheathed Multi Core Industrial Flexible unarmoured Aluminium conductor Cable in the surface of wall/ceiling/ in street light poles etc with the help of suitable size clamps etc complete as reqd.
6a) 3 core 2.5 sq. mm
7Supplying, installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >80 , under voltage and over voltage protection,EMIEMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , CCT 3000°K /4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).
8150 watt
9Supplying & laying of one number 4 x 25 sq.mm XLPE insulated and PVC sheathed Aluminium conductor armoured power cable of 1.1 KV grade in the follwing manner etc as complete reqd.a. In the existing RCC/ HUME/ METAL pipe
10Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
1163 mm dia (OD-63 mm & ID-51 mm nominal)
12Fabrication, Installation, Testing and Commissioning of floor mounting double door minimum 300 mm depth with locking arrangement front and rear openable, totally enclosed, compartmentalized, dust, vermin proof and outdoor type Feeder Pillar (IP54) fabricated out of 2mm thick cold rolled carbon annealed sheet steel, (minimum) surface area 1.50 Sq.Mtr, with 300 Amp 4 strip AL. bus bar, cable alley on both sides, powder coated paint of approved shade after 7 tank cleaning process and 1 no 20x3mm GI strips throughout the width of feeder pillar consisting two earth studs on each strip complete with provision for incoming and outgoing switchgears including making connections/ inter connections with lugs/ thimble for switchgears and control wiring with 2.5 sq.mm PVC insulated FRLS copper conductor cable, including providing 50mm X 50mm X 6 mm thick (NS) 90 cm long legs out of which 45 cm duly grouted in existing cement concrete 1:2:4 etc complete as reqd.
13(Drawing shall be got approved from Engineer-incharge before fabrication)
14Incomer:-
15200A TP 25KA MCCB WITH SPREADER LINK (Ics=100%Icu) : 01 No.
16Metering:-
17DIGITAL AMMETER (0-200) WITH SELECTOR SWITCH: 01 No.
18DIGITAL VOLT METER (0-500) WITH SELECTOR SWITCH : 01 No.
19INDICATION LED LAMP RYB : 03 No.
202A SP MCB : 03 No.
21200/5A CT CLASS-1: 03 No.
22Out going :-
23100A TP 16KA MCCB WITH SPREADER LINK (Ics=100%Icu) : 03 Nos
24110A TP POWER CONTACTOR 220V: 01 No.
25DIGITAL TIMERS: 01 No.
26Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required: 01 Set
27Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required.
28Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required
29Providing and laying in position 1:2:4 cement concrete feeder pillar/panel foundation of required size i/c excavation & refiling of earth, providing and placing in position legs of feeder pillar grouted in CC etc complete as reqd.
30Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/submain wiring/ cable as required. Please Enable Macros to View BoQ information

Other Detail

Information Source https://govtprocurement.delhi.gov.in
Download FileName File Description File Size
Download BOQ_387231.xls Tender Documents 0 KB
Download c3b8a90a-dc81-4667-8940-94a5c3605043.html Tender Documents 0 KB
Download NIT.pdf Tender Documents 0 KB
Download Tendernotice_1 (10).pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.