Indian Tenders

Tender Notice

TDR 55588921
Tendering Authority Public Works Department
Tender No PWD/BLDG/EST/19017/2025
Tender ID 2026_PWD_843802_3
Tender Brief Tender For Deposit-Government Ayurvedic Dispensary Adichanalloor-Supply And Installation Of Inverter-General Electrical Work
City Kollam
State Kerala
Document Fees INR 555 /-
EMD INR 1893.0 /-
Tender Value INR 75728.0 /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Deposit-Government Ayurvedic Dispensary Adichanalloor-Supply And Installation Of Inverter-General Electrical Work

Key Dates

Publish Date 20-05-2026
Last Date of Bid Submission 28-05-2026
Tender Opening Date 30-05-2026

Contact Information

Company Name Public Works Department
Contact Person Assistant Executive Engineer
Address O/o Assistant Executive Engineer PWD ELECTRICAL SUB DIVISION KOLLAM

BOQ Items

Name of Work:- DEPOSIT-Government Ayurvedic Dispensary Adichanalloor-Supply and installation of inverter-General Electrical Work
Sl. No. Item Description
1Installation of inverter
2OD178573/2025-2026:Supply, conveyance, installation, testing and commissioning of 2 KVA Home UPS working by 24 Volt DC supply ( 2Nos 12V 150AH Tubular Battery) with battery charging unit with indications ,input voltage 150-270V AC supply , Output voltage 230V +/-3%, 50 Hz +/- 1% pure sine wave and Short circuit,over/under voltage,surge & spike protections including giving connection etc (Hykon/ Numeric/Supra/luminous) with 2Nos 12V 150AH fully charged Lead acid Tubular Battery with terminal leads for the existing 2 KVA inverter unit with Battery Stand for accommodating Inverter and Batteries (Hykon / luminous / Numeric, /Excide/) .--
31.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
41.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
51.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
6OD327819/2025-2026:Supplying and clamping 20mm corrugated PVC flexible conduit with necessary compression gland with locking ring and check nut at termination points using suitable size GI / painted MS saddles spacing not exceeding 60 cms on surface including making good the damages, colour washing etc. as required-
71.27.3:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm)
81.32:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
990.10.3.15:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator
1090.10.3.32:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3 pin plug top with indicator
1190.10.3.33:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket
122.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)12 way, Double door
132.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole
142.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
152.14.2:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps Please Enable Macros to View BoQ information

Other Detail

Information Source https://etenders.kerala.gov.in
Download FileName File Description File Size
Download 8a4d0a65-4205-4d79-b2d6-7496b67cf655.html Tender Documents 0 KB
Download AFFIDAVIT.pdf Tender Documents 0 KB
Download BOQ_1439732.xls Tender Documents 0 KB
Download E.pdf Tender Documents 0 KB
Download IP.pdf Tender Documents 0 KB
Download L.pdf Tender Documents 0 KB
Download PRILIMI.pdf Tender Documents 0 KB
Download SBD.pdf Tender Documents 0 KB
Download SP.pdf Tender Documents 0 KB
Download T.pdf Tender Documents 0 KB
Download Tendernotice_1 (10).pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.