Indian Tenders

Tender Notice

TDR 55588056
Tendering Authority Public Works Department
Tender No PWD/BLDG/TR/20218/2023_23_2_1
Tender ID 2026_PWD_851812_1
Tender Brief Tender For General-Commissionerate Office At Pattom, Thiruvananthapuram-Construction Of A Multi Storied Building For Various Commissions (Balance Work)-Composite Work
City Thiruvananthapuram
State Kerala
Document Fees INR 19518 /-
EMD INR 500000.0 /-
Tender Value INR 28.75 Crore /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for General-Commissionerate Office At Pattom, Thiruvananthapuram-Construction Of A Multi Storied Building For Various Commissions (Balance Work)-Composite Work

Key Dates

Publish Date 20-05-2026
Last Date of Bid Submission 05-06-2026
Tender Opening Date 08-06-2026

Contact Information

Company Name Public Works Department
Contact Person The SE (Buildings), South Circle, Thiruvananthapur
Address O/o The SE (Buildings), South Circle, Thiruvananthapuram

BOQ Items

Name of Work:- GENERAL-Commissionerate Office at Pattom, Thiruvananthapuram-Construction of a multi storied building for various Commissions (Balance work)-Composite Work
Sl. No. Item Description
1APPENDIX A- Building Proper(Civil work)
2OD29277/2023-2024:Providing and laying in position ready mixed M-35 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in -charge. Note:- Minimum cement content considered in this item is @350 kg/cum. All work above plinth level up to floor V level (Excess/less cement as per mix design is not payable/recoverable)
3OD29272/2023-2024:Providing and laying in position machine batched and machine mixed design mix M-35 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 350 kg/ cum. All work above plinth level upto floor V level (Excess/less cement as per mix design is not payable/recoverable)
45.38:Extra for R.C.C. /B.M.C/R.M.C. work above floor V level for each four floors or part thereof.
55.22A.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more
65.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
75.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
8OD212041/2024-2025:Centering and shuttering including strutting, etc. and removal of form for: Columns, Pillars, Piers, Abutments, Posts and Struts having 45-degree or nearest inclination/ slope. based on 5.9.6
95.9.7:Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)
105.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
115.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
125.9.16.2:Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsAbove 20 cm wide
1350.6.1.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.
1450.6.1.3:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure above floor two level up to floor V level thickness 20cm and above in: CM 1:6 ( 1 cement :6 coarse sand) etc complete
1550.6.3.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete
16OD255841/2022-2023:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level up to floor V level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete based on 50.6.3.2 and 50.6.1.6-extra labour.
176.5:Extra for brick work/ AAC block masonry/Tile brick masonry in super structure above floor V level, for each four floors or part thereof by mechanical means.
1813.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)
1913.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
2050.13.1:9 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete
2113.16.1:6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
2213.22:Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof.
2322.5:Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
2422.14.1:Grading roof for water proofing treatment with:Cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
25OD237787/2022-2023:Filling 6mm broken stone in sunken slab including all cost, carriage of materials and labour charges for sunken floor filling etc complete
26OD236446/2024-2025:Providing and laying matt finished vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600 x 600 mm.
27OD237975/2024-2025:Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600 x 600 mm.
28OD236447/2024-2025:Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600x600 mm
29OD212093/2024-2025:Providing and laying matt finished vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg) complete. Size of Tile 300 x 300 mm.
3011.55.1: Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
318.3.2:Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite work
32OD212095/2024-2025:Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over the existing steel frame with good quality adhesive, joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm. Granite of any colour and shade
33OD177866/2025-2026:Providing and fixing machine cut, mirror/ eggshell polished, Marble stone work for wall lining (veneer work) including dado, skirting, risers of steps, etc., in required design and pattern wherever require, stones of different finished surface texture, on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) laid and jointed with white cement slurry @ 3.3 kg/sqm including pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing, polishing etc. all complete as per Architectural drawings, and as directed by the Engineer-in-charge. a. 18mm thick Italian Marble stone slab, Perlato, Rosso verona, Fire Red or Dark Emperadore, etc.based on 8.1.1.1
3413.80:Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
3513.48.1:Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm
36OD346960/2025-2026:Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications excluding priming coat, preparation of surface, etc. complete.On steel work-DAR-13.52.1
379.117.1:Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1 mm), with wall thickness 2.0mm (±0.2 mm), corners of the door frame to be jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 x 19 mm and 1 mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer's specification and direction of Engineer-in-chargeExtruded section profile size 48x40 mm
389.118.2:Providing and fixing to existing door frames30 mm thick factory made Polyvinyl Chloride (PVC) door shutter made of styles and rails of a uPVC hollow section of size 60x30 mm and wall thickness 2 mm (± 0.2 mm), with inbuilt decorative moulding edging on one side. The styles and rails mitred and joint at the corners by means of M.S. galvanised/plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 25x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x30 mm and 2 mm (± 0.2 mm) wall thickness fixed to the shutter styles by means of plastic/galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge.
399.149:Providing and fixing casement handle made of zinc alloyed (white powder coated) for uPVC casement window with necessary screws etc. complete.
4010.28:Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
4112.45.3:Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum moisture resistant board
4250.10.1:Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
4312.65.1:Providing & fixing at all heights, levels and locations colour finish Aluminium alloy roofing sheets of alloy IS designation 31500, temper Hx8 conforming to IS 737 and dimensions as per IS code 2676 with characteristics of good formability and corrosion resistance. The profile sheets shall be fixed to truss members in slope or required pitch or curvature with Hex cap headed self drilling/tapping Stainless steel screws M6, 50 mm long with 3 mm EPDM seal washer etc. all inclusive of labour, scaffolding, T&P and sundries etc. complete as per directions of the Engineer-In-Charge. (Cost of truss/frame work shall be paid separately). 0.56 mm, Aluminium Color coated troughed profile with center to center pitch of 200 mm, depth of 32 mm, overall profile width1092 mm, cover width 1000mm.
4412.41.2:Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter
4512.4.1:Providing ridges or hips width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete.0.80 mm thick with zinc coating not less than 275 gm/m2
4612.5.1:Providing valleys of 90 cm wide overall in plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limper and bitumen washers complete:1.60 mm thick with zinc coating not less than 350 gm/ m2
479.48.1:Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding
489.136:Providing and fixing fire resistant door frame of section 143x57 mm having built in rebate made out of 16 SWG G.I. sheet ( zinc coating not less than 120 gm/ sqm) duly filled with vermuculite based concrete mix, suitable for mounting 60 minutes fire rated door shutters. The frame is fitted with intumuscent fire seal strip of size 10x4 mm (minimum) alround the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc. complete as per direction of Engineer -in-charge (Dash fastener to be paid for separately ).
499.137:Providing and fixing 50 mm thick glazed fire resistant door shutters of 60 minutes fire rating conforming to IS : 3614 (Part - II), tested and certified as per laboratory approved by Engineer-in-Charge, with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/m2) duly filled FR insulation material and fixing with necessary stainless steel ball bearing hinges of approved make including applying a coat of approved fire resistant primer etc. all complete as per direction of Engineer -in-charge ( panneling to be paid for separately).
50OD177867/2025-2026:Providing and fixing glazing in fire resistant door shutters, fixed panels, ventilators and partitions etc., with G.I. beading of appropriate size. made out of 20 SWG G.I. sheet (zinc coating not less than 120 gm/m2), fire resistant sealant, including applying a coat of approved fire resistant primer on G.I. beading etc., complete all as per direction of Engineer-in-charge With clear fire resistant glass panes 6 mm thick of approved brand, having minimum 60 minutes fire resisitance
519.139:Providing and fixing panic bar / latch (Double point ) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer -in-charge, all complete.
5210.5.1:Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces
539.53:Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
549.147D.3:Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately)Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Two track two panels sliding window made of (big series) frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 +/- 0.2 mm and single glazing bead / double glazing bead of appropriate dimension . (Area of window above 1.75 sqm upto 2.50 sqm).
559.147D.5:Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately)Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Three track three panels sliding window made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 +/- 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm)
569.147D.1:Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately)Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Two track two panels sliding window made of (small series) frame 52 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 +/- 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 1.75 sqm)
5721.3.1:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm)
589.74.2:Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete:200x10 mm
599.55.1:Providing and fixing ISI marked IS : 1341 M.S. pressed butt hinges bright finishedwith necessary screws etc. complete :125x65x2.12 mm
609.76:Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
619.81.2:Providing and fixing bright finished brass handles with screws etc. complete:100 mm
629.82:Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.
639.84:Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
644.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
6510.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover
6610.7:Providing and fixing ball bearing for rolling shutters.
6750.9.1.1:Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood
6850.9.2.1:Providing and fixing paneled and glazed shutters for doors, windows and clerestory windows, 35 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineerin - charge using Anjili/ Jack wood
6950.9.4.1:Providing and fixing paneling or paneling and glazing in paneled or paneled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured) paneling for paneled or paneled and glazed shutters 25 mm to 40 mm thick using good quality Anjili/ Jack wood
709.7.7.2:Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured), Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick:5.0 mm thick glass panes (weight not less than 12.50 kg/sqm).
7113.116:Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below:1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos.2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is donethis surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in1 or 2 layers without gap of time.)
72APPENDIX B - Internal Office Partitions(Civil work)
73OD52567/2025-2026:Providing and fixing 12 mm thick frameless toughened glass partition of approved brand and manufacture, including necessary SS fixing arrangement and making necessary holes etc. for fixing required door, all complete as per direction of Engineer-in-charge.
74OD52582/2025-2026:Providing and fixing Glass Door Lock With Strike Box - SS Grade 304 ( best make of approved quality ) for toughened glass doors including necessary cutting and making good etc. complete.
75OD52583/2025-2026:Providing and fixing Stainless Steel H Shape Door Handle of size 25 X 300 X 375 long withS.S. screws etc. complete as per direction of Engineer -in-Charge.Chrome FinishColor: Silver
7612.52.1:Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending
77APPENDIX C- External Structural Glazing and Architectural Features(Civil work)
7825.8:Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured.
79OD177868/2025-2026:Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Alumini um sheets (each0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places.Based on DAR-25.7
8021.3.2:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness (weight not less than 12.50 kg/sqm)
8125.1:Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).The weight of aluminum extruded section shall be taken for purpose of payment
82APPENDIX D - Water Supply and Drainage works(Civil work)
8318.9.3:Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work25 mm nominal dia pipes
8418.9.4:Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work32 mm nominal dia pipes
8518.9.5:Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work40 mm nominal dia pipes
8618.8.2:Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.20 mm nominal dia pipes
8718.8.3:Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.25 mm nominal dia pipes
8850.18.8.6.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 6 kgf/cm2
8950.18.8.9.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2
9050.18.9.16.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 6Kgf/cm2 - External work - Exposed on wall
9150.18.9.18.1:Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 - External work- Exposed on wall
9250.18.9.19.1:Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall
9350.18.9.3.2:Providing and fixing PVC pipes includes jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 25 mm dia 10KGF/cm2
9450.18.9.9.1:Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2
9550.18.9.10.1:Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2
9650.18.9.22.1:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia Elbow
9750.18.9.22.2:Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia 45 degree Elbow
9850.18.9.22.3:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement-110 mm dia Door Elbow
9950.18.9.22.4:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend
10050.18.9.22.5:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes including jointing with PVC solvent cement 110x110x110 mm dia Tee
10150.18.9.22.6:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x110x110 mm dia Door tee
10250.18.9.22.7:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x110x75 mm dia Door Tee
10350.18.9.22.8:Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl
10450.18.9.22.9:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia offset
10550.18.9.22.11:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia Socket/ coupling
10650.18.9.21:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Elbow
10750.18.9.21.2:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia 45 degree Elbow
10850.18.9.21.3:Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia Door Elbow
10950.18.9.21.4:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Bend
11050.18.9.21.5:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75x75x75 mm dia Tee
11150.18.9.21.6:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75x75x75 mm dia Door Tee
11250.18.9.21.7:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Vent cowl
11350.18.9.21.9:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Socket /coupling
11418.17.1:Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore
11518.17.2:Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore
11618.17.3:Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore
11717.28.1.2:Providing and fixing P.V.C. waste pipe for sink or wash basin including PVC.waste fittings complete.Semi rigid pipe40 mm dia
11818.21.2.1:Providing and fixing uplasticised PVC connection pipe with brass unions:45 cm length15 mm nominal bore
11919.7.1.1:Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weigh of cover 23 kg and weight of frame 15 kg):With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
12019.7.3.1:Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 120x 90 cm and 90 cm deep including C.I. cover with frame ( heavy duty ) 560 mm internal diameter, total weight of cover and frame to be not less than 208 kg ( weight of cover 108 kg and weight of frame 100 kg)With common burnt clay F.P.S. ( non modular) bricks of class designation 7.5
12119.8.2.1:Extra for depth for manholesSize 120x90 cmWith common burnt clay F.P.S. ( non modular ) bricks of class designation 7.5
12219.4.1.1:Providing and fixing square-mouth S.W. gully trap class SP -1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:100x100 mm size P typeWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5
12317.28.2.2:Flexible pipe40 mm dia
124APPENDIX E- Plumbing and Sanitary fittings(Civil work)
12517.78:Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/6 litre (adjustable to 4 litre /8 litres), including seat cover, and cistern fittings, nuts bolts and gasket etc complete.
126OD154235/2024-2025:Providing and fixing Table top wash basin (Rectangular or Oval) size 600 x 400 mm or nearest available size of approved shape and colour, 15 mm C.P. brass High Neck Modular Pillar tap, 32 mm C.P. brass waste of standard pattern, cutting and making good the walls wherever require: White Vitreous China Wash basin size 600 x 400 mm (Rectangular or Oval) with a single 15 mm C.P. brass High Neck Modular Pillar tap
12717.7.2:Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630 x 450 mm with a single 15 mm C.P. brass pillar tap
12817.80:Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx.size 610x390x370 mm having pre & post flushing with water ( 250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer - in-charge.
12917.22A:Providing and fixing CP Brass 32mm size Bottle trap of approved quality & make and as per the direction of Engineer in charge.
13018.18.3:Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete:25 mm nominal bore
13118.51.1:Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore
13218.52.1:Providing and fixing C.P brass stop cock ( concealed) of standard design and of approved make conforming to IS: 893115 mm nominal bore
13318.53.1:Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore
13418.58.2.1:Providing and fixing PTMT grating of approved quality and colour.Rectangular type with openable circular lid150 mm nominal size square 100 mm diameter of the inner hinged round grating
13517.32.1:Providing and fixing mirror of superior glass ( of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Circular shape 450 mm dia
13617.60.1.1:Providing and fixing trap of self cleansing design with screwed down or hinged grating without vent arm complete, including cost of cutting and making good the walls and floors:100 mm inlet and 100 mm outletSand cast iron S & S as per IS : 3989
13750.17.1.1:Supplying and fixing Stainless steel soap dish including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.
13850.17.1.3:Supplying and fixing CP Towel rod 60cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.
13950.17.1.5:Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.
1408.10.2:Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in Charge and finished smooth.Granite Stone of approved shade
141OD157312/2024-2025:Providing and fixing white vitreous closet for physically handicapped person inlcluding cistern, soft close seat cover, 2 Nos wall mounted 600 mm grab bars, 1 No. wall mounted hinged rail 750 mm, 10 litre low level white PVC flushing cistern, including flush pipe, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required
142APPENDIX F- Barrier-free Built Environments(Civil work)
14316.90:Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge.
144APPENDIX G - Yard and Basement Development(Civil work)
14550.2.26.1:Filling with contractor own earth (excluding rock) in open areas in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge.
146OD137439/2023-2024:Surface preparation by using high-end grinding, surface profile machines using diamond tools, scarified and vacuum-assisted systems to achieve the profile with minimized undulations as approved. If any part of the floor is contaminated by grease or oil, the contamination shall be removed, and also remove all laitance and weak or friable concrete to the mechanical profile for better bonding. Opening of cracks and cold joints by groove cutter machine/ manual preparation as per site requirement, including cost of all material, labour charges and hire charges of machines etc. complete as per the direction of the Engineer-in-charge
147OD38916/2023-2024:Primer Application- A coat of low viscous epoxy primer of approved brand and quality (solvent free high build epoxy primer with moisture tolerant properties) shall be applied on the prepared surface by using brush/ roller sufficiently covering the prepared surface. Application of PU coating- The self-levelling Epoxy screed comprises of solvent less Epoxy resin system mixed with Epoxy hardener and formulated aggregates (Compressive Strength: as per ASTM D 695, Tensile strength : ASTM D 638, Elongation: ASTM D 638). The screed is resin rich which enables it to have flow able characteristics. The screed will be laid with the help of serrated trowels and spike rollers to ensure uniform level according to the thickness specified. Self-smoothing Epoxy Screed and sand broadcasting with approved compound on WET to WET Surface and allow to dry for 12 Hours, Clean the excess applied compound and Apply PU 2 coats (Tensile strength : ASTM D 638 >, Elongation: ASTM D 638>, Abrasion resistance ASTM D 4060, mg wt.Loss (CS 17 wheel), PTV Test value as per BS 8204), 2mm thickness including the cost of materials, labour charges and hire charges of machines etc complete as per the direction of Engineer-in-charge.
148OD38917/2023-2024:Supply and application arrow markings medium size bands of polyurethane paint of approved quality, make and colour, lead and chromate free, as specified by manufacturer of traffic coating, thickness DFT of minium 100 microns including cost of all materials, labour charges and hire charges for machines etc. complete as per the direction of Engineer-in-charge.
149OD38918/2023-2024:Supply and application of pavement markings about 100 mm wide bands of approved quality and colour polyurethane paint, lead and chromate free, as specified by the manufacturer of traffic coating, thickness DFT of minimum 100 microns including the cost of all materials and labor charges, hire charges for machinery etc complete as per the direction of Engineer-in- charge.
15016.69:Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature jointed with cement mortar 1:3 ( 1 cement : 3 coarse sand) , including making joints with or without grooves ( thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge ( length of finished kerb edging shall be measured for payment ). ( Precast C.C. kerb stone shall be approved by Engineer-in-Charge)
15116.91.2:Providing and laying factory made chamfered edge Cement Concrete paver blocksin footpath, parks, lawns, drive ways or light traffic parking etc, of required strength,thickness & size/ shape, made by table vibratory method using PU mould, laid inrequired colour & pattern over 50mm thick compacted bed of sand, compacting andproper embedding/laying of inter locking paver blocks into the sand bedding layerthrough vibratory compaction by using plate vibrator, filling the joints with sand andcutting of paver blocks as per required size and pattern, finishing and sweepingextra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern.
152OD53218/2025-2026:Manufacturing, supplying and fixing retro reflective sign boards made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bi-lingual), symbols and borders etc. as per IRC: 67- 2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class-2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c to back support frame of M.S. angle iron of size 25x25x3 mm along with theft resistant measures, mounted and fixed with 2 Nos M.S. angles of size 35x35x5 mm to a vertical post made up to M.S. Tee section ISMT 50x50x6 mm welded with base plate of size 100x100x 5 mm at the bottom end and including making holes in pipes, angles flats, providing & fixing M.S. message plate of required size, steel work to be painted with two or more coats of synthetic enamel paint of required shade and of approved brand & manufacture over priming coat of zinc chromate yellow primer (vertical MS-Tee support to be painted in black and white colours). Backside of aluminium sheet to be painted with two or more coats of epoxy paint over and including appropriate priming coat including all leads and lifts etc. complete as per drawing , specification and direction of Engineer-in-Charge.Mandatory / Regulatory sign boards of 300 mm x 450 mm size with support length of 2400 mm-based on 16.59.1
153OD53216/2025-2026:Providing and laying factory made chamfered edge Cement Concrete grass paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength,thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. grass paver block of M-30 grade with approved color, design, size and pattern.
154APPENDIX H - Compound Wall and Gate(Civil work)
1552.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
1564.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
1575.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
1585.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
1595.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
1605.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
16150.6.1.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.
16213.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
16310.25.2:Item Shifted to Sub head 14 as item 14.73Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
16413.48.1:Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm
16513.52.1:Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
166OD52680/2025-2026:Providing and fixing stainless steel english / malayalam letters having height of 10 cm and 2 cm thick or nearest size, made with 16 gauge SS sheet on the existing surface in the required line and level, etc including the cost of all materials, labour charges, all incidental charges for screws /adhesive, charges for scaffolding, etc complete as per the direction of engineers in charge.
167OD52681/2025-2026:Providing and fixing stainless steel logo 2 cm thick of approved size, made with 16 gauge SS sheet on the existing surface including the cost of materials, labour charges, all charges for scaffolding fixing to required in the correct position, all incidental charges for screws /adhesive etc complete as per the direction of engineers in charge.
168OD346145/2025-2026:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Cement content considered in this item is @ 330 kg/ cum. Excess /Less cement used as per design mix is not payable or recoverable separately. All work upto plinth level
169APPENDIX I - Landscaping works(Civil work)
17030.2.1:Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure).
17130.2.2:Supplying and stacking of good earth at site including royalty and carriage upto 5 k.m. lead complete (earth measured in stacks will be reduced by 20% for payment).
17230.2.4.1:Supplying and stacking at site dump manure from approved source, including carriage upto 5 k.m. lead complete (manure measured in stacks will be reduced by 8% for payment) :Screened through sieve of I.S. designation 20 mm
17330.2.5:Rough dressing the trenched ground including breaking clods.
17430.2.6:Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation.
17530.2.7:Fine dressing of the ground
17630.2.9:Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge
17730.2.8:Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately).
17830.2.10.1:Grassing with selection No. 1 grass including watering and maintenance of the lawn for 60 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the grass and good earth shall be paid for separately).In rows 5 cm apart in both directions
17930.2.29.1:Providing Circular Cement Concrete pots of specified size, cast with cement concrete of nominal mix 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 6 mm nominal size), reinforced with 7 Nos ( 3 nos horizontal & 4 nos vertical “ U “ shape) M.S. wires of 3.5 mm dia as per design, including required form work, finishing with cement punning on exposed surface, curing for specified period and stacking in required rows & height, all complete as per direction of Officer-in-charge.Top inside dia 35 cm, outer bottom dia 25 cm, total height 35 cm with wall thickness of 25.4 mm
18030.2.31.7:Filling of the following size empty pots with mixture of good earth & manure in the ratio of 2:1 (Two part of Good earth & one port of manure) and placing them on approprite place i/c carriage of earth, manure and pots up to 50 mtr, as per direction of officer incharge. (The cost of good earth, earthen pots & manure will be paid seperately.)Size of Empty Pots 35cm Top dia, 25cm Bottom Dia & 35cm Perpendicular height
181OD52640/2025-2026:Providing and stacking of Ficus Iyrata of height 45-60 cm. in pots of size 25 cm or nearest as per direction of the officer-in-charge.
182OD52641/2025-2026:Providing and stacking of Ficus bengalensis krishna of height 75-90 cm., multi-branched in pots of size 30 cm or nearest as per direction of the officer-in-charge
183OD52666/2025-2026:Providing and stacking of Ficus bengalensis (varigated) of height 75-90 cm., multi-branched in pots of size 30 cm or nearest as per direction of the officer-in-charge.
184OD52667/2025-2026:Providing and stacking of Delonix regia (Gulmohar) of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge
185OD52668/2025-2026:Providing and stacking of Cassia fistula (Amaltash) of height 120-135 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge
186OD52670/2025-2026:Providing and stacking of Callistemon lanceolatus of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.
187OD52671/2025-2026:Providing and stacking of Bauhinia blakeana (Kachnar) of height 120-150 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.
188OD52672/2025-2026:Providing and stacking Bignonia venusta (Golden shower) of height 30 cm to 45 cm. in 20 cm size or nearest of Earthen pots / Plastic pots/ planter box & as per direction of the officer-in-charge.
189APPENDIX K - Signage(Civil work)
190OD52601/2025-2026:ACRYLIC NAME PLATES (wall fixing ): Providing and fixing of Prohibition , and information signage , name plates , made of casted acrylic (4mm Thick) duly laser cut and text and pictograms (Make:AVERY DENNISON.) PVC Vinyl reverse pasting method. or electro cut , all fixing arrangements is (ss 304 grade) mirror fasteners stainless steel screw with cap as per design. fixing as per design at the required location as per the direction of Engineer in Charge.including cost of all creative designing ,materials , labor charge , etc complete. FLOOR DIRECTORY BOARD , way finding arrow board (Display each floor , department details in each board) : SIZE: 80x60cm
191OD52602/2025-2026:ACRYLIC NAME PLATES (wall fixing ): Providing and fixing of Prohibition , and information signage , name plates , made of casted acrylic (4mm Thick) duly laser cut and text and pictograms (Make:AVERY DENNISON.) PVC Vinyl reverse pasting method. or electro cut , all fixing arrangements is (ss 304 grade) mirror fasteners stainless steel screw with cap as per design. fixing as per design at the required location as per the direction of Engineer in Charge.including cost of all creative designing ,materials , labor charge , etc complete. MAIN DIRECTORY BOARD(Display all floor deatils includes in one board): SIZE: 120X80 cm
192OD52622/2025-2026:ACRYLIC NAME PLATES (wall fixing ): Providing and fixing of Prohibition , and information signage , name plates , made of casted acrylic (4mm Thick) duly laser cut and text and pictograms (Make:AVERY DENNISON.) PVC Vinyl reverse pasting method. or electro cut , all fixing arrangements is (ss 304 grade) mirror fasteners stainless steel screw with cap as per design. fixing as per design at the required location as per the direction of Engineer in Charge.including cost of all creative designing ,materials , labor charge , etc complete. ROOM NAME PLATES, AND WARNING SIGNAGES AND INFORMATION SIGANGES,..OT , WAITING AREA, … etc.. SIZE: 80X20cm
193OD52623/2025-2026:ACRYLIC NAME PLATES (wall fixing ): Providing and fixing of Prohibition , and information signage , name plates , made of casted acrylic (4mm Thick) duly laser cut and text and pictograms (Make:AVERY DENNISON.) PVC Vinyl reverse pasting method. or electro cut , all fixing arrangements is (ss 304 grade) mirror fasteners stainless steel screw with cap as per design. fixing as per design at the required location as per the direction of Engineer in Charge.including cost of all creative designing ,materials , labor charge , etc complete. ROOM NAME PLATES, AND WARNING SIGNAGES AND INFORMATION SIGANGES,TOILET , WASH AREA, SCRUB AREA, NO SMOKING … etc.. SIZE: 45X12cm
194OD52626/2025-2026:MAIN MASTER BOARD SITE IDENTIFICATION : Made of 3 mm thick aluminium composite panel (ACP) (Make 'Alutec' or equalent) base which over painted with high quality latex printed self adhesive vinyl as per the design and drawing, and frame work must minimum 18 guage 2 inch square tube structure frame work , print covered with 3mm thick clear acrylic. The Minimum height from the ground to bottom of the board is 120 cm. ground fixing the board with cement concrete.fixing the correct locations as per the direction of engineer incharge: including cost of all creative designing ,materials , labour charge , etc complete. Size:182x121 cm
195OD52627/2025-2026:MAKING, SUPPLY AND FIXING OF EMERGENCY EVACUATION PLAN : Made of 3mm thick PVC foam sheet painted with Auto glow PVC self adhesive vinyl. Metal framed (fire resistant) and 3mm glassed and fixed at specified positions as directed by Engineer. ie ward reception , corridor , waiting area etc.. including cost of all creative designing ,materials , labour charge , etc complete. : Size: 49x33 cm
196OD52633/2025-2026:Providing and fixing in position the signages " FIRE ORDER" it should contain the following matter. (With the Reference of standard of fire signage guideline and NBC ) Made of 4mm thick PVC foam board with computer cut, PVC non-reflective (auto glow)self adhesive vinyl painted foam board, all fixing arrangements with ss 304 grade mirror fastners screw with cap,shall be fixed at the height of 2 mts from finished floor near Manual call points,LIFT LOBBY,SECURITY ,WAITING ARAEA, RECEPTION,WARD,PASSAGE etc, and if other important locations if referred, including cost of all creative designing ,materials , labour charge , etc complete. Size: 45x60 cm. Design as specified by Engineer In Charge
197OD52634/2025-2026:Providing and Fixing in position the following type of sign boards (With the reference of Standard of fire signage guideline and NBC) made of 4mm thick PVC foam board with computer cut, PVC non-reflective (auto glow)self adhesive vinyl painted foam board, all fixing arrangements with ss 304 grade mirror fastners screw with cap. including cost of all creative designing ,materials , labour charge , etc complete. Providing and fixing of floor identification signage : LGF,UGF, , GROUND FLOOR , FIRST FLOOR ,SECOND FLOOR .. Etc Size: 45X12 cm
198OD52635/2025-2026:Providing and Fixing in position the following type of sign boards (With the reference of Standard of fire signage guideline and NBC) made of 4mm thick PVC foam board with computer cut, PVC non-reflective (auto glow)self adhesive vinyl painted foam board, all fixing arrangements with SS 304 grade mirror fastners screw with cap. including cost of all creative designing ,materials , labour charge , etc complete. Providing and Fixing of LIFE SAFETY RELATED (EXIT,DIRECTION ARROWS ie LEFT, RIGHT, STRAIGHT,UP, DOWN , BOTH WAY ) as per the site condition and the reference of standard of escape signage guideline ?etc , Size: 10X30CM
199OD52636/2025-2026:Providing and Fixing in position the following type of sign boards (With the reference of Standard of fire signage guideline and NBC) made of 4mm thick PVC foam board with computer cut, PVC non-reflective (auto glow)self adhesive vinyl painted foam board, all fixing arrangements with ss 304 grade mirror fastners screw with cap. including cost of all creative designing ,materials , labour charge , etc complete. Providing and Fixing of Identification name plates: FIRE HOSE REEL, FIRE EXTINGUISHER,FIRE ALARM, MCP,FIRE DUCT ?etc , Size: 10X30CM
200OD52637/2025-2026:Providing and Fixing in position the following type of sign boards (With the reference of Standard of fire signage guideline and NBC) made of 4mm thick PVC foam board with computer cut, PVC non-reflective (auto glow)self adhesive vinyl painted foam board, all fixing arrangements with SS 304 grade mirror fasteners screw with cap. including cost of all creative designing ,materials , labour charge , etc complete. Signage with printed "IN CASE OF FIRE, USE STAIRS UNLESS INSTRUCTED OTHERWISE" of 1.5cm height letters in red with white back ground(AUTO GLOW).The size of the board shall be 25cm x 30 cm and shall be fixed at the height of 2 mts. (Reference of standard of fire signage guideline and NBC ) from finished floor near LIFT LOBBY, and if other important locations if referred Auto Glow. Size: 25x30cm.
201Transformer, DG, Electrfication and lightning protection(Electrical work)
202OD159965/2024-2025: Supply ,installation,testing and commissioning of 500KVA USS , 11kv/433v,50hz,3phase,AN cooled,delta/star,with copper windings with tappings +5 to -5 in steps of 2.5%, class f insulation, Indoor type ,laser scribed core ,confirming to ECBC norms , copper interconnections , with 11KV,630A, VCB ,26.3KA for 3 sec, horizontal drawout fitted with manual spring charged etc complete with necessary multifunction meter ,11KV CT & PT ,master trip relay,push button ,provision for TOD meter,annunciation panel with alarm,strip heater,thermostat etc complete enclosed in CRCA powder coated sheet conforming to IP 23 of minimum thickness 2mm.
203OD52586/2025-2026: Supply, conveyance, Installation, testing and commissioning of 11 kV 630A 3 pole VCB add on breaker, SF6 insulated, outdoor type motor operated, extensible one way, with jointing box suitable to couple with existing RMU. Add on shall be with terminal protectors protection relays with all materials complete conforming to relevant IS/ IEC standards and as per KSEB specifications as required.
204OD192803/2025-2026:Supply, installation, programming, testing, and commissioning of a complete PLC-based automation system using SMART PLC for the control and automation of electrical loads and power sources in existing MSB panels. The scope of work includes complete wiring with all control components (wires, relays, connector, numbering ferules etc) and interfacing of the PLC with multifunction energy meters, plug-in relays, SMPS units, and other protective devices. All components shall be properly installed, labeled, and integrated within the panel infrastructure. The system shall communicate using the MODBUS protocol over RS-485, enabling real-time data exchange between the PLC and connected field devices. The PLC shall be programmed to monitor real-time parameters such as grid (KSEB) availability, generator readiness, and load thresholds. Based on these conditions, the system will perform logical decision-making for source switching and load sharing, including the use of interlocks and priority-based control logic. Setpoints and operational parameters shall be configured to ensure automatic failover and safe recovery during power outages or equipment faults. Upon completion of installation, the system will undergo comprehensive testing, including load simulation and sequence verification. The commissioning process will include validation of both automatic and manual operating modes, as well as training for the operator or maintenance team. Make of PLC: Siemens S7-200 SMART or equivalent approved make. Scope Includes: All required control wiring, programming, testing tools, software loading, system documentation, and final commissioning reports in compliance with applicable IS standards and submit all control wiring diagram with PLC programming manual etc as required.
205OD159967/2024-2025:Supply ,Conveyance Installation ,Testing and Commissioning of 500 KVA CPCB IV+ norms DG set as per the technical details given below. Engine. a. Make of Engine - As specified in accepted list of material. b. Type of Engine-Diesel Engine.c.No. of cylinder- Suitable to develop the required BHP as per manufacturer's standards. d.Method of cooling - Water cooling(with radiator) e. Aspiration - Turbo charged after cooled. f. Design - Suitable for generator set application. g. Out put - BHP at 1500 RPM under NTP conditions or other BHP ratings Specified by the respective manufactures capable of delivering the required power for alternator. Standard accessories with diesel engine. a. Fly wheel housing and flywheel to suit single bearing alternator (Close coupled arrangement).b. Air cleaner, c. Coolent kit.d, Fuel Pump, e Electronic governor backed with mechanical governor. f. Fuel filter. g .Lubricating oil filter, h. Residential type exhaust silencer. Engine Instrument Panel. a. starting switch with key or button .b. Lubricating oil temperature gauge. c.Lubricating oil pressure gauge, d. Water temperature gauge. e.RPM Indicator with hour meter. f. Battery charging ammeter. Safety Controls for Engine-a.Trip for low lubricating oil pressure. b.Trip for high water temperature. c.Providing necessary warning system and other safeties as contemplated in relevant ISS. d.Fuel shut off facility at over speed. Fuel pipe.Oil resistant flexible hoses & 25mm dia or nearest size MS pipe as per manufactures requirement for fuel line. Alternator-a.make-As specified in accepted make of material .b .Type - Self excited and self regulated. capacity - 500 KVAat 0.8 PF. d. System of voltage - 3 phase, 415V. e.Speed - 1500 RPM. f. Voltage regulation band - 2.50% of rated Voltage .g. Insulation - Class F/H. h. AVR - AVR shall be provided with a motorized or solid state potentiometer. i.IP rating of enclosure - IP 23.j. Wave form distortion - No load<1.5%, non-distorting balanced linear load<5%.k.Telephone interference factor - Better than 50 l. Total harmonic factor - Better than 2%. Standard control panel with suitably rated MCCB with overload and E/F release and standby low set earth fault relay using neutral CT .The alternator should confirm to IS 4722. Routine tests as per relevant ISS shall be conducted and test reports of the same shall be furnished at the time of delivery. Fuel tank-Integral type fuel tank of adequate capacity. Battery-Required number of suitably rated fully charged battery with leads and terminals as required as per manufactures requirements. Battery Charger: supply and providing 24V battery charger suitable for charging battery of DG Set (180 Ah) consisting of the following. a. Transformer / Rectifier with surge protection device. b. Charging facility for 12V & 24 V battery. c. DC Volt Meter. d. DC Ammeter to indicate both charging and discharging current. e. Selector Switch for trickle and boost charging. f. Automatic overcharge cut off facility .Acoustic enclosure: a, The DG set shall be supplied along with specially designed company fabricated (to be fabricated in the same company firm where the DG set delivered) acoustic enclosure to meet the stringent MOEF/ CPCB norms of 75 dBA@ 1m at 75% load under free field conditions. b. Sufficient space and clearance shall be maintained inside the enclosure to have optimum serviceability. c. Air inlet louvers shall be designed in such a way as to operate the set at rated load even at 50ºC enclosure temperature. d. The enclosure shall be with UV resistant powder coating capable to withstand extreme environments. e. Hardware used shall be of only stainless steel make, f. Insulation material shall confirm to IS 8183 specification. Documents to be supplied :a. Engine manual, b. Spare parts book, c. Warranty certificate, d. Alternator manual & test certificate, e.1 set control wiring drawing. Installation: It shall be installed in the pre-constructed concrete bed complying to relevant IS standards, IE rules and as per the direction of the official. Testing and commissioning: The DG set shall be tested as per relevant IS standards. Block load testing shall also be conducted and DG should have capacity to withstand block load of 55%.The load required for testing shall be made available at site by the selected agency at their own expense. During defect liability period ,periodical checkup & services as per manufacturers recommendation and repair shall be arranged and any spare/component which require replacement /repair shall be done immediately at free of cost.
20690.14.8.11:800 A, 4 pole, manual draw out type, microprocessor based ACB with overload , instantaneous SC , delayed SC and ground fault protection 50kA
207OD187586/2025-2026:Supply and installation of Instantaneous Under Voltage release for ACBs as required.
208OD187587/2025-2026:Supply and installation of Shunt release for ACBs as required.
209OD187588/2025-2026:Supply and fixing Closing Coil for ACBs as required.
210OD120509/2025-2026:Supply installation testing and commissioning of over current/earth fault relay for ACBs as required
211OD290641/2025-2026:Supply and fixing 3 phase, 4 wire,110 V(L-L), 1A CT or 5A CT, accuracy class 0.2S,TOD meter in the existing panel assembly and giving connection etc as required.
212OD159968/2024-2025:Supply and filling Diesel for DG set as required
213OD187559/2025-2026:Providing, laying, testing and commissioning of C class heavy duty M S Pipe conforming to IS 3589,IS 1239 i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required:125mm dia
21418.7.8:Providing, laying, testing and commissioning of C class heavy duty M S Pipe conforming to IS 3589,IS 1239 i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required:150mm dia
21518.7.9:Providing, laying, testing and commissioning of C class heavy duty M S Pipe conforming to IS 3589,IS 1239 i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required:200mm dia(Wall thickness 6.3mm)
216OD286757/2025-2026:Supply and providing cladding for 200mm dia MS exhaust pipe using 50mm thick glass wool /mineral wool /rock wool density not less than 120Kg/m3 and aluminium cladding (0.6mm thick). as required.
217OD286771/2025-2026:Supply and providing cladding for 150mm dia MS exhaust pipe using 50mm thick glass wool /mineral wool /rock wool density not less than 120Kg/m3 and aluminium cladding (0.6mm thick).
218OD182908/2025-2026:Supply and providing Cladding for 125mm Exhaust pipe using 10 inch dia aluminium cladding with 26 gauge aluminium sheet ,Rock wool ,chicken mesh etc as required.
219OD286783/2025-2026:Supply and Laying of 11KV, 3 core 300 sqm stranded compact circular aluminium conductor, conductors screened with extruded semi conducting compound XLPE insulated, insulation screened with extruded semi conducting compound in combination with copper tape (0.3KA for I sec.) cores laid up. inner sheath of PVC tape, galvanized steel flat strip armoured, and overall PVC sheathed cable conforming to IS: 7098 part II 1985 with latest amendments in the existing RCC/ HUME/ METAL pipe as required
220OD159973/2024-2025:Supply and laying 3 core 300 sqm 11 kV stranded compact circular aluminium conductor, conductors screened with extruded semi conducting compound XLPE insulated, insulation screened with extruded semi conducting compound in combination with copper tape (0.3KA for I sec.) cores laid up. inner sheath of PVC tape, galvanized steel flat strip armoured, and overall PVC sheathed cable conforming to IS: 7098 part II 1985 with latest amendments in existing masonry open duct and giving connection as required.
22110.4.4:Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm
22210.5.4:Supplying and making outdoor cable end termination with heat shrinkable jointing kit completewith all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductorcable of 11 KV grade as required :300 sq. mm
223OD159971/2024-2025:MANUAL CALL POINT:- Supply Installation, Testing and Commissioning of Manual Call Points of break glass type with hammer and chain as required
224OD54368/2025-2026:Supply and fixing water proof emergency stop Rotary Self-locking Push-button Switch with IP65 protection and giving connections required.
225OD187419/2025-2026:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 2 core 2.5 sq mm with factory made clamp
226OD187563/2025-2026:Supply and drawing of 2.5 sqmm 6 core PVC/ XLPE insulated armoured control cables with copper conductors for working voltages up to and including 1100 V conforming to IS 1554 part I 1988 for PVC and IS 7098 Part I for XLPE with the cables, one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required
227OD187564/2025-2026:Supply, laying and clamping of 2.5 sqmm 6 core PVC / XLPE insulated armoured control cables with copper conductors for working votages up to and including 1100 V conforming to IS 1554 part I 1988 for PVC and IS 7098 Part I for XLPE, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required
2282.22:Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
2292.21:Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
230OD54260/2025-2026:Excavation for entry/exit pits in Tarr/Berm/Concrete road, Installation of 110 mm HDPE pipe using HDD (Horizontal Directional Drilling) method with all accessories for laying HDPE pipe suitable for HT UG cables and Back fill of entry/exit pits after pipe installation.
231OD187593/2025-2026:Supply PE 100 DN 110 PN 10 HDPE pipe and laying HT UG cables through existing horizontal direct drilled path
23290.12.12.6:Supply & laying of DWC pipe in ordinary soil 1.2 m below ground level including excavation110/94 mm or nearest size
23390.12.9.6:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench110/94 mm or nearest size
234OD259124/2025-2026:Supply ,laying and fixing of one number PVC insulated and PVC sheathed / XLPE Aluminium conductor armoured power cable of 1.1 KV grade conforming to IS 1554/(part I)/1988 for PVC & IS 7098/(part I )/1988 for XLPE of following size on wall surface as required. 2x6 sqmm (clamped with 1mm thick saddle)
235OD259126/2025-2026:Supply and laying of one number PVC insulated and PVC sheathed / XLPE aluminium armoured power cable of 1.1 KV grade conforming to IS 1554/(part I)/1988 for PVC & IS 7098/(part I)/1988 for XLPE of following size in the existing RCC/ HUME/ METAL pipe as required . 2x6sqmm
236OD259136/2025-2026:Supply ,laying and fixing of one number PVC insulated and PVC sheathed / XLPE Aluminium conductor armoured power cable of 1.1 KV grade conforming to IS 1554/(part I)/1988 for PVC & IS 7098/(part I)/1988 for XLPE of following size on cable tray as required. 2x10sqmm (clamped with 1mm thick saddle)
237OD259163/2025-2026:Supply ,laying and fixing of one number PVC insulated and PVC sheathed / XLPE Aluminium conductor power cable of 1.1 KV grade conforming to IS 1554/(part I)/1988 for PVC & IS 7098/(part I)/1988 for XLPE of following size on wall surface as required. 4x10 sqmm (clamped with 1mm thick saddle)
238OD259288/2025-2026:Supply ,laying and fixing of one number PVC insulated and PVC sheathed / XLPE Aluminium conductor power cable of 1.1 KV grade conforming to IS 1554/(part I)/1988 for PVC & IS 7098/(part I)/1988 for XLPE of following size on wall surface as required. 4x16 sqmm (clamped with 1mm thick saddle)
239OD259303/2025-2026:Supply ,laying and fixing of one number PVC insulated and PVC sheathed / XLPE Aluminium conductor power cable of 1.1 KV grade conforming to IS 1554/(part I)/1988 for PVC & IS 7098/(part I)/1988 for XLPE of following size on wall surface as required. 4x25 sqmm (clamped with 1mm thick saddle)
240OD259307/2025-2026:Supply ,laying and fixing of one number PVC insulated and PVC sheathed / XLPE Aluminium conductor power cable of 1.1 KV grade conforming to IS 1554/(part I)/1988 for PVC & IS 7098/(part I)/1988 for XLPE of following size on wall surface as required. 4x35 sqmm (clamped with 1mm thick saddle)
241OD259342/2025-2026:Supply ,laying and fixing of one number PVC insulated and PVC sheathed / XLPE Aluminium conductor power cable of 1.1 KV grade conforming to IS 1554/(part I)/1988 for PVC & IS 7098/(part I)/1988 for XLPE of following size on wall surface as required. 3.5x50 sqmm (clamped with 25x3mm MS flat clamp)
242OD259344/2025-2026:Supply ,laying and fixing of one number PVC insulated and PVC sheathed / XLPE Aluminium conductor power cable of 1.1 KV grade conforming to IS 1554/(part I)/1988 for PVC & IS 7098/(part I)/1988 for XLPE of following size on wall surface as required. 3.5x70 sqmm (clamped with 25x3mm MS flat clamp)
243OD259345/2025-2026:Supply ,laying and fixing of one number PVC insulated and PVC sheathed / XLPE Aluminium conductor power cable of 1.1 KV grade conforming to IS 1554/(part I)/1988 for PVC & IS 7098/(part I)/1988 for XLPE of following size on wall surface as required. 3.5x120 sqmm (clamped with 25/40x3mm MS flat clamp)
244OD259347/2025-2026:Supply ,laying and fixing of one number PVC insulated and PVC sheathed / XLPE Aluminium conductor power cable of 1.1 KV grade conforming to IS 1554/(part I)/1988 for PVC & IS 7098/(part I)/1988 for XLPE of following size on wall surface as required. 3.5x150 sqmm (clamped with 25/40x3mm MS flat clamp)
245OD259354/2025-2026:Supply ,laying and fixing of one number PVC insulated and PVC sheathed / XLPE Aluminium conductor power cable of 1.1 KV grade conforming to IS 1554/(part I)/1988 for PVC & IS 7098/(part I)/1988 for XLPE of following size on wall surface as required. 3.5x185 sqmm (clamped with 25/40x3mm MS flat clamp)
246OD259355/2025-2026:Supply ,laying and fixing of one number PVC insulated and PVC sheathed / XLPE Aluminium conductor power cable of 1.1 KV grade conforming to IS 1554/(part I)/1988 for PVC & IS 7098/(part I)/1988 for XLPE of following size on wall surface as required. 3.5x240 sqmm (clamped with 40x3mm MS flat clamp)
247OD290648/2025-2026:Supply and laying of one number PVC insulated and PVC sheathed / XLPE aluminium armoured power cable of 1.1 KV grade conforming to IS 1554/(part I)/1988 for PVC & IS 7098/(part I)/1988 for XLPE of following size in the existing RCC/ HUME/ METAL pipe as required. 3.5x240 sqmm
2489.1.1:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm)
2499.1.2:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm)
2509.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
2519.1.33:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
2529.1.34:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)
2539.1.21:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm)
2549.1.22:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)
2559.1.23:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)
2569.1.25:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 120 sq. mm (45mm)
2579.1.26:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 150 sq. mm (50mm)
2589.1.27:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)
2599.1.29:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm)
260OD289445/2025-2026:Supplying and providing earth clamps for siemens/ tropodor type cable glands of suitable length and other dimensions noted along with each size of glands for the following sizes of cables as required.25 sq mm to 95 sq mm size cable with 20 mm wide x 1.2 mm thick clip
261OD289446/2025-2026:Supplying and providing earth clamps for siemens/ tropodor type cable glands of suitable length and other dimensions noted along with each size of glands for the following sizes of cables as required.1.5 sq mm to 16 sqmm size cable with 12 mm wide x 1 mm thick clip
262OD289447/2025-2026:Supplying and providing earth clamps made out of copper strips of the following sizes including cutting and bending the flat exactly to the shape of the gland, drilling necessary holes for nut & bolt, tinning the points of contacts and giving connections to the main earthling system as required.20 x 3 mm for earthing glands of size 120 sq mm to 185 sq mm
263OD289448/2025-2026:Supplying and providing earth clamps made out of copper strips of the following sizes including cutting and bending the flat exactly to the shape of the gland, drilling necessary holes for nut & bolt, tinning the points of contacts and giving connections to the main earthling system as required.25 x 3 mm for earthing glands of size 240 sq mm to 300 sq mm
264OD187603/2025-2026:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation 40/32 mm or nearest size
265OD194188/2025-2026:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench 40/32 mm or nearest size
266OD187420/2025-2026:Supply and providing plate earthing with 1200x1200x12mm GI earth plate,50 mm GI(medium class) watering pipe, GI funnel with weld mesh,25x5 mm GI clamps, GI/MS cover plate with locking arrangements, charcoal/coke and salt etc. including providing brick work masonry enclosure at the top (450x450x450mm inside)etc. as required.
2675.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
2685.8:Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
2695.10:Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
2705.14:Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
27190.16.3.9:Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)25 x 3 mm copper strip
27290.16.4.8:Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).25 x 3 mm copper strip
273OD193977/2025-2026:Supplying and laying 25 mm X 3 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm}
274OD259034/2025-2026:Providing and drawing 4.75 mm(6SWG) copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
27590.16.5.5:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.75 mm (6 SWG)
27614.13.1:Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required50 mm dia
277OD187423/2025-2026:Supply, Conveyance ,Installation, Testing and Commissioning of Four pole AC 315A, 50 Hz, 415V Automatic Transfer Switch (ATS) along with AuXC C 2000 controller having protection from UV/OV, Single phasing, Phase sequence and Frequency with Complete protection,5 key s navigation keypad for parameters setting,4 LEDs for plant synoptic (source line and ATS status) ,2 LEDs for alarm presence and AUTO mode active 128x 80 pixel, Backlit LCD screen with 4 Grey levels, Management of generator set start-stop & cooling cycle Management of automatic test for generators with emergency and rotation conforming to IS/IEC 60947-3, EN 60947-3 IS/IEC 60947-6-1, EN 60947-6-1 in existing panel including connections, etc. as required. Make L& K or equivalent.
278OD187431/2025-2026:Supply, Conveyance ,Installation, Testing and Commissioning of Four pole AC 200A, 50 Hz, 415V Automatic Transfer Switch (ATS) along with AuXC C 2000 controller having protection from UV/OV, Single phasing, Phase sequence and Frequency with Complete protection,5 key s navigation keypad for parameters setting,4 LEDs for plant synoptic (source line and ATS status) ,2 LEDs for alarm presence and AUTO mode active 128x 80 pixel, Backlit LCD screen with 4 Grey levels, Management of generator set start-stop & cooling cycle Management of automatic test for generators with emergency and rotation conforming to IS/IEC 60947-3, EN 60947-3 IS/IEC 60947-6-1, EN 60947-6-1 in existing panel including connections, etc. as required. Make L& K or equivalent.
279OD187436/2025-2026:Supply, Conveyance ,Installation, Testing and Commissioning of Four pole AC 160A, 50 Hz, 415V Automatic Transfer Switch (ATS) along with AuXC C 2000 controller having protection from UV/OV, Single phasing, Phase sequence and Frequency with Complete protection,5 key s navigation keypad for parameters setting,4 LEDs for plant synoptic (source line and ATS status) ,2 LEDs for alarm presence and AUTO mode active 128x 80 pixel, Backlit LCD screen with 4 Grey levels, Management of generator set start-stop & cooling cycle Management of automatic test for generators with emergency and rotation conforming to IS/IEC 60947-3, EN 60947-3 IS/IEC 60947-6-1, EN 60947-6-1 in existing panel including connections, etc. as required. Make L& K or equivalent.
280OD289396/2025-2026:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & shall conform to relevant IS .Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 2mm CRCA sheet, powder coated (excluding base frame)
28190.14.2.1:Supply and providing 2mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.
28290.14.2.2:Supply and providing 3mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.
28390.14.3.1:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardA' section neoprene beeding suitable for 1.60/ 2.00 mm sheet
28490.14.4:Supply and fabrication conveyance and installation of base frame of panel board using 75 x 40 mm rolled steel channel (ISMC)
28590.14.6:Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required.
28690.14.7:Supply and providing copper earth bus in the panel board
287OD187437/2025-2026:SITC of Panel include 3Ph pluggable type surge arrester in suitable enclosure Class B+C/ Type 1+2 as per IEC 61643 -11 for lightning current equipotential bonding to VDE 0185-305 (IEC 62305). Modular connectable arrestor with dynamic cut-off unit and visual status display for each cartridge. It should be included Locking mechanism with vibration protection and voltage keying for safe operation of the device. Nominal voltage -230V 50Hz, type single MOV with built in thermal fuse and cooling gel(L to N) & spark gap encapsulated / non exhausting (N to E) . Total Lightning Impulse Current - 37.5 kA (10/350µ sec) for Line to Neutral & 50 kA(10/350µ sec) for Neutral to Earth, Total Nominal discharge current- 90 kA (8/20µ sec) for Line to Neutr al & 50 kA(8/20µ sec) for Neutral to Earth, Total Max discharge current - 200 kA (8/20µ sec). Voltage protection level 1400V (L to N) & 1500V (N to E). Operating temp -40º to +80ºC. Response time <25 nano sec (L to N), < 100 nano sec (N to E) DIN rail mounting type etc complete with back up fuse as required and as directed, TOV tested. The product should be tested and approved by any one of the following external testing institute(UL, KEMA, OVE, VDE)
288OD54897/2025-2026:Supply and installation of Type 1+2, Surge Protection Device having Configuration 3P+N , 4 module, Maximum Discharge Current - Imax up to 50KA, Iimp: 12.5KA, in the existing enclosure and giving connections as required , (L&T Mate or equivalent )
28990.14.10.1:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 16 kA (Ics=100%Icu), 3 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL
29090.14.10.3:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 16 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL
2912.2.14:Providing and fixing following rating and breaking capacity MCCB withthermomagnetic release and terminal spreaders in existing cubicle panel boardincluding drilling holes in cubicle panel. making connections. etc. as required.125 Amp, 36 KA
29290.14.10.12:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.160A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC
2932.2.15:Providing and fixing following rating and breaking capacity MCCB withthermomagnetic release and terminal spreaders in existing cubicle panel boardincluding drilling holes in cubicle panel. making connections. etc. as required.200 Amp, 36 KA
2942.2.16:Providing and fixing following rating and breaking capacity MCCB withthermomagnetic release and terminal spreaders in existing cubicle panel boardincluding drilling holes in cubicle panel. making connections. etc. as required.250 Amp, 36 KA
29590.14.10.17:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.320A/400A, 50/55 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC
29690.14.10.14:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.250A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC
29790.14.11.13:MCCB AccessoriesSupply and fixing rotary handle, External type (including BUC handle with door interlock ) in the existing MCCB of rating up to 250 A
29890.14.11.15:MCCB AccessoriesSupply and fixing rotary handle, External type (including BUC handle with door interlock ) in the existing MCCB of rating up to 315-630 A
299OD187614/2025-2026:Supply and providing spreader/terminal adapter kit extended terminal for 4 pole MCCB of rating 320A(8 pcs)
300OD187617/2025-2026:Supply and providing spreader/terminal adapter kit extended terminal for 4 pole MCCB of rating 250A(8 pcs)
301OD159977/2024-2025:Supply and providing spreader/terminal adapter kit extended terminal for 4 pole MCCB of rating 160A & 200A(8 pcs)
302OD159979/2024-2025:Supplying and fixing of BS type 160A offset bolted type HRC Fuse and link in the existing panel board as required.
303OD54319/2025-2026:Supplying and fixing of BS type 200 A offset bolted type HRC Fuse and link in the existing panel board as required.
304OD159980/2024-2025:Supplying and fixing of BS type 320 A offset bolted type HRC Fuse and link in the existing panel board as required.
305OD159981/2024-2025:Supply and fixing of 100 A, 2 Way neutral links mounted on DMC/SMC base and its connected accessories as required
306OD159982/2024-2025:Supply and fixing of digital type Multi function meter of 1 accuracy class with backlit LED display, built in selector switch for measuring all electrical parameters like V, A, F, PF 3 phase accuracy class 1 suitable for flush mounting complete as required.
307OD159983/2024-2025:supply and fixing of Three Phase Voltmeter accuracy class 1 with necessary connected item as required
308OD194293/2025-2026:Supply and Fixing of Illuminated Flush head Actuator - Green with legend 'ON', (Contact - 1 NO) and giving connection as required.
309OD194294/2025-2026:Supply and Fixing of Illuminated Flush head Actuator - Red with legend 'OFF', (Contact - 1 NC) and giving connection etc as required.
310OD159984/2024-2025:supply and fixing of Single Phase Ammeter accuracy class 1 with necessary connected item as required
311OD187622/2025-2026:Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 for interconnecting the control devices/equipments including providing suitable size insulated sockets at the termination points or soldered properly,providing numbering ferules for the proper identification of the wiring, keeping the wiring firm by suitable tie/tie mounts/PVC duct etc as required. 6.00sq mm wire single run
312OD187623/2025-2026:Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 for interconnecting the control devices/equipments including providing suitable size insulated sockets at the termination points or soldered properly,providing numbering ferules for the proper identification of the wiring, keeping the wiring firm by suitable tie/tie mounts/PVC duct etc as required. 4.00sq mm wire single run
313OD187624/2025-2026:Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 for interconnecting the control devices/equipments including providing suitable size insulated sockets at the termination points or soldered properly,providing numbering ferules for the proper identification of the wiring, keeping the wiring firm by suitable tie/tie mounts/PVC duct etc as required. 2.50sq mm wire single run
314OD187625/2025-2026:Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 for interconnecting the control devices/equipments including providing suitable size insulated sockets at the termination points or soldered properly,providing numbering ferules for the proper identification of the wiring, keeping the wiring firm by suitable tie/tie mounts/PVC duct etc as required.1.50sq mm wire single run
315OD289358/2025-2026:Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 for interconnecting the control devices/equipments including providing suitable size insulated sockets at the termination points or soldered properly,providing numbering ferules for the proper identification of the wiring, keeping the wiring firm by suitable tie/tie mounts/PVC duct etc as required.16.00sq mm wire single run
316OD289362/2025-2026:Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 for interconnecting the control devices/equipments including providing suitable size insulated sockets at the termination points or soldered properly,providing numbering ferules for the proper identification of the wiring, keeping the wiring firm by suitable tie/tie mounts/PVC duct etc as required.10.00sq mm wire single run
3177.10:Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
318OD159989/2024-2025:Supply and providing 150 mm panel mounting cooling fan with fresh air grill as required.
319OD159990/2024-2025:Supply and providing Red, Green, Black, Yellow, Orange colours LED indicators, AC/DC 22.5mm cut out dia
320OD159991/2024-2025:Supply and providing Blue colour LED indicator lamp, AC/DC, 22.5 cm cut out dia
321OD118250/2025-2026:Supply, Installation, Testing and commissioning of 800/5 A, 15 VA, accuracy class 0.5, Resin Cast Metering CT as required
322OD159993/2024-2025:Supply, Installation, Testing and commissioning of 300/5 A, 5 VA, accuracy class 1, Resin Cast Metering CT as required
323OD118252/2025-2026:Supply, Installation, Testing and commissioning of 200/5 A, 5 VA, accuracy class 1, Resin Cast Metering CT as required
324OD118251/2025-2026:Supply, Installation, Testing and commissioning of 150/5 A, 5 VA, accuracy class 0.5, Resin Cast Metering CT as required
325OD159992/2024-2025:Supply, Installation, Testing and commissioning of 120/5 A, 5 VA, accuracy class 1, Resin Cast Metering CT as required
326OD194357/2025-2026:Supplying and fixing 2A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
327OD159996/2024-2025:Supply and providing Cable alley, 100 x 40 mm aluminium anodised legend plates in the existing panel board as required.
328OD159997/2024-2025:Supply and providing Bus bar chamber, 100 x 40 mm aluminium anodised legend plates in the existing panel board as required.
329OD159998/2024-2025:Supply and providing Danger 415 V, 150 x 100 mm aluminium anodised legend plates in the existing panel board as required.
330OD159999/2024-2025:Painting letters or figures of the size2.50 cm, 4 cm or 5 cm with enamel paint as identification mark to SB, DB, panel board etc
331OD160000/2024-2025:Supply and providing First aid chart duly framed and placed in a conspicuous location for clear vision.
332OD160001/2024-2025:Supply and providing 9 litre capacity Galvanized mild steel Fire bucket conforming to IS 2546-1974. The bucket shall be galvanized and painted with two coats of white paint on the inside and two coats of red paint on the outside.The handles and ears shall be painted with two coats of black paint.The word 'FIRE" shall be painted in black centrally on the outside,its letters shall be 75 mm high and approximately 12 mm thick.The bucket shall be water tight.The bucket shall be fixed on MS angle frame work/ wall bracket filled with fine sand .
333OD160002/2024-2025:SITC of ABC Modular Store Pressured Pendant type 5 kgs capacity Fire Extinguisher, fabricated from EDD CR Sheet sheets fitted with brass forged sprinkler assembly incorporated with pressure guage, initial charge of 5 kgs. ABC Powder and pressurized with nitrogen gas at 14 kgf/cm2 M.S. Body as per IS: 513. Forged sprinkler head body as per IS: 319. The sprinkler body will comprise of temperature sensitive quartsoid bulb of temperature rating of 68deg;.
334OD54322/2025-2026:Supply and providing 4.5Kg CO2 fire extinguisher, filled with CO2 gas as per IS 15222, control discharge mechanism fitted with minimum 1.5 meter wire braided hose & flat horn with diffuser nozzle for dispersed discharge of CO2, discharge time 37 sec, average discharge is 95%, applicable on class B, C and electrcally started fire, external coating is of enamel spray painting, valve confirm to IS 3224 ISI marked, CO2 cylinder construction: hot spinning by seamless pipes & bearing ISI mark, body confirms to IS 7285 extinguishers to ISI marked. fire rating:89B
335OD160003/2024-2025:Supply and providing Class B (2.5 mm thick) Elastomeric insulating mat conforming to IS 15652/2006 with maximum use voltage is 11KV.
336OD160004/2024-2025:Supply and providing Class A (2mm thick )Elastomeric insulating mat conforming to IS 15652/2006 with maximum use voltage is 3.3 KV .
337OD160005/2024-2025:Charges for preparation Electrical scheme A3 size- First copy.
338OD160006/2024-2025:Copying charges for Electrical scheme A3 size additional coppy
33990.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
34014.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
34114.10:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement).
34214.11:Providing brick work (in width 225 mm or more) with F.P.S. bricks of class designation 7.5 in cement mortar 1:4 (1 cement : 4 coarse sand) at all levels.
34314.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels
344OD160007/2024-2025:Reinforcement for R.C.C works, bend tied and placed in position (plain grill requiring bend cold) using tor steel
3451.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C
3461.11:Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
34790.3.20.3:Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture
34890.3.24.3:Supply & installation of light fittings suspended on ball & socket arrangement with 19 mm down rod Supply, conveyance, installation, testing and commissioning the light fittings of following types made of .5mm thick CRCA sheet accessories and lamps etc. including supplying and fixing ball and socket arrangements on PVC round block, suspension down rod of 19mm dia MS conduit up to 2x30cm length including painting and wiring the down rod with 16/0.20mm 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connections etc. a required.1200 mm 1X20W LED Lamp with box type fixture
34990.3.10:Supplying and providing extra H.G conduit down rod of 19 mm dia 2 x 1.00 m long with 16/0.20 mm 3 core copper conductor flex wire conforming to relevant ISS or with the extended original wiring and giving connection etc. as required.
350OD187441/2025-2026:Supply ,installation, testing and commissioning of 700lm pressure die cast housing Bulk head with IP65 protection & IK 08 having efficacy not less than 105lm/W and giving connection with 3 core flex wire as required.
351OD187443/2025-2026:Supply, installation, testing and commissioning of 1200 mm sweep BEE-5 star rated ceiling fan with brushless direct current motor (BLDC) , class of insulation B , 3 no:s blades , 30 cm long down rod , 2no:s canopies, shackle kit, safety rope , copper winding, power factor not less than .9, service value (CM/M/W) minimum 6.00, Air delivery minimum 210 cum/min,350 RPM (tolerance as per IS :374-2019, THD less than 10% remote or electronic regulator unit for speed control and all remaining accesories including safety pin, nut and bolts , washers, temperature rise equal to 75 deg celsius ( maximum) , insulation resistance more than 2 Megaohm , suitable for 230V,50 Hz, single phase AC supply , earthing etc., complete as required:
352OD160011/2024-2025:Supply, conveyance installation testing and commissioning the light fittings of 1800 lumen round/ square surface mount LED fitting made of diecast aluminium, having efficacy not less than 100l/w, pf greater than 0.95, THD less than or equal to 10%, Chip make Cree/Osram/lumilled/Nichea and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.
353OD160012/2024-2025:Supply, conveyance installation testing and commissioning the light fittings of 3600 lumen square (2ft X 2ft) recessed mounting LED fitting made of crca sheet of thickness 0.5mm, having efficacy not less than 110l/w, pf greater than 0.95, THD less than or equal to 10%, Chip make Cree/Osram/lumilled/Nichea (UGR less than 19) and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.
354OD160013/2024-2025:Supply and fixing (1 Feet) 5W LED batten (Warm white ) Light fittings with required length of flexible cable and necessary connected items as required.
355OD160014/2024-2025:Supply, conveyance installation testing and commissioning the light fittings of 1800 lumen round/ square(1X1) recessed fitting made of diecastaluminium, having efficacy not less than 110l/w, pf greater than 0.95, THD less than or equal to 10%, Chip makeCree/Osram/lumilled/Nichea and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.
356OD117995/2025-2026:Supply, conveyance installation testing and commissioning the light fittings of 2400 lumen round/ square(1X1) recessed fitting made of diecast aluminium, having efficacy not less than 110l/w, pf greater than 0.95, THD less than or equal to 10%, Chip makeCree/Osram/lumilled/Nichea and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.
357OD160015/2024-2025:Supply, conveyance installation testing and commissioning of Comet Wall Light 30575 with 7W LED bulb and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required. (Make Philips or its equivalent )
358OD55343/2025-2026:Supply, conveyance installation testing and commissioning the light fittings of 3000 lumen square (2ft X 2ft) recessed mounting LED fitting made of crca sheet of thickness 0.5mm, having efficacy not less than 110l/w, pf greater than 0.95, THD less than or equal to 10%, Chip make Cree/Osram/lumilled/Nichea (UGR less than 19) and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.
359OD160016/2024-2025:Supply, conveyance installation testing and commissioning the light fittings of 1500 lumen round/ square(1X1) recessed fitting made of diecast aluminium, having efficacy not less than 110l/w, pf greater than 0.95, THD less than or equal to 10%, Chip makeCree/Osram/lumilled/Nichea and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.
360OD160018/2024-2025:supply and fixing of Rope light with IP 65 rating to withstand harsh outdoor conditions, 7 W/m operating wattage, Lumen output – 480 lumens per meter, 60 LEDs/meter for uniform light output, BIS Safety Standards Registered with Surge, Protection up to 2.5 kV, Power Factor > 0.9 as required. Make Crompton New Galaxy 2835 Ip65 Led Rope Light or its equivalent
36190.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
362OD118210/2025-2026:Supply of safety Bowden with double side end lock as required
3631.48:Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
36490.5.1.3:Supply and fixing the following types of superior quality 250V A.C call bell on existing M.S. box and giving connections with required length of 3 core, 16 / 0.20mm 650/1100V grade PVC insulated and PVC sheathed round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, earthing the MS box and making good the surface as required.Ding dong bell
36590.5.1.4:Supply and fixing the following types of superior quality 250V A.C call bell on existing M.S. box and giving connections with required length of 3 core, 16 / 0.20mm 650/1100V grade PVC insulated and PVC sheathed round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, earthing the MS box and making good the surface as required.Musical bell with bird sound
36690.5.1.5:Supply and fixing the following types of superior quality 250V A.C call bell on existing M.S. box and giving connections with required length of 3 core, 16 / 0.20mm 650/1100V grade PVC insulated and PVC sheathed round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, earthing the MS box and making good the surface as required.DC operated remote controlled electric bell
367OD160019/2024-2025:Supply, installation, testing and commissioning of 450mm wall fan with metal body in working on 230 V A/C fittings with all accessories l and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required (Make Havells V3F or its equivalent)
36890.4.8:Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required.
36990.4.9:Charges for cutting holes suitable for accommodating exhaust fans above 305mm sweep and up to 450mm sweep including plastering colour washing etc. as required.
370OD118184/2025-2026:Supply, installation, testing and commissioning of 150 mm sweep Light Duty Exhaust fan in plastic body with self opening lowers working on 230v single phase A/C supply, fittings with all accessories l and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required.
371OD160020/2024-2025:Supply, installation, testing and commissioning of 300/305 mm sweep Light Duty Exhaust fan in metal frame working on 230 V A/C fittings with all accessories l and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required
372OD159988/2024-2025:Supply, installation, testing and commissioning of 200/225 mm sweep Light Duty Exhaust fan in metal frame working on 230 V A/C fittings with all accessories l and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required
373OD160021/2024-2025:Supply, installation, testing and commissioning of 380 mm sweep, 900 rpm Heavy Duty Exhaust fan in metal frame working on 230 V A/C fittings with all accessories l and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required.
374OD187792/2025-2026:Supply and providing Low intensity Integral LED aviation obstruction light with yellow painted die-cast aluminium alloy housing, red coloured polycarbonate enclosure, peak intensity at night min. 32 cd/sq. meter
375OD289314/2025-2026:Supply ,installation, testing and commissioning of 5 metre hot dip galvanised Octogonal pole in single section with average galvanization 65 microns or above having minimum 70mm top diameter& 130mm bottom diameter with sheet having thickness 3mm( min),base plate dimensions of 200x200x12mm (min) . The Octagonal Poles should withstand the wind speed upto a min 39m/s as per IS 875 Part 3 with single arm bracket 0.5m length .The pole should have inbuilt vandal resistant weather proof door mounting 500 mm above from ground with proper gaskets & alen key arrangement for safety locking.The Octagonal Poles shall be bolted on a foundation with a set of minimun four foundation bolts made from special steel galvanized along with nuts washers etc company make same as that of pole .
376OD289332/2025-2026:Supply ,installation, testing and commissioning of 5 metre hot dip galvanised Octogonal pole in single section with average galvanization 65 microns or above having minimum 70mm top diameter& 130mm bottom diameter with sheet having thickness 3mm( min),base plate dimensions of 200x200x12mm (min) . The Octagonal Poles should withstand the wind speed upto a min 39m/s as per IS 875 Part 3 with double bracket 0.5m length .The pole should have inbuilt vandal resistant weather proof door mounting 500 mm above from ground with proper gaskets & alen key arrangement for safety locking.The Octagonal Poles shall be bolted on a foundation with a set of minimun four foundation bolts made from special steel galvanized along with nuts washers etc company make same as that of pole .
377OD289327/2025-2026:Supply ,installation,testing and commissioning of 8400 lumen LED, efficacy >=120 Lm/watt, IP 66 street light fitting with die-cast aluminium housing, polycarbonate cover complete with THD <10%, power factor >0.95, RoHS compliant, duly wired up for use on 230 V AC supply, IK >=7, with internal surge protection 4k above. Chip make Cree/Osram/lumilled/Nichea/Bridgelux.(LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
378OD289289/2025-2026:Supply ,installation,testing and commissioning of 10800 lumen LED, efficacy >=120 Lm/watt, IP 66 street light fitting with die-cast aluminium housing, polycarbonate cover complete with THD <10%, power factor >0.95, RoHS compliant, duly wired up for use on 230 V AC supply, IK >=7, with internal surge protection 4k above. Chip make Cree/Osram/lumilled/Nichea/Bridgelux.(LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
37990.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
380OD160009/2024-2025:Supply and fixing of SMC type Junction box for the size of ( H 295 X W 255 X D 120) Hinged type to the existing Lamp pole with necessary connected items as required. ( Make Sintex code. GSJB 2520 or its equivalent)
381OD259044/2025-2026:Providing and drawing 2.00 mm (14 SWG) copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
382OD259048/2025-2026:Providing and drawing 2.65 mm(12 SWG) copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
383OD259054/2025-2026:Providing and drawing 3.15 mm (10 SWG) copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
384OD259112/2025-2026:Providing and drawing 4.00 mm (8 SWG) copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
38590.16.5.1:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.00 mm (14 SWG)
38690.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
38790.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
38890.16.5.4:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG)
3891.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
3901.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
3911.21.3:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
39290.9.1.1:Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.50x50mm Cable Management System with base and lid
39390.9.1.2:Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.External angle 90 degree
39490.9.1.3:Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Flat angle 90 Degree /Tee
39590.9.1.4:Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Internal angle 90 degree
39690.9.1.6:Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Flat Cross
39790.9.1.7:Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.End cap
39890.9.2.1:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.100 x 50 mm CMS with base and lid
39990.9.2.2:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Cable devider
40090.9.2.3:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.External angle 90 degree
40190.9.2.4:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Flat angle 90 degree
40290.9.2.5:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Internal angle 90 degree
40390.9.2.7:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Flat cross
40490.9.2.8:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.End cap
40590.9.2.12:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.1 to 3 module mounting box
406OD194069/2025-2026:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required. 6 module mounting box
40790.10.1.2:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )2 module moulded plastic box on surface
40890.10.1.5:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )6 module moulded plastic box on surface
40990.9.2.14:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.8 module mounting box
4101.28.1:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module
4111.28.2:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module
4121.28.4:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module
4131.28.5:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.8 Module
41490.10.3.14:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A SP switch with indicator
4151.17.1:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.1 x 1.5 sq. mm
4161.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
4171.17.6:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm
4181.17.9:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.9 x 1.5 sq. mm
4191.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
4201.17.15:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 2.5 sq. mm
4211.17.18:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.9 x 2.5 sq. mm
4221.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
4231.17.24:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 4 sq. mm
4241.17.30:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. mm
4251.17.33:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 6 sq. mm
42690.6.4.53:Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.10.00 sq.mm 3 Run
42790.6.4.56:Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.10.00 sq.mm 6 Run
4281.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
4291.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
4301.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
4311.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
4321.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
4331.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
4341.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
4351.27.5:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)
43690.10.3.33:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket
437OD149157/2025-2026:Supply, fixing & giving connection of 250A 8 way MCCB Load Bank Sub Main Distribution Board (SMDB) with IP43 protection complying to lEC 61439-2 with copper bus neutral link earth bus, Short-time withstand current 36kA 1s double door facility, 2 nos side cable entry box, bottom cable entry box, meter box, 4 nos corner box , etc suitable for providing 4 pole incoming and 3 pole outgoing fixed on wall using necessary anchor bolts including cutting hole on the wall , making good the damages, colour washing etc. as required as required. MCCB Load Bank, 250A BUS 8way outgoings L&K Enersys (Category DA62D1084CZZ0) or equivalent.
438OD187445/2025-2026:Supply and installation of C R C A sheet steel, minimum thickness 1mm phosphatised and powder coated, dust and vermin proof DP enclosure on surface/recess for independent mounting of MCB/RCCB/ISOLATOR .
439OD160023/2024-2025:Supplying and fixing FP sheet steel enclosure on surface/ recess along with 16/25/32amps 415 volts 40A 4 pole Isolator complete with connections, testing and commissioning etc. as required.
440OD160024/2024-2025:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator 4 way, Double door
4412.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)8 way, Double door
4422.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)12 way, Double door
4432.3.4:Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)16 way, Double door
44490.11.1.14:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
44590.11.1.15:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
44690.11.1.10:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43)
44790.11.1.11:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43)
4482.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole
4492.10.4:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Triple pole
450OD194600/2025-2026:Supplying and fixing 40 to 63 amps rating, 415 volts,3 pole \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole
4512.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
4522.12.2:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
4532.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
4542.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
4552.14.1:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
4562.14.2:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
4572.15.1:Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.25 amps
4582.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.40 amps
4592.15.3:Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.63 amps
4602.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
461OD160029/2024-2025:Providing ridges or hips of width 60 cm overall width plain G.S. sheetfixed with polymer coated J or Lhooks, bolts and nuts 8 mm dia G.I.limpet and bitumen washers complete.0.63 mm thick with zinc coating not less than 275 gm/m
462OD160032/2024-2025:Supply and providing 80mm diameter medium class GI pipe
4634.1.2:Supplying and installing following size of perforated painted with powder coatingM.S. cable trays with perforation not more than 17.5%, in convenient sections,joined with connectors, suspended from the ceiling with M.S. suspendersincluding bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness
4644.1.4:Supplying and installing following size of perforated painted with powder coatingM.S. cable trays with perforation not more than 17.5%, in convenient sections,joined with connectors, suspended from the ceiling with M.S. suspendersincluding bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness
4654.1.14:Supplying and installing following size of perforated painted with powder coatingM.S. cable trays with perforation not more than 17.5%, in convenient sections,joined with connectors, suspended from the ceiling with M.S. suspendersincluding bolts & nuts, painting suspenders etc as required.600 mm width X 75 mm depth X 2.0 mm thickness
4664.1.15:Supplying and installing following size of perforated painted with powder coatingM.S. cable trays with perforation not more than 17.5%, in convenient sections,joined with connectors, suspended from the ceiling with M.S. suspendersincluding bolts & nuts, painting suspenders etc as required.750 mm width X 75 mm depth X 2.0 mm thickness
4674.2.2:Supplying and installing following size of perforated pre-painted M.S. cable trays bends withperforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness
4684.2.4:Supplying and installing following size of perforated pre-painted M.S. cable trays bends withperforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness
4694.2.14:Supplying and installing following size of perforated pre-painted M.S. cable trays bends withperforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.600 mm width X 75 mm depth X 2.0 mm thickness
4704.2.15:Supplying and installing following size of perforated pre-painted M.S. cable trays bends withperforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.750 mm width X 75 mm depth X 2.0 mm thickness
4714.3.2:Supplying and installing following size of perforated painted with powder coatingM.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspendersincluding bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness
4724.3.4:Supplying and installing following size of perforated painted with powder coatingM.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspendersincluding bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness
4734.3.14:Supplying and installing following size of perforated painted with powder coatingM.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspendersincluding bolts & nuts, painting suspenders etc as required.600 mm width X 75 mm depth X 2.0 mm thickness
4744.3.15:Supplying and installing following size of perforated painted with powder coatingM.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspendersincluding bolts & nuts, painting suspenders etc as required.750 mm width X 75 mm depth X 2.0 mm thickness
4754.4.14:Supplying and installing following size of perforated painted with powder coatingM.S. cable trays Cross Member with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts &nuts, painting suspenders etc as required.600 mm width X 75 mm depth X 2.0 mm thickness
4764.4.15:Supplying and installing following size of perforated painted with powder coatingM.S. cable trays Cross Member with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts &nuts, painting suspenders etc as required.750 mm width X 75 mm depth X 2.0 mm thickness
477OD187632/2025-2026:Supply, installation, testing and commissioning of True online, Double Conversion 1 KVA, UPS having 60 minutes backup with suitable size of c10 tubular batteries & rack having the following specifications. a) 1 ph to 1 ph b) Input pf : 0.99 @ full load c) Output pf : unity d) Input voltage range : 140V -280V with cut off e) THD :=87% g) Ambient Temperature : 0-40°C h) Generator Compatibility. i) Pure sine wave. j) Battery over charge & under charge cut off. k) Bypass arrangement. l) Isolation transformer l) EN/IEC 620401 for General Safety compatibility m) EN/IEC 620402 for Electromagnetic Compatibility. n) EN/IEC 620403 for Performance o) EN/IEC 620404 for Environmental Compatibility p) battery : exide / panasonic or equivalent.
478OD187644/2025-2026:Supply, installation, testing and commissioning of True online, Double Conversion 3KVA UPS having 60 minutes backup with suitable size of c10 tubular batteries & rack having the following specifications. "a) 1 ph to 1 ph b) Input pf : 0.99 @ full load c) Output pf : unity d) Input voltage range : 140V -280V with cut off e) THD : <= 10% f) Overall Efficiency : >=87% g) Ambient Temperature : 0-40°C h) Generator Compatibility. i) Pure sine wave. j) Battery over charge & under charge cut off. l) Bypass arrangement. m) EN/IEC 620401 for General Safety compatibility n) EN/IEC 620402 for Electromagnetic Compatibility. o) EN/IEC 620403 for Performance p) EN/IEC 620404 for Environmental Compatibility q) battery : Exide / Panasonic or equivalent "
479OD187633/2025-2026:Supply, installation, testing and commissioning of True online, Double Conversion 6 KVA, UPS having 60 minutes backup with suitable size of c10 tubular batteries & rack having the following specifications. a) 1 ph to 1 ph b) Input pf : 0.99 @ full load c) Output pf : unity d) Input voltage range : 140V -280V with cut off e) THD : ≤ 10% f) Overall Efficiency : ≥87% g) Ambient Temperature : 0-40°C h) Generator Compatibility. i) Pure sine wave. j) Battery over charge & under charge cut off. k) Bypass arrangement. l) Isolation transformer l) EN/IEC 620401 for General Safety compatibility m) EN/IEC 620402 for Electromagnetic Compatibility. n) EN/IEC 620403 for Performance o) EN/IEC 620404 for Environmental Compatibility p) battery : exide / panasonic or equivalent.
480OD187721/2025-2026:Supply, installation, testing and commissioning of True online, Double Conversion 10 KVA, UPS having 60 minutes backup with suitable size of c10 tubular batteries & rack having the following specifications. \\"a) 3 ph to 1 ph b) Input pf : 0.99 @ full loadc) Output pf : 0.95 d) Input voltage range : 305V -485V with cut off e) THDi <= 5% f) Overall Efficiency : 94%g) Ambient Temperature : 0-40°C h) Generator Compatibility. i) Pure sine wave j) Battery over charge & under charge cut off l) Bypass arrangement. m) EN/IEC 620401 for General Safety compatibility n) EN/IEC 620402 for Electromagnetic Compatibility. o) EN/IEC 620403 for Performance p) EN/IEC 620404 for Environmental Compatibility q) battery : exide / panasonic or equivalent \\"
481OD187790/2025-2026:Supply,installation,testing and commissioning of 5 kg Clean agent fire Extinguisher Modular type of following sizes suitable for below ceiling built in 1 piece with body and bottom. Mild steel body with pressure gauge refillable device and safety release device, Brass valve suitable for B and C classes of fire complete with charge of HFC 236FA/FE36(it is a blend of Hydro Fluoro carbon and organic detossificant essence P 26). The extinguisher shall have pressure gauge for indication inside pressure with heat sensitive glass bulb 68 degree with brass forged nozzle and sheet thickness shall not less than 2mm
482OD194206/2025-2026:Supply and clamping 20mm sizes of corrugated pvc flexible conduit with necessary compression gland with locking ring and check nut at termination pointed using suitable size GI/ pointed MS saddles spacing not exeeding 60 cms on surface including making good the damages, color washing etc as rerquired.
483OD194208/2025-2026:Supply and providing 6mm thick MS chequered plate cut to shape and place in position excluding frame work if required
484OD54367/2025-2026:Supply and fixing of 8mm Aluminium round conductor complete as specified in drawing & Meets the requirements of din EN 50164-2 ( VDE 0185 part 202) & VDE 0185-305 (IS / IEC 62305 ,the conductor fixing horizontally on the FLAT CONCRETE ROOF SLAB / parapet of the building on the existing holder as required.
485OD54348/2025-2026:Supply and fixing of 8mm Aluminium round conductor complete as specified in drawing &amp; Meets the requirements of din EN 50164-2 ( VDE 0185 part 202) &amp; VDE 0185-305 (IS / IEC 62305 ,the conductor fixing vertically on the wall/ceiling of the building on the existing holder as required (make OBO or its equivalent)
486OD54353/2025-2026:supply and fixing of Polyamide roof cable holder for flat roof: DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black @ 1 meter distances as required.
487OD54354/2025-2026:Supply and fixing of Stand for Fang Fix system 16 kg with base and clamp ,made up of frost resistant concrete as required.
488OD54355/2025-2026:Supply and fixing of Vertical air terminal with accessories:Providing of Air terminals as per IS-IEC -62305 part-3 Nominal size Ø10/16 mm aluminium rod: 2Mtr Air terminal: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load tested as per IEC 62561(1-8) as required.
489OD54356/2025-2026:Supply and fixing of Vertical air terminal with accessories:Providing of Air terminals as per IS-IEC -62305 part-3 Nominal size Ø10/16 mm aluminium rod: 4Mtr Air terminal: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load tested as per IEC 62561(1-8) as required.
490OD54357/2025-2026:Supply and fixing of Stand for Fang Fix system 16 kg with base and clamp ,made up of frost resistant concrete and tested upto 100KA lightning current. Tested as per IEC 62561(1-8) as required.
491OD54358/2025-2026:Supply, conveyance and fixing of Cross universal connector for T and cross connection, to route vertical down conductor/mesh formation made of hot dipped galvanized iron with necessary screws etc as required. installed with 4 hexagonal bolt M8*25 with M8 hexagonal bolt & nut etc and fixing the conductor properly as required.
492OD54359/2025-2026:Supply and fixing of expansion piece with connector. For equalizing temperature related length changes. Necessary on conductors length over 20 meters. For round conductor Rd 8/ALU.
493OD54360/2025-2026:Supply and fixing Connector: For T cross and parallel connectors Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanized. Conforms to the requirements according to DINVDE 0185-305 (IS-IEC 62305)(2nos/expansion piece) as required.
494OD54361/2025-2026:Supply and fixing of Test Joint suitable to connect 8mm round conductor and max by 30x3 mm GI strip as required.
495OD54362/2025-2026:Supply and fixing of Galvanized Steel Flat 30 mm X 3 mm thickness from earth electrode directly in\ ground as required. Flat conductor shall be of hot dipped & cross sectional area of 90mm square. According to DIN EN 50164-2(VDE 0185 part 202) Meets the requirements of VDE0185/305 ( IS- IEC 62305 ) Zinc coating 500g/m square should be tested and used exclusively for lightning protection earthing system and ring equipotential bonding etc as required.
496OD54363/2025-2026:Supply and providing of Cross connector for Flat suitable for 30 mm Galvanised steel strip.installed with 4 nos of hexagonal plate.
497OD54364/2025-2026:Supply and providing of flat conductor holder suitable for FL 30. Installed with 2 hexagonal bolts etc as required.
498OD54365/2025-2026:Supply and providing of Plastic Corrosion Protection strip: Approx. 1.1 mm thick. Width 50mm. and 10 meter length Made of petrolatum-coated chemical fibre fabric as required.
499OD54366/2025-2026:Supply and fixing of Roof conductor holder for parapet -polyimide conductor holder. with M8 female thread or diameter 7mm, M8 screw to connect the conductor holder. Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance as required.
500OD54369/2025-2026:Supply installation testing and commission of CHEMICAL EARTHING system , of UL Listed & CPRI Tested maintenance free, Low carbon copper coated earth rod of 3 meter electrode having diameter of 17.2 mm with copper coating thickness of 250micron tested as per IEC 62561-2 is provided with universal clamp made of SS to connect rod with flat conductor including excavation soil. Earth conductivity enhancing compound shall be of 25kg/pit tested as per IEC 62561-7, TCLP tested. The above arrangements shall be provided with heavy duty earth chamber of 5000kg load Bering capacity to ensure the safety of earthing system as required
501SITC of LIFT(Electrical work)
502OD16552/2025-2026:Supply, Installation, Testing and Commissioning of 13 passenger Lift machine room less type gearless with the following specification including all required standard features.1. Type of Lift: 13 Passenger capacity, Gearless (Machine room less type)2. Load / Persons : 884Kg. / 13 persons3 .Rated speed : 1.5 m/Sec.4. Travel: 36 Mtr (Approx) 5. No. of floor and entrance served: 11 stops and 11 openings (B1+B2+B3+G+7)6. No. of floor served : 11-Floors 7. Method of control : Microprocessor based V3F with ARD system.8. Location of machine room: above lift well9. Size of lift well :2050 mm W X 2400 mm D10. Car entrance: As per IS11. Leveling accuracy : As per IS12. Car door opening : As per IS13. Drive : Variable voltage variable frequency(V3F)14.Operation : Simplex full selective collective control with ON/OFF switch15.Construction of design and furnishing of car body work:Vandal proof Stainlesssteel (SS304, make:Tata/Jindal) finish cabinet with Scratch proof Stainless steel door(sheet 1mm thickness), Stainless steel mirror finish ceiling, Aluminium 3 mm minimum thicknessanti skid flooring, fan with timer cut-off, push to talk, LED display, LED light, handrails and floor announcement system. All buttons in the car and all landings shouldhave Braille signs.16. Landing entrance : Automatic centre/Telescopic opening Vandal proof stainlesssteel sliding door as per IS with provision for mechanical opening key for emergencywith full length infrared light curtains and half framed fire rated glass door forminimum 2 Hrs.17. Call and position indicators : Up/down direction & position Dot Matrix LEDindication shall be provided at all landings18. Electric supply : 1) Light 230V/50 Hz single phase 2 wire system. 2) 415V 50Hz3 phase 4 wire system.19. Infrared door opening system: To be provided for entire length of the door20. Automatic Rescue Device :Provide automatic rescue device with an electroniccontroller powered by maintenance free batteries with capacity for minimum fourrescue operations. The rescue operation should act within 10 seconds of power failure21. Regulation :350V-450V (SMPS based)22. Indication in the car : a) Car position b) Call indicator c) Door close/open pushbutton d) Emergency stop button e) Push button for fan and light f) Non stop buttong) Battery operated emergency lamp with rechargeable batteries. h) Battery operatedalarm bell i) Intercom wiring with one master unit with two slaves j) Fireman'sswitch at main lobby i) Auto attendant control (inside the car)23. Winding handle: Manual winding handle for use in emergency.24. Safeties a) Over speed governor, operated safety gear b) Buffers c) Motoroverload protection d) Phase reversal protection e) Other safeties as per IS f) Singlephase preventer g) Final limit switch25. Leveling: Automatic leveling at all landing as per IS26. Guarantee: Company shall carry out free maintenance during warranty period of36 months which also includes a) Cleaning lift equipment b) Lubrication of allmoving parts c) Replacing of lubricating oil when required d) Checking and adjustingcontacts e) Replacing fusible item alarm etc. f) Recharging batteries in case of drain/renewing batteries g) Replacing /rewinding of all defective parts of the lift includingmotors and V3F unit.27. Control panel: Control panel will be dust and vermin proof of sheet metalenclosure28. Announcement System: To provide lift announcement system29. Tests: At site test as per IS to be carried out and approval from ElectricalInspectorate before Handing over.30. Scope of work:- a) Supply of lift materials b) Minor civil works such as removal of temporary brick work in the lift entrance without affecting the building structure, finishing/ altering civil works in lift entrance/ pit by providing brickwork & plastering if necessary including minor civil works such as construction of buffer block in the pit machine foundation in the machine room, cutting pockets and grounding brackets for the guide rails, grouting boxes for control units, correction of wall opening in the front side of the wall by additional brickwork or cutting existing brick work including core cutting of machine room and waterproofing in lift pit c) Scaffolding d) Door frames e) Supporting steel f) Temporary electric supply for installation of lift. Electric supply for testing and commissioning of lift is to be arranged by the firm on their own account. g) Intercom facilities with one master and two slaves h) Battery operated alarm i) Obtaining Scheme approval as well as energization Certificate from the electrical Inspectorate including preparation of necessary drawing for the same. Necessary fee shall be remitted to the Inspectorate by the firm for which no refund will be made from the department including taking insurance for one year as per new lift rule. j) Supply of booklet with complete details of maintenance schedule and control diagram. k) Giving training to department staff for attending troubleshooting l) Guarantee: Company shall carry out free maintenance and service during entire DLP period which also includes a) Cleaning lift equipment b) Lubrication of all moving parts c) Replacing of lubricating oil when required d) Checking and adjusting contacts e) Replacing fusible item alarm etc. f) Recharging batteries in case of drain/ renewing batteries g ) Replacing /rewinding of all defective parts of the lift including motors and V3F unit.
503Fire fighting work(Electrical work)
50418.1.4:a)Supplying,installation,testing and commissioning of Electric driven Main Fire Pump suitable for Automatic operation and consisting of following, complete in all respect , as required :b) Horizontal type, Multi stage ,centrifugal, split casing Pump of Cast Iron body and bronze impeller with stainless steel shaft ,mechanical seal conforming to IS 1520. C) Suitable HP Squirrel Cage Induction Motor, TEFC, Synchronous speed 1500rpm suitable for operation on 415 V 3 phase 50 HZ AC supply with IP55 Protection for enclosure ,horizontal foot mounted type with class F insulation, conforming to IS 325.d) M.S Fabricated common base plate coupling, coupling guard ,foundation bolts etc as required.e) Suitable cement concrete foundation duly plastered with Anti vibration pads2280 lpm at 88 m head
50518.3.1:a)Supplying, installation, testing and commissioning of Electric driven Pressurisation Pump suitable for Automatic operation and consisting of following, complete in all respect , as required :(Jockey Pump)b) Horizontal type, Multi stage ,centrifugal, split casing Pump of Cast Iron body and bronze impeller with stainless steel shaft ,mechanical seal conforming to IS 1520. C) Suitable HP Squirrel Cage Induction Motor, TEFC type suitable for operation on 415 V 3 phase 50 HZ AC supply with IP55 Protection for enclosure ,horizontal foot mounted type with class F insulation, conforming to IS 325. d)M.S Fabricated common base plate coupling, coupling guard ,foundation bolts etc as required.e) Suitable cement concrete foundation duly plastered with Anti vibration pads180 lpm at 88m head
50618.2.4:a)Supplying,installation,testing and commissioning of Diesel Engine driven Main Fire Pump suitable for Automatic operation and consisting of following, complete in all respect , as required :(Diesel Driven Pump)b) Horizontal type, Multi stage ,centrifugal, split Pump of Cast Iron body and bronze impeller with stainless steel shaft ,mechanical seal conforming to IS 1520. C) Suitable HP ,1500rpm,water cooled with radiator,diesel engine conforming to relevant IS standard complete with auto starting mechanism 12/24 V Electric starting equipment,diesel tank, exhaust pipe extended upto 10m outside pump house duly insulated with 50 mm thick glass wool with 1 mm thick Al sheet cladding residential silencer, instruments and protection as per standard specifications, stop solenoid for Auto stop in the event of fault with audio indications, painted with post office red colour etc as required.d) M.S Fabricated common base plate coupling, coupling guard ,foundation bolts etc as required.e) Suitable cement concrete foundation duly plastered with Anti vibration pads2280 lpm at 88m head
507OD187677/2025-2026:Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required : Incomings 250A, 50kA 4 Pole MCCB, Ics=100% Icu Rating Digital Voltmeter 0-500V with selector switch Ammeter (0-800 A) with selector swtich & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 500Amps. Outgoings ( Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps) Main Fire Pump 125 Amp, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 60 hp pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. - 2 sets. JOCKEY PUMP 63 Amp, 50kA TPN MCCB, Ics=100% Icu, with Suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. - 2 sets. DIESEL ENGINE CONTROL Control for diesel engine comprising -Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0-20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System Controller Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification
508OD260480/2025-2026:Supply ,laying and fixing of one number PVC insulated and PVC sheathed / XLPE Aluminium conductor armoured power cable of 1.1 KV grade conforming to IS 1554/(part I)/1988 for PVC & IS 7098/(part I )/1988 for XLPE of following size on wall surface as required 3x16 sqmm (clamped with 1mm thick saddle)
509OD260481/2025-2026:Supply ,laying and fixing of one number PVC insulated and PVC sheathed / XLPE Aluminium conductor power cable of 1.1 KV grade conforming to IS 1554/(part I)/1988 for PVC & IS 7098/(part I)/1988 for XLPE of following size on wall surface as required. 3.5x95 sqmm (clamped with 25x3mm MS flat clamp)
510OD260487/2025-2026:Supply ,laying and fixing of one number PVC insulated and PVC sheathed / XLPE Aluminium conductor power cable of 1.1 KV grade conforming to IS 1554/(part I)/1988 for PVC & IS 7098/(part I)/1988 for XLPE of following size on wall surface as required. 3.5x240 sqmm (clamped with 40x3mm MS flat clamp)
511OD289743/2025-2026:Providing, laying, testing and commissioning of C class heavy duty GI Pipe conforming to IS 1239 i/c fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., in ground including welding ,excavation and providing cement concrete blocks as supports, Anti corrosive treatment with coal tar ,Asphalt type as per IS 10221, refiiling the trench etc., of following sizes150 mm dia
51218.8.3:Providing, laying, testing and commissioning of C class heavy duty GI pipe conforming to IS 1239, i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required.40mm
51318.8.4:Providing, laying, testing and commissioning of C class heavy duty GI pipe conforming to IS 1239, i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required.50mm
51418.8.5:Providing, laying, testing and commissioning of C class heavy duty GI pipe conforming to IS 1239, i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required.65mm
51518.8.6:Providing, laying, testing and commissioning of C class heavy duty GI pipe conforming to IS 1239, i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required.80 mm
51618.8.7:Providing, laying, testing and commissioning of C class heavy duty GI pipe conforming to IS 1239, i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required.100 mm
51718.8.8:Providing, laying, testing and commissioning of C class heavy duty GI pipe conforming to IS 1239, i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required.150 mm
51818.8.1:Providing, laying, testing and commissioning of C class heavy duty GI pipe conforming to IS 1239, i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required.25mm
51918.8.2:Providing, laying, testing and commissioning of C class heavy duty GI pipe conforming to IS 1239, i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required.32mm
52018.15.4:Providing, installation ,testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel , Grade 304,sheet with3 mm dia holes with stainless steel flange.200 mm dia
52118.11.2:Supplying, fixing, testing and commissioning of Butterfly Valve of PN 1.6 rating with bronze or gun metal seat duly ISI marked complete with nuts, bolts ,washers ,gaskets conforming to IS 13095 of following sizes as required:50 mm dia
52218.11.3:Supplying, fixing, testing and commissioning of Butterfly Valve of PN 1.6 rating with bronze or gun metal seat duly ISI marked complete with nuts, bolts ,washers ,gaskets conforming to IS 13095 of following sizes as required:65 mm dia
52318.11.4:Supplying, fixing, testing and commissioning of Butterfly Valve of PN 1.6 rating with bronze or gun metal seat duly ISI marked complete with nuts, bolts ,washers ,gaskets conforming to IS 13095 of following sizes as required:80 mm dia
52418.11.5:Supplying, fixing, testing and commissioning of Butterfly Valve of PN 1.6 rating with bronze or gun metal seat duly ISI marked complete with nuts, bolts ,washers ,gaskets conforming to IS 13095 of following sizes as required:100 mm dia
52518.11.6:Supplying, fixing, testing and commissioning of Butterfly Valve of PN 1.6 rating with bronze or gun metal seat duly ISI marked complete with nuts, bolts ,washers ,gaskets conforming to IS 13095 of following sizes as required:150 mm dia
52618.11.7:Supplying, fixing, testing and commissioning of Butterfly Valve of PN 1.6 rating with bronze or gun metal seat duly ISI marked complete with nuts, bolts ,washers ,gaskets conforming to IS 13095 of following sizes as required:200 mm dia
52718.14.4:Providing,installation,testing and commissioning of non-return valve of following sizes conforming to IS :5312 complete with rubber gasket, GI bolts , nuts, washers etc as required.80mm dia
52818.14.5:Providing,installation,testing and commissioning of non-return valve of following sizes conforming to IS :5312 complete with rubber gasket, GI bolts , nuts, washers etc as required.100 mm dia
52918.14.7:Providing,installation,testing and commissioning of non-return valve of following sizes conforming to IS :5312 complete with rubber gasket, GI bolts , nuts, washers etc as required.150mm Dia
53018.23.1:Providing and fixing of flow switch in MS pipe including connection etc as required:100 mm dia
531OD187675/2025-2026:AIR RELEASE VALVE:- Supply Installation ,Testing and Commissioning of Air release valve 20 mm gun metal
53218.9.1:Supplying and fixing single headed internal hydrant valve with instantaneous Gun metal or stainless steel coupling of 63mm dia with cast iron wheel ISI marked conforming to IS 5290(Type A) with blank Gun metal or Stainless steel cap and chain as required:Single headed Gunmetal
533OD148994/2025-2026:Supply and fixing of weather proof hose cabinet double with PCC support made of 16Gauge MS sheet with full front glass door and locking arrangements suitable to accommodate 2 No 15 m long RLL hose pipe and 1No branch pipe.The cabinet shall be painted to scarlet red colour outside & offwhite inside.
53418.17.1:Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.a) 20 mm nominal Internal dia water hose thermoplastic(Textile reinforced) type-2 as per IS:12585b) 20 mm nominal internal dia gun metal globe valve &nozzlec) Drum and brackets for fixing the equipments on wall.d) Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.30 m
53518.16.1:Supplying and fixing 63 m dia,15m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required: Gun Metal
53618.18.2:Supplying and fixing 63 mm dia gun etal short metal branch pipe ith 20 mm nominal interanal diameter size nozzle conforming to IS 903 suitable for Instantaneous connection to Interconnect hose pipe coupling as required:Stainless steel (Grade 304)
53718.20:supplying and fixing air vessel made of 250 mm dia 8 mm thick MS sheet , 1200 mm in height with Air release valve on top and flanged connection to riser , drain arrangement with 25 mm dia Gun metal wheel valve with required accessories , pressure guage and painting with synthetic enamel paint of approved shade as required.
53818.22:Providing and fixing of pressure switch in MS pipeline including connection etc as required:
53916.8:Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required
54018.19.3:Supplying and fixing fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia M.S. Pipe connection conforming to IS 904 as required:3 way-150 mm dia M.S.Pipe
54118.21.1:Providing,fixing, testing and commissioning of 15 mm dia quatzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :Pendent Sprinkler
542OD107707/2025-2026:Supply and providing 4.5Kg CO2 fire extinguisher, filled with CO2 gas as per IS 15222, control discharge mechanism fitted with minimum 1.5 meter wire braided hose & flat horn with diffuser nozzle for dispersed discharge of CO2, discharge time 37 sec, average discharge is 95%, applicable on class B, C and electrcally started fire, external coating is of enamel spray painting, valve confirm to IS 3224 ISI marked, CO2 cylinder construction: hot spinning by seamless pipes & bearing ISI mark, body confirms to IS 7285 extinguishers to ISI marked. fire rating:89B
543OD107708/2025-2026:SITC of ABC Modular Store Pressured Pendant type 5 kgs capacity Fire Extinguisher, fabricated from EDD CR Sheet sheets fitted with brass forged sprinkler assembly incorporated with pressure guage, initial charge of 5 kgs. ABC Powder and pressurized with nitrogen gas at 14 kgf/cm2 M.S. Body as per IS: 513. Forged sprinkler head body as per IS: 319. The sprinkler body will comprise of temperature sensitive quartsoid bulb of temperature rating of 68deg;.
54417.1.1:FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL)Supplying, installation, testing & commissioning of heat detector operating at 54ºC / 57ºC with rate of rise cum fixed temperature (dual thermistor) type with mounting base complete with all connection etc. as required.
54517.1.11:FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL)Supplying, installation, testing & commissioning of main control and indicating panel made out of 16 SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections, interconnections etc complete as required.
54617.1.2:FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL)Supplying, installation, testing & commissioning of smoke detector with built-in LED and mounting base complete with all connections etc. as required.
54717.1.3:FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL)Supplying, installation, testing & commissioning of manual call boxes of MS Construction in surface/recess with stainless steel chain & hammer assembly Complete with glass and push button etc. as required.
54817.1.6:FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL)Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required.
54917.1.8:FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL)Supplying, installation, testing & commissioning talk back slave station in surface/ recess suitable for operation on simplex mode complete with P.T.T. knob & speaker/ microphone enclosed in a M.S.(16 SWG)/ ABS box with break glass in front etc. complete as required.
55017.1.9.3:Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required.10 Zone
551OD149036/2025-2026:Supplying, installation, testing & commissioning of main control and indicating panel made out of 16 SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections, interconnections etc complete as required. 10 Zone panel for fire alarm system 250 Watt amplifier racks suitable for operation on 230V AC/24V DC supply conforming to IEC-268-3 complete with all accessories as required - 2 Nos.(one to act as standby) Talk back master station with LED PTT (press to talk) push button for operation on 230V AC/24 V DC supply conforming to IEC-268 for simplex mode of operation/communication suitable for 20 Nos.talk back unit -1 set. Annoucement control desk suitable for selection of different zones selectively and ON ALL CALL switch with visual indication etc. complete as required -1 set. Amplifier change over switch for inter changing amplifier -1 No. Monitor panel for loudspeaker complete with output selector, ON/OFF switch, fuse, visual indications etc. complete as required- 1 No. Gooseneck microphone with stand and ON/OFF switch- 1 No. Main ON/OFF switch, fuse indication lamps, DC and AC voltmeters & ammeters, terminal blocks etc. complete as required -1 set. Battery charger trickle cum boost to take complete load of fire alarm & PA system complete with all accessories including providing & fixing of 2 nos.12 volt, 60 AH each sealed maintenance free batteries -1 set.
55217.3.3:PUBLIC ADDRESS SYSTEMSupplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required.
55317.3.7:PUBLIC ADDRESS SYSTEMSupplying, installation, testing & commissioning of digital audio amplifier 75 Watt, 25V rms operating at 240 Volt AC Supply complete as required.
55417.5.2:CABLING & WIRINGSupplying & laying of 2x1.5 sq mm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
555OD149037/2025-2026:Supply and providing 6mm thick MS chequered plate cut to shape and place in position excluding frame work if required
556OD187672/2025-2026:Charges for core cutting concrete wall of dia 150 /100 mm, fixing existing suction pipe Pressure grouting etc as required
557OD187667/2025-2026:EMEREGENCY LIGHT :- Supply and fixing Emergency Fire escape LED light with 2 nos LED lamps, 7 AH SMF battery Charging unit Exit sign display etc complete in MS enclosure.
558OD187671/2025-2026:Supply and providing Assembly point sign boards of 3mm PVC foam board size not less than 16'x16' as required
559OD149038/2025-2026:Supply and installation of laminated sheet of "Fire evacuation Plan" of suitable size & necessary accessories to fix the plan on wall
560OD149039/2025-2026:Supply & erection of Glow Sign Boardmade of 3mm thick PVC foam board for each floor 12\\" x 4\\" (Fire Lift, Fire Exit passenger Lift in each floor, Electrical Duct, Fire Station, Main Stair, Fire Exit, Floor Display, Pump Room, Plumbing Duct & Floor level.
561OD107803/2025-2026:Charges for preparation of Electrical/fire Drawing per A3 sheet first copy
562OD107802/2025-2026:Copying charges of Electrical/fire Drawing per A3 sheet additional copies
563Air-Conditioing Units(Electrical work)
564OD52609/2025-2026:Supply, installation, testing and commissioning of four way cassette type VRF indoor unit. All indoors have electronic expansion valve that controlsthe flow of refrigerant in respond to the load variations of room according to set temperature, which can set by remote controllers. Electricity characteristics for indoor unit shall be 240 volts/ 1phase /50hz. Unit shall be provided wireless remote controller and it should facilitate on/ offfunction, change of temperature settings, fan speed setting, operation mode settings as required. 4-Way Cassette Type - 0.8 TR
565OD52610/2025-2026:Supply, installation, testing and commissioning of four way cassette type VRF indoor unit. All indoors have electronic expansion valve that controlsthe flow of refrigerant in respond to the load variations of room according to set temperature, which can set by remote controllers. Electricity characteristics for indoor unit shall be 240 volts/ 1phase /50hz. Unit shall be provided wireless remote controller and it should facilitate on/ offfunction, change of temperature settings, fan speed setting, operation mode settings as required. 4-Way Cassette Type - 1 TR
566OD52612/2025-2026:Supply, installation, testing and commissioning of four way cassette type VRF indoor unit. All indoors have electronic expansion valve that controlsthe flow of refrigerant in respond to the load variations of room according to set temperature, which can set by remote controllers. Electricity characteristics for indoor unit shall be 240 volts/ 1phase /50hz. Unit shall be provided wireless remote controller and it should facilitate on/ offfunction, change of temperature settings, fan speed setting, operation mode settings as required. 4-Way Cassette Type 1.5TR
567OD52611/2025-2026:Supply, installation, testing and commissioning of four way cassette type VRF indoor unit. All indoors have electronic expansion valve that controlsthe flow of refrigerant in respond to the load variations of room according to set temperature, which can set by remote controllers. Electricity characteristics for indoor unit shall be 240 volts/ 1phase /50hz. Unit shall be provided wireless remote controller and it should facilitate on/ offfunction, change of temperature settings, fan speed setting, operation mode settings as required. 1-Way Cassette Type - 2.0 TR
568OD52628/2025-2026:Supply, Installation, Testing and Commissioning of modular type VRF odu. the outdoor unit shall be factory assembled, weather proof casing, constructed from heavy gauge mild steel panels and coated with baked enamel finish. The unit should be completely factory wired tested with all necessary controls. Outdoors units of the VRF /VRV system shall be compact air-cooled type. all the compressors of the outdoor units must be hermetically sealed BLDC inverter scroll/twin rotary type. Oem should use there on make compressors in VRF /VRV system which is to be supplied. System cop shall not be less than 3.4 at AHRI Conditions Air condition and suitable to operate at heat load proportional to indoor temperature requirement. Aluminum fins of condenser coil shall have anti corrosive epoxy resin ocean black coating along with hydrophilic coating pre coated at factory. The anti-corrosive treatment should have been tested for at least 2500 hrs of standard salt spray test and must have a certified life of minimum 20 years supported by certificate from reputed international institution is mandatory. The treatment should be suitable for areas of high pollution and salt laden air. modular system to be configured as per mention modules given in bracket and its connected accessories as required. 22 HP
569OD52629/2025-2026:Supply, Installation, Testing and Commissioning of modular type VRF odu. the outdoor unit shall be factory assembled, weather proof casing, constructed from heavy gauge mild steel panels and coated with baked enamel finish. The unit should be completely factory wired tested with all necessary controls. Outdoors units of the VRF /VRV system shall be compact air-cooled type. all the compressors of the outdoor units must be hermetically sealed BLDC inverter scroll/twin rotary type. Oem should use there on make compressors in VRF /VRV system which is to be supplied. System cop shall not be less than 3.4 at AHRI Conditions Air condition and suitable to operate at heat load proportional to indoor temperature requirement. Aluminum fins of condenser coil shall have anti corrosive epoxy resin ocean black coating along with hydrophilic coating pre coated at factory. The anti-corrosive treatment should have been tested for at least 2500 hrs of standard salt spray test and must have a certified life of minimum 20 years supported by certificate from reputed international institution is mandatory. The treatment should be suitable for areas of high pollution and salt laden air. modular system to be configured as per mention modules given in bracket and its connected accessories as required.18 HP
570OD52734/2025-2026:Supply, Installation, Testing and Commissioning of modular type VRF odu. the outdoor unit shall be factory assembled, weather proof casing, constructed from heavy gauge mild steel panels and coated with baked enamel finish. The unit should be completely factory wired tested with all necessary controls. Outdoors units of the VRF /VRV system shall be compact air-cooled type. all the compressors of the outdoor units must be hermetically sealed BLDC inverter scroll/twin rotary type. Oem should use there on make compressors in VRF /VRV system which is to be supplied. System cop shall not be less than 3.4 at AHRI Conditions Air condition and suitable to operate at heat load proportional to indoor temperature requirement. Aluminum fins of condenser coil shall have anti corrosive epoxy resin ocean black coating along with hydrophilic coating pre coated at factory. The anti-corrosive treatment should have been tested for at least 2500 hrs of standard salt spray test and must have a certified life of minimum 20 years supported by certificate from reputed international institution is mandatory. The treatment should be suitable for areas of high pollution and salt laden air. modular system to be configured as per mention modules given in bracket and its connected accessories as required. 16 HP
571OD52631/2025-2026:Supply, Installation, Testing and Commissioning of modular type VRF odu. the outdoor unit shall be factory assembled, weather proof casing, constructed from heavy gauge mild steel panels and coated with baked enamel finish. The unit should be completely factory wired tested with all necessary controls. Outdoors units of the VRF /VRV system shall be compact air-cooled type. all the compressors of the outdoor units must be hermetically sealed BLDC inverter scroll/twin rotary type. Oem should use there on make compressors in VRF /VRV system which is to be supplied. System cop shall not be less than 3.4 at AHRI Conditions Air condition and suitable to operate at heat load proportional to indoor temperature requirement. Aluminum fins of condenser coil shall have anti corrosive epoxy resin ocean black coating along with hydrophilic coating pre coated at factory. The anti-corrosive treatment should have been tested for at least 2500 hrs of standard salt spray test and must have a certified life of minimum 20 years supported by certificate from reputed international institution is mandatory. The treatment should be suitable for areas of high pollution and salt laden air. modular system to be configured as per mention modules given in bracket and its connected accessories as required. Make: 14 HP
572OD52632/2025-2026:Supply, Installation, Testing and Commissioning of modular type VRF odu. the outdoor unit shall be factory assembled, weather proof casing, constructed from heavy gauge mild steel panels and coated with baked enamel finish. The unit should be completely factory wired tested with all necessary controls. Outdoors units of the VRF /VRV system shall be compact air-cooled type. all the compressors of the outdoor units must be hermetically sealed BLDC inverter scroll/twin rotary type. Oem should use there on make compressors in VRF /VRV system which is to be supplied. System cop shall not be less than 3.4 at AHRI Conditions Air condition and suitable to operate at heat load proportional to indoor temperature requirement. Aluminum fins of condenser coil shall have anti corrosive epoxy resin ocean black coating along with hydrophilic coating pre coated at factory. The anti-corrosive treatment should have been tested for at least 2500 hrs of standard salt spray test and must have a certified life of minimum 20 years supported by certificate from reputed international institution is mandatory. The treatment should be suitable for areas of high pollution and salt laden air. modular system to be configured as per mention modules given in bracket and its connected accessories as required. 12 HP
573OD52613/2025-2026:Supply, installation, testing and commissioning of Four way cassette type VRF indoor unit. All indoors have electronic expansion valve that controlsthe flow of refrigerant in respond to the load variations of room according to set temperature, which can set by remote controllers. Electricity characteristics for indoor unit shall be 240 volts/ 1phase /50hz. Unit shall be provided wireless remote controller and it should facilitate on/ offfunction, change of temperature settings, fan speed setting, operation mode settings and its connected accessories as required. 4-Way Cassette Type - 4.0 TR
574OD52614/2025-2026:Supply, installation, testing and commissioning of Four way cassette type VRF indoor unit. All indoors have electronic expansion valve that controlsthe flow of refrigerant in respond to the load variations of room according to set temperature, which can set by remote controllers. Electricity characteristics for indoor unit shall be 240 volts/ 1phase /50hz. Unit shall be provided wireless remote controller and it should facilitate on/ offfunction, change of temperature settings, fan speed setting, operation mode settings and its connected accessories as required. 4-Way Cassette Type - 3.0 TR
575OD52615/2025-2026:Supply, installation, testing and commissioning of Four way cassette type VRF indoor unit. All indoors have electronic expansion valve that controlsthe flow of refrigerant in respond to the load variations of room according to set temperature, which can set by remote controllers. Electricity characteristics for indoor unit shall be 240 volts/ 1phase /50hz. Unit shall be provided wireless remote controller and it should facilitate on/ offfunction, change of temperature settings, fan speed setting, operation mode settings and its connected accessories as required. 4-Way Cassette Type - 2.0 TR
576OD52617/2025-2026:Supply, installation, testing and commissioning of high static ductable unit. The indoor unit shall be of the high static ductable as per the requirements specified. All indoor units should have inbuilt drain pump with minimum 700mm vertical lift head. Indoor fan motors shall be BLDC type .all indoors have electronic expansion valve that controls the flow of refrigerant in respond to the load variations of room according to set temperature,which can set by remote controllers. Electricity characteristics for indoor unit shall be 240 volts/ 1phase /50h Z.I. casing shall be made of galvanized steel sheet (G.S.S) with minimum 0.8 mm thickness. Zinc coating thickness on G.S.S shall be of minimum 220 GSS. ii. Inner and outer side of the casing shall have noise absorbing polyethylene insulation with adequate thickness. iii. Unit shall be provided wired remote controller and it should facilitate on/ off function, change of temperature settings, fan speed setting, operation mode setting, clock function and error code display. High Static Ductable Unit and its connected accessories as required. HIGH STATIC TYPE DUCTALBLE UNIT- 8.0 TR
577OD52618/2025-2026:Supply, installation, testing and commissioning of high static ductable unit. The indoor unit shall be of the high static ductable as per the requirements specified. All indoor units should have inbuilt drain pump with minimum 700mm vertical lift head. Indoor fan motors shall be BLDC type .all indoors have electronic expansion valve that controls the flow of refrigerant in respond to the load variations of room according to set temperature,which can set by remote controllers. Electricity characteristics for indoor unit shall be 240 volts/ 1phase /50h Z.I. casing shall be made of galvanized steel sheet (G.S.S) with minimum 0.8 mm thickness. Zinc coating thickness on G.S.S shall be of minimum 220 GSS. ii. Inner and outer side of the casing shall have noise absorbing polyethylene insulation with adequate thickness. iii. Unit shall be provided wired remote controller and it should facilitate on/ off function, change of temperature settings, fan speed setting, operation mode setting, clock function and error code display. High Static Ductable Unit and its connected accessories as required. HIGH STATIC TYPE DUCTALBLE UNIT- 6.3 TR
57816.12.2.2:Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.8. mm thick
57916.12.2.1:Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.63 mm thick
58016.23.2:Supplying and fixing of following thickness duly laminated aluminum foil of matfinish closed cell Nitrile rubber (Class \\"\\"O\\"\\") insulation on existing duct afterapplying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete asper specifications and as required.Nitrille rubber insulation - 25 mm
581OD53063/2025-2026:Supply and fixing of the fire retardant type canvas for inter connecting cooling unit with duct/plenum and fixed in front area of the unit to avoid excess vibration with required accessories as required
582OD53122/2025-2026:Supply and Fixing Acoustic Lining of ducts using 10mm thick Nitrile foam anti-microbial self adhesive open cell Nitrile Rubber insulation with recommended adhesives as required
58316.13:Supply, installation, testing and commissioning of GI volume control ductdamper complete with neoprene rubber gaskets, nuts, bolts, screws linkages,flanges etc, as per specifications.Gl volume control duct damper
58416.16:Supplying & fixing of powder coated extruded aluminum Return Air Grills with louvers but without volume control dampers complete as required.
58516.15:Supplying & fixing of powder coated extruded aluminium Supply Air Grills withaluminium volume control dampers as per specifications.
58616.17:Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminum with aluminum volume control dampers with anti smudge ring and removable core.
58716.18:Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminum without volume control dampers with anti smudge ring and removable core.
588OD52830/2025-2026:Supply, installation, testing and commissioning of Y joints with connected accessories for Outdoor side as required
589OD52831/2025-2026:Supply, installation, testing and commissioning of Y joints with connected accessories for indoor side as required
590OD52986/2025-2026:SITC of hard drawn copper refrigerant piping including all accessories including joints properly brazed insulated with chemically crosslinked nitrile rubber fire retardant grade class 'O' 13 mm Thickness necessary supports as required of size 6.35 mm dia as required
591OD52985/2025-2026:SITC of hard drawn copper refrigerant piping including all accessories including joints properly brazed insulated with chemically crosslinked nitrile rubber fire retardant grade class 'O' 13 mm Thickness necessary supports as required of size 9.52 mm dia as required
592OD52984/2025-2026:SITC of hard drawn copper refrigerant piping including all accessories including joints properly brazed insulated with chemically crosslinked nitrile rubber fire retardant grade class 'O' 13 mm Thickness necessary supports as required of size 12.7 mm dia as required
593OD52983/2025-2026:SITC of hard drawn copper refrigerant piping including all accessories including joints properly brazed insulated with chemically crosslinked nitrile rubber fire retardant grade class 'O' 13 mm Thickness necessary supports as required of size 15.9 mm dia as required
594OD52988/2025-2026:SITC of hard drawn copper refrigerant piping including all accessories including joints properly brazed insulated with chemically crosslinked nitrile rubber fire retardant grade class 'O' 13 mm Thickness necessary supports as required of size 19.05 mm dia as required
595OD52992/2025-2026:SITC of hard drawn copper refrigerant piping including all accessories including joints properly brazed insulated with chemically crosslinked nitrile rubber fire retardant grade class 'O' 13 mm Thickness necessary supports as required of size 22.2 mm dia as required
596OD52987/2025-2026:SITC of hard drawn copper refrigerant piping including all accessories including joints properly brazed insulated with chemically crosslinked nitrile rubber fire retardant grade class 'O' 13 mm Thickness necessary supports as required of size 28.6 mm dia as required
597OD52991/2025-2026:SITC of hard drawn copper refrigerant piping including all accessories including joints properly brazed insulated with chemically crosslinked nitrile rubber fire retardant grade class 'O' 13 mm Thickness necessary supports as required of size 34.9 mm dia as required
598OD52990/2025-2026:SITC of hard drawn copper refrigerant piping including all accessories including joints properly brazed insulated with chemically crosslinked nitrile rubber fire retardant grade class 'O' 13 mm Thickness necessary supports as required of size 38.1 mm dia as required
599OD52989/2025-2026:SITC of hard drawn copper refrigerant piping including all accessories including joints properly brazed insulated with chemically crosslinked nitrile rubber fire retardant grade class 'O' 13 mm Thickness necessary supports as required of size 41.3 mm dia as required
60090.6.4.54:Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.10.00 sq.mm 4 Run
60190.6.4.56:Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.10.00 sq.mm 6 Run
6021.17.10:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.10 x 1.5 sq. mm
60390.6.5.18:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.4 core 1.50 sq mm
6041.17.6:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm
6051.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
6061.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
6071.21.3:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
608OD53197/2025-2026:Charges for supply and filling the R 410 refrigerant gas in the existing air conditioning system as required
60990.14.4:Supply and fabrication conveyance and installation of base frame of panel board using 75 x 40 mm rolled steel channel (ISMC)
61090.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
611OD53208/2025-2026:Supply,installation,testing and commissioning of insulated condensate drain piping out of PVC-6kg/cm2 pipes complete with hangers/ supports/ clamps/clips and all fittings etc and insulated with 13 mm thoick nitrile rubber sleeves and joints sealed with 50 mm black PVC tapes-32 mm dia
612OD187753/2025-2026:Supply and fixing of 25 mm outer dia. 10kgf cm2 PVC pipe along with all required accessories in surface/ recess including cutting the wall and making good the damages etc. as required
613OD52619/2025-2026:Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, upto 25 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge.
61414.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels
61514.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required.
616Cabling and conduits(Electronics Work)
617OD23246/2025-2026:Supply and Installation of 6 Core Single Mode OS2 Gel free dry indoor/ outdoor armoured OFC having LSZH sheath and aramid Yarn Reinforcing, Tensile Strength Min: 1500N, Crush Resistance Min: 3000N/10CM, Anti rodent/anti termite conforming to IEC 60794-1, RoHS compliant etc.Preferred Make: AFL, Commscope, Molex, R and M, Sterlite.
618OD25819/2025-2026:Supply and Installation of 12 Core Single Mode OS2 Gel free dry indoor/ outdoor armoured OFC having LSZH sheath and aramid Yarn Reinforcing, Tensile Strength Min: 1500N, Crush Resistance Min: 3000N/10CM, Anti rodent/anti termite conforming to IEC 60794-1, RoHS compliant etc.Preferred Make: AFL, Systimax, Molex, R and M, Panduit.
619OD23251/2025-2026:Supply, Installation, Testing and commissioning of 42U floor mount Server Rack with 4 fans, 4 heavy duty castor wheels, minimum 3 numbers of 22 slot rack mount horizontal cable managers, toughened glass door, hardware kits, minimum 2 numbers of 6 port PDU, minimum 3 rack mount trays, etc.Preferred Make: APC, Legrand, Netrack, Rittal, Vertiv or equivalant
620OD25900/2025-2026:Supply, Installation, Testing and commissioning of 27U floor mount Server Rack with minimum 2 fans, 4 heavy duty castor wheels, minimum 3 numbers of 22 slot rack mount horizontal cable managers, toughened glass door, hardware kits, 6 port PDU, minimum 1 rack mount trays, etc.Preferred Make: APC, Legrand, Netrack, Rittal, Vertiv or equivalent
621OD25822/2025-2026:Supply, Installation, Testing and commissioning of 24U floor mount Rack with minimum 2 fans, 4 heavy duty castor wheels, minimum 3 numbers of 22 slot rack mount horizontal cable managers, toughened glass door, hardware kits, 6 port PDU, etc.Preferred Make: APC, Legrand, Netrack, Rittal, Vertiv or equivalent
622OD25965/2025-2026:Supply and fixing 19 inch, 15U wall mount Network Rack with ACDB 6 port, minimum 2 numbers of Slot Rack Mount Horizontal cable manager duct, 2 Fan etc.Preferred Make: D-Link, HCL, Netrack, President, Valrack or equivalent.
623OD23253/2025-2026:Supply and fixing 19 inch, 12U wall mount Network Rack with ACDB 6 port, Slot Rack Mount Horizontal cable manager duct, 2 Fan etc.Preferred Make: D-Link, HCL, Netrack, President, Valrack or equivalent.
624OD26334/2025-2026:Supply and fixing 19 inch, 9U wall mount Network Rack with ACDB 6 port, rack mountable Tray, 2 Fan etc.Preferred Make: D-Link, HCL, Netrack, President, Valrack or equivalent.
625OD23275/2025-2026:Supply and Installation of 19 inch 24 port rack mountable 1U size complete Steel housing fully powder coated Light Interface Unit (LIU) having FR grade Nylon Cable grommets, ABS Splice Trays with fully cushioned splice holder containing grooves for fixing splice protection sleeves, Cable Spools made up of flame retardant plastic, high impact resistance, stackable design for providing sufficient room for storage of excess cables, Blanking plates, adapter plates etc.Approved Make: Actassi, AFL, Belden, Molex, Panduit, R and M, Sterlite, Systimax
626OD23274/2025-2026:Supply and Installation of 19 inch 12 port rack mountable 1U size complete Steel housing fully powder coated Light Interface Unit (LIU) having FR grade Nylon Cable grommets, ABS Splice Trays with fully cushioned splice holder containing grooves for fixing splice protection sleeves, Cable Spools made up of flame retardant plastic, high impact resistance, stackable design for providing sufficient room for storage of excess cables, Blanking plates, adapter plates etc.Approved Make: Actassi, AFL, Belden, Molex, Panduit, R and M, Sterlite, Systimax
627OD23272/2025-2026:Supply and Installation of 19 inch 6 port rack mountable 1U size complete Steel housing fully powder coated Light Interface Unit (LIU) having FR grade Nylon Cable grommets, ABS Splice Trays with fully cushioned splice holder containing grooves for fixing splice protection sleeves, Cable Spools made up of flame retardant plastic, high impact resistance, stackable design for providing sufficient room for storage of excess cables, Blanking plates, adapter plates etc.Approved Make: Actassi, AFL, Belden, Molex, Panduit, R and M, Sterlite, Systimax
628OD23273/2025-2026:Supply, Installation, Testing and commissioning of SC Duplex single mode adapter connected through 2 pigtails and spliced it to the existing Fiber in the existing LIU (splicing charges included), etc.Approved Make: Actassi, AFL, Belden, Molex, Panduit, R and M, Sterlite, Systimax
6291.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
6301.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
6311.21.3:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
6324.1.2:Supplying and installing following size of perforated painted with powder coatingM.S. cable trays with perforation not more than 17.5%, in convenient sections,joined with connectors, suspended from the ceiling with M.S. suspendersincluding bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness
6334.1.3:Supplying and installing following size of perforated painted with powder coatingM.S. cable trays with perforation not more than 17.5%, in convenient sections,joined with connectors, suspended from the ceiling with M.S. suspendersincluding bolts & nuts, painting suspenders etc as required.225 mm width X 50 mm depth X 1.6 mm thickness
6344.2.3:Supplying and installing following size of perforated pre-painted M.S. cable trays bends withperforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.225 mm width X 50 mm depth X 1.6 mm thickness
6354.4.3:Supplying and installing following size of perforated painted with powder coatingM.S. cable trays Cross Member with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts &nuts, painting suspenders etc as required.225 mm width X 50 mm depth X 1.6 mm thickness
636OD357936/2025-2026:Supplying and drawn of UTP 4 pair LSZH CAT 6 LAN cable 23 AWG in the existing surface/recessed steel/PVC conduit and casing and capping as required, 1 run of CableApproved Make: Actassi, Belden, Panduit, Molex, R and M, Systimax .
637OD357944/2025-2026:Supplying and drawn of UTP 4 pair LSZH CAT 6 LAN cable 23 AWG in the existing surface/recessed steel/PVC conduit and casing and capping as required, 2 run of CableApproved Make: Actassi, Belden, Panduit, Molex, R and M, Systimax .
638OD357952/2025-2026:Supplying and drawn of UTP 4 pair LSZH CAT 6 LAN cable 23 AWG in the existing surface/recessed steel/PVC conduit and casing and capping as required, 3 run of CablesApproved Make: Actassi, Belden, Panduit, Molex, R and M, Systimax .
639OD54443/2025-2026:Supplying and drawn of U/FTP 4 pair LSZH CAT 6A LAN cable 23 AWG in the existing surface/recessed steel/PVC conduit as required, RoHS compliantApproved Make: Actassi, Belden, Molex, Panduit, R and M, Systimax
640OD54444/2025-2026:Supply and fixing 24 port Enhanced CAT-6, unloaded rack mountable modular type Patch Panel as per EIA/TIA-TSB 40A specification for interconnecting servers and clients, including termination charges.Approved Make: Actasi, Belden, R&M, Molex
641OD50207/2025-2026:Supply, Installation, Testing and Fixing of UL Listed CAT6 Keystone for existing patch panel of blue/grey/ other color for LANApproved Make: Actassi, Belden, Systimax, R&M, Molex
642OD50206/2025-2026:Supply, Installation, Testing and Fixing of UL Listed CAT6 Keystone for existing patch panel of Orange/Red/ (other than data) color for CamerasApproved make: Actassi, Belden, Systimax, R&M, Molex
643OD54564/2025-2026:Supply & providing 1Mtr LSZH CAT-6 Giga UTP patch cord of blue/grey/ (preferred color for data) color.Approved Make: Actassi, Belden, Panduit, R&M, Molex
644OD54563/2025-2026:Supply & providing 1Mtr LSZH CAT-6 Giga UTP patch cord of Orange/Red/ (preferred color for camera )color.Approved Make: Actassi, Belden, Panduit, R&M, Molex
645OD50539/2025-2026:Supply, Installation and Fixing of 1 or 2 module GI box (75mm x 75mm x 60mm deep) on Recess including making good the damages, etc as required.
646OD54440/2025-2026:Supply and fixing of UL certified 1 or 2 module PVC Box on Surface/Recess including making good the damages, color washing, etc. as requiredApproved Make: Actassi, Belden, Molex, Panduit, R and M, Systimax
647OD50204/2025-2026:Supply, Installation and fixing of UL Certified CAT-6 Information Outlet for 1000Mbps having spring shutter / dust cover for dust protection angled face plate + Single RJ45 Keystone sockets in the existing CMS/PVC Box/ GI Box, including termination charges etc.Approved Make: Actassi, Belden, Molex, Panduit, R and M, Systimax
648OD50205/2025-2026:Supply, Installation and Fixing of UL Certified CAT-6 information outlet for 1000Mbps having spring shutter / dust cover for dust protection dual angled face plate, two numbers of RJ45 keystone sockets in the existing CMS/PVC Box/ GI Box, including termination charges etc.Approved Make: Actassi, Belden, Molex, Panduit, R and M, Systimax
649OD54607/2025-2026:Supply and providing 3Mtr LSZH CAT-6 Giga UTP patch cord.Approved Make: Actassi, Belden, Panduit, R&M, Molex
650OD54619/2025-2026:Supply and installation of weather proof and water proof 4x4 square PVC Junction box for camera.
651OD54628/2025-2026:Supply and fixing of UL Certified 1 or 2 module modular PVC Box on surface/Recess with blanking plate including making good the damages etc for CCTV connection terminationApproved Make: Actassi, Belden, Panduit, R&M, Honeywell
652OD54624/2025-2026:Supply and Installaion of Camera Housings Dimensions : 165.1 x 120.7 x 295.3 mm or equivalent dimensions for out side cameras including accessories for mounting etc.
65390.9.2.1:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.100 x 50 mm CMS with base and lid
65490.9.2.8:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.End cap
65590.9.2.3:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.External angle 90 degree
65690.9.2.5:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Internal angle 90 degree
657OD54911/2025-2026:Supply & providing SC-LC duplex patch cord 1 mtr.Preferred Make: Commscope, Molex, R&M, Sterlite or equivalent
6581.17.11:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm
659OD91688/2025-2026:Charges for permanent numbering of all Information Outlets, labelling on existing all racks, marking on uplink cables, labelling and numbering of existing LIU and fiber ports and cable, and documentation such as network and Camera wiring diagram of all the nodes from patch panel and Up-links from switches on the rack for network and cameras for all departments, covering and closing of all the nodes and racks inlet holes with dust proof materials for protection from outside etc..
660Rack earthing(Electronics Work)
6615.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
6625.7:Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
6635.19:Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
664OD49669/2025-2026:Supply and Installation for Earth Bench/Terminal Strip, Terminal Connector 6/8 Hole, Copper-plated bar for optimal conductivity, as per IEC standards
665LAN Switches Active Parts(Electronics Work)
666OD54761/2025-2026:Supply and Installation of Layer 3 supported fully Managable 24 port Ethernet stackable Switch having 12x10GBase-T + 12x SFP+ ports, switching fabric: 480Gbps or more, throughput: 357 Mpps or more, support upto 4093 VLANs and 16K or more MAC address, device should have minimum 1GB RAM, 256 MB flash memory , rack mountable and other accessories etc. AC 230V power inputApproved Make: Allied Telesis, Cisco, Juniper, Aruba ,Ruckus, Netgear
667OD54727/2025-2026:Supply and Installation of Layer 3 supported fully Managable 16 port Ethernet stackable Switch having 8x10GBase-T + 8x SFP+ ports, switching fabric: 320Gbps or more, throughput: 238 Mpps or more, support upto 4093 VLANs and 16K or more MAC address, device should have minimum 1GB RAM, 256 MB flash memory , rack mountable and other accesories etc. AC 230V power inputApproved Make: Allied Telesis, Cisco, Juniper, Aruba ,Ruckus, Netgear
668OD54801/2025-2026:Supply and Installation of Layer 3 supported fully Managable 24 port Ethernet stackable Switch having 24x1G and 4x10G including 2x10GBASE-T and 2xSFP+ Ports, switching fabric: 128Gbps or more, throughput: 95.2 Mpps or more, support upto 4093 VLANs and 16K or more MAC address, device should have minimum 1GB RAM, 256 MB flash memory , rack mountable and other accessories etc. AC 230V power inputApproved Make: Allied Telesis, Cisco, Juniper, Aruba ,Ruckus, Netgear
669OD54851/2025-2026:Supply and Installation of Layer 3 supported fully Managable 24 port PoE+ Ethernet stackable Switch having 24x1G PoE+, 2x10GBASE-T and 2xSFP+ Ports, Power 480W, switching fabric: 128Gbps or more, throughput: 95.2 Mpps or more, support upto 4093 VLANs and 16K or more MAC address, device should have minimum 1GB RAM, 256 MB flash memory, rack mountable and other accessories etc. AC 230V power inputApproved Make: Allied Telesis, Cisco, Juniper, Aruba ,Ruckus, Netgear
670OD54884/2025-2026:Supply, Installation, testing and Commissioning of 24 port managed Switch having 24x 10/100/1000BASE-T RJ45 Ports, 4x SFP+ ports, Bandwidth: 128 Gbps or more, 16K MAC, 256 VLANs, Jumbo frame support (bytes): Up to 10K packet size or more, 512MB RAM or higher , Packet forwarding rate: 83.52 or higher, including all other accessoriesApproved Make: Allied Telesis, Cisco, Juniper, HP, Aruba ,Ruckus, Netgear
671OD54886/2025-2026:Supply, Installation, testing and Commissioning of 24 port POE+ managed Switch having 24x 10/100/1000BASE-T RJ45 POE+ Ports, 4x SFP+ ports, Bandwidth: 128 Gbps or more, 16K MAC, 256 VLANs, Power: 190W, Jumbo frame support (bytes): Up to 10K packet size or more, 512MB RAM or higher , Packet forwarding rate: 95.24 or higher, including all other accessoriesApproved Make: Allied Telesis, Cisco, Juniper, HP, Aruba ,Ruckus, Netgear
672OD54870/2025-2026:Supply, Installation, Testing and Commissioning of 3 meter Direct Attach Cable with SFP+ on both sidesApproved Make: Allied Telesis, Cisco, Juniper, Aruba ,Ruckus, Netgear
673OD54889/2025-2026:Supply and Installation of Layer 2 Manageable 24 port Ethernet Switch having 24 x10/100/1000 Mbps + minimum 2 x GbE SFP ports, 52 Gbps bandwidth, 256 or more VLANs and 16K MAC address, supporting ipv6, Priority levels up to 8 hardware queues, up to 9216 Jumbo frames, AC 230V power input.Approved Make: Allied Telesis, Aruba, Brocade, Cisco, Fortinet, HP, Juniper, Netgear, Ruckus
674OD54890/2025-2026:Supply and Installation of Layer 2 Managable 24 or more port POE+ Ethernet Switch having 24 x 10/100/1000 Mbps + minimum 2 x GbE SFP Auto-sensing Gigabit ports (Power 190W or more) ports, 52 Gbps bandwidth, supporting ipv6, Priority levels up to 8 hardware queues, up to 9216 Jumbo frames, VLAN support, AC 230V power input.Approved Make: Allied Telesis, Cisco, Juniper, Aruba, Ruckus, Netgear
675OD54909/2025-2026:Supply, Installation, Testing and Commissioning of 10G single mode dual fiber SFP+ module Approved Make: Allied Telesis, Cisco, Juniper, HP, Aruba ,Ruckus, Netgear (Make should be same as Above Switch)
676OD55463/2025-2026:Supply and Installation of 1G duplex SFP moduleAccepted Make: Same make as Network Switch above
677CCTV and active items(Electronics Work)
678OD55268/2025-2026:Supply, installation, testing and commissioning of project series STQC certified Motorized Varifocal 5MP IP Bullet camera, 2.8 mm -12 mm lens or better, 1/2.7 or better inch CMOS sensor, IR Distance minimum 50 meter, progressive scan, Min illumination: 0.004 or less, 120 dB WDR, 3D DNR, auto ICR, ONVIF (S, G, T or more profiles), Video Compression: H.265+/ H.265/H.264 or better codecs, Support SD Card of minimum 256 Gb, protection: IP67, Audio in/out, Certification: CE, FCC, RoHS, BIS, ISO etc, POE, Motion detection, Face Recognition, Line Crossing Detection, Crowd density detection, Intrusion detection including suitable mounting accessories as per the site etc.
679OD55280/2025-2026:Supply, Installation, Testing and Commissioning of 5MP STQC certified IP Bullet Camera with Image Sensor: 1/2.7 inch or better, Lens: 3.6mm fixed lens, Resolution: 2592x1944 or Higher, IR Distance: 30 Meter, Min illumination 0.003lux or better, inbuilt mic, Video Compression: H.265+, H.265, H.264, MJPEG , Motion Detection, ONVIF (Profile S/Profile G/Profile T); Smart Detection: Face Recognition, Perimeter Intrusion Detection, Line Crossing Detection, Cross Counting, Crowed density Detection, WDR(120dB),Micro SD Card Slot up to 256GB, ICR auto switch Power Source: 12V DC/PoE Casing: Metal, Standard: IP67 Certification: CE, FCC, ROHS, BIS, ISO:9001
680OD55291/2025-2026:Supply, installation, testing and commissioning of Project series STQC certified 5MP IP Dome camera, 2.8 mm lens, 1/2.7 or better inch CMOS sensor, IR Distance minimum 30 or more meter, progressive scan, Min illumination: 0.003 or less, 120 dB WDR, 3D DNR, auto ICR, ONVIF (S, G, T or more profiles), Video Compression: H.265+/H.265/ H.264 or better codecs, Support SD Card of minimum 256 Gb, protection: IP67 and vandal proof, Audio in/out, Certification: CE, FCC, RoHS, BIS, ISO etc, POE, Motion detection, Intrusion detection, Face Recognition, Crowed density detection including suitable mounting accessories as per the site etc.
681OD55245/2025-2026:Supply and Installation of Minimum 64 Channel Network Video Recorder support resolution up to 12 MP IP camera, Network Bandwidth: 640 Mbps for access, storage and forwarding H.265+/H.265/H.264 video compression, Network: 2X RJ-45 10/100/1000Mbps Ethernet Interfaces, 8 SATA HDD ports each supports 16TB/18TB, RAID support, External ports: 2 VGA, minimum 2 HDMI, 3 USB, audio out, audio in etc. Smart Functions: Face detection; face recognition; perimeter protection; Crowed density detection. certifications and markings such as FCC, CE, RoHS, BIS, ISO etc. including all accessories
682OD55346/2025-2026:Supply and Installation of Minimum 32 or more Channel Network Video Recorder support resolution up to 12 MP IP camera, Network Bandwidth: 320 Mbps for access, storage and forwarding H.265+/H.265/H.264 video compression, Network: 2X RJ-45 10/100/1000Mbps Ethernet Interfaces, 4 SATA HDD ports each supports 12TB, External ports: 1 VGA, minimum 2 HDMI, minimum 2 USB, audio out, audio in etc. Smart Functions: Face detection, motion detection. certifications and markings such as FCC, CE, RoHS, BIS, ISO etc. including all accessoriesApproved Make: Axis, Avtron, Bosch, Honeywell, Hanwha vision, Panasonic, Norden, Tyco
683OD54992/2025-2026:Supply and Installation of Layer 2 Manageable 28 port POE+ Ethernet Switch having 24 x 10/100/1000 Mbps + minimum 4 x GbE SFP Auto-sensing Gigabit ports (Power 380W or more) ports, 56 or more Gbps bandwidth, Packet forwarding rate: 41.67 Mpps, supporting ipv6, Priority levels up to 8 hardware queues, up to 9216 Jumbo frames, VLAN support minimum 255 numbers, AC 230V power input. Approved Make: Allied Telesis, Cisco, Juniper, Aruba, Ruckus, Netgear
684OD54995/2025-2026:Supply and Installation of Layer 2 Managable 24 port POE+ Ethernet Switch having 24 x 10/100/1000 Mbps + minimum 2 x GbE SFP Auto-sensing Gigabit ports (Power 380W or more) ports, 52 Gbps bandwidth, supporting ipv6, Priority levels up to 8 hardware queues, up to 9216 Jumbo frames, VLAN support, AC 230V power input.Approved Make: Allied Telesis, Cisco, Juniper, Aruba, Ruckus, Netgear
685OD55002/2025-2026:Supply and Installation of 24 Port Smart/ Managed Switch having 24 ports PoE+ Gigabit ports (Power 190W), and Four Gigabit SFP fiber ports, Bandwidth 56 Gbps, 41.67 Mpps Packet forwarding rate, AC 230V power input.Approved Make: Cisco, Allied Telesis, Brocade, Cisco, Netgear
686OD55001/2025-2026:Supply and Installation of Layer 2 Managable 24 or more port POE+ Ethernet Switch having 24 x 10/100/1000 Mbps + minimum 2 x GbE SFP Auto-sensing Gigabit ports (Power 190W or more) ports, 52 Gbps bandwidth, supporting ipv6, Priority levels up to 8 hardware queues, up to 9216 Jumbo frames, VLAN support, AC 230V power input.Approved Make: Allied Telesis, Cisco, Juniper, Aruba, Ruckus, Netgear
687OD90586/2025-2026:Supply, Installation, Testing and Commissioning of 8 Port or more Network PoE+ smart Manageable Switch having minimum 8 x PoE+ Gigabit ports, minimum 2 Gigabit SFP fiber uplink ports, Power 55W or more, AC 230V power input. etc.Approved Make: Allied Telesis, Brocade, Cisco, Juniper, HP, Netgear
688OD55009/2025-2026:Supply and Installation of 1G duplex SFP moduleAccepted Make: Same make as Network Switch above
689OD55397/2025-2026:Supply and Installation of 10 TB Surveillance Hard Disk Drive.Preferred Make: Barracuda, Seagate, WD or equivalent
690OD55439/2025-2026:Supply and Installation of 55 or more inch LED Professional Display capable of working 16x7 with resolution of Full HD or higher with necessary wall mount kit. Preferred Model: Sony, LG, Samsung or equivalent
691OD358178/2025-2026:Supply and Installation of 50 or more inch LED Professional Display capable of working 16x7 with resolution of minimum Full HD or higher with necessary wall mount kit. Preferred Model: Sony, LG, Samsung, Panasonic or equivalent
692OD55445/2025-2026:supply, Installation, Testing and Commissioning of wireless mouse with receiver including required length USB cable to keep the receiver outside of the rack.
693OD55446/2025-2026:Supply and Installation of 10 Meter or more HDMI Cable (4K@30Hz)Preferred Make: Honeywell or equivalent
694OD55449/2025-2026:Supply and Installation of 15 Meter or more HDMI Cable (4K@30Hz)Preferred Make: Honeywell or equivalent
695IPBX(Electronics Work)
696OD55013/2025-2026:Supply and Installation of IPBX System having Supports up to 2000 users and up to 300 concurrent calls, 4 Analog Telephone FXS Ports, 4 FXO Ports, three Gigabit auto-sensing RJ45 network ports with integrated PoE+, includes video conferencing solution, security protection, call features includes Call park, call forward, call transfer, call waiting, caller ID, call record, call history etc. Compliance includes FCC, CE, IC, RCM, UL etc. Preffered make: Cisco, Avaya, Grandstream, Mitel, NEC or equivalent.
697OD55032/2025-2026:Supply and Installation of IPBX System having supports minimum 500 users and minimum 100 concurrent calls, 2 Analog Telephone FXS RJ11 Ports, 2 FXO RJ11 Ports, three Gigabit auto-sensing RJ45 network ports with integrated PoE+, includes video conferencing solution, security protection, call features includes Call park, call forward, call transfer, call waiting, caller ID, call record, call history etc. Compliance includes FCC, CE, IC, RCM, UL etc. Approved make: Cisco, Avaya, Grandstream, Mitel, NEC
698OD55019/2025-2026:Supply and Installation of IP Video Phone having 16 line, 16 SIP accounts, Tiltable 2 or more mega-pixel CMOS camera for video calling, Dual switched autosensing 10/100/1000 Mbps Gigabit Ethernet ports with integrated PoE/PoE+, USB port, Bluetooth, dual-band Wi-Fi (802.11 ac/ax), 7 or more inch touch LCD screen, Android 11 OS, video resolution 720p or more, Support for G7.29A/B, G.711µ/a-law, G.722, Opus or better Voice Codecs, Layer 2 QoS, Layer 3 QoS, call features includes Hold, transfer, forward, call park, 10-way audio conference etc., Dual MIC and HD speakerphone with noise shield, advanced echo cancellation, excellent double talk performance, Compliance includes FCC, CE, IC, RCM, EN etc.. Preffered make: Cisco, Avaya, Grandstream, Mitel, NEC or equivalent.
699OD55025/2025-2026:Supply and Installation of IP Phone having 2 line, 4 SIP accounts, up to 3 call appearances, Dual switched auto-negotiation 10/100 Mbps or more Ethernet ports, integrated PoE, LCD display, Support for G7.29A/B, G.711µ/a-law, G.722, Opus or better Voice Codecs, Layer 2 QoS, Layer 3 QoS, call features includes Hold, transfer, forward, 5-way conference, call park, call pickup etc., Full-duplex speakerphone with HD audio, Compliance includes FCC, CE, IC, RCM, EN etc.. Preffered make: Cisco, Avaya, Grandstream, Mitel, NEC or equivalent.
700WiFi(Electronics Work)
701OD55453/2025-2026:Supply and Installation of Wi-Fi 6 access point having Dual-band 2x2:2 MU MIMO, Supports 256 concurrent Wi-Fi client devices, Embedded controller, Wi-Fi Standards: IEEE 802.11 a/b/g/n/ac/ax, wireless throughput :1.7Gbps (aggregate), 2x Gigabit Ethernet ports, auto detection of PoE/PoE+, wall mount or ceiling mount kits, Compliance includes FCC, CE, IC, etc.Approved make: Cisco, Aruba, Netgear, Grandstream
702Cable TV(Electronics Work)
703OD55459/2025-2026:Supply and Installation of 50 or more inch LED Professional Display capable of working 16x7 with resolution of minimum Full HD or higher with necessary wall mount kit. Preferred Model: Sony, LG, Samsung, Panasonic or equivalent
704OD55460/2025-2026:Supply and Installation of 42 or more inch LED Professional Display capable of working 16x7 with resolution of Full HD or higher with necessary wall mount kit. Preferred Model: Sony, LG, Samsung or equivalent
705OD55462/2025-2026:Supply, Installation, Testing and Commissioning of Cable TV/Dish TV with minimum 1 year Subscription and required installation accessories to support all major News channels includes Splicing Box, Splitter, Converter etc Please Enable Macros to View BoQ information

Other Detail

Information Source https://etenders.kerala.gov.in
Download FileName File Description File Size
Download affidavit.pdf Tender Documents 0 KB
Download bidpattom.pdf Tender Documents 0 KB
Download BOQ_1439279.xls Tender Documents 0 KB
Download cad63989-93d2-4a05-b474-cad7e8d6ef68.html Tender Documents 0 KB
Download epay.pdf Tender Documents 0 KB
Download fot.pdf Tender Documents 0 KB
Download integritypact.pdf Tender Documents 0 KB
Download preliminaryagmnt.pdf Tender Documents 0 KB
Download Tendernotice_1 (10).pdf Tender Documents 0 KB
Disclaimer :