Indian Tenders

Tender Notice

TDR 55582410
Tendering Authority Municipal Corporation Of Delhi
Tender No EEE/SZ/2026-27/NIT/10
Tender ID 2026_MCD_278050_1
Tender Brief Corrigendum : Tender For Earthing With G.I. Earth Pipe 4.5 Metre Long, 40 Mm Dia Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. With Charcoal/ Coke And Salt As Required , Providing And Layi
City New Delhi
State Delhi
Document Fees INR 590 /-
EMD INR 19800.0 /-
Tender Value INR 9.41 Lakhs /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Earthing With G.I. Earth Pipe 4.5 Metre Long, 40 Mm Dia Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. With Charcoal/ Coke And Salt As Required , Providing And Laying Earth Connection From Earth Electrode With 6 Swg Dia G.I. Wire In 15 Mm Dia G.I. Pipe From Earth Electrode Including Connection With G.I. Thimble Excavation And Re-Filling As Required. , Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing Along With Existing Surface/ Recessed Conduit/ Submain Wiring/ Cable As Required. , Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Rcc/ Hume/ Metal Pipe As Required. Upto 35 Sq. Mm , Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Masonry Open Duct As Required. Upto 35 Sq. Mm , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. 3 X 1.5 Sq. Mm , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. 5 X 1.5 Sq. Mm , Supplying And Laying Of Following Size Dwc Hdpe Pipe Isi Marked Along With All Accessories Like Socket, Bend, Couplers Etc. Conforming To Is 14930, Part Ii Complete With Fitting And Cutting, Jointing Etc.In The Existing Trench, Complete As Required. 63 Mm Dia (Od-63 Mm & Id-51 Mm Nominal) , Supplying And Fixing Of Light Class Gi Pipe Of 50 Mm Dia (Nominal) 3 Meters Length Along The Pole For Protection Of Under Ground Cable As Required. , Excavation Of The Cable Trenches In Hard Rock Not Exceeding 1.5 Meters In Width, And Lift Upto 1.5 Meters, Including Getting Out The Excavated Soil And Disposal Of Excavated Soil As Directed Within A Lead Of 50 Meters. , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level:1:3:6 (1 Cement : 3Coarse Sand (Zone-Iii) Derived From Natural Sources : 6 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Supply Of Xlpe Insulated Pvc Sheathed Al. Conductor Armoured Cable 1.1Kv Grade Conforming To Is-7098 Of Following Size:-2C X 6 Sqmm , Supply Of Xlpe Insulated Pvc Sheathed Al. Conductor Armoured Cable 1.1Kv Grade Conforming To Is-7098 Of Following Size:-2C X 10 Qmm , Led Street Light Fixture, Powder Coated Pressure Die Cast Aluminum Body (System Lumen Efficacy 135 Lm/Watt) Supplying, Installation, Testing & Commissioning Of Street Light Led Fixture, Powder Coated Pressure Die Cast Aluminum Body With Built In Or Separate Driver As Per The Requirement With Driver Efficiency 85%, Input Voltage: 140-270 Volt Ac, Freq 50/60 Hz, Operating Temp Range -15 Deg To 50 Deg Centigrade, Internal Surge Protection Of 5 Kv L,N,E As Per Iec 61000-45, Driver Efficiency 85%,Thd 10% As Per Iec 61000-3-2 , P. F.≥0.95, Ip66,Ik-10, Cri 80 , Under Voltage And Over Voltage Protection,Emiemc As Per Cispr-15, Lenses For Beam Angle As Per Iesna Type I/Ii/Iii As Per The Width Of The Road And The Project Requirement., Suitable To Fit In Up To 65Mm Dia Pipe, Life Time (Led,Driver & Electrical Circuitry) Of Minimum 50000 Burning Hours With 70% Of Initial Lumen Maintained Till Life Ends As Per Lm80 Extrapolation Ies Tm-21-11 Report , Cct 3000°K / 4000°K / 5700°K /6000°K/6500°K (As Per Ansi Bin) , Sdcm(Standard Deviation Color Matching) 5, Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Relevant Bis Standard Complete In All Respect I/C Connections With 1.5 Sq Mm Frls, Pvc Insulated Copper Conductor Single Core Cable And Earthing Etc. As Required With Minimum 5 Year Oem Warranty. System Lumen Efficacy 135 Lm/Watt Output . Lm79 & Lm80 Test Report From Nabl Lab For All Testing Required For Led Fixtures As Per Bis Shall Be Submitted. Shape Size And Cct Shall Be As Approved By Engineer-In-Charge As Per Requirement. (Thermal Management: Heat Sink Of Aluminum Housing Such That Led Junction Temperature Shall Not Rise Above 90°C).72 Watt , Led Street Light Fixture, Powder Coated Pressure Die Cast Aluminum Body (System Lumen Efficacy 135 Lm/Watt) Supplying, Installation, Testing & Commissioning Of Street Light Led Fixture, Powder Coated Pressure Die Cast Aluminum Body With Built In Or Separate Driver As Per The Requirement With Driver Efficiency 85%, Input Voltage: 140-270 Volt Ac, Freq 50/60 Hz, Operating Temp Range -15 Deg To 50 Deg Centigrade, Internal Surge Protection Of 5 Kv L,N,E As Per Iec 61000-45, Driver Efficiency 85%,Thd 10% As Per Iec 61000-3-2 , P. F.≥0.95, Ip66,Ik-10, Cri 80 , Under Voltage And Over Voltage Protection,Emiemc As Per Cispr-15, Lenses For Beam Angle As Per Iesna Type I/Ii/Iii As Per The Width Of The Road And The Project Requirement., Suitable To Fit In Up To 65Mm Dia Pipe, Life Time (Led,Driver & Electrical Circuitry) Of Minimum 50000 Burning Hours With 70% Of Initial Lumen Maintained Till Life Ends As Per Lm80 Extrapolation Ies Tm-21-11 Report , Cct 3000°K / 4000°K / 5700°K /6000°K/6500°K (As Per Ansi Bin) , Sdcm(Standard Deviation Color Matching) 5, Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Relevant Bis Standard Complete In All Respect I/C Connections With 1.5 Sq Mm Frls, Pvc Insulated Copper Conductor Single Core Cable And Earthing Etc. As Required With Minimum 5 Year Oem Warranty. System Lumen Efficacy 135 Lm/Watt Output . Lm79 & Lm80 Test Report From Nabl Lab For All Testing Required For Led Fixtures As Per Bis Shall Be Submitted. Shape Size And Cct Shall Be As Approved By Engineer-In-Charge As Per Requirement. (Thermal Management: Heat Sink Of Aluminum Housing Such That Led Junction Temperature Shall Not Rise Above 90°C).100 Watt , Led Flood Light, Powder Coated Pressure Die Cast Aluminum (System Lumen Efficacy 135 Lm/Watt) Supplying, Installation, Testing & Commissioning Of Flood Light, Powder Coated Pressure Die Cast Aluminum Body With Built In Or Separate Driver As Per The Requirement With Driver Efficiency 85%, Input Voltage: Input Voltage: 140-270 Volt Ac, Freq 50/60 Hz, Operating Temp Range -15 Deg To 50 Deg Centigrade, Internal Surge Protection Of 5 Kv L,N,E As Per Iec 61000-4-5, Driver Efficiency 85%,Thd 10% As Per Iec 61000-3-2 , P. F.≥0.95, Ip-66,Ik-10, Cri 80 , Under Voltage And Over Voltage Protection, Emi-Emc As Per Cispr-15, Lenses For Beam Angle 30 Deg120deg As Per The Application And The Project Requirement Deg., Suitable Tilt Able Fitting, Life Time (Led,Driver & Electrical Circuitry) Of Minimum 50000 Burning Hours With 70% Of Initial Lumen Maintained Till Life Ends As Per Lm80 Extrapolation Ies Tm-21-11 Report , Cct 3000°K / 4000°K / 5700°K /6000°K/6500°K (As Per Ansi Bin) Sdcm(Standard Deviation Color Matching) 5, Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Relevant Bis Standard Complete In All Respect I/C Connections With 1.5 Sq Mm Frls, Pvc Insulated Copper Conductor Single Core Cable And Earthing Etc. As Required With Minimum 5 Year Oem Warranty. System Lumen Efficacy 135 Lm/Watt Output . Lm79 & Lm80 Test Report From Nabl Lab For All Testing Required For Led Fixtures As Per Bis Shall Be Submitted. Shape Size And Cct Shall Be As Approved By Engineer-In-Charge As Per Requirement. (Thermal Management: Heat Sink Of Aluminum Housing Such That Led Junction Temperature Shall Not Rise Above 90°C). 100W , Providing And Laying In Position M25 Grade Reinforced Cement Concrete Foundation Of Size 600 Mm(L) X 600 Mm Wide And 1200 Mm Deep I/C Excavation Of Earth, Providing Cutting, Bending And Placing In Position, Rewinforcement Of Cold Twisted Bars Of 12 Mm Dia -1160Mm Long (Approx.) - 8 Nos.And Reinforcement Of Cold Twisted Bar Of 8 Mm Dia - 1600 Mm (Approx.) - 8 Nos. (With 150 Mm Spacing) As Required With Supplying And Positioning Of 4 Nos Foundation Bolts Of Size 20 Mm Dia And 700/750 Mm Long, J Type I/C 2 Nos Template Anchor Plates Of Size 225 Mm X 225Mm X 3 Mm And Providing 63 Mm Dwc Hdpe Pipe For Cable Entry & Exit As Required For 7Mtr And 8 Mtr Pole , Fabrication, Supply & Erection Of 8.0 Mtr Height, Minimum 3 Mm Thick, Bottom Dia Of 130Mm & Top Dia Of 70Mm, Base Plate Of Size 225 X 225 X 12 Mm Thick Flange Mounted Hot Dip Galvanized Octagonal Pole Made From Ht Steel Plate, Window With Flash Cover With Full Vertical Window Cover At Appropriate Height From The Base Plate On Existing Cement Concrete Pedestal As Required. L/C Supplying And Fixing Of 6 Mm Thick Laminated Mounted Sheet Inside The Window And L/C Providing And Welding 3 Nos. Gi Strips 4 Mm Thick Of Suitable Length And Having Suitable Size Tapped Holes As Reqd, Terminal Block Suitable For 25 Sq Mm Conductor - 4 Nos. & Shorting Links On Din Channel L/C Providing And Fixing Din Channel Of Suitable Length, 6 Amp. Spmcb C Curve Characteristics, Earth Stud, Cable Support Clamp Suitable For Upto 4X25 Sqmm Cable. Logo/Name Of Manufacturer Shall Be Either Embossed Or Rivited Plate On The Pole. Galvanization As Per Relevant Is Code Etc As Required , Supply Installation Testing and Commissioning of 25 Watt Led Ip65 Post Top Fitting Made Of Die Cast Aluminium Spigot Spun Aluminium Powder Coated Top Cover And Clear Acrylic Diffuser With High Voltage Protection Low Power Led'S Connected In Series And Parallel Combination With Better Heat Sink Arrangement Input Voltage 160-260 Volts Ac, 50 Hz Ac Supply Power Factor ≫0.95, Luminious Efficacy ≫100 Lumens/Watt, Cct 5700&Deg;K &Plusmn;300&Deg;K, Surge Protection Not Less Than 10Kv Complete Etc As Requred. , Fabrication, Supplying And Fixing Class B Galvanised Single Overhang Arm Bracket Made Out Of 250Mm Long Galvanised Top Tube With Cap And 1000Mm Long 32 Mm Dia Galvanised Pipe With Tightening Bolts Complete As Required , Supply Of 14/15 Watt Led Retrofit Lamp Suitable For B22 Holder , Supplying And Fixing Brass Batten/ Angle Holder Including Connection Etc. As Required.

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 21-05-2026 EEE/SZ/26-27/Nit/10 itemNo.1 Other 23-05-2026

Key Dates

Publish Date 21-05-2026
Last Date of Bid Submission 23-05-2026

Contact Information

Company Name Municipal Corporation Of Delhi
Contact Person Atul Bhardwaj
Address Hauz Khas

BOQ Items

Name of Work:-
Sl. No. Item Description
1Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required
2Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
3Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
4Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm
5Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35 sq. mm
6Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 1.5 sq. mm
7Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 5 x 1.5 sq. mm
8Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.in the existing trench, complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
9Supplying and fixing of light class GI pipe of 50 mm dia (nominal) 3 meters length along the pole for protection of under ground cable as required.
10Excavation of the cable trenches in hard rock not exceeding 1.5 meters in width, and lift upto 1.5 meters, including getting out the excavated soil and disposal of excavated soil as directed within a lead of 50 meters.
11Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 Cement : 3coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
12Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C X 6 sqmm
13Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C X 10 qmm
14LED Street light fixture, powder coated pressure die cast aluminum body (System lumen efficacy >135 lm/Watt) Supplying, installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-45, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP66,IK-10, CRI >80 , under voltage and over voltage protection,EMIEMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).72 watt
15LED Street light fixture, powder coated pressure die cast aluminum body (System lumen efficacy >135 lm/Watt) Supplying, installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-45, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP66,IK-10, CRI >80 , under voltage and over voltage protection,EMIEMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).100 watt
16LED Flood Light, powder coated pressure die cast aluminum (System lumen efficacy >135 lm/Watt)Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >80 , under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 100W
17Providing and laying in position M25 grade reinforced cement concrete foundation of size 600 mm(L) x 600 mm wide and 1200 mm deep i/c excavation of earth, providing cutting, bending and placing in position, rewinforcement of cold twisted bars of 12 mm dia -1160mm long (approx.) - 8 nos.and reinforcement of cold twisted bar of 8 mm dia - 1600 mm (approx.) - 8 nos. (with 150 mm spacing) as required with supplying and positioning of 4 nos foundation bolts of size 20 mm dia and 700/750 mm long, J type i/c 2 nos template anchor plates of size 225 mm x 225mm x 3 mm and providing 63 mm DWC HDPE pipe for cable entry & exit as required for 7mtr and 8 mtr pole
18Fabrication, supply & erection of 8.0 mtr height, minimum 3 mm thick, bottom dia of 130mm & top dia of 70mm, base plate of size 225 x 225 x 12 mm thick flange mounted hot dip galvanized octagonal pole made from HT steel plate, window with flash cover with full vertical window cover at appropriate height from the base plate on existing cement concrete pedestal as required. l/c supplying and fixing of 6 mm thick laminated mounted sheet inside the window and l/c providing and welding 3 nos. GI strips 4 mm thick of suitable length and having suitable size tapped holes as reqd, terminal block suitable for 25 sq mm conductor - 4 nos. & shorting links on DIN channel l/c providing and fixing DIN channel of suitable length, 6 Amp. SPMCB 'C' Curve characteristics, earth stud, cable support clamp suitable for upto 4x25 sqmm cable. Logo/Name of manufacturer shall be either embossed or Rivited plate on the pole. Galvanization as per relevant IS code etc as required
19SITC of 25 watt LED IP65 post top fitting made of die cast aluminium spigot spun aluminium powder coated top cover and clear acrylic diffuser with high voltage protection low power LED's connected in series and parallel combination with better heat sink arrangement input voltage 160-260 volts AC, 50 Hz AC Supply power factor >0.95, luminious efficacy >100 lumens/watt, CCT 5700°K ±300°K, Surge protection not less than 10KV complete etc as requred.
20Fabrication, supplying and fixing class B galvanised single overhang arm bracket made out of 250mm long galvanised top tube with cap and 1000mm long 32 mm dia galvanised pipe with tightening bolts complete as required
21Supply of 14/15 Watt LED retrofit lamp suitable for B22 holder
22Supplying and fixing brass batten/ angle holder including connection etc. as required. Please Enable Macros to View BoQ information

Other Detail

Information Source https://etenders.gov.in/eprocure/app
Download FileName File Description File Size
Download atofcondition.pdf Tender Documents 0 KB
Download BOQ_324664.xls Tender Documents 0 KB
Download cba96ed5-0c35-447e-bd85-2ce20288ca40.html Tender Documents 0 KB
Download Tendernotice_1.pdf Tender Documents 0 KB
Download Tendernotice_2.pdf Tender Documents 0 KB
Download Tendernotice_3.pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.