Indian Tenders

Tender Notice

TDR 55581892
Tendering Authority Power Development Department
Tender No EDbpr08of2026-27
Tender ID 2026_PDD_310312_1
Tender Brief Corrigendum : Tender For Stage Contract For Execution Of Various Electrical, Maintenance, And Allied Works Within The Jurisdiction Of Electric Division Bandipora For The Financial Year 2026-27 Or Till The Next Stage Gets Finalised.
City Bandipora
State Jammu And Kashmir
Document Fees INR 500 /-
EMD INR 50000.0 /-
Tender Value Refer document
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Stage Contract For Execution Of Various Electrical, Maintenance, And Allied Works Within The Jurisdiction Of Electric Division Bandipora For The Financial Year 2026-27 Or Till The Next Stage Gets Finalised.

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 16-06-2026 Date Extension2 Date 23-06-2026
2 09-06-2026 Date Extension Date 16-06-2026
3 09-06-2026 Date Extension Date 16-06-2026

Key Dates

Publish Date 16-06-2026
Last Date of Bid Submission 23-06-2026
Tender Opening Date 23-06-2026

Contact Information

Company Name Power Development Department
Contact Person Executive Engineer ED Bandipora
Address Office of the Executive Engineer ED BANDIPORA, Block C, Mini Secretariat Complex BANDIPORA

BOQ Items

Name of Work:- Stage Contract for Execution of Various Electrical, Maintenance, and Allied Works within the Jurisdiction of Electric Division Bandipora for the Financial Year 2026–27 or till the next stage gets finalised.
Sl. No. Item Description
1SITC/ITC for below mentioned items ( For ESD Bandipora and Kaloosa Only)
2Supply, Erection , testing & commissioning of S.T Pole 11mtr. Long SP-56 with base plate & cap for HT. Strictly as per REC standards. (The job includes cement botomming, painting and earthing as per REC Standard/KPDCL Approved Drawings)
3Supply, Erection, testing & commissioning of S.T Pole 9mtr Long SP-33 with base plate & cap for HT. Strictly as per REC standards. (The job includes cement botomming, painting and earthing as per REC Standard/KPDCL Approved Drawings)
4Erection, testing & commissioning of S.T Pole 8/9/11mtr Long steel tubular pole including its carriage from Divisisonal Store to Site (The job includes cement botomming, painting and earthing as per REC Standard/KPDCL Approved Drawing)(Only ST Pole to be provided by KPDCL and has to be lifted from Store/Substores KPDCL and has to be lifted from stores bandipora)
5Supply, Erection, testing & commissioning of S.T Pole 8mtr Long SP-15 with base plate & cap for LT. Strictly as per REC standards(The job includes cement botomming, painting and earthing as per REC Standard/KPDCL Approved Drawing)
6Supply, Laying, stringing, tensioning & binding etc of ACSR 100 mmsq (Dog) Conductor
7Laying, stringing, tensioning & binding of ACSR 100mmsq (Dog) Conductor including its carriage from Divisisonal Store to Site
8Supply, Laying, stringing, tensioning & binding etc of ACSR 50mmsq (Rabbit) Conductor
9Laying, stringing, tensioning & binding of ACSR 50mmsq (Rabbit) Conductor including its carriage from Divisisonal Store to Site
10Supply, Laying, stringing, tensioning & binding of ACSR 30mmsq (Weasal) Conductor
11Laying, stringing, tensioning & binding of ACSR 30mmsq (Weasal) Conductor including its carriage from Divisisonal Store to Site
12Providing & fixing of GI Channel/Angle/Flat/v-cross armof sizes including clamps, nuts and bolts
13Fixing of GI Channel/Angle/Flat/ v-cross arm of sizes including clamps, nuts and bolts (material to be lifted from Stores/Sub-stores)
14Supplying and fixing of pole Earthing Complete by GI Pipe 40 mm or GI rod 20 mm 2.5 mtr long through GI Strip(25x3 mm) or GI Wire 8 SWG for HT/LT pole, 1.2m away from the pole
15Fixing of pole Earthing Complete by GI Pipe 40 mm or GI rod 20 mm 2.5 mtr long through GI Strip(25x3 mm) for HT/LT pole, 1.2M away from the pole (material to be lifted from Stores/Sub-stores)
16SITC of 11 kV Isolator, Double Break,3-pole, 630Amp, horizontal mounting Type, with Earth Switch complete with GI, Clamps ,Nuts and Bolts etc(To be installed on existing DP Structure)
17Installation of 11 kV Isolator, Double Break,3-pole, 630Amp, horizontal mounting Type, with/without out Earth Switch complete with GI, Clamps Nuts and Bolts etc((To be installed on existing DP Structure)(material to be lifted from Stores/Sub-stores)
18Supply,fixing, testing & commissioning of 11KV HG Fuse Set (polymer )as per IS Standards
19Supply,fixing, testing & commissioning of 11 kV Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
20Supply,fixing, testing & commissioning of 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
21Supply,fixing, testing & commissioning of 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm complete Set
22Supply,fixing, testing & commissioning of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm with pin, bolt, washer etc complete.
23Fixing, testing & commissioning of 11KV Pin Insulators (polymer) 45 KN with GI pins complete. (material to be lifted from Stores/Sub-stores)
24Carriage, Installation, testing & commisioing of 25/63/100 kVA 11/0.433 KV 3-Phase dully Oil Filled Distribution Transformer from Divisional stores upto site within the jurisdiction of ED Bandipora.
25Carriage, Installation, testing & commisioing of 200/250/300 kVA 11/0.433 KV 3-Phase dully Oil Filled Distribution Transformer from Divisional stores upto site within the jurisdiction of ED Bandipora.
26Providing, Fixing of GI nuts and bolts, .
27Fixing of nuts and bolts for fixing of x-arms,v cross arms, and other accessories. (material to be lifted from Stores/Sub-stores)
28Painting of poles with one coat of red oxide and two coats of Alm paint. Complete job icluding the cost of paint and red oxide
29Supply, Fixing, of LT Shackle insuators with GI Mukey-clamps(50x6mm) icnluding GI nuts and bolts.
30SITC of LT Line Spacers(3p4W)
31Fixing, of LT Shackle insuators with Mukhi-clamps nuts and bolts. (material to be lifted from Stores/Sub-stores)
32Dismantling of ST 8Mtr Long Poles including its carriage to Divisional Stores Bandipora (complete job)
33Dismantling of ST 9Mtr Long Poles including its carriage to Divisional Stores (complete job)
34Dismantling of PCC Poles including its carraige and safe dumping (complete job)
35Dismantling & Re-erection of ST 8Mtr. Long Poles(Full job including cement botomming,earthing etc as per KPDCL/REC approved drawing)
36Dismantling & Re-erection of ST 9/11Mtr. Long Poles (Full job including cement botomming,earthing etc as per KPDCL/REC approved drawing)
37Dismantling of ACSR 30mmsq including its carriage to Divisional Stores (complete job)
38Dismantling of ACSR 50/100 mmsq including its carriage to Divisional Stores Bandipora (complete job)
39Dismantling & Re-laying of ACSR 30mmsq at site
40Dismantling & Re-laying of ACSR 50mmsq at site
41Re-Stringing of loose/fallen Conductor (50mmsq)
42Re-Stringing of loose/fallen Conductor (30mmsq)
43Branch cutting of trees for route clearance for minimising frquency of faults.
44Unloading of 16kVA/25KVA distribution transformer
45Loading of 16kVA/25KVA distribution transformer
46Unloading of 63kVA/100KVA distribution transformer
47Loading of 63kVA/100KVA distribution transformer
48Unloading of 200kVA/250kVA/300KVA distribution transformer
49Loading of 200kVA/250kVA/300KVA distribution transformer
50Mounting/Unmounting of Distribution transformer 63/100/250KVA using Hydraulic Crane where lifting/installation in not possible manually.
51Unloading of ST 11Mtr/9Mtr/8Mtr. Long Poles in Divisional Stores/sub store etc
52Loading/Shifting of ST 11Mtr/9Mtr/8Mtr. Long Poles in Divisional Stores/sub store etc
53Supply and fixing of Earthing of sub station-Excavation of earth pit of dia 650 mm & depth 3000mm,installation of earthing pipe of 40mm Nominal bore and 4mm wall thickness and length 2.5 mtr long as per IS 1239 GI strip for neutral earthing of size25x3mm for connection of transformer body,GO set and lighting arrestor as per IS 2629/85,GI nuts and Bolts,refilled with earth enhancement material and earth chamber made of brick masonary with RCC slab cover.
54Supply, installation , testing & commissioning of Single Core XPLE, FRLS Cable 70 mmsq Unarmoured HAVELLS/KEI/POLYCAB/GLOSTER/FINOLEX/ANCHOR/PLAZA
55Supply, installation , testing & commissioning of Single Core XPLE, FRLS Cable 120 mmsq Unarmoured HAVELLS/KEI/POLYCAB/GLOSTER/FINOLEX/ANCHOR/PLAZA
56Supply, installation , testing & commissioning of Single Core XPLE, FRLS Cable 300 mmsq Unarmoured HAVELLS/KEI/POLYCAB/GLOSTER/FINOLEX/ANCHOR/PLAZA
57Providing, Installation, testing & commisioning of 3-Phase 4-wire Prodigy Meter (40 -200A), including suitable stand/clamps using channels and Canopy to protect the same from Adverse Weather Conditions (Complete)
58Supply, laying, testing & commissiong of 120mmsq AB (HT Cable) (3x120+1x95mmsq) XLPE (11kV , 3 x 1Core + Earth) of standard make conforming to IS; 8130-1894, IS; 398(Part-IV) - 1994, IS:7098 (Part II) - 2011 & IS; 5831-1984 with upto date amendments if any.
59Supply, laying, testing & commissiong of 50mmsq AB (HT Cable) (3x50+1x35mmsq) XLPE (11kV , 3 x 1Core + Earth) of standard make conforming to IS; 8130-1894, IS; 398(Part-IV) - 1994, IS:7098 (Part II) - 2011 & IS; 5831-1984 with upto date amendments if any.
60Supply, laying, testing & commissiong of 35mmsq AB (HT Cable) (3x35+1x35mmsq) XLPE (11kV , 3 x 1Core + Earth) of standard make conforming to IS; 8130-1894, IS; 398(Part-IV) - 1994, IS:7098 (Part II) - 2011 & IS; 5831-1984 with upto date amendments if any.
61Laying, testing & commissiong of 120/50/35mmsq AB (HT Cable) (material to be lifted from Stores/Sub-stores)
62Supply, fixing, testing & commissiong of Mid Span Straight through Jointing kit for 11kV AB Cable suitable for AB Cable of standard make and size conforming to the latest IS Standards
63Supply, fixing, testing & commissiong of 11kV Heat Shrinkable Out Door Cable termination Kit for 11kV AB Cable of standard make and size conforming to the latest IS Standards
64Supply, Fixing of ' Suspension Clamps with eye Hook (Complete)' of standard make for AB Cable including strips for fixing on poles of required sizes
65SITC of 120 mm² AB Cable (3x120+1x25+1x95) mm² XLPE (1.1kV, 3+1 C, Al)(Reputed make approved with KPDCL)
66SITC of 50 mm² AB (LT) Cable ( 3 x 50 + 1 x 16 + 1 x 35) mm² XLPE (1.1kV, 3+1 C, Al)(Reputed make approved with KPDCL)
67SITC of 70 mm² AB Cable (3x70+1x16+1x50) mm² XLPE (1.1kV, 3+1 C, Al) (Reputed make approved with KPDCL)
68SITC of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6)mm, nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
69SITC of Insulating Piercing Connectors
70SITC of Straight Through Cable Jointing Kit for LT Cables of various sizes
71SITC of Pole Mount Service connection box for LT ab cable(SMDB)
72Erection/Fixing/Installation of 120/75/50/35 mm² LT AB Cable (material to be lifted from Stores/Sub-stores)
73Erection/Fixing/Installation of Galvanised Stay Set (material to be lifted from Stores/Sub-stores)
74SITC Streight Throught Joint for Single Core HT Cable of various Sizes
75SITC of Outdoor type termination Kit for Single Core HT Cable of various sizes.
76SITC Streight Throught Joint for Three Core HT Cable of various Sizes
77SITC of Outdoor type termination Kit for Three Core HT Cable of various sizes.
78SITC of 11 kV/11 kV THREE CORE,95 mm2 ALUMINIUMCONDUCTOR, XLPE INSULATED, ARMOURED CABLE to be laid in HDPE pipe of appropriate size 1000mm below ground(Cost inclusive of HDPE Pipe to be quoted)
79SITC of 1.1 kV TWO CORE, 50 sqmm ALUMINIUM CONDUCTOR, XLPE INSULATED, ARMOURED CABLES to be laid on ground/on existing poles etc as per site requirement
80Replacement of Filter Papers Rods of Fowler Westrup (india) make, 2400 LPH Model transformer oil filteration machine
81Servicing of Fowler Westrup (india) make, 2400 LPH Model transformer oil filteration machine
82Servicing of 2.4/3.5kVA DG Set Kirloskar Make
83Supply, Installation ,Testing and Commissioning and operation at sites within the jurisdiction of ED Bandipora (by utilizing skilled mechanics) of 2.8KVA Portable Gensets on hire basis(rate per day, fuel to be provided by KPDCL)
84Loading,Carriage to and fro ,Installation ,Testing and Commissioning (by utilizing skilled mechanics) of Portable Gensets (to be provided by the department) from Divisional Stores upto sites within the jurisdiction of ED Bandipora(Rate per day)
85Operation and Maintainence (by utilizing skilled mechanics) of 5/25/62.5/100 KVA Portable Gensets (rate per day)
86Installation, Testing & commisioing of 10/30/40 watt LED lights including bracket , clamps , nuts & bolts of standard make
87Supply, Installation, Testing & commisioing of 20 watt LED light outdoor type including bracket , clamps , nuts & bolts of standard make
88Supply, Installation, Testing & commisioing of 40 watt LED light outdoor type including bracket , clamps , nuts & bolts of standard make
89Supply, Installation, Testing & commisioing of 100 watt LED light outdoor type including bracket , clamps , nuts & bolts of standard make
90Providing, laying of 16mmsq twin core Cable aluminuim conductor FRLS of HAVELLS/KEI/POLYCAB/GLOSTER/FINOLEX/ANCHOR/PLAZA
91Providing, laying of 10mmsq twin core cable aluminuim conductor FRLS of HAVELLS/KEI/POLYCAB/GLOSTER/FINOLEX/ANCHOR/PLAZA
92Providing, laying of 6mmsq twin core cable aluminuim conductor FRLS of HAVELLS/KEI/POLYCAB/GLOSTER/FINOLEX/ANCHOR/PLAZA
93Providing, laying of 1mmsq PVC single core Cu flexible wire coil (90m) of HAVELLS/KEI/POLYCAB/GLOSTER/FINOLEX/ANCHOR/PLAZA
94Providing, laying of 1.5 mmsq PVC single core Cu flexible wire Coil(90m) of HAVELLS/KEI/POLYCAB/GLOSTER/FINOLEX/ANCHOR/PLAZA
95Providing, laying of 2.5 mmsq PVC single core Cu flexible wire Coil(90m) of HAVELLS/KEI/POLYCAB/GLOSTER/FINOLEX/ANCHOR/PLAZA
96Providing, laying of 4 mmsq PVC single core Cu flexible wire Coil(90m) of HAVELLS/KEI/POLYCAB/GLOSTER/FINOLEX/ANCHOR/PLAZA
97Providing, laying of 6 mmsq PVC single core Cu flexible wire Coil(90m) of HAVELLS/KEI/POLYCAB/GLOSTER/FINOLEX/ANCHOR/PLAZA
98Supply, Installation, Testing & commisioing of 5Amp Switch Socket Combine
99Supply,Installation, Testing & commisioing of 32 Amp with DP Switch Socket Combine
100Supply, Installation, Testing & commisioing of LED Bulbs 10W with pendent holders
101Supply, installation, testing & commissioing of LT Fuse set on 8 No 10kV Post Insulators with direct link of 8x5mm Al flat for Neutral along with clamps and thimbles, nuts and bolts etc as per approved drawings of KPDCL
102Supply, Installation, Testing and Commissioning of 0.5 Sq.mm 2 Core Flexible Twisted Wire Red and Black (90 m)
103Supply and Installation of 4Pole 100Amp, 415v, 50Hz, Off load Change over switch conforming to latest IS standards of reputed brands like havells, L&T etc.
104Supply and Installation of MS Kiosk for Housing of Changeover Switches
105Unloading of line material & workshop material like ACSR (30mmsq, 50mmsq, 100mmsq, DPC, T.Oil (barrels) , GI Wire, link sets, DO sets, Nuts & bolts, channel iron of sizes, Disc Sets, braces of sizes, bush rods, Alm. Strips, insulators, Etc. from Divisional stores
106Loading/shifting of line material & workshop material like ACSR (30mmsq, 50mmsq, 100mmsq, DPC, T.Oil (barrels) , GI Wire, link sets, DO sets, Nuts & bolts, channel iron of sizes, Disc Sets, braces of sizes, bush rods, Alm. Strips, insulators, Etc. from Divisional stores
107Providing and Laying in position cement concrete ( PCC)(M10 Grade) including centering, shuttering, carriage of material, curing etc
108Providing and Laying in position reignforced cement concrete ( RCC)(M20 Grade) including centering, shuttering, carriage of material, curing etc as per drawing(Rebar reignforcement to be provided by the department)
109Providing and applying cement plaster (1:4 mix) 12mm thick on walls including surface preparation, scaffolding, curing, and all necessary tools and materials complete as per specifications.
110Relaying/Restringing of loose /fallen / low hanging LT/HT AB Cable
111Installation of Consumer Metres (Complete Job including connection etc ) (material to be lifted from Stores/Sub-stores)
112Shifting of Metres from bare conductor to AB Cable or new line (Complete Job including connection etc )
113SITC/ITC for below mentioned items( for ESD Gurez Only)
114Supply, Erection , testing & commissioning of S.T Pole 11mtr. Long SP-56 with base plate & cap for HT. Strictly as per REC standards. (The job includes cement botomming, painting and earthing as per REC Standard/KPDCL Approved Drawings)
115Supply, Erection, testing & commissioning of S.T Pole 9mtr Long SP-33 with base plate & cap for HT. Strictly as per REC standards. (The job includes cement botomming, painting and earthing as per REC Standard/KPDCL Approved Drawings)
116Erection, testing & commissioning of S.T Pole 8/9/11mtr Long steel tubular pole including its carriage from Divisisonal Store to Site (The job includes cement botomming, painting and earthing as per REC Standard/KPDCL Approved Drawing)(Only ST Pole to be provided by KPDCL and has to be lifted from Store/Substores KPDCL and has to be lifted from stores bandipora)
117Supply, Erection, testing & commissioning of S.T Pole 8mtr Long SP-15 with base plate & cap for LT. Strictly as per REC standards(The job includes cement botomming, painting and earthing as per REC Standard/KPDCL Approved Drawing)
118Supply, Laying, stringing, tensioning & binding etc of ACSR 100 mmsq (Dog) Conductor
119Laying, stringing, tensioning & binding of ACSR 100mmsq (Dog) Conductor including its carriage from Divisisonal Store to Site
120Supply, Laying, stringing, tensioning & binding etc of ACSR 50mmsq (Rabbit) Conductor
121Laying, stringing, tensioning & binding of ACSR 50mmsq (Rabbit) Conductor including its carriage from Divisisonal Store to Site
122Supply, Laying, stringing, tensioning & binding of ACSR 30mmsq (Weasal) Conductor
123Laying, stringing, tensioning & binding of ACSR 30mmsq (Weasal) Conductor including its carriage from Divisisonal Store to Site
124Providing & fixing of GI Channel/Angle/Flat/v-cross armof sizes including clamps, nuts and bolts
125Fixing of GI Channel/Angle/Flat/ v-cross arm of sizes including clamps, nuts and bolts (material to be lifted from Stores/Sub-stores)
126Supplying and fixing of pole Earthing Complete by GI Pipe 40 mm or GI rod 20 mm 2.5 mtr long through GI Strip(25x3 mm) or GI Wire 8 SWG for HT/LT pole, 1.2m away from the pole
127Fixing of pole Earthing Complete by GI Pipe 40 mm or GI rod 20 mm 2.5 mtr long through GI Strip(25x3 mm) for HT/LT pole, 1.2M away from the pole (material to be lifted from Stores/Sub-stores)
128SITC of 11 kV Isolator, Double Break,3-pole, 630Amp, horizontal mounting Type, with Earth Switch complete with GI, Clamps ,Nuts and Bolts etc(To be installed on existing DP Structure)
129Installation of 11 kV Isolator, Double Break,3-pole, 630Amp, horizontal mounting Type, with/without out Earth Switch complete with GI, Clamps Nuts and Bolts etc((To be installed on existing DP Structure)(material to be lifted from Stores/Sub-stores)
130Supply,fixing, testing & commissioning of 11KV HG Fuse Set (polymer )as per IS Standards
131Supply,fixing, testing & commissioning of 11 kV Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
132Supply,fixing, testing & commissioning of 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
133Supply,fixing, testing & commissioning of 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm complete Set
134Supply,fixing, testing & commissioning of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm with pin, bolt, washer etc complete.
135Fixing, testing & commissioning of 11KV Pin Insulators (polymer) 45 KN with GI pins complete. (material to be lifted from Stores/Sub-stores)
136Carriage, Installation, testing & commisioing of 25/63/100 kVA 11/0.433 KV 3-Phase dully Oil Filled Distribution Transformer from Divisional stores upto site within the jurisdiction of ED Bandipora.
137Carriage, Installation, testing & commisioing of 200/250/300 kVA 11/0.433 KV 3-Phase dully Oil Filled Distribution Transformer from Divisional stores upto site within the jurisdiction of ED Bandipora.
138Providing, Fixing of GI nuts and bolts, .
139Fixing of nuts and bolts for fixing of x-arms,v cross arms, and other accessories. (material to be lifted from Stores/Sub-stores)
140Painting of poles with one coat of red oxide and two coats of Alm paint. Complete job icluding the cost of paint and red oxide
141Supply, Fixing, of LT Shackle insuators with GI Mukey-clamps(50x6mm) icnluding GI nuts and bolts.
142SITC of LT Line Spacers(3p4W)
143Fixing, of LT Shackle insuators with Mukhi-clamps nuts and bolts. (material to be lifted from Stores/Sub-stores)
144Dismantling of ST 8Mtr Long Poles including its carriage to Divisional Stores Bandipora (complete job)
145Dismantling of ST 9Mtr Long Poles including its carriage to Divisional Stores (complete job)
146Dismantling of PCC Poles including its carraige and safe dumping (complete job)
147Dismantling & Re-erection of ST 8Mtr. Long Poles(Full job including cement botomming,earthing etc as per KPDCL/REC approved drawing)
148Dismantling & Re-erection of ST 9/11Mtr. Long Poles (Full job including cement botomming,earthing etc as per KPDCL/REC approved drawing)
149Dismantling of ACSR 30mmsq including its carriage to Divisional Stores (complete job)
150Dismantling of ACSR 50/100 mmsq including its carriage to Divisional Stores Bandipora (complete job)
151Dismantling & Re-laying of ACSR 30mmsq at site
152Dismantling & Re-laying of ACSR 50mmsq at site
153Re-Stringing of loose/fallen Conductor (50mmsq)
154Re-Stringing of loose/fallen Conductor (30mmsq)
155Branch cutting of trees for route clearance for minimising frquency of faults.
156Unloading of 16kVA/25KVA distribution transformer
157Loading of 16kVA/25KVA distribution transformer
158Unloading of 63kVA/100KVA distribution transformer
159Loading of 63kVA/100KVA distribution transformer
160Unloading of 200kVA/250kVA/300KVA distribution transformer
161Loading of 200kVA/250kVA/300KVA distribution transformer
162Mounting/Unmounting of Distribution transformer 63/100/250KVA using Hydraulic Crane where lifting/installation in not possible manually.
163Unloading of ST 11Mtr/9Mtr/8Mtr. Long Poles in Divisional Stores/sub store etc
164Loading/Shifting of ST 11Mtr/9Mtr/8Mtr. Long Poles in Divisional Stores/sub store etc
165Supply and fixing of Earthing of sub station-Excavation of earth pit of dia 650 mm & depth 3000mm,installation of earthing pipe of 40mm Nominal bore and 4mm wall thickness and length 2.5 mtr long as per IS 1239 GI strip for neutral earthing of size25x3mm for connection of transformer body,GO set and lighting arrestor as per IS 2629/85,GI nuts and Bolts,refilled with earth enhancement material and earth chamber made of brick masonary with RCC slab cover.
166Supply, installation , testing & commissioning of Single Core XPLE, FRLS Cable 70 mmsq Unarmoured HAVELLS/KEI/POLYCAB/GLOSTER/FINOLEX/ANCHOR/PLAZA
167Supply, installation , testing & commissioning of Single Core XPLE, FRLS Cable 120 mmsq Unarmoured HAVELLS/KEI/POLYCAB/GLOSTER/FINOLEX/ANCHOR/PLAZA
168Supply, installation , testing & commissioning of Single Core XPLE, FRLS Cable 300 mmsq Unarmoured HAVELLS/KEI/POLYCAB/GLOSTER/FINOLEX/ANCHOR/PLAZA
169Providing, Installation, testing & commisioning of 3-Phase 4-wire Prodigy Meter (40 -200A), including suitable stand/clamps using channels and Canopy to protect the same from Adverse Weather Conditions (Complete)
170Supply, laying, testing & commissiong of 120mmsq AB (HT Cable) (3x120+1x95mmsq) XLPE (11kV , 3 x 1Core + Earth) of standard make conforming to IS; 8130-1894, IS; 398(Part-IV) - 1994, IS:7098 (Part II) - 2011 & IS; 5831-1984 with upto date amendments if any.
171Supply, laying, testing & commissiong of 50mmsq AB (HT Cable) (3x50+1x35mmsq) XLPE (11kV , 3 x 1Core + Earth) of standard make conforming to IS; 8130-1894, IS; 398(Part-IV) - 1994, IS:7098 (Part II) - 2011 & IS; 5831-1984 with upto date amendments if any.
172Supply, laying, testing & commissiong of 35mmsq AB (HT Cable) (3x35+1x35mmsq) XLPE (11kV , 3 x 1Core + Earth) of standard make conforming to IS; 8130-1894, IS; 398(Part-IV) - 1994, IS:7098 (Part II) - 2011 & IS; 5831-1984 with upto date amendments if any.
173Laying, testing & commissiong of 120/50/35mmsq AB (HT Cable) (material to be lifted from Stores/Sub-stores)
174Supply, fixing, testing & commissiong of Mid Span Straight through Jointing kit for 11kV AB Cable suitable for AB Cable of standard make and size conforming to the latest IS Standards
175Supply, fixing, testing & commissiong of 11kV Heat Shrinkable Out Door Cable termination Kit for 11kV AB Cable of standard make and size conforming to the latest IS Standards
176Supply, Fixing of ' Suspension Clamps with eye Hook (Complete)' of standard make for AB Cable including strips for fixing on poles of required sizes
177SITC of 120 mm² AB Cable (3x120+1x25+1x95) mm² XLPE (1.1kV, 3+1 C, Al)(Reputed make approved with KPDCL)
178SITC of 50 mm² AB (LT) Cable ( 3 x 50 + 1 x 16 + 1 x 35) mm² XLPE (1.1kV, 3+1 C, Al)(Reputed make approved with KPDCL)
179SITC of 70 mm² AB Cable (3x70+1x16+1x50) mm² XLPE (1.1kV, 3+1 C, Al) (Reputed make approved with KPDCL)
180SITC of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6)mm, nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
181SITC of Insulating Piercing Connectors
182SITC of Straight Through Cable Jointing Kit for LT Cables of various sizes
183SITC of Pole Mount Service connection box for LT ab cable(SMDB)
184Erection/Fixing/Installation of 120/75/50/35 mm² LT AB Cable (material to be lifted from Stores/Sub-stores)
185Erection/Fixing/Installation of Galvanised Stay Set (material to be lifted from Stores/Sub-stores)
186SITC Streight Throught Joint for Single Core HT Cable of various Sizes
187SITC of Outdoor type termination Kit for Single Core HT Cable of various sizes.
188SITC Streight Throught Joint for Three Core HT Cable of various Sizes
189SITC of Outdoor type termination Kit for Three Core HT Cable of various sizes.
190SITC of 11 kV/11 kV THREE CORE,95 mm2 ALUMINIUMCONDUCTOR, XLPE INSULATED, ARMOURED CABLE to be laid in HDPE pipe of appropriate size 1000mm below ground(Cost inclusive of HDPE Pipe to be quoted)
191SITC of 1.1 kV TWO CORE, 50 sqmm ALUMINIUM CONDUCTOR, XLPE INSULATED, ARMOURED CABLES to be laid on ground/on existing poles etc as per site requirement
192Replacement of Filter Papers Rods of Fowler Westrup (india) make, 2400 LPH Model transformer oil filteration machine
193Servicing of Fowler Westrup (india) make, 2400 LPH Model transformer oil filteration machine
194Servicing of 2.4/3.5kVA DG Set Kirloskar Make
195Supply, Installation ,Testing and Commissioning and operation at sites within the jurisdiction of ED Bandipora (by utilizing skilled mechanics) of 2.8KVA Portable Gensets on hire basis(rate per day, fuel to be provided by KPDCL)
196Loading,Carriage to and fro ,Installation ,Testing and Commissioning (by utilizing skilled mechanics) of Portable Gensets (to be provided by the department) from Divisional Stores upto sites within the jurisdiction of ED Bandipora(Rate per day)
197Operation and Maintainence (by utilizing skilled mechanics) of 5/25/62.5/100 KVA Portable Gensets (rate per day)
198Installation, Testing & commisioing of 10/30/40 watt LED lights including bracket , clamps , nuts & bolts of standard make
199Supply, Installation, Testing & commisioing of 20 watt LED light outdoor type including bracket , clamps , nuts & bolts of standard make
200Supply, Installation, Testing & commisioing of 40 watt LED light outdoor type including bracket , clamps , nuts & bolts of standard make
201Supply, Installation, Testing & commisioing of 100 watt LED light outdoor type including bracket , clamps , nuts & bolts of standard make
202Providing, laying of 16mmsq twin core Cable aluminuim conductor FRLS of HAVELLS/KEI/POLYCAB/GLOSTER/FINOLEX/ANCHOR/PLAZA
203Providing, laying of 10mmsq twin core cable aluminuim conductor FRLS of HAVELLS/KEI/POLYCAB/GLOSTER/FINOLEX/ANCHOR/PLAZA
204Providing, laying of 6mmsq twin core cable aluminuim conductor FRLS of HAVELLS/KEI/POLYCAB/GLOSTER/FINOLEX/ANCHOR/PLAZA
205Providing, laying of 1mmsq PVC single core Cu flexible wire coil (90m) of HAVELLS/KEI/POLYCAB/GLOSTER/FINOLEX/ANCHOR/PLAZA
206Providing, laying of 1.5 mmsq PVC single core Cu flexible wire Coil(90m) of HAVELLS/KEI/POLYCAB/GLOSTER/FINOLEX/ANCHOR/PLAZA
207Providing, laying of 2.5 mmsq PVC single core Cu flexible wire Coil(90m) of HAVELLS/KEI/POLYCAB/GLOSTER/FINOLEX/ANCHOR/PLAZA
208Providing, laying of 4 mmsq PVC single core Cu flexible wire Coil(90m) of HAVELLS/KEI/POLYCAB/GLOSTER/FINOLEX/ANCHOR/PLAZA
209Providing, laying of 6 mmsq PVC single core Cu flexible wire Coil(90m) of HAVELLS/KEI/POLYCAB/GLOSTER/FINOLEX/ANCHOR/PLAZA
210Supply, Installation, Testing & commisioing of 5Amp Switch Socket Combine
211Supply,Installation, Testing & commisioing of 32 Amp with DP Switch Socket Combine
212Supply, Installation, Testing & commisioing of LED Bulbs 10W with pendent holders
213Supply, installation, testing & commissioing of LT Fuse set on 8 No 10kV Post Insulators with direct link of 8x5mm Al flat for Neutral along with clamps and thimbles, nuts and bolts etc as per approved drawings of KPDCL
214Supply, Installation, Testing and Commissioning of 0.5 Sq.mm 2 Core Flexible Twisted Wire Red and Black (90 m)
215Supply and Installation of 4Pole 100Amp, 415v, 50Hz, Off load Change over switch conforming to latest IS standards of reputed brands like havells, L&T etc.
216Supply and Installation of MS Kiosk for Housing of Changeover Switches
217Unloading of line material & workshop material like ACSR (30mmsq, 50mmsq, 100mmsq, DPC, T.Oil (barrels) , GI Wire, link sets, DO sets, Nuts & bolts, channel iron of sizes, Disc Sets, braces of sizes, bush rods, Alm. Strips, insulators, Etc. from Divisional stores
218Loading/shifting of line material & workshop material like ACSR (30mmsq, 50mmsq, 100mmsq, DPC, T.Oil (barrels) , GI Wire, link sets, DO sets, Nuts & bolts, channel iron of sizes, Disc Sets, braces of sizes, bush rods, Alm. Strips, insulators, Etc. from Divisional stores
219Providing and Laying in position cement concrete ( PCC)(M10 Grade) including centering, shuttering, carriage of material, curing etc
220Providing and Laying in position reignforced cement concrete ( RCC)(M20 Grade) including centering, shuttering, carriage of material, curing etc as per drawing(Rebar reignforcement to be provided by the department)
221Providing and applying cement plaster (1:4 mix) 12mm thick on walls including surface preparation, scaffolding, curing, and all necessary tools and materials complete as per specifications.
222Relaying/Restringing of loose /fallen / low hanging LT/HT AB Cable
223Installation of Consumer Metres (Complete Job including connection etc ) (material to be lifted from Stores/Sub-stores)
224Shifting of Metres from bare conductor to AB Cable or new line (Complete Job including connection etc )
225Structural steel work welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.(As per Drawing to be provided by KPDCL)
226Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.0.50 mm thick with zinc coating not less than 275 gram/m2
227Hire Charges for mentioned items (ESD Bandipora Kaloosa and Gurez)
228Hire, operation and maintenance charges for Installation, decorating and operation for 5 days of fancy decoration mala Lights (12m long) (Orange+White+Green) at various places within the jurisdiction of ED Bandipora like Minisectt, Town hall, SP Office, Kangri Chowk , Gurez Bridge, Gurez Mini Sectt. etc
229Hire, operation and maintenance charges for for Installation and commissioning of copper cable 2.5mm sq for 5 days, for providing connection to equipment/lights/buildings etc
230Hire, operation and maintenance charges for for Installation and commissioning of copper cable 1mm sq for 5 days, for providing connection equipment/lights/buildings etc
231Hire, operation and maintenance charges for for 5 days for Standing fan/Ceiling fan 1200mm Sweep with Allied wiring and switches including the Installation and Operation for different events like Independence day etc within the jurisdiction of ED Bandipora
232Hire charges per day for providing of Pick up Truck along with driver including toll taxes, repair and maintenance for transporation of men and material ( as and when required ).(Fuel will be provided by the department as per milage fixed by JKSMGD)
233Charges per day for Operation and Maintainence (by utilizing skilled mechanics) of Portable Gensets of various capacities
234Providing of labours to do non technical manual work (7 Hours per day) Please Enable Macros to View BoQ information

Other Detail

Information Source https://jktenders.gov.in
Download FileName File Description File Size
Download 33a327b8-ad3d-418c-8a85-17e9e84657c9.html Tender Documents 0 KB
Download BOQ_1003970.xls Tender Documents 0 KB
Download sbd08.pdf Tender Documents 0 KB
Download TECHNICALSPECIFICATIONSelectric.pdf Tender Documents 0 KB
Download Tendernotice_1 (10).pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.