| 1 | Dismantling of wall and ceiling boards any thickness including corner fillets. |
| 2 | M&L for GI frame work for seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/intermediate channel 0.9mm thick having equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel at 457mm centre to centre incl 2mm dia G.I. ( upto 1200 mm length ) adjusting level to Purlins/ Rafter. . |
| 3 | M&L 4mm thick non asbestos fibre cement designer building board of size 600X600 fixed or laid/inserted to timber/GI/Aluminium framework fixed in ceiling flat or sloping. |
| 4 | Dismantling AC corrugated /semi corrugated sheets in roof covering complete all as specified and directed. |
| 5 | S & F Pre- painted galvatume aluminum zinc coating GI based corrugated/ Semi Corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. |
| 6 | S & F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. |
| 7 | Demolition of cement concrete (Un reinforced) in ground floors and pavings n. exc 15 CM thickness (below or above ground level) |
| 8 | M & L PCC 1:3:6 type C2 , using 20mm graded aggregates as in 75mm thick plinth protection including bitumen joints in 1.0 Mtr centre to centre as required. |
| 9 | Demolition of Brick work or stone masonry built in cement mortar. |
| 10 | M & L Brick work with sub class `B` bricks straight or covered on plan any radius built in cm 1:6. |
| 11 | Taking down cement plaster on brick or stone wall and any other type of wall finishes incl racking out joints hacking for key, scrubbing down with water and removing the debris from site all as directed. |
| 12 | M & L for rendering in cement mortar (1:6) , 15 mm thick on fair faces of brick work / Concrete /stone surfaces finished even & smooth without using extra cement all as specified and directed by Engr- in - Charge. |
| 13 | M&L for rendering 15 mm thick on fair faces of bricks/concrete surface in cement mortar (1:4) with using on wall finishing the surfaces even and smooth without using extra cement. |
| 14 | M&L for preparation of old painted steel & iron surface of any description n exc 10 cm width or girth when connected with other painting or when painted in different tint applying two coats of synthetic enamel paint over on steel surface. |
| 15 | M&L for preparing newly plastered surfaces applying distemper oil emulsion two coats on 3mm thick wall care putty (in two layers) including priming coats complete . |
| 16 | Complete removal of existing treatment of walls/ ceiling and applying two coats of distemper oil emulsion over 3mm wall care putty (in two layers) including priming coats complete . |
| 17 | M&L for preparing the new plastered surfaces of wall and applyingapplying two coats of cement base paint of any colour over one coat primer complete. |
| 18 | M/L Complete removal of existing treatment on wall and applying two coats of cement base paint of any colour over one coat primer complete |
| 19 | Taking down chowkhats or frame exc 1.50 Sqm but n.exc 4 Sqm each with shutter (without taking of shutter from framed) complete. |
| 20 | Taking down chowkats or frames with shutters (without taking off shutters from the frame) area n’exc1.5 Sqm and removing from site . |
| 21 | M&L Pressed steel frames 105 x 60 mm size of frame for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed |
| 22 | M&L Pressed steel frames 125 x 60 mm size of frame for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed. |
| 23 | M&L Providing, cement concrete type B0 1:2:4 (12.5 mm graded aggreate) in filling of pressed steel frame , coping, fixing of hold fast etc similar work. |
| 24 | Supply and fix for Three Track Sliding powder coated aluminium Window of sizes of Top/Side and Bottom track section of 91.80mm x 31.75mm x 1.20mm thick and Shutter section of sizes 39.40 mm x 17.70mm x 1.20mm thick including joining cleats, beading,locking arrangement, rubber gasket for fixing etc complete with 5.5 mm thick tinted glass & stailness steel wire cloth, 0.36 mm nominal dia of wire and averaging width of aperture 1.40mm and fixed with aluminium wire staples complete . |
| 25 | S&F frame work such as grills, grating etc with ends of bars shouldered and or rivetted or forged into spikes, framed guard bars, barred iron doors, ladders etc and similar wks conforming to Fe-290 Gd E-165 . |
| 26 | Supply and fix forAnodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazingclips, rubber packing, anodisedaluminium snap beading, screwsetc. complete all as specified. |
| 27 | M&L for 30 mm thick flush shutters solid core construction,with block board core and plywood face panels,commercial type on both sides including 1mm thick wood grain printed PVC sheet fixed or laid on to flush door by using rubber based adhesive at site as per specification as per SSR Part-I complete all as specified and directed by Engineer-in-charge. complete all as specified as directed. |
| 28 | S&F 30mm thick 2nd class HW Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats. |
| 29 | S&F solid PVC door frame of size 50mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS Square tube S&F in opening all as shown on drawing and specified. |
| 30 | S&F factory made solid panel PVC door shutter 30 mm thick style consisting of frame made out of MS tubes for top and bottom rails MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheets strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail lock rail and bottom rail on either side and as gap inside for top rail and bottom rail paneling of plain colour PVC sheet to be fitted in the MS frame welded/seated to the stiles and rail with suitable PVC sheet bending and jointed to gather with solvent cement supplying and fixing in the frame at site as per specification and drawing. |
| 31 | M & L applying two coats of synthetic enamel paint over a coat of pink primer incl cleaning for new wooden surface. |
| 32 | S&F mild steel butt hinges cold rolled 100 mm size medium weight. |
| 33 | S&F 250mm Aluminium alloy anodised sliding door with hasp staple (bolts plate type)and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed. |
| 34 | S&F 150mm length of aluminium anodized, barrel tower bolt of extruded section and fixed |
| 35 | S&F aluminum handles, cast type ,anodised 150 mm |
| 36 | Dismantaling floor, hearth or wall tiling, including cement mortar bedding (but not backing ) removing serviciable tile to store & rubbish off the permisses. |
| 37 | M&L for 10 mm thick cement plaster in CM (1:4) for backing of tiles complete all as specified and directed. |
| 38 | M&L for coloured glazed ceramic tiles in vertical surface 300x450x7to8mm thick set and jointed in neat cement slurry & pointed in white or coloured cement to match the surfaces all as specified and directed. |
| 39 | M&L for 15 mm thick screed bed or bedding layer in CM (1:6) complete all as specified. |
| 40 | M&L Non - skid Ceramic jointless tiles of any colour/shade 7 to 8 mm thick area of each tile exceeding 0.11sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the tiles complete. |
| 41 | M&L non skid coloured ceramic tiles 7 to 8 mm thick(square/rectangular) area of each tiles exceeding 0.18 sqm but n.exc 0.38 sqm infloor etc;set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces complete all as specified and directed. |
| 42 | Description all as per Ser Item No 41 as above but on vertical surface as dado/ skirting. |
| 43 | Taking up or down steel tubing and connection of 15 mm bore complete all as specified directed at site. |
| 44 | All as item No above but for 20 mm dia bore pipe. |
| 45 | Supplying and laying 20mm dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. |
| 46 | Supplying and laying 25mm dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. |
| 47 | 20mm CPVC Brass Elbow for 'hot or cold' water supply connection and similar works etc,. |
| 48 | 20mm CPVC Brass Tee for 'hot or cold' water supply connection and similar works etc,. |
| 49 | Disconnecting existing tank of capacity exc.500 & n.exc 1000 ltrs, setting aside lowering if required for repairs cleaning etc and hoisting if required reconnecting and refixing in position |
| 50 | S&F 1000 ltr capacity Rotational moulded polyethylene water storage tank (cylindrical vertical closed top) 3 layered hoisted and fixed in positions all as specified in SSR Part-I,including 20 mm dia of ball valves high pressure of PTMT with epoxy coated aluminium rod &highdensity plastic ball screwed for iron pipe and fixed. |
| 51 | S&F brass CP tubular towel rail 20mm dia D type 60cm long between flanges complete all as specified and as directed by Engr-in-charge. |
| 52 | S&F in repair for 10ltrs capacity flushing cistern PVC low level valve less, symphonic action type flushing cistern white with inlet, ball valve, float and handle including brackets and 32 mm flush pipe of polyethylene complete all as specified and directed. |
| 53 | S&F in repairs stop valve/angle cock fancy type of 15 mm dia cast copper alloy chromium plated screwed down, high pressure, with crutch or butter fly handle long shank and cup screwed both ends for iron pipes or for unions. |
| 54 | S&F in repair 20mm bore stop valves cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe complete all as specified and directed by Engr-in-Charge. |
| 55 | S&F in repair, 15mm bore bib taps cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule complete all as specified and directed. |
| 56 | S&F for 15mm bore stop valve cast copper alloy, fancy type chromium plated with long shank and cup (concealed) screwed down,high pressure with crutch or butterfly handle, screwed both ends for iron pipe complete all as specified and directed. |
| 57 | S&F in repair vitreous china pedastal type watre closet, white (excluding flushing cistern and flush pipe) but including connection to trap, and to flushing pipe, anti-syphonage pipe etc complete and making good to floor. |
| 58 | S&F in EWC sheet cover to match EWC complete. |
| 59 | S&F in repairs Health fauset (ABS Body) mild steel chromium plated suitable for 15mm dia pipe with 1.25 meter long flexible tube and ABS wall hook incl making connections and fixed in position complete in all respect as specified. |
| 60 | S&F for vitrious china wash basin, white flat back size 550 x 400 mm including waste, chain & plug and poreclain stopper and bracket etc. Complete including cutting for and pinning in ends of brackets or errecting bracket and 32mm dia waste fitting brass chromium plated for WHB etc;with long screwed shanks and fly nuts,flange end bedded in red lead cement including 32mm dia waiste pipe fitted complete all as specified and directed. |
| 61 | S&F for pillar tap of 15mm dia bore pipe, fancy type cast copper alloy with capstain head chromium plated with or without lettered “hot or cold” with long screwed shanks and fly nuts screwed for iron pipe fixed complete all as specified and directed. |
| 62 | S&F PVC connection pipe of 15 mm dia and 45 cm long to WHB and flushing cistern complete all as specified and directed. |
| 63 | S&F brass CP tubular towel rail 20mm dia D type 60cm long between flanges complete all as specified and as directed by Engr-in-charge. |
| 64 | S&F in repairs for shower rose chromium plated with or without swivel joints 75 mm dia complete all as specified and directed. |
| 65 | Taking down eaves gutters and rainwater pipes (any size or pattern) including all fittins,heads,shoes,bends,swan-necks,etc including removing from site. |
| 66 | M&L for 110mm bore, PVC (SWR) pipes, single socketed, in any length, with rubber ring joints fixed on walls/floors including PVC clamps fixed to wall properly including fixing of pipe with PCC (1:2:4) complete all as specified & directed. |
| 67 | M&L for 75mm bore, PVC (SWR) pipes, single socketed, in any length, with rubber ring joints fixed on walls/floors including PVC clamps fixed to wall properly including fixing of pipe with PCC (1:2:4) complete all as specified & directed. |
| 68 | S&F PVC (SWR) bends 110 mm bore of any radius all as specified & directed. |
| 69 | S&F PVC (SWR) bends 75 mm bore of any radius all as specified & directed. |
| 70 | S&F PVC (SWR) junction single (singleT) equal or unequal 110mm bore provided with access door all as specified & directed. |
| 71 | S&F 110 mm bore PVC (SWR) vent cowl. |
| 72 | S&F 75 mm dia outlet PVC (SWR) floor trap plain with steel grating including jointing with solvent cement. |
| 73 | S&F 20mm dia Aluminium powder coated as in golden colour finish draft rod complete all as specified and as approved by EIC. |
| 74 | S&F brass chromium plated decorative bracket fixed to wall . |
| 75 | Surface excavation averaging 15 cm deep and not exceeding 30 cm deep and getting out in soft and loose soil. |
| 76 | M&L for 100mm thick cement concrete type D2, (1:4:8) using 40mm stone aggregate as in sub base. |
| 77 | M&L for Spreading and levelling in layers n exc. 25 cm thick including watering and consolidation. |
| 78 | Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment |
| 79 | M&L for pre-cast cement concrete type B1 (1:2:4) using 20mm graded stone aggregate) as in road side kerbs size and shape as specified and directed by Engineer-in-Charge complete. |
| 80 | Taking down carefully copper/aluminium point wiring (light, fan socket or power) complete including fittings & fixtures such as switches, ceiling roses, pendents, regulators etc and making good disturbed surface of walls, floors etc complete all as specified & directed by Engineer-in-charge.Note :- Light fittings shall be measured & paid separately. |
| 81 | M&L for point wiring using approved colour coding as per IS (Red , Black and Green for single phase circuits),with multistranded copper conductor 1.5 sq mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLSH cable 1100 Volts grade, ISI-694 marked with valid CML No.in and including medium grade, PVC consealed conduit of 20mm bore with accessories in wall/roof/floor etc, ISI marked with mild steel/prestressed steel modular sunken/concealed box (with earth dolly) duly painted two coats of anti corrosive paint/aluminium paint over a coat of red oxide primer internally and two coats of black bituminous paint over a coat of red oxide primer externally, 3mm thick plastic laminated sheet top cover for mounting switches, sockets and fan regulators etc, inciuding PVC insulated multistranded copper conductor 1.5 sq mm nominal cross sectional area single core FRLSH cable as earth continuity conductor to common earth and connecting to earth duly completed all as specified and directed by Engr-in-charge for the following . |
| 82 | (a) One light or fan point, controlled by one, one way switch 5 Amps. |
| 83 | (b) One socket out let 3 pin 5 Amps on the same board. |
| 84 | (c) One socket outlet of 3 pin 5 Amp on independent board. |
| 85 | Material and labour for point wiring alongwith earth continuity conductor with 1100 volts grade PVC insulated FRLSH multistranded copper conductor cable 2.5 sqmm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLSH cable 1100 Volts grade, ISI-694 marked with valid CML No.in and including medium grade, PVC consealed conduit of 20mm bore with accessories in wall/roof/floor etc, and sunken galvanized pressed steel terminal boxes of thickness not less than 1.12 mm covered with 2.80 mm thick phenolic laminated white sheet cover for one 15 amp socket outlet controlled by one switch on independent board incl 1.5 Sq mm copper conductor earth wire and connected to common earth dolly on independent board. |
| 86 | S&F ceiling rose, PVC of size 65mmx50mm three terminals (ISI marked) all as specified and directed by Engineer-in-charge. |
| 87 | S & F modular switch 1 way 6A, 1 module. |
| 88 | S & F modular switch 1 way 16A, 1 module |
| 89 | S & F modular socket, 6A - 3 pin combined 2 module |
| 90 | S & F modular modular Socket 6A/16A - 3 pin combined 2 module. |
| 91 | S & F modular fan regulator step type, 120W - 2 module |
| 92 | M&L modular white cover plate with frame ( both inner plate & outer plate cover ), 2 module. |
| 93 | M&L modular white cover plate with frame ( both inner plate & outer plate cover ), 3 module. |
| 94 | M&L modular white cover plate with frame ( both inner plate & outer plate cover ), 6 module. |
| 95 | M&L modular white cover plate with frame ( both inner plate & outer plate cover ), 8 module. |
| 96 | M&L modular Modular metal flush box 1 & 2 module |
| 97 | M&L modular metal flush box 3 module |
| 98 | M&L modular metal flush box 6 module |
| 99 | M&L modular metal flush box 8 module |
| 100 | S&F in repair MCB single pole 6 to 32 Amps, 240 Volts, 10 KA rapturing capacity, 'C' Curve complete all as directed by Engineer-in-charge. |
| 101 | S&F in repair MCB single pole & neutral 40 Amps, 240 Volts, 10 KA rapturing capacity, 'C' Curve complete all as directed by Engineer-in-charge. |
| 102 | S&F in repair sheet metal enclosure DB's 240 Volts, IP-43, suitable for mounting MCB's, SPN, 8 way with 200 Amps rated copper bus bar double door type complete all as directed by Engineer-in-charge. |
| 103 | S&F in repair sheet metal enclosure DB's 240 Volts, IP-43, suitable for mounting MCB's, SPN, 4 way with 200 Amps rated copper bus bar double door type complete all as directed by Engineer-in-charge. |
| 104 | S&F lamp holder, PVC/ polycarbonate type with back plate suitable for batten fittings and including LED lamp 12 watt complete all as specified and directed by Engineer-in-charge.Make : Crompton Greaves/Havells/Philips/Bajaj |
| 105 | S & F in repair LED building Security light fitting 1x20watt with polycarbonate housing, Aluminum gear tray duly prewired inbuilt LED module IP 65 Protection complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of size 1.5 sq mm including GI tubing 40mm dia light grade 1.5m long band to shape for mounting of security light with 2 nos MS,FI clamp including plinth with nut bolts etc complete all as specified and directed Make: Crompton Greaves/Havells/Philips/ Bajaj. |
| 106 | Taking down existing earthing and M&L for new Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 5 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron 15 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of strata, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as directed.(i) The concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 5 of MES SSR Part-I. ii) Item includes the cost of 7.5M GI pipe for protection of earth wire. Any variation in length shall be adjusted through deviation order. (iii) Item includes cost of 7.5 M earth lead wire. Any variation in length shall be adjusted through deviation order. (iv) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate. |
| 107 | S&F service connection of 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathed of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core multistandard cable flat or circular of 4 Sqmm 2 core including taking down old service cable complete all as specified & directed by Engineer-in-charge.(NOTE: Two runs of 4.0 sqmm cable & One run of 4.0 sqmm cable and One run of PVC casing & capping/ conduit shall be paid as one unit length.) |
| 108 | M & L for submain wiring with approved colour code/as per IS (Red, black & green for single phase) circuit with two single core PVC insulated cable with multistranded copper coductor of nominal cross sectional area of 6.0 Sq mm (FRLS) in PVC casing & capping non metallic including one run of PVC insulated multistranded copper conductor nominal cross section area of 4 Sq mm (FRLS) of continuous earth wire green in colour complete all as specified and directed by Engineer-in-charge. Note: Two runs of 6.0 sqmm cable & One run of 6.00 sqmm cable and One run of PVC casing & capping/ conduit shall be paid as one unit length.) |
| 109 | Taking down old unserviceable LT cable and supply, Laying and testing of XLPE insulated, armoured heavy duty electric cables with aluminum conductor, 1100 volt grade, of cross sectional area of 10 Sqmm 2 core all as specified directed by Engineer In charge |
| 110 | Excavation in trenches not exceeding 1.5mtr wide & not exceeding 1.5 mtr in depth for laying LT cable, any type of soil complete all as directed. |
| 111 | Returning, filling in trenches with soil, including spreding, leveling, watering & well ramming, in layers not exceeding 25 cm each complete |
| 112 | Removing surplus excavated material (soil) to distance not exceeding 50 Mtr & depositing where directed at level not exceeding 1.5 mtr above the starting point. |
| 113 | Sand filling in cable trenches for cable protection with clean dry sand unwashed including gently put in trench |
| 114 | S&F for old size brick well burnt, laid flat, for cable protection complete all as specified and directed. |
| 115 | S & F in repair box type fitting 1x 16w, blue coloured end caps, prewired for LED tube including LED tube 16 watts, including connecting up with twin core twisted flexible copper conductor cable with suitable size complete and all as specified and directed by Engineer- in Charge.”. Make: Cromton Greaves Cat part no for Fitting DMLN1LT8-16 and for LED tube LTT8-16 or Equivalent make of Havells/Philips. |
| 116 | Supply and fixing in repair ceiling fans complete with blades down rods ,electronic regulator and accessories, 230V, 1200MM sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five ster rated with brushess direct current motor (BLDC).Note : Old unserviceable fan shall be deposited in store yard by contractor. Engr-in-Charge shall mention ledger No and page No in demolition statement with final bill. Please Enable Macros to View BoQ information |