| 1 | Taking down of cement plaster from surfaces of wall of any description including raking out joints, hacking out for key, scrubbing down with water etc including complete treatment if any all as specified. |
| 2 | M&L for rendering 15mm thick cement plaster in two layers with 10mm thick in cement mortar (1:6) as 1st coat and 5mm thick in cement mortar (1:4) mixed with water proofing compound @ 3% by weight of cement as 2nd coat on brick or concrete wall surfaces, finished even and smooth without extra cement complete all as specified and directed. Note:- (i) WPC shall be measured and paid for separately.(ii) Liquid water proofing compound of approved make shall be used as per manufacures |
| 3 | M&L for preparation and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required hade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over existing surfaces of wall (in approved camouflaged pattern as directed) incl removal of existing treatment with brooming down or steel wire brushing etc complete specified and directed by Engr-in-charge. |
| 4 | Demolition of brick/block work or stone/boulder masonary built in cement mortar complete all as specified and as directed. |
| 5 | M&L for pre cast cement concrete block masonary with solid block of cement concrete 1:5:8 exc 10 cm in width and setting in CM 1:4 complete all as specified and as directed. |
| 6 | Taking down existing bitumen felt including cement mortar bedding including padding cleaning the surface and removal outside the MOD land complete all as specified and directed. |
| 7 | M&L for providing cement concrete (1:2:4) type B-0 (using 12.50mm graded stone aggregate) laid on roof in adequate slope complete all as specified and directed. |
| 8 | M&L for rendering 10mm thick cement plaster in cement mortar 1:3 on roof slab/canopies/chajjas with water proofing compound @3% by weight of cement or as per manufacture's instruction and make surface to receive water proofing treatment, finished even and smooth without using extra cement complete all as specified and directed. (Note:- water proofing compound will be measured and paid for separetaly as under relevant item) |
| 9 | Supply only Liquid water proofing compound |
| 10 | M&L for preparing, clean and dried plastered roof surfaces and applying APP modified water proofing membrane with non woven polyster reinforcement/mat not less than 3mm thick having weight not less than 3.5 kg/sqm over a coat of bituminous filler/primer @ 250gm/sqm conforming to IS 3384-1986 through approved applicator all as per manufacture's instructions complete all as specified and directed. |
| 11 | S&F for Unplasticised PVC pipes with all fittings and fixed to walls and ceilings or laid in floors for 15 mm bore of pipe including taking up or down steel tubing and connections for 15mm bore of pipe complete all as specified and directed. |
| 12 | S&F for Unplasticised PVC pipes with all fittings and fixed to walls and ceilings or laid in floors for 25 mm bore of pipe including taking up or down steel tubing and connections for 25mm bore of pipe complete all as specified and directed. |
| 13 | S&F for Unplasticised PVC pipes with all fittings and fixed to walls and ceilings or laid in floors for 20 mm bore of pipe including taking up or down steel tubing and connections for 20mm bore of pipe complete all as specified and directed. |
| 14 | S&F for Unplasticised PVC pipes with all fittings and fixed to walls and ceilings or laid in floors for 40 mm bore of pipe including taking up or down steel tubing and connections for 40mm bore of pipe complete all as specified and directed. |
| 15 | Refixing old steel tubing with all fittings and fixed to wall and connections in new or old size 15mm bore position (Walls, ceiling,floors, etc.) including taking up or down steel tubing and all new fitting and fixtures etc |
| 16 | Refixing old steel tubing with all fittings and fixed to wall and connections in new or old size 20 mm bore position (Walls, ceiling,floors, etc.) including taking up or down steel tubing and all new fitting and fixtures etc |
| 17 | Refixing old steel tubing with all fittings and fixed to wall and connections in new or old size 25 mm bore position (Walls, ceiling,floors, etc.) including taking up or down steel tubing and all new fitting and fixtures etc |
| 18 | Refixing old steel tubing with all fittings and fixed to wall and connections in new or old size 40mm bore position (Walls, ceiling,floors, etc.) including taking up or down steel tubing and all new fitting and fixtures etc |
| 19 | M&L for cutting out cracks to 'V' section in existing roof or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified and directed |
| 20 | S&F for 20mm bore, Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule complete all as specified and as directed. |
| 21 | S&F 20 mm bore, gun metal or globe or gate valves, with iron wheel head, screwed both ends for iron pipe compledte all as specified and as directed |
| 22 | Disconnecting existing tanks, Exc 250 & n.exc 500 ltr setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position including Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc. |
| 23 | Ditto all as per item No 22 above but for capacity exc 500 liters & n exc 1000 liters all as specified and directed |
| 24 | Dismantling water tanks and removing to store exc 250 & not Exc 500 ltr Capacity |
| 25 | S&F for 500 litrs Rotational moulded polythylene white color tripple layer water storage tanks (cylindrical vertical with closed top ) hoisted and fixed in position all as specified in SSR part I |
| 26 | Dismantling water tanks and removing to store exc 500 & not Exc 1000 ltr Capacity |
| 27 | Ditto as per item No 25 above but for capacity exc 500 liters & n exc 1000 liters all as specified and directed |
| 28 | Taking down existing split type AC of 1.5/ 2.0 Ton capacity, from one location and re- fixing the AC at Same location/other location as directed, including replacement of 3 core copper cable require for connecting IDU & ODU, additional copper tube if required, cleaning the IDU and ODU for smooth functioning etc. complete all as specified and as directed. |
| 29 | Taking down existing solar panel including cutting connections any capacity, from one location or re- fixing the same without damage and fix to working for smooth functioning etc. complete all as specified and as directed. Please Enable Macros to View BoQ information |